• 제목/요약/키워드: Steel Damper

검색결과 288건 처리시간 0.028초

조적채움벽 및 강재댐퍼 보강 RC 골조의 내진성능 평가에 관한 연구 (A Study on Seismic Performance Evaluation of RC Frame Retrofitted by Masonry Infill Wall and Steel Damper)

  • 이정한;양원직;강대언;송한범;오상훈;이원호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.129-132
    • /
    • 2005
  • The primary purpose of this investigation is to find out the shear behavior and the shear capacity of RC bare frames, brick-infilled RC frames, and damper-retrofitted RC frames and to evaluate the average shear strength of brick--infill wall. The main variables art the absence of brick infill wall and steel plate slit damper. The test results show that the shear capacity of specimen IF-DR is 2.8 times as high as that of the specimen BF and it presents the fact that the retrofitting effect and the possibility of RC frame reuse with changing the slit damper is verified. And the average shear strength of the brick infill wall is figured to be at $5.0 kgf/cm^2$.

  • PDF

Bridge flutter control using eccentric rotational actuators

  • Korlin, R.;Starossek, U.
    • Wind and Structures
    • /
    • 제16권4호
    • /
    • pp.323-340
    • /
    • 2013
  • An active mass damper system for flutter control of bridges is presented. Flutter stability of bridge structures is improved with the help of eccentric rotational actuators (ERA). By using a bridge girder model that moves in two degrees of freedom and is subjected to wind, the equations of motion of the controlled structure equipped with ERA are established. In order to take structural nonlinearities into consideration, flutter analysis is carried out by numerical simulation scheme based on a 4th-order Runge-Kutta algorithm. An example demonstrates the performance and efficiency of the proposed device. In comparison with known active mass dampers for flutter control, the movable eccentric mass damper and the rotational mass damper, the power demand is significantly reduced. This is of advantage for an implementation of the proposed device in real bridge girders. A preliminary design of a realization of ERA in a bridge girder is presented.

MOGA-Based Structural Design Method for Diagrid Structural Control System Subjected to Wind and Earthquake Loads

  • Kim, Hyun-Su;Kang, Joo-Won
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1598-1606
    • /
    • 2018
  • An integrated optimal structural design method for a diagrid structure and control device was developed. A multi-objective genetic algorithm was used and a 60-story diagrid building structure was developed as an example structure. Artificial wind and earthquake loads were generated to assess the wind-induced and seismic responses. A smart tuned mass damper (TMD) was used as a structural control system and an MR (magnetorheological) damper was employed to develop a smart TMD (STMD). The multi-objective genetic algorithm used five objectives including a reduction of the dynamic responses, additional stiffness and damping, mass of STMD, capacity of the MR damper for the integrated optimization of a diagrid structure and a STMD. From the proposed method, integrated optimal designs for the diagrid structure and STMD were obtained. The numerical simulation also showed that the STMD provided good control performance for reducing the wind-induced and seismic responses of a tall diagrid building structure.

건축 강구조물의 초기 부재단면 설계 및 내진성능에 관한 연구 (The Evaluation of Seismic Performance and the Design of Initial Member Sections for Architectural Steel Structures)

  • 이상주;이동우;한상을
    • 한국공간구조학회논문집
    • /
    • 제6권1호
    • /
    • pp.101-109
    • /
    • 2006
  • 내진 댐퍼 브레이스를 가진 강구조물은 브레이스가 지진입력에너지를 충분히 흡수함으로써 주요한 구성부재의 치명적인 피해를 현저하게 저감시키는 것이 가능하므로, 이 시스템 도입에 따른 거동특성 파악 및 적용성에 대한 연구가 활발히 진행되고 있다. 내진 댐퍼 브레이스를 가진 강구조물의 설계에 있어서는 구조물에 대한 브레이스의 강성비를 결정하여야 하며, 내진성능이 우수한 구조물을 설계하기 위해서는 강성비에 따른 구조물의 지진응답 특성을 파악할 필요가 있다. 본 연구에서는 소성설계에 기초하여 내진 댐퍼 브레이스의 수평 강성비에 따른 강구조물의 초기 부재단면를 설계하고, 지진응답해석을 수행하여 초기 부재단면 설계의 타당성 검토 및 동적거동 특성을 파악한다.

