• Title/Summary/Keyword: Steady-State Operation

Search Result 622, Processing Time 0.034 seconds

The KSTAR Vacuum Pumping and Fueling System Upgrade

  • Lim, J.Y.;Chung, K.H.;Cho, S.Y.;Lee, S.K.;Shin, Y.H.;Hong, S.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.39-39
    • /
    • 1999
  • The KSTAR (Korea Superconducting Tokamak Advanced Research) tokamak is a nuclear fusion experimental device for a long pulse/steady-state plasma operation, adopting fully superconducting magnets. In accordance with completion of the basic design of the torus vacuum vessel and the enclosing cryostat, the vacuum pumping and gas fueling basic design has been developed to fulfil the physics requirements. The ultra-high vacuum pumping and sophisticated gas fueling system of the machine is essential to achieve such roles for optimized plasma performance and operation. Recently the vacuum exhaust system using dedicated pumping ports for the vacuum vessel and cryostat has been modified to meet more reliable and successful performance of the KSTAR[Fig. 1].In order to achieve the required base pressure of 5 x 10-9 torr, the total impurity load to the vessel internal is limited to ~5 x 10-5 torr-1/x, while the cryostat base pressure is kept as ~5 x 105 torr to mitigate the thermal load applied to the superconducting magnets. Each KSTAR fueling system will be separately capable of fueling gas at a rate of 50 torr-1/x, consistent with the given pumping throughput. In order to initiate a plasma discharge in KSTAR, the vacuum vessel is filled to a gas pressure of few 10-6 to few 10-4 torr, and additional gas injection is required to maintain and increase the plasma density during the course of the discharge period.

  • PDF

Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation (LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성)

  • Hwang, Lark-Hoon;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.420-428
    • /
    • 2018
  • In this paper, represented uninterruptible power supply (UPS) equipment maintaining constant output voltage, the proposes a photovoltaic system constructed with a step up boosting chopper and single phase pulse width modulation (PWM) voltage source inverter. as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a Photovoltaic that it was so called constant voltage charge. It can be results of saving electric power, and through a normal operation of energy storage system (ESS), the system operated the LED a calling on signal changes at the airport in an efficient manner. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

A Study on the Practical Operation of a Farm-scale Two-phase Anaerobic Digester for the Treatment of Swine Manure (돼지분뇨 처리를 위한 Farm-scale Two-phase Anaerobic Digester의 실증운영에 관한 연구)

  • 백인규;이상락;안정제;권윤정;맹원재
    • Journal of Animal Environmental Science
    • /
    • v.6 no.2
    • /
    • pp.73-81
    • /
    • 2000
  • A two-phase anaerobic digestion system for the treatment of swine waste was constructed in a commercial hog farm. The digester system was composed of 4 major units; slurry storage pit, acidogenic digester, methanogenic digester and sedimentation pit. A biogas boiler unit was also attached to maintain the digester temperature of 37$^{\circ}C$. Substrate lading was made with 2hr-interval by pumping about 2.1$m^3$ of slurry type swine waste from the slurry pit into the acidogenic digester, which corresponds to hydraulic retention time of 4 days for the acidogenic digester and of 11 days for the methanogenic digester. Digester temperature were well maintained as the set temperature of 37$^{\circ}C$ in the methanogenic digester, while the temperature in the acidogenic digester showed around 34$^{\circ}C$. pH also showed a steady-state results of 7.3 in the acidogenic digester and of 7.6 in the methanogenic digester during the operation period. Average biogas production rate was 0.66$m^3$/$m^3$ digester volume. Reduction rate of total solid and volatile solid were 42.8% and 5.8%, respectively. Total nitrogen and ammonia nitrogen were not reduced during the anaerobic fermentation, however, most of VFAs seemed to be converted to the biogas,. These fermentation performance data may suggest that he newly developed a two-phase anaerobic digester for the swine waste treatment worked so successfully.

