The Evaluation of Seismic Performance and the Design of Initial Member Sections for Architectural Steel Structures

건축 강구조물의 초기 부재단면 설계 및 내진성능에 관한 연구

  • Published : 2006.03.15

Abstract

An initial member sections of steel structures is selected by experience of expert building structural designers. And appropriate member section is designed by repeat calculation through structural analysis. Therefore an initial assumption of member section is necessary for saving the time for structural design and is important to acquire safety of building structures. Also brace damper are generally used to prevent or decrease stuctural damage by its hysteretic behavior in building structures subjected to strong earthquake. Based on plastic design, the initial section of members for architectural steel structures with hysteretic damper braces is presented and seismic effect of structural behavior by the ratio of damper stiffness to structural story stiffness is estimated in this paper.

내진 댐퍼 브레이스를 가진 강구조물은 브레이스가 지진입력에너지를 충분히 흡수함으로써 주요한 구성부재의 치명적인 피해를 현저하게 저감시키는 것이 가능하므로, 이 시스템 도입에 따른 거동특성 파악 및 적용성에 대한 연구가 활발히 진행되고 있다. 내진 댐퍼 브레이스를 가진 강구조물의 설계에 있어서는 구조물에 대한 브레이스의 강성비를 결정하여야 하며, 내진성능이 우수한 구조물을 설계하기 위해서는 강성비에 따른 구조물의 지진응답 특성을 파악할 필요가 있다. 본 연구에서는 소성설계에 기초하여 내진 댐퍼 브레이스의 수평 강성비에 따른 강구조물의 초기 부재단면를 설계하고, 지진응답해석을 수행하여 초기 부재단면 설계의 타당성 검토 및 동적거동 특성을 파악한다.

Keywords