  • PDF

록킹 거동을 하는 꺽쇠형 강재 댐퍼의 횡변형 방지 효과 (The Effect of Preventing Lateral Deformation of the Clamp Type Steel Damper in Rocking Behavior)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.141-148
    • /
    • 2021
  • 본 연구에서는 강재 댐퍼의 횡변형을 방지할 수 있는 기술을 검토하여, 꺽쇠형 댐퍼에 적용하였다. 실험방법은 기존 연구와 같이 록킹 거동을 적용하였다. 평가변수는 횡변형 방지 상세 없는 기존 연구결과(SV-260)와 횡변형 방지 상세가 적용된 V-1과 V-1R이다. 여기서 V-1은 횡변형 방지상세가 댐퍼 하단부에 있으며, V-1R은 횡변형 방지상세가 하단부 및 상단부에 있다. 최대 하중 발현 시, 모멘트, 변위비 및 에너지 소산능력을 SV-260을 기준으로 상대 평가한 결과, SV-260 대비 V-1 및 V-1R의 최대모멘트는 1.22배, 1.36배 증가하였으며, 최대변위비는 2.41배, 2.92배 증가하였다. 또한 에너지 소산능력도 각각 1.39배, 1.52배 증가하였다. 따라서 강재 댐퍼에 횡변형 방지 상세를 적용한 것은 적절한 것으로 평가되었다.

강봉댐퍼로 보강한 기존 저층 철근콘크리트 필로티 건물의 내진성능 (Seismic Performance of an Existing Low-Rise Reinforced Concrete Piloti Building Retrofitted by Steel Rod Damper)

  • 백은림;오상훈;이상호
    • 한국지진공학회논문집
    • /
    • 제18권5호
    • /
    • pp.241-251
    • /
    • 2014
  • In this study, shaking table test was carried out to evaluate the seismic behavior and performance of low-rise reinforced concrete (RC) piloti structures with and without retrofit. The specimens were designed considering the characteristics of existing building with pilotis such as natural period, distribution factor of strength and stiffness between columns and core wall on the first soft story. The test for the non-retrofit specimen showed that damage was concentrated on the stiffer member on the same floor as the core wall failed by shear fracture whereas columns experienced slight flexural cracks. Considering the failure mode of the non-retrofit specimen, the retrofit method using steel rod damper was presented for improving the seismic performance of piloti structures. The results of the test for retrofit specimen revealed that the retrofit method was effective for controlling the damage as the main RC structural members were not destroyed and most of input energy was dissipated by hysteretic behavior of the damper.

Evaluation of performance of eccentric braced frame with friction damper

  • Vaseghi Amiri, J.;Navayinia, B.;Navaei, S.
    • Structural Engineering and Mechanics
    • /
    • 제39권5호
    • /
    • pp.717-732
    • /
    • 2011
  • Nonlinear dynamic analysis and evaluation of eccentric braced steel frames (EBF) equipped with friction damper (FD) is studied in this research. Previous studies about assessment of seismic performance of steel braced frame with FD have been generally limited to installing this device in confluence of cross in concentrically braced frame such chevron and x-bracing. Investigation is carried out with three types of steel frames namely 5, 10 and 15 storeys, representing the short, medium and high structures respectively in series of nonlinear dynamic analysis and 10 slip force values subjected to three different earthquake records. The proper place of FD, rather than providing them at all level is also studied in 15 storey frame. Four dimensionless indices namely roof displacement, base shear, dissipated energy and relative performance index (RPI) are determined in about 100 nonlinear dynamic analyses. Then average values of maximum roof displacement, base shear, energy dissipated and storey drift under three records for both EBF and EBF equipped with friction damper are obtained. The result indicates that FD reduces the response compared to EBF and is more efficient than EBF for taller storey frames.

