• Title/Summary/Keyword: Steel supports

Search Result 197, Processing Time 0.022 seconds

Investigation on the flexural behavior of an innovative U-shaped steel-concrete composite beam

  • Turetta, Maxime;Odenbreit, Christoph;Khelil, Abdelouahab;Martin, Pierre-Olivier
    • Steel and Composite Structures
    • /
    • v.34 no.3
    • /
    • pp.441-452
    • /
    • 2020
  • Within the French CIFRE research project COMINO, an innovative type of composite beam was developed for buildings that need fire resistance with no additional supports in construction stage. The developed solution is composed of a steel U-shaped beam acting as a formwork in construction stage for a reinforced concrete part that provides the fire resistance. In the exploitation stage, the steel and the reinforced concrete are acting together as a composite beam. This paper presents the investigation made on the load bearing capacity of this new developed steel-concrete composite section. A full-scale test has been carried out at the Laboratory of Structural Engineering of the University of Luxembourg. The paper presents the configuration of the specimen, the fabrication process and the obtained test results. The beam behaved compositely and exhibited high ductility and bending resistance. The shear connection in the tension zone was effective. The beam failed by a separation between the slab and the beam at high deformations, excessive shear forces conducted to a failure of the stirrups in this zone. The test results are then compared with good agreement to analytical methods of design based on EN 1994 and design guidelines are given.

Vortex-Induced Vibration Analysis of Deep-Sea Riser (심해 라이저의 와류유기 진동해석)

  • Park, Seongjong;Kim, Bongjae
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.364-370
    • /
    • 2017
  • A numerical model based on the mode superposition method is used to study the vortex-induced vibration response characteristics of a deep-sea riser such as steel catenary riser (SCR). A steel catenary riser can be modeled using a flexible cable with simple supports at both ends. The natural frequency, mode shape and mode curvature of the riser are calculated and the vortex-induced vibration response of the riser is obtained using the equilibrium of the input and output power. The mode superposition method is applied to the vibrational stresses for each mode to calculate the overall riser fatigue life.

Long-term deflection of high-strength fiber reinforced concrete beams

  • Ashour, Samir A.;Mahmood, Khalid;Wafa, Faisal F.
    • Structural Engineering and Mechanics
    • /
    • v.8 no.6
    • /
    • pp.531-546
    • /
    • 1999
  • The paper presents an experimental and theoretical study on the influence of steel fibers and longitudinal tension and compression reinforcements on immediate and long-term deflections of high-strength concrete beams of 85 MPa (12,300 psi) compressive, strength. Test results of eighteen beams subjected to sustained load for 180 days show that the deflection behavior depends on the longitudinal tension and compression reinforcement ratios and fiber content; excessive amount of compression reinforcement and fibers may have an unfavorable effect on the long-term deflections. The beams having the ACI Code's minimum longitudinal tension reinforcement showed much higher time-dependent deflection to immediate deflection ratio, when compared with that of the beams having about 50 percent of the balanced tension reinforcement. The results of theoretical analysis of tested beams and those of a parametric study show that the influence of steel fibers in increasing the moment of inertia of cracked transformed sections is most pronounced in beams having small amount of longitudinal tension reinforcement.

Frictional characteristics of stainless steel lubricated with pressurized high temperature water (고온/고압 하에서 물로 윤활되는 스테인레스 강의 마찰 특성)

  • 이재선;김은현;김지호;김종인
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.96-99
    • /
    • 2001
  • The fatigue life of support bearings is one of the most critical factors for the performance of a control rod driving mechanism. They are operated at high temperature and high pressure and especially lubricated with dramatically low viscosity water. The support bearing is made of standardized 440C stainless steel, and it supports thrust load including the weight of the driving system and external force. Friction and wear characteristics of this material operating under severe lubrication condition is not well known yet, although it is expected to be changed with respect to temperature and boundary pressure. So the friction characteristics are investigated in sliding conditions using the reciprocating tribometer which can simulate the operating conditions. Highly purified water is used as lubricant, and the water is heated up and pressurized. Friction farce on the reciprocating specimens is monitored by the load cells. The results of the experiments are presented in this paper.

  • PDF

Elastoplastic nonlinear behavior of planar steel gabled frame

  • Moghaddam, Sina Heyrani;Masoodi, Amir R.
    • Advances in Computational Design
    • /
    • v.4 no.4
    • /
    • pp.397-413
    • /
    • 2019
  • In this paper, static nonlinear analysis of gable frame is performed using OpenSees software. Both geometric and material nonlinearities are considered in analyses. To consider large displacements, co-rotational coordinate transformation is used in software. The effects of symmetric and asymmetric support conditions including clamped and simple supports are studied. On the other hand, the material nonlinearity is reflected on analyses using Giuffre-Menegotto-Pinto steel material. Note that strain hardening characteristics are also considered in this model. Moreover, I-shaped cross-section is assumed for all members. The results are provided for different geometry properties of gable frame including shallow and deep inclined roof. It should be added that buckling and post-buckling behaviors of gable frame are investigated using related equilibrium paths. A comparison study is also implemented on the responses of buckling loads obtained for different support and geometry conditions. To trace snap-through paths completely, a displacement control method entitled arc-length is utilized. Findings show the capability of proposed model in nonlinear analysis of gable frames.

