• Title/Summary/Keyword: Steam efficiency

검색결과 444건 처리시간 0.028초

A Study on the Incentive-based Strategies for Utilization of Thermoelectric Power Plant Hot Waste Water: Focusing on the Analysis of Levelized Cost of Energy(LCOE) (발전소 온배수열 활용사업의 경제적 유인제도 연구 : 에너지균등화비용(LCOE) 분석을 중심으로)

  • Nam, Tae-Sub;Lee, Kwan-Young;Kim, Kyung Nam
    • Journal of Energy Engineering
    • /
    • 제25권1호
    • /
    • pp.29-42
    • /
    • 2016
  • This study analyzes the economic efficiency of utilizing hot waste water at a thermoelectric power plant, which is part of recent projects supported by the Korean government to foster new energy industry. The author proposes an institution that provides economic incentives to promote the project. Based on a method of calculating Levelized cost of energy (LCOE), this study finds that the LCOE of using hot waste water at power plants is higher than that of oil boiler, biomass and a power plant's auxiliary steam but similar to that of the geothermal system. Also, according to sensitivity analysis on the LCOE of each element in the system of using hot waste water, a distance of heat supply is most sensitive. Therefore, this study shows that when the government devises an incentive-based institution to expand the project of utilizing hot waste water, it is necessary to establish Renewable Energy Certificate (REC) weights that are differentiated by a distance of heat supply.

Comparison of Real Time Water Soluble Organic Carbon Measurements by Two PILS-TOC Analyzers (PILS-TOC를 이용한 실시간 대기 중 수용성 유기탄소 비교 측정)

  • Park, Da-Jeong;Kang, Seokwon;Lee, Taehyoung;Shin, Hye-Jung;Shon, Zang-Ho;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제32권6호
    • /
    • pp.633-641
    • /
    • 2016
  • Two identical Particle Into Liquid Samplers-Total Organic Carbon (PILS-TOC) were operated to measure fine particle Water Soluble Organic Carbon (WSOC) for one week on Feb. in 2016. The dual instrument operations provided validated WSOC concentrations to have a continuous WSOC measurement during the sample analysis period. Both PILS-TOC instruments were operated downstream of an carbon denuder to remove positive adsorption artifacts associated with semi-volatile organic compounds. Comparison of WSOC showed good agreement each other. The linear regression had a coefficient of determination ($r^2$) of 0.92 and a regression slope of 1.01 for the first period. The lower collection efficiency due to lower steam temperature is discussed. In addition, the potential primary source related to WSOC based on the comparison of black carbon (BC) concentrations is explained. The results of good agreement between two PILS-TOC measurements can provide the validation of WSOC cooperations and knowledge regarding the origins of WSOC and their behaviors.

Development of Asynchronous Blocking Algorithm through Asynchronous Case Study of Steam Turbine Generator (스팀터빈 발전기 비동기 투입 사례연구를 통한 비동기 방지 알고리즘 개발)

  • Lee, Jong-Hweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제61권10호
    • /
    • pp.1542-1547
    • /
    • 2012
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. When calculation method of protection settings and logic for protection of generator asynchronization will be recommended, a distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection, this paper describes an improved backup protection coordination scheme using a new logic that will be suggested.

Effect of Oil Supply Direction on Power Loss and Bearing Temperature of Elliptical Bearing (오일공급 방향에 따른 타원형 베어링 손실 및 온도 특성)

  • Bang, Kyungbo;Choi, Yonghoon;Cho, Yongju
    • Tribology and Lubricants
    • /
    • 제34권4호
    • /
    • pp.138-145
    • /
    • 2018
  • Elliptical bearings are widely used for large steam turbines owing to their excellent load carrying capacity and good dynamic stability. Power loss in bearings is an extremely important parameter, especially for high turbine capacities. Optimization of operation conditions and design variables such as bearing clearance and bearing length can reduce the power loss in elliptical bearings. Although changes in the oil supply method have served to increase the efficiency of the tilting pad journal bearing, it has not explicitly improved elliptical bearings. In this study, we verify the static characteristics of an elliptical bearing by changing the direction of oil supply. We evaluate the bearing power loss and bearing metal temperature, and compare the bearing performance and reliability in different test cases. The direction of oil supply is $90^{\circ}$ (9 o'clock) and $270^{\circ}$ (3 o'clock) when the rotor rotates in a counterclockwise direction. We use an elliptical bearing with an inner diameter and active length of 220.30 and 110.00 mm, respectively. Bearing power loss and bearing metal temperatures are measured and evaluated by rotor rotational speed, oil flow rate, and bearing load. The results reveal a 20 reduction in the power loss when the direction of oil supply is 90. Furthermore, the oil film on the upper part of the bearing has a high temperature when the direction of oil supply is $90^{\circ}$. In contrast, when the direction of oil supply is $270^{\circ}$, the oil film on the upper part of the bearing is relatively cold.

