• 제목/요약/키워드: Steel Base

검색결과 1,059건 처리시간 0.023초

A Newly Synthesized Schiff Base Derived from Condensation Reaction of 2,5-dichloroaniline and benzaldehyde: Its Applicability through Molecular Interaction on Mild Steel as an Acidic Corrosion Inhibitor by Using Electrochemical Techniques

  • Ozkir, Demet
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권1호
    • /
    • pp.37-54
    • /
    • 2019
  • A new organic Schiff base compound N-benzylidene-2,5-dichloroaniline (BDC) was synthesized and the structure of the Schiff base is illuminated by some spectroscopic techniques. In addition, whether it is an applicable inhibitor in the industrial field was examined by conventional methods such as linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization for different concentrations. The BDC concentration and temperature effects were surveyed for elucidating the inhibitive mechanism. The BDC molecules are adsorbed to surface of mild steel via the Langmuir isotherm. Atomic force (AFM) and scanning electron microscope (SEM) techniques were utilized to give insight into surface characterization.

용접 입열량에 따른 고질소 TiN 강재의 용접부 충격인성 및 미세조직 변화에 관한 연구 (A Study on the Impact Toughness and Microstructure change for High Nitrogen TiN Steel Alloy with Welding Heat Input.)

  • 권순두;이광학;박동환
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 추계학술발표대회 개요집
    • /
    • pp.123-124
    • /
    • 2004
  • This study was investigated on the impact toughness and microstructure of welded metal and heat affected zone for Hi Nitrogen TiN Steel. With welding procedures, welding heat input applied were 30, 79 and 264 kJ/cm. TiN steel has shown very small prior austenite grain size for all the welding heat input applied, which was considered to result from the effect of TiN particles. In case of single SAW and EGW welding, the dilution rate of base metal into the weld was not high, resulting that there were no significant effects of base metal chemical composition on the mechanical properties of welds. However, TSAW with double Ypreparation carried very high dilution rate so that TiN steel has impaired the toughness of weld metal because N content in the weld was increased through the dilution of base metal.

  • PDF

L형 갈고리 앵커볼트를 사용한 약축방향 노출형 주각부의 내진성능 평가 (Seismic Evaluation of Exposed Column-base Plate Weak-axis Connections Using L-shaped Hooked Anchor Bolts)

  • 임우영;유영찬
    • 한국강구조학회 논문집
    • /
    • 제29권4호
    • /
    • pp.269-280
    • /
    • 2017
  • 본 연구에서는 기존 소규모 철골조에서 나타나는 현장상세 노출형 주각부와 이를 보완한 상세를 가진 약축방향 주각부에 대한 반복 가력 실험을 통해 다양한 상세를 가진 약축방향 노출형 주각부의 내진성능을 평가하였다. 실험변수는 베이스 플레이트의 두께, 앵커볼트의 개수와 매립깊이, 그리고 리브 플레이트의 유무이다. 앵커볼트의 부착성능이 주각부 내진성능에 미치는 영향을 알아보기 위해 본 연구에서는 원형강봉과 나사산이 있는 L형 갈고리 앵커볼트를 사용하였다. 실험결과, 앵커볼트의 부착성능과 베이스 플레이트의 항복유무는 주각부의 에너지 소산능력에 영향을 끼치는 것으로 나타났다. 특히, 베이스 플레이트가 현행 기준에서 제시하고 있는 최소 두께를 만족하더라도 강재 기둥이 소성모멘트에 도달하기 전 베이스 플레이트가 항복할 경우, 주각부의 구조성능이 저하될 수 있는 소지가 있는 것으로 나타났다. 하지만, 현행 구조기준에 따라 접합부 성능을 조사한 결과, 제안된 약축방향 주각부 상세는 부분 강접합으로 가정할 수 있는 것으로 나타났다. 기존의 원형강봉에 비해 부착성능이 우수한 나사산이 있는 L형 갈고리 앵커볼트는 반강접 노출형 주각부에 사용가능할 것으로 판단된다.

에너지 흡수형 고력볼트를 사용한 철골 주각부의 동적 거동 특성에 관한 연구 (A Study on the Dynamic Behavior Characteristics of Steel Column Base using Energy Absorbtion High Strength Bolt)

