• Title/Summary/Keyword: Steel Bar

Search Result 914, Processing Time 0.301 seconds

Static Shear Strength of Cast-in Anchors with Stirrup Reinforcement (스터럽 보강 선설치 앵커의 정적 전단하중에 대한 저항 강도)

  • Park, Yong Myung;Jo, Sung Hoon;Kim, Tae Hyung;Kang, Choong Hyun;Kim, Jae Bong
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.1
    • /
    • pp.1-12
    • /
    • 2016
  • An experimental study was conducted to evaluate the static shear strength of stirrup-reinforced cast-in anchors. The test parameters considered herein are an existence of front bearing bar and concrete crack. M36 anchor was used with an edge distance of 180mm. HD-10 bars were used for all reinforcing bars and the stirrups were placed with 100mm spacing. The shear resistance increased by 16% when the front bearing bar was installed. Meanwhile, the resistance reduced only 5% in the cracked concrete compared with the uncracked concrete. The test results showed that ACI 318 and ETAG 001 specifications could estimate the shear strength of stirrup-reinforced anchors conservatively and a rational method was proposed. A consideration on the fracture strength of stirrup-reinforced anchor is also given.

Evaluation of Axial Behavior of Strengthened Columns according to Different Peripheral Closed Hoops in Jacket Section (확대단면에서 폐쇄형 외부 띠철근 배근 방법에 따른 보강기둥의 중심축하중 거동 평가)

  • Hwang, Yong-Ha;Yang, Keun-Hyeok;Sim, Jae-Il;Choi, Yong-Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.139-146
    • /
    • 2019
  • This study examined the effect of various arrangement methods for forming peripheral closed hoops in the jacket section on the axial behavior of section enlargement strengthening columns. Four types of peripheral closed hoops arranged in the jacket section were prepared as follows: 1) Closed connection of prefabricated bar units (column P); 2) V-clip installation across the overlapped legs of channel-type bars (column V); 3) Use of glass fiber mesh for an alternative of steel bars (column F); and 4) combination of prefabricated bar units and glass fiber mesh (column PF). The V-clip is designed to form the closed hoops in the jacket section using the overlapped channel-type bars, preventing the opening of the channel bar legs. The glass fiber mesh is to examine the feasibility to apply for closed hoops in the jacket section as an alternative for steel bars, considering the easy construction. In the jacket section of all the strengthened columns, V-ties were arranged for supplementary ties, avoiding the interruption of the existing column. The axial stiffness and strength of the strengthened columns were insignificantly affected by the arrangement methods of closed hoops in the jacket section. The axial ductility ratio of the strengthened columns P, V, and PF was enhanced more than twice of that measured in the non-seismic existing column. However, the column F exhibited a lower ductility than the other strengthened columns because of the fracture of the mesh at the ultimate strength of the column. The V-clip approach was favorable to enhance the ductility of the strengthened column, preventing the opening of the legs of channel-type bars.

Experimental Study on the Flexural Behavior of Inverted T-Shaped Steel·Concrete Composite Deck for Bridges (역T형강·콘크리트 합성바닥판의 휨거동에 관한 실험적 연구)

  • Kim, Sung Hoon;Park, Young Hoon;Lee, Seung Yong;Choi, Jun Hyeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.331-340
    • /
    • 2008
  • This study is to suggest the details of new concept of bridge deck. Experimental studies on the behavior of a inverted T-shaped steelconcrete composite deck were carried out. The part of inverted T-shaped steel is embedded in concrete. Reinforced concrete deck specimen and composite deck specimens were fabricated and static bending fracture tests were conducted. The ultimate strength and fracture strength of specimens were evaluated. The effects of shear hole crossing bars of composite deck were also analyzed. From the results of experiments, composite deck with shear hole crossing bar increased shear strength, and showed typical tensile failure. Ultimate strength and fracture strength of composite deck with shear hole crossing bar are higher than those of reinforced concrete deck. The displacement of composite deck is higher than that of reinforced concrete deck.