Adaptive Multi-stream Transmission Technique based on SPIHT Video Signal (SPIHT기반 비디오 신호의 적응적 멀티스트림 전송기법)

  • 강경원;정태일;류권열;권기룡;문광석
    • Journal of Korea Multimedia Society
    • /
    • 제5권6호
    • /
    • pp.697-703
    • /
    • 2002
  • In this paper, we propose the adaptive multi stream transmission technique based on SPIHT video signal for the highest quality service over the current Internet that does not guarantee QoS. In addition to the reliable transmission of the video stream over the asynchronous packet network, the proposed approach provides the transmission using the adaptive frame pattern control and multi steam over the TCP for continuous replay. The adaptive frame pattern control makes the transmission date scalable in accordance with the client's buffer status. Apart from this, the multi stream transmission improves the efficiency of video stream, and is robust to the network jitter problem, and maximally utilizes the bandwidth of the client's. As a result of the experiment, the DR(delay ratio) in the proposed adaptive multi-stream transmission is more close to zero than in the existing signal stream transmission, which enables the best-efforts service to be implemented.

  • PDF

Industrial-scale biological treatment of Chinese nutgall processing wastewater by combined expanded granular sludge bed and bio-contact oxidation

  • Wu, Yundong;Zhou, Kanggen;Dong, Shuyu;Yu, Wei;Liang, Chunsheng
    • Environmental Engineering Research
    • /
    • 제20권4호
    • /
    • pp.336-341
    • /
    • 2015
  • The industrial-scale biological treatment of Chinese nutgall processing wastewater was conducted with a $200m^3$ expanded granular sludge bed reactor and a $900m^3$ bio-contact oxidation reactor. The temperature of the two reactors was controlled under mesophilic conditions ($32-40^{\circ}C$), through changing the proportion of the dilution water, which was composed of steam condensation water and residual circulating water. The effluent COD, gallic acid, chroma, total nitrogen, total phosphorus levels and pH of both the expanded granular sludge bed and bio-contact oxidation reactors were monitored. In addition, the redox potential in the expanded granular sludge bed was recorded. The total COD removal efficiency was 87.257% when the influent COD concentration was $14\;251{\pm}3\;148mg/L$, and the ratio of wastewater: dilution water was 1:5. The removal efficiencies of gallic acid, chroma, total nitrogen, and total phosphorus were 72.221%, 43.940%, 64.151% and 39.316%, respectively. The effluent pH increased in either the expanded granular sludge bed reactor or the bio-contact oxidation reactor during the operation. The redox potential in the expanded granular sludge bed varied between -367 mV and -435 mV. The results indicate that the combined process was suitable for treating Chinese nutgall processing wastewater.

Estimation of Greenhouse Gas (GHG) Reductions from Bioenergy (Biogas, Biomass): A Case Study of South Korea (바이오에너지 (바이오가스, 바이오매스) 기술의 온실가스 감축산정: 국내를 대상으로)

  • Jung, Jaehyung;Kim, Kiman
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제33권4호
    • /
    • pp.393-402
    • /
    • 2017
  • In this study, greenhouse gas (GHG) reductions from bioenergy (biogas, biomass) have been estimated in Korea, 2015. This study for construction of reduction inventories as direct and indirect reduction sources was derived from IPCC 2006 guidelines for national greenhouse gas inventories, guidelines for local government greenhouse inventories published in 2016, also purchased electricity and steam indirect emission factors obtained from KPX, GIR respectively. As a result, the annual GHG reductions were estimated as $1,860,000tonCO_{2eq}$ accounting for 76.8% of direct reduction (scope 1) and 23.2% of indirect reduction (scope 2). Estimation of individual greenhouse gases (GHGs) from biogas appeared that $CO_2$, $CH_4$, $N_2O$ were $90,000tonCO_2$ (5.5%), $55,000tonCH_4$ (94.5%), $0.3tonN_2O$ (0.004%), respectively. In addition, biomass was $250,000tonCO_2$ (107%), $-300tonCH_4$ (-3.2%), $-33tonN_2O$ (-3.9%). For understanding the values of estimation method levels, field data (this study) appeared to be approximately 85.47% compared to installed capacity. In details, biogas and biomass resulting from field data showed to be 76%, 74% compared to installed capacity, respectively. In the comparison of this study and CDM project with GHG reduction unit per year installed capacity, this study showed as 42% level versus CDM project. Scenario analysis of GHG reductions potential from bioenergy was analyzed that generation efficiency, availability and cumulative distribution were significantly effective on reducing GHG.

