Cable-pulley brace to improve story drift distribution of MRFs with large openings

  • Zahrai, Seyed Mehdi;Mousavi, Seyed Amin
    • Steel and Composite Structures
    • /
    • 제21권4호
    • /
    • pp.863-882
    • /
    • 2016
  • This study aims to introduce a new bracing system by which even super-wide frames with large openings can be braced. The proposed system, hereafter called Cable-Pulley Brace (CPB), is a tension-only bracing system with a rectilinear configuration. In CPB, a wire rope passes through a rectilinear path around the opening(s) and connects the lower corner of the frame to its opposite upper one. CPB is a secondary load resisting system with a nonlinear-elastic hysteretic behavior due to its initial pre-tension load. As a result, the required energy dissipation would be provided by the MRF itself, and the main intention of using CPB is to contribute to the initial and post-yield stiffness of the whole system. Using a stiffness calibration technique, optimum placement of the CPBs is discussed to yield a uniform displacement demand along the height of the structure. A displacement-based design procedure is proposed by which the MRF with CPB can be designed to achieve a uniform distribution of inter-story drifts with predefined values. Obtained results indicated that CPB leads to significant reductions in maximum and residual deformations of the MRF at the expense of minor increase in the maximum base shear and developed axial force demands in the columns. In the case of a typical 5-story residential building, compared to SMRF system, CPB system reduces maximum amounts of inter-story and residual drifts by 35% and 70%, respectively. Moreover, openings of the frame are not interrupted by the CPB. This is the most appealing feature of the proposed bracing system from architectural point of view.

성능수준 만족을 위한 가새헝 소성 감쇠기의 설계 (Design of Unbend Braces to Satisfy Given Performance Acceptance Criteria)

  • 김진구;김유경;최현훈
    • 한국지진공학회논문집
    • /
    • 제5권6호
    • /
    • pp.47-54
    • /
    • 2001
  • 가새형 소성 감쇠기는 에너지 소산 이력거동을 통해 강한 지진하중을 받는 구조물의 구조적 손상을 방지하거나 감소시킨다. 본 연구에서는 성능수준 만족을 위한 가새형 소성 금비기의 직접적인 설계 방법을 개발하였다. 많은 해석 시간이 요구되는 비선형 동적 시간이력해석 대신 비선형 정적해석법인 능력스펙트럼법을 이용하여 주어진 성능을 만족하기 위하여 필요한 유효 감쇠비를 구한 후 이를 이용하여 가새형 소성 감쇠기의 크기를 구하였다. 각 설계변수의 영향을 파악하기 위하여 단자유도계에서 구조물의 주기, 요구되는 탄성강도에 대한 항복강도의 비, 항목 후 강성비, 가새형 소성 감쇠기의 항복응력 등을 변수로 하여 해석을 수행하였다. 본 연구를 통해 제안된 방법을 5층과 10층 건물에 적용하여 검증하였다. 시간이력해석 결과, 제안된 방법에 따라 설계된 가새형 소성 감쇠기를 설치한 예제 구조물의 최대응답은 주어진 목표변위와 잘 일치하였다.

  • PDF

Numerical study on force transfer mechanism in through gusset plates of SCBFs with HSS columns & beams

  • Ebrahimi, S.;Zahrai, S.M.;Mirghaderi, S.R.
    • Steel and Composite Structures
    • /
    • 제31권6호
    • /
    • pp.541-558
    • /
    • 2019
  • In Special Concentrically Braced Frames (SCBFs), vertical and horizontal components of the brace force must be resisted by column and beam, respectively but normal force component existing at the gusset plate-to-column and beam interfaces, creates out-of-plane action making distortion in column and beam faces adjacent to the gusset plate. It is a main concern in Hollow Structural Section (HSS) columns and beams where their webs and gusset plate are not in the same plane. In this paper, a new gusset plate passing through the HSS columns and beams, named as through gusset plate, is proposed to study the force transfer mechanism in such gusset plates of SCBFs compared to the case with conventional gusset plates. For this purpose, twelve SCBFs with diagonal brace and HSS columns and twelve SCBFs with chevron brace and HSS columns and beams are considered. For each frame, two cases are considered, one with through gusset plates and the other with conventional ones. Based on numerical results, using through gusset plates prevents distortion and out-of-plane deformation at HSS column and beam faces adjacent to the gusset plate helping the entire column and beam cross-sections to resist respectively vertical and horizontal components of the brace force. Moreover, its application increases energy dissipation, lateral stiffness and strength around 28%, 40% and 32%, respectively, improving connection behavior and raising the resistance of the normal force components at the gusset plate-to-HSS column and beam interfaces to approximately 4 and 3.5 times, respectively. Finally, using such through gusset plates leads to better structural performance particularly for HSS columns and beams with larger width-to-thickness ratio elements.