A Study on the Basic Development Length of GFRP Rebar With Ribs (이형 GFRP 보강근의 기본정착길이에 대한 연구)

  • Moon, Do Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.5A
    • /
    • pp.485-493
    • /
    • 2010
  • GFRP rebar with ribs resemble those of deformed steel rebar was developed in 2005. It was reported that ribs of the GFRP rebar were sheared off due to the lower shear strength of polymer. In this study, the basic development length of the GFRP rebar was investigated through pull-out tests, models specified in ACI440.1R-03 and -06, and empirical model derived by Cosenza et al. (2002). As a results of pull-out tests, the critical embeddment length, which is defined as the length when failure mode is changed from pull-out to bar fracture, was 20 times of bar diameter for GFRP rebar and was 15 times for steel rebar. It is believed that the basic development of the GFRP rebar is 21 times of bar diameter, which is determined from the application of average bond strength into the model equation specified in ACI440.1R-03. Compared to the model equation in ACI440.1R-06, that in ACI440.1R-03 is recommendable for design purpose. The Cosenza et al.'s model underestimates the basic development length of the GFRP rebar.

Behavior of Reinforcement Ratio on Concrete Beams Reinforced with Lab Spliced GFRP Bar (GFRP 보강근으로 겹이음된 콘크리트 보의 보강비에 따른 거동특성)

  • Choi, Yun Cheul;Park, Keum Sung;Choi, Hyun Ki;Choi, Chang Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.67-76
    • /
    • 2011
  • The use of glass-fiber-reinforced polymer (GFRP) bars in reinforced concrete (RC) structures has emerged as an alternative to traditional RC due to the corrosion of steel in aggressive environments. Although the number of analytical and experimental studies on RC beams with GFRP reinforcement has increased in recent decades, it is still lower than the number of such studies related to steel RC structures. This paper presents the experimental moment deflection relations of GFRP reinforced beam which are spliced. Test variables were different reinforcement ratio and cover thickness of GFRP rebars. Seven concrete beams reinforced with steel GFRP re-Bars were tested. All the specimens had a span of 4000mm, provided with 12.7mm nominal diameter steel and GFRP rebars. All test specimens were tested under 2-point loads so that the spliced region be subject to constant moment. The experimental results show that the ultimate moment capacity of beam increasing of the reinforcement ratio. Failure mode of these specimens was sensitively vary according to the reinforcement ratio. The change of beam effective depth, which was caused by cover thickness variation, controlled the maximum strength and deflection because of cover spalling in tension face.

A Modified Technique for Pectus Carinatum Surgery: Partial Costal Cartilage Resection and Pre-sternal Compression with Using a Stainless Steel Bar (새가슴 수술의 변형수기: 부분 늑연골 절제와 스테인리스 금속막대를 이용한 흉골압박)

  • Lee, Seock-Yeol;Oh, Jae-Yun;Lee, Seung-Jin;Lee, Chol-Sae
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.742-746
    • /
    • 2008
  • Background: The surgical treatment of pectus carinatum is usually a modified Ravitch operation that consists of complete costal cartilage resection and sternal wedge osteotomy. We tried a simple and easy technique that is resection of only deformed, protruded costal cartilage and pre-sternal compression with using a stainless steel bar and this is done without sternal osteotomy. Therefore, we performed partial cartilage resection and pre-sternal compression with a stainless steel bar and we observed the effects and the efficiency of treatment. Material and Method: From July, 2006 to June, 2008, 10 patients with pectus carinatum underwent our modified technique of pectus carinatum surgery. The effects of surgery and the complications were reviewed. Result: 5 patients with only pectus carinatum underwent our modified technique of pectus carinatum surgery. 5 patients with pectus carinatum and pectus excavatum underwent our modified technique of pectus carinatum surgery and Nuss surgery. The mean patient age was 13.4+3.3 years old. The mean operation time was 137.6+22.9 minutes for the pectus carinatum patients and 234.0+36.5 minutes for the pectus carinatum and pectus excavatum patients. The mean length of hospitalization was 11.8+1.0 days. The Haller pectus index of pectus carinatum was $2.10{\pm}0.21$ preoperatively and this was increased to $2.53{\pm}0.07$ postoperatively. The only complication was simple partial wound disruption in 1 patient. Conclusion: We performed partial cartilage resection and pre-sternal compression with a stainless steel bar in 10 patients with pectus carinatum and its effects were good. Our modified technique of pectus carinatum is easy and simple as compared with the Ravitch operation. But removal of the stainless steel bar has not yet been performed for these patients and long-term follow up is needed to accurately evaluate the. effects of this surgery in many surgical cases.

