• 제목/요약/키워드: Steel anchor

검색결과 193건 처리시간 0.028초

그라운드 앵커의 하중전이 현상에 대한 연구 (A Study on Load Transfer of Ground Anchors)

  • 김낙경;박완서
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.441-448
    • /
    • 1999
  • The load distribution in a ground anchor is very complex because it involves three different materials(soil, grout, and steel), which sometimes act as composite sections (bonded length) or separately (unbounded length). Therefore it is very hard to understand load transfer mechanism on the anchor. In order to understand the load transfer, it is essential to consider the load distribution In the three different materials. On these purposes, full scale anchor test is planned on the geotechnical site at Sunkyunkwan University Prior to the test, modeling and analyses of the load transfer mechanism were performed on the data from the case histories.

  • PDF

후설치 콘크리트 세트앵커의 인발파괴거동에 관한 실험적 연구 (An Experimental Study on the Pullout Failure Behavior of Post-installed Concrete Set Anchor)

  • 숫러타;유승운
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.40-47
    • /
    • 2014
  • 최근 토목구조물의 보수 보강 및 리모델링시 구조부재를 부착시키거나 고정하는데 있어서 시공의 유연성 및 용이성으로 후설치 앵커의 사용량이 증가하고 있는 실정이지만 현재 우리나라에서는 설계자와 시공자가 신뢰할 수 있는 명확한 설계기준이 없는 상태로서 외국의 설계기준에 의존하고 있는 실정이다. 무근콘크리트에 매입된 앵커에 인발하중이 작용할 때 앵커의 다양한 파괴모드는 콘크리트 파괴, 쪼갬파괴, 강재파괴, 뽑힘파괴 및 측면파괴가 발생한다. 이것은 강재의 인장 강도, 콘크리트 강도, 매입 깊이, 앵커 간격, 연단거리와 인접 앵커의 존재에 따라 달라진다. 본 연구에서는 매입깊이, 앵커간격 및 연단거리를 변수로 한 후설치 콘크리트 세트앵커의 인발파괴실험을 통하여 무근콘크리트에 매입된 후설치 세트앵커의 인발거동에 미치는 영향을 규명하는 것을 그 목적으로 한다.

전단력을 받는 선설치 앵커볼트의 콘크리트 파열파괴강도 평가 연구 (A Study on the Concrete Breakout Capacity of CIP Anchor Bolts under Shear Loading)

  • 박용명;전명희;최명국;김철환;김인기
    • 한국강구조학회 논문집
    • /
    • 제24권2호
    • /
    • pp.207-215
    • /
    • 2012
  • 전단하중을 받는 앵커볼트의 설계에 $45^{\circ}$ 콘파괴 이론이 그동안 적용되어 왔으나, 2,000년 이후부터 CCD(Concrete Capacity Design) 방법이 새로운 설계법으로 도입되었다. 그러나, 본 방법은 주로 소형 앵커볼트에 대한 실험 결과에 근거한 관계로 앵커볼트의 직경이 50mm 이하인 경우에 한해 적용이 허용되고 있다. 따라서 큰 연단거리를 갖는 중대형 앵커볼트에 대한 합리적인 콘크리트 파열파괴강도식의 도출이 필요한 실정이다. 본 연구에서는 M56 선설치 단일 앵커볼트로 연단거리 350mm에 대해 콘크리트 파열파괴강도 평가를 위해 4개의 시험체에 대해 실험을 수행하였다. 그리고, 본 실험 결과와 타 연구의 실험 결과를 종합하여 연단거리 750mm까지의 큰 연단거리에 대해 새로운 전단파괴강도식을 제안하였다.

용접조립 각형 CFT 단주의 구조특성에 관한 실험적 연구 (An Experimental Study on Structural Performance of Welded Built-up Square CFT Stub Columns)

  • 이성희;최영환;염경수;김진호;최성모
    • 한국강구조학회 논문집
    • /
    • 제20권5호
    • /
    • pp.645-653
    • /
    • 2008
  • 용접조립 각형강관은 얇은 강판을 L형으로 절곡한 4개의 단위 부재를 플레어 용접으로 용접한 강관으로 용접조립 각형강관이 CFT 기둥으로 사용될 경우 콘크리트와 강관 폭의 중앙에 설치된 리브가 국부좌굴을 방지하는 역할을 하며 강관은 내부의 콘크리트의 구속하여 콘크리트의 구조내력을 향상시키는 역할을 한다. 본 연구에서는 용접조립 각형강관기둥의 제작방법을 소개하고 용접조립 각형강관과 용접조립 각형CFT 기둥 의 구조성능을 평가하기 위해 강관의 형상(용접조립 각형강관, 일반강관)과 폭두께비(B/t=50, 58, 67), 콘크리트의 강도(f'c=, 10MPa, 40MPa) 를 변수로 총 15개의 실대형 실험체를 제작하여 구조실험을 수행하였으며 용접조립 각형강관의 단면효율과 구조내력의 우수성을 확인하였다.

