• 제목/요약/키워드: Steel for Construction

검색결과 3,425건 처리시간 0.029초

건축물의 등전위 본딩 및 전기적 연속성 평가 (Assessment of Equipotential Bonding and Electrical Continuity in Buildings)

  • 길형준;김동우;김동욱;이기연;문현욱;김향곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.385-386
    • /
    • 2009
  • This paper deals with assessment of equipotential bonding and electrical continuity in Buinding by investigation on the spot at construction site. The assessment was carried out for continuity of steelwork in reinforced concrete structure, bonding conductor, protective conductor. A new grounding system based on international standards includes unity grounding system, structure grounding utilizing steel reinforced concrete, equipotential bonding, use of surge protective device.

  • PDF

9%Ni 강의 전자빔 용접성에 관한 연구 (III) - 전자빔 용접부 기계적 특성과 조직 - (A Study on electron beam veldability of 9%Ni steels (III) - Microstructures and mechanical properties of welded joints -)

  • 김숙환;강정윤
    • Journal of Welding and Joining
    • /
    • 제15권4호
    • /
    • pp.116-125
    • /
    • 1997
  • Electron beam weldability of 9%Ni steels has been investigated to apply EBW to the construction of LNG storage tank. While mechanical properties of welded joints were satisfied by ASTM specification, impact energy of weld metal was as low as 27 - 55J at $-196^{\circ}C$. As the result of Ni wires inserted at the joint to be welded, Ni content of weld metal was increased to about 10%, resulting on the improvement of impact toughness to 110 ~ 120J at $-196^{\circ}C$. This improvement of impact toughness in weld metal was due to the formation of tempered martensite and retained austenite. Above results indicate that, if Ni content of weld metal was increased about 10% by Ni wires addition, electron beam welded 9%Ni steels weld metal had sufficient impact energy necessary for a LNG storage tank.

  • PDF

지하구조물을 위한 수밀콘크리트의 개발 및 실용화 (Development and Application of Low Permeable Concrete for Underground Structures)

  • 백상현;박성수;박종유;백원준;엄태선;최롱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.259-262
    • /
    • 1999
  • In underground reinforced concrete structures, such as drainage structure, water and chloride ion penetrated into concrete through the cracks of concrete and its permeable property, cause the corrosion of reinforcing steel bar, which accelerates the expansive cracks and deterioration of concrete. It is necessary to control those deterioration of underground structure by improving its permeability and durability through the reasonable solutions in design, construction and materials. In the present study, fly ash concrete, which has good material properties in long-term period, was compared and studied with plain concrete using ordinary portland cement in terms of fundamental mechanical properties, permeability, drying shrinkage and durability. Also, the mix design and field test of low permeable concrete using fly ash were performed. From this study, fly ash concrete can control the penetration of water and chloride ion effectively by forming dense micro-structure of concrete. Therefore, fly ash concrete may increase the long-term function, performance and serviceability of underground structures.

  • PDF

철근이 부식된 철근콘크리트 슬래브의 구조성능 평가 (Evaluation of Structural Performance of Reinforced Concrete Slab due to Steel Corrosion)

  • 이창복;이경언;박현수;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.597-600
    • /
    • 1999
  • Recitly, the use of sea-sand is increasing in the construction due to the rapid reduction of river-sand. In that case, one of the major problem is that a sand salt in sea-sand induce the corrosion of embedded reinforcing bar in concrete. In addition, the deterioration of concrete quality arises a social problem in the durability of reinforced concrete. This research is aimed at providing the data for the control of design method of repair and rehabilitation in the reinforced concrete structure by means of the evaluation of structural performance due to corrosion.

  • PDF

탄소섬유쉬트로 보강된 RC보의 휨 부착성능에 관한 실험적 연구 (An Experimental Study on Flexural Adhesive Performance of RC Beams Strengthened by Carbon Fiber Sheets)

  • 최기선;류화성;최근도;이한승;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.997-1002
    • /
    • 2001
  • Tensile strength of CFRP (Carbon Fiber Reinforced Polymer) is approximately 10 times higher than that steel reinforcement, but the design strength of CFRP is normally reduced by the bond failure between RC and CFRP. Many researches have been carried out, concerned with bond behavior between RC and CFRP to prevent the unpredicted bond failure of RC beam strengthened by CFRP, but the national design code for design bond strength of CFRP hasn't been constructed. In this study, 3 beams specimen strengthened by CFRP under the variable of bonded length were tested to derive the design bond strength of CFRP to the RC flexural members. Also 2 beams specimen strengthened by CFRP were tested to inspect the construction environment effects such as mixing error of epoxy resin and the amount of primer epoxy resin. From the test results, It is concluded that the maximum design bond strength of CFRP to RC flexural member is considered to be $\tau_{a}$=8kgf/$cm^{2}$.