Numerical investigation of cyclic performance of frames equipped with tube-in-tube buckling restrained braces

  • Maalek, Shahrokh;Heidary-Torkamani, Hamid;Pirooz, Moharram Dolatshahi;Naeeini, Seyed Taghi Omid
    • Steel and Composite Structures
    • /
    • 제30권3호
    • /
    • pp.201-215
    • /
    • 2019
  • In this research, the behavior of tube-in-tube BRBs (TiTBRBs) has been investigated. In a typical TiTBRB, the yielding core tube is located inside the outer restraining one to dissipate energy through extensive plastic deformation, while the outer restraining tube remains essentially elastic. With the aid of FE analyses, the monotonic and cyclic behavior of the proposed TiTBRBs have been studied as individual brace elements. Subsequently, a detailed finite element model of a representative single span-single story frame equipped with such a TiTBRB has been constructed and both monotonic and cyclic behavior of the proposed TiTBRBs have been explored under the application of the AISC loading protocol at the braced frame level. With the aid of backbone curves derived from the FE analyses, a simplified frame model has been developed and verified through comparison with the results of the detailed FE model. It has been shown that, the simplified model is capable of predicting closely the cyclic behavior of the TiTBRB frame and hence can be used for design purposes. Considering type of connection detail used in a frame, the TiTBRB member which behave satisfactorily at the brace element level under cyclic loading conditions, may suffer global buckling due to the flexural demand exerted from the frame to the brace member at its ends. The proposed TiTBRB suit tubular members of offshore structures and the application of such TiTBRB in a typical offshore platform has been introduced and studied in a single frame level using detailed FE model.

역V형 철골 중심가새골조의 정적/동적 지퍼기둥.설계법 (Staticand Dynamic Design of Zipper Columns in Inverted V Braced Steel Frames)

  • 이철호;김정재
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.733-740
    • /
    • 2006
  • Inverted V (or chevron) braced steel frames have been seen as being highly prone to soft story response once the compression brace buckles under earthquake loading. To salvage chevron braced frames. the concept of the zipper column was proposed many years ago such that the zipper column can redistribute the inelastic demand over the height of the building. However. rational design method for the zipper column has not been established yet. In this paper, a new dynamic design method for the zipper column was proposed by combining the refined physical braced model and modal pushover analysis. Inelastic dynamic analysis conducted on 6 story building model showed that the proposed method was more superior to the existing static design method and was very effective in improving seismic performance of chevron braced steel frames.

  • PDF

무보강 모살용접 각형강관 T형 접합부의 거동에 관한 실험적연구( II ) (An Experimental Study on the Behavior of Square Hollow Steel Section T-joints to be fillet-welded without Reinforcement)

  • 배규웅;문태섭
    • 한국강구조학회 논문집
    • /
    • 제8권3호통권28호
    • /
    • pp.35-45
    • /
    • 1996
  • The purpose of this paper is to investigate experimentally the strength and deformation of T-joints to improve the structural behavior of truss connection consisted in square hollow steel section. There are two-types to be changed in T-joint shape. One type is TP-series that a brace member is rotated to 45 degree, another type is TR-series that a chord member is rotated to 45 degree. The most important results obtained from the 2nd experiment on the T-joints is as follow; The yielding strength and initial stiffness of TP-series increase more than a current type(TS-series) in $0.6{\leq}{\beta}(d/D){\leq}0.7(0.85{\leq}{\beta}$'$(={\sqrt2}{\cdot}{\beta}){\leq}1.0)$.

  • PDF

중심가새골조의 순단면 파단에 관한 해석적 연구 (Analytical Study of Net Section Fracture in Special Concentrically Braced Frames)

  • 유정한
    • 한국강구조학회 논문집
    • /
    • 제21권1호
    • /
    • pp.63-70
    • /
    • 2009
  • 파괴모드는 저항력과 비탄성 변형 능력의 저하를 일으키는 균열이나 파단으로 귀결된다. 특수중심가새골조의 잠재적 파괴모드는 가새의 균열이나 파단, 가새나 거싯 플레이트의 순단면 파단, 거싯 플레이트용접의 균열, 볼트의 전단균열, 블록전단파단, 그리고 거싯 플레이트의 좌굴 등을 포함하고 있다. HSS 튜브가새는 특수중심가새골조에 자주 사용되고, 가새의 순단면 파단은 거싯 플레이트가 가새로 삽입되는 홈의 끝부분에 가새의 순단면을 통해 발생한다. 이 파괴모드는 인장파괴모드로 분류되고 급격한 강도저하와 취성적인 거동을 보인다. AISC 디자인 규준에선 순단면 보강을 요구하고 있다 (AISC 2001). 이 논문에서, 순단면 보강의 필요성에 대해 논의한다. 먼저, 미국 버클리대학교에서 수행됐던 순단면 파단실험을 유한요소모델을 이용한 이 실험의 모델링을 통해 소개한다. 실제 골조에서의 순단면 파단의 가능성을 조사하기 위해, 홈이 있는 중심가새골조를 유한요소법을 이용 모델링 하고, 인장지배의 근거리지진 이력을 적용시킨다. 이는 이력이 순단면 파단의 가장 중요한 인자라는 이전 해석 결과에서 기인한 것이다. 순단면 보강의 필요성과 인장지배의 근거리지진 이력의 영향에 대해 조사한다.