TMD effectiveness for steel high-rise building subjected to wind or earthquake including soil-structure interaction

  • Kontoni, Denise-Penelope N.;Farghaly, Ahmed Abdelraheem
    • Wind and Structures
    • /
    • 제30권4호
    • /
    • pp.423-432
    • /
    • 2020
  • A steel high-rise building (HRB) with 15 stories was analyzed under the dynamic load of wind or four different earthquakes taking into consideration the effect of soil-structure interaction (SSI) and using tuned mass damper (TMD) devices to resist these types of dynamic loads. The behavior of the steel HRB as a lightweight structure subjected to dynamic loads is critical especially for wind load with effect maximum at the top of the building and reduced until the base of the building, while on the contrary for seismic load with effect maximum at the base and reduced until the top of the building. The TMDs as a successful passive resistance method against the effect of wind or earthquakes is used to mitigate their effects on the steel high-rise building. Lateral displacements, top accelerations and straining actions were computed to judge the effectiveness of the TMDs on the response of the steel HRB subjected to wind or earthquakes.

면외변형 구속에 따른 강재슬릿댐퍼의 구조성능에 관한 실험적 연구 (Experimental Study on Structural Performance of Steel Slit Damper According to Restrained Out-of-plane Deformation )

  • 김진우;권유진;최광용;김영주;박해용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권1호
    • /
    • pp.86-94
    • /
    • 2023
  • 본 연구에서는 강재 슬릿댐퍼를 대상으로 하여 면외 변형을 구속할 수 있는 보완상세를 제시하고, 제안상세 적용 유무와 댐퍼의 형상비를 변수로 하여 일정진폭 가력실험을 수행하였다. 실험결과에 따라 제안상세가 적용된 슬릿댐퍼의 반복이력은 설정된 변수 범위에서 모두 안정적인 방추형의 이력거동을 나타내었으며 종국거동까지 댐퍼의 면외변형은 관찰되지 않았다. 누적변형각 분석을 통해 제안상세가 적용된 댐퍼 시스템은 대조군에 비해 월등히 큰 소성변형능력을 확보할 수 있음을 확인하였다. 이러한 구조적 효과(구속패널효과)는 슬릿댐퍼의 형상비가 작을수록 크게 나타났다. 관련 국외기준을 참고하여 제안상세 적용유무에 따른 슬릿댐퍼의 피로곡선을 작성하고 예측곡선 제시를 위한 매개변수를 도출하였다. 본 연구의 결과를 토대로 향 후 다양한 종류의 제진장치의 구조성능에 대한 정량적인 비교가 가능할 것으로 판단된다.

Structural behaviour under wind loading of a 90 m steel chimney

  • Tranvik, Par;Alpsten, Goran
    • Wind and Structures
    • /
    • 제8권1호
    • /
    • pp.61-78
    • /
    • 2005
  • This paper presents results from an investigation of the structural behaviour of a very slender 90 m high steel chimney erected at V$\ddot{a}$xj$\ddot{o}$ in southern Sweden in 1995. The chimney is equipped with a mechanical friction-type damper at the top. Due to a mistake during erection and installation of the chimney the transport fixings of the damper were not released properly and the chimney developed extensive oscillations in the very first period of service. This caused a great number of fatigue cracks to occur within a few months of service. After the functioning of the damper had been restored and the fatigue cracks were repaired an extensive program was initiated in 1996 to monitor the structural behaviour of the chimney under wind loading. In the investigation data were collected for more than six years of continuous measurements and regular observations of the chimney. The data obtained have some general relevance with respect to wind data, behaviour of a slender structure under wind loading, and the effect of a mechanical damper. Also some theoretical studies were performed as part of the investigation of the chimney.