  • PDF

고강도 콘크리트를 이용한 CFT 기둥의 충전성 연구 (A study on the Packing ability of Concrete Filled in Steel Tube Column by High Strength Concrete)

  • 강용학;조상영;정근호;백민수;김진호;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.991-996
    • /
    • 2002
  • In this study, there are kind of property experiments like fluidity, compressive strength, bleeding measurement, concrete sink for CFT use high fluidity concrete. The property difference between before transmit and after transmit concrete in the mock up test with ready mixed concrete equipment is examined. The variable factors in mock up are diaphragm existence and nonexistence, diaphragm placing hole sizes. To investigate the concrete property under diaphragm, concrete packing ability tests is peformed. High fluidity and strength concrete which satisfied with mix criteria could apply to building construction field. It it is quality managed with use of packing ability analysis.

  • PDF

매입형 히트파이프의 재질 및 규격변화에 따른 수화열 분산 효과 (Dispertion Effect of Hydration Heat due to Materials and Standard Variation of Embedded Heat Pipe)

  • 김명식;염치선;백동일
    • 한국해양공학회지
    • /
    • 제23권6호
    • /
    • pp.111-116
    • /
    • 2009
  • The cracking due to hydration heat in mass concrete must be resolved to improve the stability and durability of concrete structures. In this study, the economic efficiency was improved by replacing a copper pipe with a steel one for the heat pipe, and the heat pipe was standardized to significantly improve the operation efficiency, such as the processing, transport, assembly, and construction time. As a result of the experiment, the peak temperature of the ICSHP, ISSHP, and ISUHP specimens decreased by about $7.2{\sim}10.9^{\circ}C$ compared to the OPC specimen and the probability of a thermal crack being generated in the ICSHP, ISSHP, and ISUHP specimens decreased by up to 84~88%.

Damage detection and localization on a benchmark cable-stayed bridge

  • Domaneschi, Marco;Limongelli, Maria Pina;Martinelli, Luca
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1113-1126
    • /
    • 2015
  • A damage localization algorithm based on Operational Deformed Shapes and known as Interpolation Damage Detection Method, is herein applied to the finite element model of a cable stayed bridge for detecting and localizing damages in the stays and the supporting steel beams under the bridge deck. Frequency Response Functions have been calculated basing on the responses of the bridge model to low intensity seismic excitations and used to recover the Operational Deformed Shapes both in the transversal and in the vertical direction. The analyses have been carried in the undamaged configuration and repeated in several different damaged configurations. Results show that the method is able to detect the damage and its correct location, provided an accurate estimation of the Operational Deformed Shapes is available. Furthermore, the damage detection algorithm results effective also when damages coexist at the same time at several location of the cable-stayed bridge members.

철근콘크리트조 교육시설물의 열화성상에 관한 조사 연구 - 서울지역 초.중등교를 중심으로 - (Structural Deterioration of Educational Buildings in Reinforced Concrete Structure : Area Seoul)

  • 권기혁
    • 교육시설
    • /
    • 제4권3호
    • /
    • pp.5-14
    • /
    • 1997
  • The purpose of this study is to present basic data in order to improve the efficiency and the objectivity of diagnosing educational structures built with the reinforced concrete. For achieving the purpose, this paper, firstly, researches damage aspects of 22 public educational of facilities in Seoul, and summarizes the results of that research. Through the analysis and the evaluation of damage aspects, this paper shows the conclusions as follows; (1) Main damage to reduce structural capacities of building is the differential settlement. (2) Though the steel corrosion is occurred by several factors, the main cause is the faulty construction. (3) To prevent the damage development, a proper repair strategy is very important.

  • PDF

FBG 센서를 내장한 스마트 앵커의 개발과 적용 (Development and Application of A Smart Anchor with Optical FBG Sensors)

  • 김영상;서동남;김재민;이승래
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.393-398
    • /
    • 2008
  • With the substantial increase of the size of structure, management and monitoring of excavation for the foundation construction becomes more difficult. Therefore, massive collapses which are related to retaining wall recently increase. However, since the study on measuring and monitoring the pre-stressing force of anchor is insufficient, behavior of anchor may not be predicted and monitored appropriately by the existing strain gauge type monitoring system. FBG Sensor, which is smaller than strain gauge and has better durability and does not have a noise from electromagnetic waves, was adapted to develope a smart anchor. A series of pullout tests were performed to verify the feasibility of smart anchor and find out the load transfer mechanism around the steel wire fixed to rock with grout.

  • PDF