A Level 2 Middleware for Steel Plant Control (철강플랜트 제어를 위한 레벨 2 미들웨어)

  • Kim, DoHun;Hwang, Hwa-Won;Choi, Ja Young;Ko, JaeHoon;Kim, Chee-Ha
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.2
    • /
    • pp.86-92
    • /
    • 2011
  • In this paper, we proposed a level 2 middleware with common services for controlling steel plants, which is named POSMOS. POSMOS supports eight middleware services currently, but, this paper described in detail two representative services of the common services: file service and external communication service and their respective measured performance. In the experiment section, we described the performance of the two representative services and a case using our middleware which shows better response time than the existing commercial middleware by about 32%.

Performance evaluation of lattice girder depending on the quality of steel (강재 품질에 따른 격자지보재의 성능평가)

  • Jung, Hyuk-Sang;Shin, Young-Wan;Song, Ki-Il;Shin, Jong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.2
    • /
    • pp.165-173
    • /
    • 2016
  • This paper dealt with contents on the performance evaluation of standardized steel and non-standardized steel of lattice girder. Lattice girder is arch type tunnel supports made of structural steel bar and it is girder used to ensure the stability of tunnel by suppressing any transformation of ground as much as possible during tunnel excavation. The performance evaluation of lattice girder can be conducted through bending strength test, tensile strength test and tunnel standard specification specifies that welding structural steel with over 500MPa yield strength shall be used. However, it is difficult to distinguish visually between standardized steel and non-standardized steel onsite if low-quality structural steel is used. Accordingly, this paper conducted performance evaluation of standardized steel and non-standardized steel of lattice girder to point out the issue of deteriorated yield strength of non-standardized steel, while proposed a method of verifying yield strength onsite.

Plastic load bearing capacity of multispan composite highway bridges with longitudinally stiffened webs

  • Unterweger, Harald;Lechner, Andreas;Greiner, Richard
    • Steel and Composite Structures
    • /
    • v.11 no.1
    • /
    • pp.1-19
    • /
    • 2011
  • The introduction of the Eurocodes makes plastic design criteria available also for composite bridges, leading to more economical solutions compared with previous elastic design rules. Particularly for refurbishment old bridges with higher actual traffic loads, up to date outside the scope of the Eurocodes, strengthening should therefore be avoidable or at least be necessary only to a minor extent. For bridges with smaller spans and compact cross sections, the plastic load bearing capacity is clearly justified. In this work, however, the focus is placed on long span continuous composite bridges with deep, longitudinally stiffened girders, susceptible to local buckling. In a first step, the elastic - plastic cross section capacity of the main girder in bending is studied as an isolated case, based on high preloads acting on the steel girder only, due to the common assembling procedure without scaffolding. In a second step, the effects on the whole structure are studied, because utilising the plastic section capacity at midspan leads to a redistribution of internal forces to the supports. Based on the comprehensive study of an old, actual strengthened composite bridge, some limitations for plastic design are identified. Moreover, fully plastic design will sometimes need additional global analysis. Practical recommendations are given for design purposes.

Shear strength analysis and prediction of reinforced concrete transfer beams in high-rise buildings

  • Londhe, R.S.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.1
    • /
    • pp.39-59
    • /
    • 2011
  • Results of an experimental investigation on the behavior and ultimate shear capacity of 27 reinforced concrete Transfer (deep) beams are summarized. The main variables were percent longitudinal(tension) steel (0.28 to 0.60%), percent horizontal web steel (0.60 to 2.40%), percent vertical steel (0.50to 2.25%), percent orthogonal web steel, shear span-to-depth ratio (1.10 to 3.20) and cube concrete compressive strength (32 MPa to 48 MPa).The span of the beam has been kept constant at 1000 mm with100 mm overhang on either side of the supports. The result of this study shows that the load transfer capacity of transfer (deep) beam with distributed longitudinal reinforcement is increased significantly. Also, the vertical shear reinforcement is more effective than the horizontal reinforcement in increasing the shear capacity as well as to transform the brittle mode of failure in to the ductile mode of failure. It has been observed that the orthogonal web reinforcement is highly influencing parameter to generate the shear capacity of transfer beams as well as its failure modes. Moreover, the results from the experiments have been processed suitably and presented an analytical model for design of transfer beams in high-rise buildings for estimating the shear capacity of beams.

Optimum design of steel frames against progressive collapse by guided simulated annealing algorithm

  • Bilal Tayfur;Ayse T. Daloglu
    • Steel and Composite Structures
    • /
    • v.50 no.5
    • /
    • pp.583-594
    • /
    • 2024
  • In this paper, a Guided Simulated Annealing (GSA) algorithm is presented to optimize 2D and 3D steel frames against Progressive Collapse. Considering the nature of structural optimization problems, a number of restrictions and improvements have been applied to the decision mechanisms of the algorithm without harming the randomness. With these improvements, the algorithm aims to focus relatively on the flawed variables of the analyzed frame. Besides that, it is intended to be more rational by instituting structural constraints on the sections to be selected as variables. In addition to the LRFD restrictions, the alternate path method with nonlinear dynamic procedure is used to assess the risk of progressive collapse, as specified in the US Department of Defense United Facilities Criteria (UFC) Design of Buildings to Resist Progressive Collapse. The entire optimization procedure was carried out on a C# software that supports parallel processing developed by the authors, and the frames were analyzed in SAP2000 using OAPI. Time history analyses of the removal scenarios are distributed to the processor cores in order to reduce computational time. The GSA produced 3% lighter structure weights than the SA (Simulated Annealing) and 4% lighter structure weights than the GA (Genetic Algorithm) for the 2D steel frame. For the 3D model, the GSA obtained 3% lighter results than the SA. Furthermore, it is clear that the UFC and LRFD requirements differ when the acceptance criteria are examined. It has been observed that the moment capacity of the entire frame is critical when designing according to UFC.