• Title/Summary/Keyword: Steady State cycle

Search Result 185, Processing Time 0.025 seconds

Study on the Fuzzy Control of CO2 Heat Pump System (이산화탄소 열펌프 시스템의 퍼지 제어에 관한 연구)

  • Lee, Jae-Seung;Han, Yung-Hee;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.513-518
    • /
    • 2008
  • In the air-conditioning and refrigeration industry, the efforts to protect the environment have been made. One of them is to use carbon dioxide as an alternative refrigerant, however, several researches have shown that the transcritical heat pump system using $CO_2$ has relatively lower efficiency resulting in a degraded steady-state system performance. Capacity control with fuzzy controller was carried out for $CO_2$ heat pump system. Evaporator secondary fluid outlet temperature was suggested for the control variable of compressor speed modulation.

  • PDF

$\mu$-Controller Design for Servo Systems Containing Resonance Effects and Coulomb Frictions (공진 효과 및 쿨롱 마찰이 있는 서보 시스템에 대한 $\mu$-제어기 설계)

  • Hwang, In-Hui;Lim, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.46-48
    • /
    • 1996
  • In almost all the servo systems, especially for the robot manipulators and numerical control systems, there are resonance effects and nonlinear frictions which should be considered in designing servo controllers. In this paper to compensate friction and track the step-input without steady-state error, the original system is augmented with an integrator and employes $\mu$-Controller design method $\mu$-Controller design method enables to meet not only performance requirements but robust stabilities simultaneously. And there may exist a limit cycles due to interaction between integrator and nonlinear friction. With describing function method, the possibility of limit cycle is checked.

  • PDF

Parameter Estimation of Y-$\Delta$ Transformer Using the Least Square Method (최소자승법을 이용한 Y-$\Delta$ 변압기 파라미터 추정 방법)

  • Kang, Yong-Cheol;Hwang, Tae-Keun;Lee, Byung-Eun;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.42-43
    • /
    • 2007
  • This paper proposes a parameter estimation technique of a power transformer. Based on the combined equation, it estimates separately the primary and secondary leakage inductances, winding resistances using the least square method from the instantaneous voltages and currents in the steady state. The performance of the proposed technique was investigated by varying the cut-off frequency of the filter and the number of samples per cycle. The technique estimates the parameters with higher sampling frequencies.

  • PDF

Practical Photovoltaic Simulator with a Cross Tackling Control Strategy Based on the First-hand Duty Cycle Processing

  • Wang, Shuren;Jiang, Wei;Lin, Zhengyu
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1018-1025
    • /
    • 2015
  • This paper proposes a methodological scheme for the photovoltaic (PV) simulator design. With the advantages of a digital controller system, linear interpolation is proposed for precise fitting with higher computational efficiency. A novel control strategy that directly tackles two different duty cycles is proposed and implemented to achieve a full-range operation including short circuit (SC) and open circuit (OC) conditions. Systematic design procedures for both hardware and algorithm are explained, and a prototype is built. Experimental results confirm an accurate steady state performance under different load conditions, including SC and OC. This low power apparatus can be adopted for PV education and research with a limited budget.

Performance Analysis of R-1270(Propylene) Refrigeration System Using Internal Heat Exchanger (내부 열교환기를 이용한 R-1270용 냉동시스템의 성능 분석)

  • Ku, Hak-Keun
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.36-42
    • /
    • 2014
  • This paper considers the influence of internal heat exchangers on the efficiency of a refrigerating system using R-1270. These internal heat exchangers(liquid-gas or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed. The main results were summarized as follows : the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, and effectiveness have the influences on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. With a thorough grasp of it is possible to design the R-1270 compression refrigeration cycle using internal heat exchanger.

Modeling and Dynamic Analysis of a Front Loaded Washing Machine with Ball Type Automatic Balancer (볼 자동균형장치를 채용한 드럼세탁기의 모델링 및 동적 거동 해석)

  • 이준영;조성오;김태식;박윤서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.119-131
    • /
    • 1997
  • Ball type automatic balancer is used to reduce the vibration caused by unbalance of rotor. In this study, A analytic modeling of a front loaded washing machine with ball type automatic balancer has been suggested theoretically and ADAMS has been used to analyze the dynamic characteristics of automatic balancer. It is found from simulation and experimental results that the automatic balancer suppress the steady state vibration of the washing machine effectively. The test results match well with the simulation results of ADAMS, thereby the dynamic model of ADAMS can be used as virtual prototype to predict the vibration characteristics which could be changed by the modification of design variable and can reduce the design cycle sharply. To maximize the balancing effect of automatic balancer, the friction between balls and race and the deviation between geometric center and rotation center of drum need to be minimized and the optimum design for the stiffness of flange shaft and the angular acceleration of drum should be achieved.

