• Title/Summary/Keyword: Steady State Performance

Search Result 1,426, Processing Time 0.033 seconds

Modified Direct Torque Control using Algorithm Control of Stator Flux Estimation and Space Vector Modulation Based on Fuzzy Logic Control for Achieving High Performance from Induction Motors

  • Rashag, Hassan Farhan;Koh, S.P.;Abdalla, Ahmed N.;Tan, Nadia M.L.;Chong, K.H.
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.369-380
    • /
    • 2013
  • Direct torque control based on space vector modulation (SVM-DTC) protects the DTC transient merits. Furthermore, it creates better quality steady-state performance in a wide speed range. The modified method of DTC using SVM improves the electrical magnitudes of asynchronous machines, such as minimizing the stator current distortions, the stator flux with electromagnetic torque without ripple, the fast response of the rotor speed, and the constant switching frequency. In this paper, the proposed method is based on two new control strategies for direct torque control with space vector modulation. First, fuzzy logic control is used instead of the PI torque and a PI flux controller to minimizing the torque error and to achieve a constant switching frequency. The voltages in the direct and quadratic reference frame ($V_d$, $V_q$) are achieved by fuzzy logic control. In this scheme, the switching capability of the inverter is fully utilized, which improves the system performance. Second, the close loop of stator flux estimation based on the voltage model and a low pass filter is used to counteract the drawbacks in the open loop of the stator flux such as the problems saturation and dc drift. The response of this new control strategy is compared with DTC-SVM. The experimental and simulation results demonstrate that the proposed control topology outperforms the conventional DTC-SVM in terms of system robustness and eliminating the bad outcome of dc-offset.

Process Parameter Selection for Plasma Electrolytic Oxidation to Improve Heat Dissipation Performance of Aluminum Alloy Heat Sink for Shipboard LED Luminaries (선박용 LED 등기구의 알루미늄 합금 방열판의 방열성능 향상을 위한 플라즈마 전해 산화의 공정변수 선정에 관한 연구)

  • Lee, Jung-Hyung;Jeong, In-Kyo;Han, Min-Su
    • Journal of Surface Science and Engineering
    • /
    • v.51 no.6
    • /
    • pp.415-420
    • /
    • 2018
  • The possibility of an improvement in heat dissipation performance of aluminum alloy heat sink for shipboard LED luminaries through plasma electrolytic oxidation (PEO) was investigated. Four different PEO coatings were produced on aluminum alloy 5052 in silicate based alkaline solution by varying current density ($50{\sim}200mA/cm^2$). On voltage-time response curves, three stages were clearly distinguished at all current densities, namely an initial linear increase, slowdown of increase rate, and steady state(constant voltage). It was found that the increase in current density caused the breakdown voltage to increase. Two different surface morphologies - coralline porous structure and pancake structure - were confirmed by SEM examination. The coralline porous structure was predominant in the coatings produced at lower current densities (50 and $100mA/cm^2$) while under high current densities(150 and $200mA/cm^2$) the pancake structure became dominant. The coating thickness was measured and found to be in a range between about $13{\mu}m$ and $44{\mu}m$, showing increasing thickness with increasing current density. As a result, $100mA/cm^2$ was proposed as an effective process parameter to improve the heat dissipation performance of aluminum alloy heat sink, which could lower the LED operating temperature by about 30%.

Modeling and Simulation of a Gas Turbine Engine for Control of Mechanical Propulsion Systems (기계식 추진 시스템 제어를 위한 가스터빈 엔진 모델링 및 시뮬레이션)

  • Back, Kyeongmi;Huh, Hwanil;Ki, Jayoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.4
    • /
    • pp.43-52
    • /
    • 2021
  • In this study, performance modeling and simulation of a gas turbine engine, a constituent module, was performed for the integrated control of the CODOG structure, mechanical propulsion systems. The engine model used MATLAB/Simulink to facilitate integration with the host controller and other components, and was configured to enable input/output settings suitable for the system configuration and purpose. In general, engine manufacturers do not provide performance data for the engine and components. Therefore, as a modeling method for a gas turbine, a CMF method that obtains performance data by scaling the map of components was applied. Using the generated model and simulation program, steady-state and dynamic simulation analysis tests were performed, and reliability within 5% of the maximum error was secured for the final output of power.

Motor Speed Control Using the Fractional Order Integral (유리차수 적분을 이용한 전동기 속도제어)

  • Jeon, Yong-Ho;Kang, Jung-Yoog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.503-510
    • /
    • 2021
  • This study intends to apply the mathematical method of fractional order differentiation to a controller that controls the response of the system. Therefore, we design integrator for the fractional index by converting it into discrete time to construct a controller. The IP controller composes an integral controller for errors and the proportional controller applies only the system output. The controller is designed by using the fractional order integrator to the integral controller of the IP controller. First, the performance of the PI controller and the IP controller is compared, and the designed controller is applied to the speed control of the motor. As a result, the motor output speed was uniformed and precise control performance could be obtained. It was confirmed that the speed error in the steady state is within 0.1 [%], and it has precise and uniform speed control performance without overshoot.

