• Title/Summary/Keyword: Steel frame structure

Search Result 566, Processing Time 0.026 seconds

Buckling analysis of complex structures with refined model built of frame and shell finite elements

  • Hajdo, Emina;Ibrahimbegovic, Adnan;Dolarevic, Samir
    • Coupled systems mechanics
    • /
    • v.9 no.1
    • /
    • pp.29-46
    • /
    • 2020
  • In this paper we deal with stability problems of any complex structure that can be modeled by beam and shell finite elements. We use for illustration the steel plate girders, which are used in bridge construction, and in industrial halls or building construction. Long spans, slender cross sections exposed to heavy loads, are all critical design points engineers must take into account. Knowing the critical load that will cause lateral torsional buckling of the girder, or load that can lead to web buckling, as an important scenario to consider in a design process.Many of such problem, including lateral torsional buckling with influence of lateral supports and their spacing on critical load can be solved by the proposed method. An illustrative study of web buckling also includes effects of position and spacing of transverse and longitudinal web stiffeners, where stiffeners can be modelled optionally using shell or frame elements.

Seismic response of dual structures comprised by Buckling-Restrained Braces (BRB) and RC walls

  • Beiraghi, Hamid
    • Structural Engineering and Mechanics
    • /
    • v.72 no.4
    • /
    • pp.443-454
    • /
    • 2019
  • In order to reduce the residual drift of a structure in structural engineering field, a combined structural system (dual) consisting of steel buckling-restrained braced frame (BRBF) along with shear wall is proposed. In this paper, BRBFs are used with special reinforced concrete shear walls as combined systems. Some prototype models of the proposed combined systems as well as steel BRBF-only systems (without walls) are designed according to the code recommendations. Then, the nonlinear model of the systems is prepared using fiber elements for the reinforced concrete wall and appropriate elements for the BRBs. Seismic responses of the combined systems subjected to ground motions at maximum considered earthquake level are investigated and compared to those obtained from BRBFs. Results showed that the maximum residual inter-story drift from the combined systems is, on average, less than half of the corresponding value of the BRBFs. In this research, mean of absolute values of the maximum inter-story drift ratio demand obtained from combined systems is less than the 3% limitation, while this criterion has not been fulfilled by BRBF systems.

Study on Elasto-Plastic Behavior of Column to Beam Connection with 600MPa High Performance Steel(SM 570 TMC) (기둥-보 용접접합부의 보단부 스캘럽형상과 탄소성 거동에 관한 실험적 연구 - 600MPa(SM570TMC)의 경우 -)

  • Kim, Jong Rak;Kim, Seung Bae;Kwon, June Yeop
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.6
    • /
    • pp.691-700
    • /
    • 2008
  • Contemporary architectural structures have diverse and complex forms. Such structural variety demands requisite performance from the connections in the steel structure so that the latter could resist a horizontal force, such as an earthquake. The connections are the all-important components that create the discontinuous form and that support stress concentration, determining the stiffness and toughness of the entire steel frame. In this study, a real-scale column-to-beam connection was constructed in the 600MPa-grade high-strength and high-performance steel, to test its behavior. Its material and welding characteristics were examined in this study, and its structural performance was analyzed by conducting seismic-resistance tests on the full-scale, cross-shaped column-to-beam welded connections with non-scallop, ordinary-scallop, and reinforced-scallop details. The weld ability of the high-strength, high-performance steel was also evaluated, and data regarding the seismic design for practical application were provided.

A Vibration Response Analysis of Steel Building Frame with V Shape Brace Vibrationally Controlled by Turbulent Flow Dampers Sealed by Visco-Elastic Material (점탄성물질 난류댐퍼를 이용한 V형 철골 브레이스 골조의 진동응답해석)

  • Lee, Ho;Lee, Sang-Yeob
    • Journal of Korean Association for Spatial Structures
    • /
    • v.2 no.3 s.5
    • /
    • pp.103-113
    • /
    • 2002
  • This thesis investigates vibration response characteristics of building frames in which dampers are installed. The frames belong to passively vibration-controlled. Structures which utilizes energy dissipation of mechanical dampers provided in the structure. In this thesis, a turbulent flow damper sealed by visco-elastic material was dealt with as the device of passive vibration control. To investigate the resisting force characteristics of the damper, harmonic vibratration tests were carried out. Based on the test results, a theoretical model of the damper resistance was presented and a method of identifying the model parameters was proposed. Shaking table tests of the frame with and without the dampers were carried out and the effectiveness of the damper was examined. The response of the frame with the dampers was reduced to 1/2 or 1/3 of the cases without the damper.

  • PDF

A Study on the Simple Design Method of Semi-Rigid Connection with Angle in Steel Structure (강구조에서 ㄱ형강을 이용한 반강접 접합의 간편 설계)

  • Heo, Myong-Jae;Kim, Hong-Geun;Choi, Won-Gu
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.261-273
    • /
    • 2011
  • Recently, the demands for steel frame are increasing because of the trend and due to the demand for bigger and higher buildings. In the analysis of typical steel frame, connections are based on the idealized fixed or pinned connection. A fixed connection assumes that the relative angle of each member before deformation is the same after the transformation. Therefore, the stiffener reinforces the connection to sufficient rigidity and stability of the panel zone. In the economical aspect, however, the necessity of connection that the stiffener reinforcement has omitted is increasing due to the excessive production as well as labor costs of connection. In contrast, pinned connection is assumed that bending moments between the beams and columns do not transfer to each member. This is easy to make in the plant and the construction is simple. However, the structural efficiency is reduced in pinned connection because connection cannot transfer moments. The introduction of this semirigid process can decide efficient cross-sectional dimensions that promote ease in the course of structural erection, as performed by members in the field-a call for safety in the entire frame. Therefore, foreign countries exert efforts to study the practical behavior and the results are applied to criterion. This paper analyzes the semirigid connection of domestic steel by design specifications of AISC/LRFD and make data bank that pertain to each steel. After wards, the results are compared to those of idealized connection; at the same time, this paper presents a design method that matches economic efficiency, end-fixity, and rotational stiffness.