Introduction of Non-Heat Treated Steel Wire Rod Developed by POSCO (비조질 선재 제품에 대한 소개 및 최근 연구개발 동향)

  • Lee, You-Hwan;Kim, Dong-Hyun;Lee, Sang-Yoon;Lee, Duk-Lak
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.137-138
    • /
    • 2009
  • There is a growing interest to replace the commercial steels with non-heat treated steels, which does not involve the spheroidization and quenching-tempering treatment in the steel-wire industry production. However, non-heat treated steels should satisfy high strength and good formability without performing heat treatment. Therefore, it is important to investigate optimum materials showing a good combination of strength and formability after the cold drawing process. In this presentation, non-heat treated steel wire rod produced by POSCO will be introduced and discussed on detail technical concepts.

  • PDF

Finite Element Model Considering the Bond-Slip Effect (부착슬립 효과를 고려한 유한요소 모델)

  • 최창근;곽효경
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1991.10a
    • /
    • pp.17-22
    • /
    • 1991
  • An accurate and efficient analytical model describing the bond effect between reinforcing steel and concrete without taking the double nodes is presented. To increase the efficiency of the solution and reduce the number of degrees of freedom, the reinforcing bar elements are considered to be embedded in the connote elements. Relative douses of freedom accounting for the relative slip between reinforcing steel and concrete are condensed out during the stiffness formation phase. However, these degrees of freedom Can be taken into account explicitly by solving the constructed global equilibrium equation for each reinforcing steel. The usefulness of proposed model is established through the comparison with the experimental data subjected on push and push-pull loadings.

  • PDF

Structural behavior of R/C Slabs Strengthened with Steel Plate, Carbon fiber sheets, and Carbon Fiber Laminate. (강판, 탄소섬유쉬트, 탄소섬유판으로 휨보강된 철근콘크리트 슬래브의 구조적 거동)

  • Lee, Young-Jea;Moon, Heui-Jeung;Lee, Kyung-Un;Chung, Lan;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.601-606
    • /
    • 1998
  • In recent years, strengthening by steel plate, carbon fiber sheets, and carbon fiber laminate in spotlighted in order to repair and rehabilitation of R/C slabs. In this study, 3 method of rehabilitation are analyzed from the tests. Test parameters are the width of cracks, the method of repair and rehabilitation, the magnitude of pre-load. Deflection, failure load, strains of reinforcing bar, strains of sheet and plates are measured during tests. The failure mode and separption load analyzed from these measured data.

  • PDF

Effect of degree of corrosion on the mechanical properties of rebar (철근부식정도가 철근의 역학적 특성에 미치는 영향)

  • Cheong, Hai-Moon;Lee, Chan-Young;Ahn, Tas-Song;Tae, Sung-Ho;Lee, Han-Seung;Kang, In-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.257-260
    • /
    • 2006
  • This paper reports results of a study conducted to assess the effect of degree of corrosion of reinforcing steel bar on their mechanical properties. Reinforcing steel bars, 13mm in diameter, that were corroded by electrically accelerated corrosion method in concrete specimens were removed and tested in tension. Results indicated that the level of reinforcement corrosion influenced yield point, the tensile strength and elongation of steel bars.

  • PDF