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms

  • Lee, Seong-Hui;Yang, Il-Seung;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제10권3호
    • /
    • pp.261-279
    • /
    • 2010
  • Generally, a box tube, which is used for an existing square CFT structure, is made by welding four plates. The manufacturing efficiency of this steel tube is poor, and it also needs special welding technology to weld its internal diaphragm and the through diaphragm. Therefore, an interior-anchor-type square steel tube was developed using the method of cold-forming thin plates to prevent welding of the stress concentration position, and to maximize the section efficiency. And, considering of the flow of beam flange load, the efficiency of erection and the weldability of the diaphragm to thin walled steel column, the external diaphragm connection was selected as the suitable type for the welded built-up square CFT column to beam connection. And, an analytical study and tests were conducted to evaluate the structural performance of the suggested connection details and to verify the suggested equations for the connection details. Through this study, the composite effect of the internal anchor to concrete, the resistance and stress distribution of the connections before and after the existing column is welded to the beam, the effective location of welding in connection were analyzed.

소규모 철골조건축물 강축방향 노출형 주각부의 내진성능 향상을 위한 실험 연구 (Experimental Study on Seismic Performance Enhancement of Exposed Column-base Plate Strong-axis Connections for Small-Sized Steel Buildings)

  • 유영찬
    • 대한건축학회논문집:구조계
    • /
    • 제34권12호
    • /
    • pp.11-20
    • /
    • 2018
  • The purpose of this study is to investigate the seismic performance of exposed column-base plate strong-axis connections for small-sized steel buildings. Even though the seismic design for small-sized buildings became mandatory since Dec.2017, the arbitrary connection details in steel structure have been applied at the construction site, which is considered to be very insufficient to secure structural safety and stability considering the increased seismic risk. Therefore, a series of experimental test programs had been carried out to develop enhanced connection details in order to ensue the adequate seismic safety of small buildings. The hysteretic behavior of the exposed column-base plate connections commonly used in Korea seem to be very pure poor due to the "Rocking" phenomena between anchor plate and concrete by the residual plastic deformation of anchor bolts. A series of hysteretic tests were conducted to find the solution to overcome the "Rocking" phenomena of the exposed column-base plate connections, finally the stable seismic behavior was obtained by uisng at least 8 anchor bolts with good bonding strength to the protptype specimen.

쐐기형 그라운드앵커의 인발 거동 특성 (Pullout Resistance Characteristics of the Wedge-shaped Ground Anchor)

  • 김정무;정원용;윤용수;정민규;장순호;이용준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1060-1064
    • /
    • 2010
  • Ground anchors are mostly used to improve the resistance capacity of retaining walls. The end of the anchor is connected to retaining wall through tendons and the forces in tendons are transferred to ground. In this study, we plan that the new anchor system increases the tension force in tendons and improves the pullout resistance characteristics of the system. In order to increase the pullout resistance capacity of existing anchor system, the new anchor system is made by attaching four steel sticks to the tip of anchor end. So the field test results showed that the pullout resistance capacity of the wedge-shaped ground anchor was acceptable to elastic displacement range.

  • PDF

무소음무진동 보보강공법 개발에 관한 연구(1) (Development of Retrofit Method for Beam Using Steel Plate Reinforced by Fiber Sheet (1))

  • 김우재;최종문;박상태;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.781-784
    • /
    • 2004
  • Method of Steel plate reinforced by fiber sheet is advantageous in the secure loading facility. For this method are a light weight and a high strength, the thickness of steel can be reduced Effects of composite system are depreciated when the thickness of steel is thin. This is the result of the difference of ductility ratio with steel plate. Steel plate reinforced by fiber sheets confirms the ability of transformation. This is the result of the property of steel materials Steel plate reinforced by fiber sheet didn't display an enough performance when theadhesives are epoxy rosin. This is the result of the slide of the surface of stee1. The adhesive ability is varied by the number and span of anchor bolts. There wasn't happening the separation between steel and epoxy. Thus the method used in combination with anchor and epoxy is best excellent. This is the result of the upward of accumulation effects Shearing force is in proportion to the number of bolts. But the ability of shearing force per one bolt is reducing. Thickness of steel plate reinforced by fiber sheet must be designed so that steel is endure before concrete is wreck.

  • PDF

앵커볼트 체결 Slit형 강판 보강 RC보의 전단거동에 관한 실험적 연구 (An Experimental Study on the Shear Behavior of Reinforced Concrete Beams Strengthened by Slit Type Steel Plates with Anchor Bolt)

  • 이춘호;정우동;심종석
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.703-710
    • /
    • 2010
  • 기존 구조물에서 RC보는 여러 가지 이유로 불충분한 전단에 대한 문제에 직면하게 된다. 전단내력이 부족한 RC보의 전단 보강방법으로 강판이 널리 사용되고 있다. 본 연구에서는 앵커볼트가 체결된 경사, 수직 슬릿형 강판의 표면부착에 의해 전단보강된 RC보에 대한 실험을 하였으며, 여러 형태의 앵커볼트 체결 슬릿형 강판으로 보강된 RC보에 대한 전단보강효과, 파괴모드 및 전단내력을 평가하는 것을 연구의 목적으로 하였다. 실험의 변수는 앵커볼트가 부착된 슬릿의 폭, 간격, 경사각 및 수직 길이로 하였다. 연구 결과, 에폭시 부착과 볼트 체결로 보강된 슬릿형 강판 실험체의 파괴 유형은 최대하중 시 전단파괴 모드로 나타났다. 휨균열은 보의 인장측에서 최초로 발생하였으며, 경사 균열은 전단스팬에서 발생하였다. 최종적으로 에폭시 부착과 볼트 체결로 보강된 슬릿형 강판에서의 급격한 박리현상은 지연되었으며, RC보의 본체로부터 완전하게 분리 되지는 않음을 알 수 있었다.