A Study on the Design and Structural Analysis of the Unmanned Underwater Vehicle (심해 무인 잠수정 프레임의 설계 및 구조해석에 관한 연구)

  • JOUNG TAE-HWAN;NHO IN-SIK;CHUN IL-YONG;LEE JONG-Moo
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.172-177
    • /
    • 2004
  • This paper presents the results of the structural analysis and optimal design of frames of the UUV(Unmanned Underwater vehicle) to be operated at 6000m depth in the ocean. The structure of the UUV system can be classified into two structure, Launcher ana ROV. Frame of the launcher will be made by Galvanized Steel which has high strength and corrosion-resistant but this material has high specific gravity for tile object to be weight in the water Similarly, ROV will be made by AI6061-T6, and frame of the ROV will be fix many instruments and syntactic buoyancy materials. Before fabrication of tile frame, we performed sensitivity analysis - change in weight due to $\pm1\%$ change in design variables, for easy choice by change of dimension of the frame.

  • PDF

A shake table investigation on interaction between buildings in a row

  • Khatiwada, Sushil;Chouw, Nawawi
    • Coupled systems mechanics
    • /
    • v.2 no.2
    • /
    • pp.175-190
    • /
    • 2013
  • Pounding damage has been observed frequently in major earthquakes in the form of aesthetic, minor or major structural cracks and collapse of buildings. Studies have identified a building located at one end of a row of buildings as very vulnerable to pounding damage, while buildings in the interior of the same row are assumed to be safer. This study presents the results of a shake table investigation of pounding between two and three buildings in a row. Two steel portal frames, one stiffer and another more flexible, were subjected to pounding against a frame with eight other configurations. Three pounding arrangements were considered, i.e., the reference frame (1) on the right of the second frame, (2) in the middle of two identical frames, and (3) on the right of two identical frames. Zero seismic gap was adopted for all tests. Five different ground motions are applied from both directions (right to left and left to right). The amplification of the maximum deflection due to pounding was calculated for each configuration. The results showed that, for the stiffer building in a row, row building pounding is more hazardous than pounding between only two buildings. The location of the stiffer frame, whether at the end or the middle of the row, did not have much effect on the degree of amplification observed. Additionally, for all cases considered, pounding caused less amplification for stronger ground motions, i.e., the ground motions that produced higher maximum deflection without pounding than other ground motions.

Pseudo-dynamic test of the steel frame - Shear wall with prefabricated floor structure

  • Han, Chun;Li, Qingning;Jiang, Weishan;Yin, Junhong;Yan, Lei
    • Steel and Composite Structures
    • /
    • v.20 no.2
    • /
    • pp.431-445
    • /
    • 2016
  • Seismic behavior of new composite structural system with a fabricated floor was studied. A two-bay and three-story structural model with the scale ratio of 1/4 was consequently designed. Based on the proposed model, multiple factors including energy dissipation capacity, stiffness degradation and deformation performance were analyzed through equivalent single degree of freedom pseudo-dynamic test with different earthquake levels. The results show that, structural integrity as well as the effective transmission of the horizontal force can be ensured by additional X bracing at the bottom of the rigidity of the floor without concrete topping. It is proved that the cast-in-place floor in areas with high seismic intensity can be replaced by the prefabricated floor without pouring surface layer. The results provide a reliable theoretical basis for the seismic design of the similar structural systems in engineering application.

The Structural Design of "China Zun" Tower, Beijing

  • Liu, Peng;Cheng, Yu;Zhu, Yan-Song
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.3
    • /
    • pp.213-220
    • /
    • 2016
  • The "China Zun" tower in Beijing will rise to 528 meters in height and will be the tallest building in Beijing once built. Inspired by an ancient Chinese vessel, the "Zun", the plan dimensions reduce gradually from the bottom of the tower to the waist and then expand again as it rises to form an aesthetically beautiful and unique geometry. To satisfy the structural requirement for seismic and wind resistance, the structure is a dual system composed of a perimeter mega structure made of composite mega columns, mega braces, and belt trusses, and a reinforced-concrete core with steel plate-embedded walls. Advanced parametric design technology is applied to find the most efficient outer-perimeter structure system. The seismic design basically follows a mixed empirical and performance-based methodology that was verified by a shaking table test and other specimen lab tests. The tower is now half-way through its construction.

Structural Joint Damage Assessment using Neural Networks (신경망을 이용한 구조물 접합부의 손상도 추정)

  • 방은영
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.131-138
    • /
    • 1998
  • Structural damage is used to be modeled through reductions in the stiffness of structural elements for the purpose of damage estimation of structural system. In this study, the concept of joint damage is employed for more realistic damage assessment of a steel structure. The joint damage is estimated damage based on the mode shape informations using neural networks. The beam-to-column connection in a steel frame structure is represented by a rotational spring at the fixed end of a beam element. The severity of joint damage is defined as the reduction ratio of the connection stiffness with respect to the value of the intact joint. The concept of the substructural identification is used for the localized damage assessment in a large structure. The feasibility of the proposed method is examined using an example with simulated data. It has been found that the joint damages can be reasonably estimated for the case with the measurements of the mode vectors subjected to noise.

  • PDF