Individual Variable Step-Size Subband Affine Projection Algorithm (독립 가변 스텝사이즈 부밴드 인접투사 알고리즘)

  • Choi, Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.3
    • /
    • pp.443-448
    • /
    • 2022
  • This paper presents a subband affine projection algorithm with variable step size to improve convergence performance in adaptive filtering applications with long adaptive filters and highly correlated input signals. The proposed algorithm can obtain fast convergence speed and small steady-state error by using different step sizes for each adaptive sub-filter in the subband structure to which polyphase decomposition and noble identity are applied. The step size derived to minimize the mean square error of the adaptive filter at each update time shows better convergence performance than the existing algorithm using a variable step size. In order to confirm the convergence performance of the proposed algorithm, which is superior to the existing algorithm, computer simulations are performed for mean square deviation(MSD) for AR(1) and AR(2) colored input signals considering the system identification model.

Experimental Feasibility Study on Low-Temperature Differential Stirling Engines with Water Spray Heat Transfer (스프레이 열전달을 이용한 저온도차 스털링 엔진의 실험적 개념 연구)

  • Jang, Seon-Jun;Lee, Yoon-Pyo;Sim, Kyuho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.475-482
    • /
    • 2014
  • This paper presents the results of an experimental feasibility study on low-temperature differential Stirling engines with water spray heat transfer. The water spray enhances the efficiency of the heat transfer from heat sources to the engine and reduces the performance degeneration due to the dead volumes of conventional heat exchangers. A test Stirling engine was developed and an experiment was conducted to determine the characteristics for the initial start-up, steady-state operation, and power output for various flow rates and temperatures of hot supply water. The test results showed that larger flow rates led to reductions in the minimum working temperature of the hot water at start-up. During a series of steady-state operations, higher flow rates and temperatures increased the working speed. Furthermore, the work per cycle and power output were also increased. Eventually, the test Stirling engine had a power level of 0.05 W. Based on this, further research will be conducted to obtain a higher power output and investigate various applications.

Toxicokinetics of rifapentine in beagle dogs (Beagle dog에 있어서 rifapentine의 독성동태연구)

  • Shin, Ho-chul;Lee, Hye-suk;Cha, Shin-woo;Han, Sang-seop;Roh, Jung-ku;Kim, Jin-suk;Lee, Won-chang
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.4
    • /
    • pp.815-822
    • /
    • 1995
  • The toxicokinetics of rifapentine was studied after an oral administration to beagle dogs. High-performance liquid chromatography(HPLC) using column-switching technique was performed to determine the serum concentrations of rifapentine. The pharmacokinetic profiles of rifapentine were analysed using one-compartment open model. Following a single oral administration of 10mg/kg, pharmacokinetic parameters were determined as follows: maximum serum concentration($C_{max}$), $28.90{\mu}g/ml$; maximum concentration time($T_{max}$), 3.7hr; elimination half-life($t_{1/2}$, 4.7hr; area under the curve(AUC), $339.0{\mu}g{\cdot}hr/ml$; volume of disiribution/bioavailability (Vd/F), 0.21 l/kg; lag time, 24min; absorption rate constant($k_a$), $0.445hr^{-1}$; elimination rate constant($k_{el}$), $0.148hr^{-1}$. After 6 month multiple oral doses of 10mg/kg/day, parameters were as follows: $C_{max}$, $34.40{\mu}g/ml$; $T_{max}$, 2.6hr; $t_{1/2}$, 6.7hr; AUC, $391.3{\mu}g{\cdot}hr/ml$; Vd/F, 0.291/kg; $k_a$, $0.976hr^{-1}$; $k_{el}$, $0.104hr^{-1}$. The consistant kinetic parameters after a single and multiple oral administration show that there was no accumulation of rifapentine after 6 month oral administration. We also simulated the concentration of rifapentine after oral multiple administration of 10 and 50mg/kg/ day, based on the parameters obtained form the single administration. The measured serum concentrations of rifapentine were well fitted to the simulated results. The simulated results show that rifapentine readily reaches to steady-state after about 3 doses and the steady-state serum concentrations($C_{ss}$) are fluctuated in between $2.2{\sim}25.2{\mu}g/ml$, and $10.6{\sim}125.2{\mu}g/ml$ at the doses of 10 and 50mg/kg/day, respectively.