  • 이승재;박재성
    • 한국공간구조학회논문집
    • /
    • 제11권3호
    • /
    • pp.67-76
    • /
    • 2011
  • 주각부는 상부의 강구조와 철근콘크리트조 기초의 접합부로써 매우 중요한 부분이다. 현재 국내외 강구조 골조 공사에서 사용되는 주각부의 형식은 크게 구분하여 노출형 주각부 근권형 주각부, 매입형 주각부라고 할 수 있다. 이 중에서 부재의 재사용 및 재활용을 최우선으로 고려한다면 노출형 주각부가 가장 유리하다. 본 연구에서는 이러한 노출형 주각부의 시공 성능 및 역학적 성능을 획기적으로 개선할 수 있는 형태의 강구조 선형상 노출형 주각부를 개발하고, 구조 성능 평가를 위한 탄소성 재하실험을 수행하였다. 그 결과 개발된 신형상 노출형 주각부는 수평 방향과 수직 방향의 시공 오차를 현장에서 간단히 흡수하여 기존 노출형 주각부의 시공 불량을 사전에 방지함으로써 구조 성능을 발휘한다. 또한 에너지 흡수형 고력볼트를 사용함으로써 변형 성능이 증가함을 알 수 있었다.

Rotational behavior of exposed column bases with different base plate thickness

  • Cui, Yao;Wang, Fengzhi;Li, Hao;Yamada, Satoshi
    • Steel and Composite Structures
    • /
    • 제32권4호
    • /
    • pp.497-507
    • /
    • 2019
  • Exposed column base connections are used in low- to mid-rise steel moment resisting frames. This paper is to investigate the effect of the base plate thickness on the exposed column base connection strength, stiffness, and energy dissipation. Five specimens with different base plate thickness were numerically modelled using ABAQUS software. The numerical model is able to reproduce the key characteristics of the experimental response. Based on the numerical analysis, the critical base plate thickness to identify the base plate and anchor rod yield mechanism is proposed. For the connection with base plate yield mechanism, the resisting moment is carried by the flexural bending of the base plate. Yield lines in the base plate on the tension side and compression side are illustrated, respectively. This type of connection exhibits a relatively large energy dissipation. For the connection with anchor rod yield mechanism, the moment is resisted through a combination of bearing stresses of concrete foundation on the compression side and tensile forces in the anchor rods on the tension side. This type of connection exhibits self-centering behavior and shows higher initial stiffness and bending strength. In addition, the methods to predict the moment resistance of the connection with different yield mechanisms are presented. And the evaluated moment resistances agree well with the values obtained from the FEM model.

Investigation on Ultimate Strength of STS304L Stainless Steel Welded Connection with Base Metal Fracture Using Finite Element Analysis

  • Lee, HooChang;Kim, TaeSoo;Hwang, BoKyung;Cho, TaeJun
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1139-1152
    • /
    • 2018
  • Many studies on the application of stainless steels as structural materials in buildings and infra-structures have been performed thanks to superior characteristics of corrosion resistance, fire resistance and aesthetic appeal. Experimental investigation to estimate the ultimate strength and fracture mode of the fillet-welded connections of cold-formed austenitic stainless steel (STS304L) with better intergranular corrosion resistance than that of austenitic stainless steel, STS304 commonly used has carried out by authors. Specimens were fabricated to fail by base metal fracture not weld metal fracture with main variables of weld lengths according to loading direction. All specimens showed a block shear fracture mode. In this paper, finite element analysis model was developed to predict the ultimate behaviors of welded connection and its validity was verified through the comparison with test results. Since the block shear behavior of welded connection due to stress triaxiality and shear-lag effects is different from that of bolted connection, stress and strain distributions in the critical path of tensile and shear fracture section were investigated. Test and analysis strengths were compared with those by current design specifications such as AISC, EC3 and existing researcher's proposed equations. In addition, through parametric analysis with extended variables, the conditions of end distance and longitudinal weld length for block shear fracture and tensile fracture were suggested.

Analysis and design of demountable circular CFST column-base connections

  • Li, Dongxu;Wang, Jia;Uy, Brian;Aslani, Farhad;Patel, Vipul
    • Steel and Composite Structures
    • /
    • 제28권5호
    • /
    • pp.559-571
    • /
    • 2018
  • In current engineering practice, circular concrete-filled steel tubular (CFST) columns have been used as effective structural components due to their significant structural and economic benefits. To apply these structural components into steel-concrete composite moment resisting frames, increasing number of research into the column-base connections of circular CFST columns have been found. However, most of the previous research focused on the strength, rigidity and seismic resisting performance of the circular CFST column-base connections. The present paper attempts to investigate the demountability of bolted circular CFST column-base connections using the finite element method. The developed finite element models take into account the effects of material and geometric nonlinearities; the accuracy of proposed models is validated through comparison against independent experimental results. The mechanical performance of CFST column-base connections with both permanent and demountable design details are compared with the developed finite element models. Parametric studies are further carried out to examine the effects of design parameters on the behaviour of demountable circular CFST column-base connections. Moreover, the initial stiffness and moment capacity of such demountable connections are compared with the existing codes of practice. The comparison results indicate that an improved prediction method of the initial stiffness for these connections should be developed.