  • PDF

Regulated Incremental Conductance (r-INC) MPPT Algorithm for Photovoltaic Systems

  • Wellawatta, Thusitha Randima;Choi, Sung-Jin
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1544-1553
    • /
    • 2019
  • The efficiency of photovoltaic generation systems depends on the maximum power point tracking (MPPT) technique. Among the various schemes presented in the literature, the incremental conductance (INC) method is one of the most frequently used due to its superb tracking ability under changes in insolation and temperature. Generally, conventional INC algorithms implement a simple duty-cycle updating rule that is mainly found on the polarity of the peak-power evaluation function. However, this fails to maximize the performance in both steady-state and transient conditions. In order to overcome this limitation, a novel regulated INC (r-INC) method is proposed in this paper. Like the compensators in automatic control systems, this method applies a digital compensator to evaluate the INC function and improve the capability of power tracking. Precise modeling of a new MPPT system is also presented in the optimized design process. A 120W boost peak power tracker is utilized to obtain comparative test results and to confirm the superiority of the proposed method over existing techniques.

The Energy Flow and Mineral Cycles in a Zoysia japonica and a Miscanthus sinensis Ecosystem on Mt. Kwanak 10. The Cycles of Cu (관악산의 잔디와 억새 생태계에 있어서 에너지 흐름과 무기물의 순환 10.구리의 순환)

  • 심규철;여성희;장남기
    • Asian Journal of Turfgrass Science
    • /
    • v.11 no.4
    • /
    • pp.295-301
    • /
    • 1997
  • The cycle of heavy metal, copper, was investigated in dynamic grassland ecosystems at a steady state in a Zoysia japonica and a Miscanthus sinensis ecosystem in Mt Kwanak, Korea. Total average storage amounts in Z. japonica and M sinensis grasslands were copper 23.92mg /$m^2$ and 51.82mg /$m^2$ respectively. Estimates of decay constants for based on experimental and mathematical model, were 0.18 in Z. japonica grassland, and 0.30 in M sinensis grassland. Decay half time of copper were 3.85 years in Z. japonica grassland and 2.31 years in A'. sinensis grassland. 95% decay times of initial copper amounts in Z. japonica and A'. sinensis were 16.68 and 9.99 years. Needed times to decay almost all of elements in Z. japonica and M sinensis grassland were 27.80 years and 16.65 years respectively. The copper was losed more rapidly in M. sinensis than in Z. japonica grassland.

  • PDF

Development of Simulation Program for Multi-Air conditioner (멀티에어컨의 성능해석 프로그램 개발)

  • Jeong, B.Y.;Koh, J.Y.;Park, B.D.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.63-72
    • /
    • 2000
  • In this study, theoretical simulation method for the steady state characteristics of a refrigeration cycle which consists of one condenser and multi-evaporator (Multi-air conditioner) is presented. The simulation was performed for a typical multi-air conditioning system consisted one outdoor unit with air-cooled condenser, compressor, linear electric expansion valve and bypass circuit and connected three-evaporators (three indoor units). The simulation results are good agreement with those of experiments within 5 $\sim$ 10% at the given system operation conditions which are condensing pressure, evaporating pressure, sub-cooled degree of condenser, superheated degree, discharge temperature of compressor and pulse of linear electric expansion valve.

  • PDF

Analysis of Fuelling Sequence and Fatigue Life for 4-Bundle Shift Refuelling Scheme in CANDU6 NPP

  • Namgung, Ihn
    • Nuclear Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.176-185
    • /
    • 2002
  • A 4-bundle shift refuelling method of CANDU6 F/H (Fuel Handling) System is analyzed to assess the operational flexibility and capacity of F/H system. The current 8-bundle shift refuelling scheme requires to refuel eight fuel bundles from a single fuel channel, and to refuel 14 fuel channels in a week on average assuming that the reactor is in a steady state. The analysis showed that the 4-bundle shift refuelling method increases F/M (Fuelling Machine) duty cycle and operator load. However, the fuellin’g method change from the 8- to 4-bundle shift refuelling ill not require additional team of operators. A marginal increase in the maintenance cost may be resulted in by the change of fuelling method and the increase of fatigue usage factors requires some components to be replaced during the FM lifetime.