Performance of Ru-based Preferential Oxidation Catalyst and Natural Gas Fuel Processing System for 1 kW Class PEMFCs System (Ru계 촉매의 CO 선택적 산화 반응 및 1 kW급 천연가스 연료처리 시스템의 성능 연구)

  • Seo, Yu-Taek;Seo, Dong-Joo;Seo, Young-Seog;Roh, Hyun-Seog;Jeong, Jin-Hyeok;Yoon, Wang-Lai
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제17권3호
    • /
    • pp.293-300
    • /
    • 2006
  • KIER has been developing a Ru-based preferential oxidation catalysts and a novel fuel processing system to provide hydrogen rich gas to residential PEMFCs system. The catalytic activity of Ru-based catalysts was investigated at different Ru loading amount and different support structure. The obtained result indicated that 2 wt% loaded Ru-based catalyst supported on ${\alpha}-Al_2O_3$ showed high activity in low temperature range and suppressed the methanation reaction. The developed prototype fuel processor showed thermal efficiency of 78% as a HHV basis with methane conversion of 92%. CO concentration below 10 ppm in the produced gas is achieved with separate preferential oxidation unit under the condition of $[O_2]/[CO]=2.0$. The partial load operation have been carried out to test the performance of fuel processor from 40% to 80% load, showing stable methane conversion and CO concentration below 10 ppm. The durability test for the daily start-stop and 8 h operation procedure is under investigation and shows no deterioration of its performance after 50 start-stop cycles. In addition to the system design and development.

New Balancing Method of a Flexible Rotor Without Trial Weights (彈性回轉體의 평형잡이에 관한 연구)

  • 양보석;암호탁삼
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제12권3호
    • /
    • pp.409-418
    • /
    • 1988
  • Steam turbines, gas turbines, multistage centrifugal compressors are operated over the range of the first critical speed. In these rotors flexible rotor balancing technique is necessary. In such balancing, influence coefficients are measured by rotating a rotor with trial weight. But for the large rotor, the measurement of influence coefficient takes much time and it reduces the cost efficiency. In this paper the new influence coefficient with rotation of rotor is proposed. First the theoretical background of the method is presented and it is applied to the simple flexible rotor model. Then the experiments are performed and the results of presented method are compared with those of analytical method. By using the obtained influence coefficient, balancing of the flexible rotor is performed.

Effect of Bed Insert Geometry on CO Conversion of WGS Catalyst in a Fluidized Bed Reactor for SEWGS Process (SEWGS 공정을 위한 유동층 반응기에서 내부 삽입물의 모양이 WGS 촉매의 CO 전환율에 미치는 영향)

  • Ryu, Hojung;Kim, Hana;Lee, Dongho;Jin, Gyoungtae;Park, Youngcheol;Jo, Sungho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제24권6호
    • /
    • pp.535-542
    • /
    • 2013
  • To enhance the performance of SEWGS system by holding the WGS catalyst in a SEWGS reactor using bed inserts, effect of bed insert geometry on CO conversion of WGS catalyst was measured and investigated. Small scale fluidized bed reactor was used as experimental apparatus and tablet shaped WGS catalyst and sand particle were used as bed materials. The cylinder type and the spring type bed inserts were used to hold the WGS catalysts. The CO conversion of WGS catalyst with the change of steam/CO ratio was determined based on the exit gas analysis. Moreover, gas flow direction was confirmed by bed pressure drop measurement for each case. The measured CO conversion using the bed inserts showed high value comparable to previous results even though at low catalyst content. Most of input gas flowed through the bed center side when we charged tablet type catalyst into the cylinder type bed insert and this can cause low $CO_2$ capture efficiency because the possibility of contact between input gas and $CO_2$ absorbent is low in this case. However, the spring type bed insert showed good reactivity and good distribution of gas, and therefore, the spring type bed insert was selected as the best bed insert for SEWGS process.