  • PDF

Performance Analysis with Various Amounts of Electrolyte in a Molten Carbonate Fuel Cell

  • Kim, Yu-Jeong;Kim, Tae-Kyun;Lee, Ki-Jeong;Lee, Choong-Gon
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.234-240
    • /
    • 2016
  • The effect of initial electrolyte loading (IEL) on cell performance in a coin-type molten carbonate fuel cell (MCFC) was investigated in this work. Since the material of MCFC depends on the manufacturer, optimisation requires experimental investigation. In total, four IEL values, 1.5, 2.0, 3.0, and 4.0 g, were used, corresponding to a pore filling ratio (PFR) of 38, 51, 77, and 102%, respectively. The cell performance with respect to the PFR was analysed via steady-state polarisation, step-chronopotentiomtery, and impedance methods. The electrochemical analyses revealed that internal resistance and overpotential of the cell decreased with increasing PFR, and a large overpotential was observed when the PFR was 102%, probably due to the flooding phenomenon. After operation, cross-section of the cell was analysed via surface analysis of SEM and EDS methods, and the remaining electrolyte was estimated by dissolution of the cell in 10 wt% acetic acid. A linear relationship between IEL and the weight reduction ratio by dissolution was obtained. Thus, the remaining amount of electrolyte could be measured after operation. The results of SEM and EDS showed that a PFR of 38 and 102% showed a lack and flooding of electrolytes at the cell, respectively, which led to a large overpotential. This work reports that MCFC performance is allowed only in the narrow range of PFR.

A Design and Test of a Sea Water Source Heat Pump System (해수열원 히트펌프 시스템의 설계 및 운전)

  • Lee, Jae-Hun;Kim, Ji-Young;Baik, Young-Jin;Chang, Ki-Chang;Ra, Ho-Sang;Shin, Kwang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1273-1278
    • /
    • 2008
  • A sea water source cascade heat pump was designed and tested in this study. The system was designed to perform a single stage operation in summer, as well as a cascade operation in winter to ensure the high temperature lift. A steady-state simulation model was developed to analyze and optimize its performance. The simulation results show that the R717 exhibits best performance among combinations considered in this study. A R410A also exhibits the highest performance among HFCs with the smallest compressor displacement. A 15-RT R410A-R134a pilot system was installed in the 5-story commercial building at Samcheok City by the East Sea. A scroll type R410A compressor, a reciprocating type R134a compressor, plate type condenser/ evaporator/ cascade heat exchanger and two electronic expansion valves were used to build a pilot. A titanium plate type heat exchanger is also used for the heat exchanging with a sea water. The heat source/sink water is supplied from the well below the seashore in the depth of 5 m. In the initial test of the system, supply water temperature was rising up to $67^{\circ}C$ using a sea water heat source of $9^{\circ}C$, while an ambient temperature was $4.5^{\circ}C$.

  • PDF

A Fault Diagnosis Technique of an Inverter-fed PMSM under Winding Shorted Turn and Inverter Switch Open Fault (권선 단락 및 스위치 개방 고장 시의 인버터 구동 영구자석 동기전동기의 고장 진단 기법)

  • Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.94-105
    • /
    • 2010
  • To detect faults in an inverter-fed permanent magnet synchronous motor (PMSM) drive under the circumstance having faults in a stator winding and inverter switch, an on-line basis fault detecting scheme during operation is presented. The proposed scheme is achieved by monitoring the second-order harmonic component in q-axis current and the fault is detected by comparing these components with those in normal conditions. The linear interpolation method is employed to determine the harmonic data in normal operating conditions. As soon as the fault is detected, the operating mode is changed to identify a fault type using the phase current waveform. To verify the effectiveness of the proposed fault detecting scheme, a test motor to allow inter-turn short in the stator winding has been built. The entire control algorithm is implemented using DSP TMS320F28335. Without requiring an additional hardware, the fault can be effectively detected by the proposed scheme during operation so long as the steady-state condition is satisfied.