  • PDF

Frequency Recognition in SSVEP-based BCI systems With a Combination of CCA and PSDA (CCA와 PSDA를 결합한 SSVEP 기반 BCI 시스템의 주파수 인식 기법)

  • Lee, Ju-Yeong;Lee, Yu-Ri;Kim, Hyoung-Nam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.10
    • /
    • pp.139-147
    • /
    • 2015
  • Steady state visual evoked potential (SSVEP) has been actively studied because of its short training time, relatively higher signal-to-noise ratio, and higher information transfer rate. There are two popular analysis methods for SSVEP signals: power spectral density analysis (PSDA) and canonical correlation analysis (CCA). However, the PSDA is known to be vulnerable to noise due to the use of a single channel. Although conventional CCA is more accurate than PSDA, it may not be appropriate for the real-time SSVEP-based BCI system when it has short time window length because it uses sinusoidal signals as references. Therefore, the two methods are not efficient for the real-time BCI system that requires a short TW and a high recognition accuracy. To overcome this limitation of the conventional methods, this paper proposes a frequency recognition method with a combination of CCA and PSDA using the difference between powers of canonical variables obtained from the results of CCA. Experimental results show that the performance of the combination of CCA and PSDA is better than that of CCA for the case of a short TW.

Feasibility Studies on Anaerobic Sequencing Batch Reactor for Sludge Treatment

  • Chang Duk;Hur Joon-Moo;Son Bu-Soon;Park Jong-An;Jang Bong-Ki
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.1 no.2
    • /
    • pp.125-136
    • /
    • 1997
  • Digestion of a municipal wastewater sludge by the anaerobic sequencing batch reactor(ASBR) was investigated to evaluate the performance of the ASBR process at a critical condition of high-solids-content feed. The reactors were operated at an HRT of 10 days with an equivalent loading rate of 0.8-1.5 gVS/L/d at $35^{\circ}C.$ The main conclusions drawn from this study were as follows: 1. Digestion of a municipal wastewater sludge was possible using the ASBR in spite of high concentration of settleable solids in the sludge. The ASBRS with 3- and 4-day cycle period showed almost identical high digestion performances. 2. No adverse effect on digestion stability was observed in the ASBRS in spite of withdrawal and replenishment of $30\%\;or\;40\%$ of liquid contents. A conventional anaerobic digester could be easily converted to the ASBR without any stability problem. 3. Flotation thickening occurred in thicken step of the ASBRS throughout steady state, and floating bed volume at the end of thicken period occupied about $70\%$ of the working volume of the reactor. Efficiency of flotation thickening in the ASBRS could be comparable to that of additional gravity thickening of a completely mixed digester. 4. Solids were accumulated rapidly in the ASBR during start-up period. Solids concentrations in the ASBRS were 2.6 times higher than that in the completely mixed control reactor at steady state. Dehydrogenase activity had a strong correlation with the solids concentration. Dehydrogenase activity of the digested sludge in the ASBR was 2.9 times higher than that of the sludge in the control reactor, and about 25 times higher than that of the subnatant in the ASBR. 5. Remarkable increase in equivalent gas production of $52\%$ was observed at the ASBRS compared with the control reactor in spite of similar Quality of clarified effluent from the ASBRS and control reactor. The increase in gas production from the ASBRS was believed to be combined results of accumulation of microorganisms, higher driving force applied, and additional long-term degradation of organics continuously accumulated.

  • PDF

A study on grid aspect ratio of fire dynamics simulator (FDS의 격자 종횡비에 관한 연구)

  • Kim, Won Ouk;Park, Woe-Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.923-928
    • /
    • 2015
  • The FDS is one of the most used programs for fire analysis and needs an optimal grid selection for an accurate analysis. This study selected various grid aspect ratios (ARs) for selection of optimal grid and analyzed them with FDS v 6.1.2. A calculation time of 10 min. was used, which is enough to obtain the time average value of temperature changes. Temperature, visibility, and the time average value of mass balance are obtained from 200-600 s, which is a period of maintaining quasi-steady state. Two polyurethane fires of 1 [MW] and 2 [MW] in two enclosures of $10{\times}10{\times}3[m^3]$ and $20{\times}20{\times}3[m^3]$ were considered. Time variations of heat release rates, temperature, visibility, and mass balance were compared for ARs from 1-6. The heat release rates were accurate for all aspect ratios regardless of fire and enclosure sizes. The quasi-steady state temperature and visibility were well predicted for $AR{\leq}5$. Temperature drop and skewness of mass conservation, however, increased with increasing aspect ratio. Therefore, careful investigation of the grid size is recommended in performance-based design when $AR{\geq}3$, where temperature and visibility in early stage of a fire are important parameters. For accurate simulations of enclosure fires, grid sizes of 0.1~0.2 [m] and smaller in the vertical direction and $AR{\leq}2$ are recommended.