기초지반강성을 고려한 철골 건축구조물의 비선형 지진해석 (Nonlinear Seismic Analysis of Steel Buildings Considering the Stiffnesses of the Foundation-Soil System)

  • 오영희;김용석
    • 한국강구조학회 논문집
    • /
    • 제18권2호
    • /
    • pp.173-180
    • /
    • 2006
  • 구조물의 지진응답은 기초지반조건의 영향을 받는다. 이 연구에서는 고정지반과 연약지반을 고려한 3, 5, 7층 철골 건축구조물의 밑면전단력을 산정하기 위해 선형 시간이력지진해석과 비선형 Pushover 정적지진해석을 수행하였다. 등가정적강성식으로 구한 기초지반강성은 SAP2000의 Link 요소 중 Damper 요소를 사용하여 입력하였다. 범용구조해석 프로그램 SAP2000에 의한 시간이력으로 구한 철골건축구조물의 밑면전단력을 국내내진설계기준, UBC-97 설계응답스펙트럼, Pushover 정적 비선형해석으로 구한 밑면전단력과 비교하였다. 중력하중과 풍하중으로 설계된 철골 건축구조물은 0.11g의 중진에 대해 탄성응답을 보였고, 탄성 연약지반에서 구조물-지반의 상호작용과 지반 증폭에 의해 구조물의 변위와 밑면전단력이 증가되었다. 따라서, 중약진 지역에서의 건축구조물은 연약지반의 특성을 고려하여 탄성지진해석을 수행하는 것이 더 합리적이다.

HSLA-100강 및 HY-100강의 응력제거처리 균열에 관한 연구 (A Study on the Stress Relief Cracking of HSLA-100 and HY-100 steels)

  • 박태원;심인옥;김영우;강정윤
    • Journal of Welding and Joining
    • /
    • 제14권3호
    • /
    • pp.48-57
    • /
    • 1996
  • A study was made to examine the characteristics of base metal and stress relief cracking(SRC) of heat affected zone(HAZ) for HY-100 and Cu-bearing HSLA-100 steels. The Gleeble thermal/mechanical simulator was used to simulate the SRC/HAZ. The details of mechanical properties of base plate and SRC tested specimens were studied by impact test, optical microscopy and scanning electron microscopy. The specimens were aged at $650^{\circ}C$ for HSLA-100 steel and at $660^{\circ}C$ for HY-100 steel and thermal cycled from $1350^{\circ}C$ to $25^{\circ}C$ with a cooling time of $\Delta$t_${800^{circ}C/500^{circ}C}$=21sec. corresponds to the heat input of 30kJ/cm. The thermal cycled specimens were stressed to a predetermined level of 248~600MPa and then reheated to the stress relief temperatures of $570~620^{\circ}C$. The time to failure$(t_f)$ at a given stress level was used as a measure of SRC susceptibility. The strength, elongation and impact toughness of base plate were greater in HSLA-100 steel than in HY-100 steel. The time to failure was decreased with increasing temperature and/or stress. HSLA-100 steel was more susceptible to stress relief cracking than HY-100 steel under same conditions. It is thought to be resulted from the precipitation of $\varepsilon$-Cu phase by dynamic self diffusion of solute atoms. By the precipitation of $\varepsilon$-Cu phase, the differential strengthening of grain interior relative to grain boundary may be greater in the Cu-bearing HSLA-100 steel than in HY-100 steel. Therefore, greater strain concentration at grain boundary of HSLA-100 steel results in the increased SRC susceptibility. The activation energies for SRC of HSLA-100 steel are 103.9kcal/mal for 387MPa and 87.6kcal/mol for 437MPa and that of HY-100 steel is 129.2kcal/mol for 437MPa.

  • PDF

조선용 고장력강재와 보통강도강재간의 용접부위의 부식피로와 전기방식에 관한 연구 (A study on the corrosion fatigue and cathodic protection of the welded zone between high tensile strength steel and general strength steel used for the shipbuilding)

  • 전대희;김원녕;이의호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.39-50
    • /
    • 1984
  • The plane bending corrosion fatigue test was performed on the welded zone between SM58 steel plate and SM41 steel plate jointed with submerged arc welding in the air and in the natural sea water with various conditions. The main results obtained from the test are summarized as follows: 1) The welded zone of the steel plates has the lowest impact strength and the highest electrode potential, but the hardness was mediate of SM58 base and SM41 base. 2) The cathodic protection of the welded zone was also effective for the plane bending corrosion fatigue, and the optimum protection potential of the welded zone was -1,000 mV SCE. 3) The corrosion fatigue strength under the various stress conditions of the steel plate could be estimated and also the require safety factors on the design could be obtained from the plane bending fatigue limit diagram.

  • PDF