A Fault Detecting Scheme for Short-Circuited Turn in a Permanent Magnet Synchronous Motor through a Current Harmonic Monitoring (전류 고조파 관찰을 통한 영구자석 동기전동기의 권선 단락 고장 진단 기법)

  • Kim, Kyeong-Hwa;Gu, Bon-Gwan;Jung, In-Soung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.167-178
    • /
    • 2010
  • To diagnose a stator winding fault caused by a short-circuited turn in a permanent magnet synchronous motor (PMSM), an on-line based fault detecting scheme during motor operation is presented. The proposed scheme is based on monitoring the second-order harmonic components in q-axis current obtained through the harmonic analysis and a winding fault is detected by comparing these components with those in normal conditions. The linear interpolation method is employed to determine harmonic data in arbitrary normal operating conditions. To verify the effectiveness of the proposed fault detecting scheme, a test motor to allow inter-turn short in the stator winding has been built. The entire control system including harmonic analysis algorithm and fault detecting algorithm is implemented using DSP TMS320F28335. The proposed scheme does not require any additional hardware and can effectively detect a fault during motor operation so long as the steady-state condition is satisfied.

A Numerical Study on Effects of Displacement of a Variable Area Nozzle on Flow and Thrust in a Jet Engine (가변노즐의 변위가 제트 엔진의 유동 및 추력특성에 미치는 영향에 관한 수치해석)

  • Park, Junho;Sohn, Chae Hoon;Park, Dong Chang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.5
    • /
    • pp.1-9
    • /
    • 2013
  • Variable area nozzle, where both throat and exit area vary, is required for optimal expansion and optimal nozzle shape upon operation of after-burner. Steady-state and transient analyses are carried out for each condition with and without afterburner operation and as a function of the location of the nozzle flap. Effects of that nozzle displacement on flow and thrust characteristics are analyzed from numerical results. With variable area nozzle adopted, the combustion field is variable in time, leading to periodically variable thrust. For off-design conditions, flow separation shows up due to over expansion at the flap tips and shock wave does in the nozzle due to under expansion. The undesirable phenomena can be solved by control of variable area nozzle.

A simulation module to practice hydraulic mechanical governors and its adjustment characteristics for stability (유압기계식 거버너의 실습용 시뮬레이션 모듈과 안정도의 조정 특성)

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.533-540
    • /
    • 2013
  • Prime movers in engine rooms inherently are much affected by the adjustment of their governors for the steady state and transient properties, consequently requiring that marine engineers shall be well familiar with the way to manage governor dials for normal operation. The hydro-mechanical governors basically have different control characteristics and adjustment parameters of stability from digital governors. The former include compensation mechanism using dash pot while the control algorithm of the latter is usually based on the PID action. This study is for configuring a simulation module to let trainees practice how to adjust dials for stability on hydraulic governors in the view that the practice by real governors and engines is time consuming and high cost for operation. The governor module includes the adjusting points such as speed set, speed droop, needle valve and compensation pointer with engine module of $2^{nd}$ order coupled. The results of simulation showed satisfactory responses as a training tool for the adjustment of control parameters.

An analysis of a phase- shifted parallel-input/series-output dual converter for high-power step-up applications (대용량 승압형 위상천이 병렬입력/직렬출력 듀얼 컨버터의 분석)

  • 강정일;노정욱;문건우;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.400-409
    • /
    • 2001
  • A new phase-shifted parallel-input/series-output(PISO) dual converter for tush-power step-up applications has been proposed. Since the proposed converter shows a low switch turn-off voltage stress, switching devices with low conduction loss can be employed in order to improve the power conversion efficiency. Moreover, it features a low output capacitor root-mean-square(RMS) current stress, low input current and output voltage ripple contents, and fast control-to-output dynamics compared to its PWM counterpart. In this paper, the operation of the proposed converter is analyzed in detail and its mathematical models and steady-state solutions are presented. A comparative analysis with the conventional PWM PISO dual converter is also provided. To confirm the operation, features, and validity of the Proposed converter, experimental results from an 800W, 24-350Vdc prototype are presented.

  • PDF