Cyclic testing of steel I-beams reinforced with GFRP

  • Egilmez, O. Ozgur;Yormaz, Doruk
    • Steel and Composite Structures
    • /
    • 제11권2호
    • /
    • pp.93-114
    • /
    • 2011
  • Flange and web local buckling in beam plastic hinge regions of steel moment frames can prevent beam-column connections from achieving adequate plastic rotations under earthquake-induced forces. This threat is especially valid for existing steel moment frame buildings with beams that lack adequate flange/web slenderness ratios. As the use of fiber reinforced polymers (FRP) have increased in strengthening and repair of steel members in recent years, using FRPs in stabilizing local instabilities have also attracted attention. Previous computational studies have shown that longitudinally oriented glass FRP (GFRP) strips may serve to moderately brace beam flanges against the occurrence of local buckling during plastic hinging. An experimental study was conducted at Izmir Institute of Technology investigating the effects of GFRP reinforcement on local buckling behavior of existing steel I-beams with flange slenderness ratios (FSR) exceeding the slenderness limits set forth in current seismic design specifications and modified by a bottom flange triangular welded haunch. Four European HE400AA steel beams with a depth/width ratio of 1.26 and FSR of 11.4 were cyclically loaded up to 4% rotation in a cantilever beam test set-up. Both bare beams and beams with GFRP sheets were tested in order to investigate the contribution of GFRP sheets in mitigating local flange buckling. Different configurations of GFRP sheets were considered. The tests have shown that GFRP reinforcement can moderately mitigate inelastic flange local buckling.

H형강 접합부를 갖는 목조 골조의 보강형식에 따른 구조성능 (Structural performance by strengthening types of wood frames using H shaped steel joints)

  • 김순철;문연준;양일승;박근홍
    • KIEAE Journal
    • /
    • 제8권3호
    • /
    • pp.77-83
    • /
    • 2008
  • The effective mixture of structural laminated timber and other materials is expected to extend the potentials of building structures because of the potentials to realize high performance in structural safety. The classical joint types using drift pin and bolts are occurred local failures due to the small bearing area. In result, new joints using H shaped steel were suggested in this research. The objective of this study is to evaluate elasto-plastic behaviors by strengthening types of wood frames with new joints connecting structural laminated timber with H shaped steel. A total of five specimens of about one-second scale were tested. Specimens had columns with 1,050 height and $84mm{\times}100mm$ section, and a beams with 1,950mm length and $130mm{\times}100mm$ section. Also, the specimens were stiffened by brace, hwang-toh brick, and autoclaved lightweight concrete. The results of the test showed that the specimen stiffened with autoclaved lightweight concrete was characterized by fairly good strength and stiffness than those of the other specimens. Initial stiffness of H-2.0D-NS specimen with 2 times inserting length of beam height showed 1.33 times than that of H-1.5D-NS specimen. However, the strength of H-2.0D-NS specimen has not improved too much than H-1.5D-NS specimen.

Improving the behavior of buckling restrained braces through obtaining optimum steel core length

  • Mirtaheri, Masoud;Sehat, Saeed;Nazeryan, Meissam
    • Structural Engineering and Mechanics
    • /
    • 제65권4호
    • /
    • pp.401-408
    • /
    • 2018
  • Concentric braced frames are commonly used in steel structures to withstand lateral forces. One of the drawbacks of these systems is the possibility that the braces are buckled under compressive loads, which leads to sudden reduction of the bearing capacity of the structure. To overcome this deficiency, the idea of the Buckling Restrained Brace (BRB) has been proposed in recent years. The length of a BRB steel core can have a significant effect on its overall behavior, since it directly influences the energy dissipation capability of the member. In this study, numerical methods have been utilized for investigation of the optimum length of BRB steel cores. For this purpose, BRBs with different lengths placed into several two-dimensional framing systems with various heights were considered. Then, the Response History Analysis (RHA) was performed, and finally, the optimum steel core length of BRBs and its effect on the responses of the overall system were investigated. The results show that the shortest length where failure does not occur is the best length that can be proposed as the optimum steel core length of BRBs. This length can be obtained through a formula which has been derived and verified in this study by both analytical and numerical methods.