• 제목/요약/키워드: Stator flux control

검색결과 350건 처리시간 0.024초

속도 연산기를 이용한 유도전동기의 속도제어 (Control of Induction Motor with Speed Estimator)

  • 서영수;차광훈;이상훈;임영배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2129-2131
    • /
    • 1997
  • A sensorless controller of induction motor has several advantage: availability in a harsh environment. In this paper, the speed information is driving from the currents and the estimated stator flux. To obtain the estimated stator flux, this study is using The Estimator. The simulation results show that the proposed scheme has activity over a wide speed range and good response to load variations

  • PDF

유도전동기의 센서리스 속도제어 (Sensorless Speed Control of Induction Motor)

  • 서영수;차광훈;이상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.509-511
    • /
    • 1997
  • A sensorless controller of induction motor has several advantage availability in a harsh environment. In this paper, the speed information is driving from the currents and the estimated stator flux. To obtain the estimated stator flux, this study is using the Estimator. The simulation results show that the proposed scheme has activity over a wide speed range and good response to load variations.

  • PDF

자속추정기에 의한 유도전동기 센서리스 속도제어 (SENSORLESS SPEED CONTROL OF INDUCTION MOTOR WITH SPEED ESTIMATOR)

  • 김성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.432-439
    • /
    • 1999
  • Several methods of induction motor drives which used speed estimators instead of shaft encoders have been reported. However those speed sensorless systems with estimators employing stator voltates and currents usually deteriorates as the speed gets lower because it is difficult to calculate the accurate rotor flux under the influence of DC-offset and saturation of integrators. In this paper to calculate rotor flux at low speed the new rotor flux estimator which replaces integra-tors with two lag circuits is proposed. Simulation and experiment results confirm the validity of this control scheme.

  • PDF

직접 토크제어에 의한 유도전동기의 위치제어 시스템 (An Induction Motor Motion Control System with Direct Torque Control)

  • 김남훈;김민호;김동희;김민회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1036-1038
    • /
    • 2000
  • This paper presents an implementation of digital motion control system of induction motor vector drives with a direct torque control(DTC) using the 16bit DSP TMS 320F240. The DSP controller enable enhanced real time algorithm and cost-effective design of intelligent controllers for induction motors which can be yield enhanced operation, fewer system components, lower system cost, increased efficiency and high performance. The system presented are stator flux observer of current model that inputs are current sensing of motor terminal and rotor angle, and optimal switching look-up table by using fully integrated control software. The developed system are shown a good motion control response characteristic results and high performance features using 2.2Kw general purposed induction motor.

  • PDF

유도전동기 드라이브 시스템에서 센서 고장효과 분석 (Analysis of Sensor Fault Effect in Induction Motor Drives)

  • 류지수;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2011-2013
    • /
    • 2003
  • The effects of sensor faults on motor variables and control performance in induction motor drives are analyzed by both theoretical approach and simulation study, Vector control and direct torque control method for induction motor are well known. To control speed or position, the informations on rotor speed and rotor or stator flux are required in these control algorithms. The speed is measured by encoder. and the rotor or stator flux is estimated using motor parameters and measured currents. The control input generated based on the information from a faulted sensor should be far from the desired value and deteriorates the overall control performance.

  • PDF

자속추정기를 이용한 유도전동기 센서리스 벡터제어 (Sensorless Vector Control of Induction Motor Using the Flux Estimator)

  • 김경서;조병국
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권2호
    • /
    • pp.87-92
    • /
    • 2003
  • This paper presents a flux estimator for the sensorless vector control of induction motors. The proposed method utilize the combination of the voltage model based on stator equivalent model and the current model based on rotor equivalent model, which enables stable estimation of rotor flux in high speed region and in low speed region. The dynamic performance of proposed method is verified through the experiment. The experimental results show that motors ran easily start even under 150[%] load condition and operate continuously below 0.5[Hz].

폐루프 자속추정기를 이용한 유도전동기의 센서리스 벡터제어 (Sensorless Vector Control of Induction Motor Using Closed loop Flux Estimator)

  • 서영수;임영배;음두성;이상훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.217-220
    • /
    • 1998
  • In this paper, for high performance as drive, in the speed sensorless vector control of induction motor, introduced flux estimator of voltage model and error compensation algorithm using closed loop integration method, and then we proposed a improved flux estimation method of high accuracy. And the rotor speed is estimating using the stator current and the estimated flux, it is used speed information. The proposed scheme is verified through digital simulations and experiments for 3.7[kW] induction motor and shows good dynamic performance.

  • PDF

Model Following Sliding-Mode Control of a Six-Phase Induction Motor Drive

  • Abjadi, Navid R.;Markadeh, Gholamreza Arab;Soltan, Jafar
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.694-701
    • /
    • 2010
  • In this paper an effective direct torque control (DTC) and stator flux control is developed for a quasi six-phase induction motor (QIM) drive with sinusoidally distributed windings. Combining sliding-mode (SM) control and adaptive input-output feedback linearization, a nonlinear controller is designed in the stationary reference frame, which is capable of tracking control of the stator flux and torque independently. The motor controllers are designed in order to track a desired second order linear reference model in spite of motor resistances mismatching. The effectiveness and capability of the proposed method is shown by practical results obtained for a QIM supplied from a voltage source inverter (VSI).

전류형 인버어터로 작동되는 유도전동기의 자동제어에 의한 효율게선에 관한 연구 (Improvement in Efficiency of CSI fed Induction Motor by Means of Flux Control)

  • 박민호;김흥근
    • 대한전기학회논문지
    • /
    • 제31권8호
    • /
    • pp.46-53
    • /
    • 1982
  • When an induction motor is lightly loaded, the efficiency can be very substantially improved by controlling the air gap flux. Thus in the system which requires constant speed under either normal load or light load, it is possible to save energy by means of controlling the air gap flux. In this paper, the required relationships between stator current and rotor slip frequency for optimal efficiency control is derived and the improved control loop is suggested.

  • PDF

전영역에서 안정된 유도전동기의 센서리스 속도제어 (A Stable Sensorless Speed Control for Induction Motor in the Overall Range)

  • 김종수;김성환;오세진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.641-647
    • /
    • 2004
  • By most sensorless speed control schemes for induction motor. the control performances in high speed range are good, but it is difficult to obtain satisfactory results in low speed region. This paper proposes a new method controlling the low and the high speed regions separately to attain the stable operation in the overall range. The current error compensation method, in which the controlled stator voltage is applied to the induction motor so that the error between stator currents of the numerical model and the actual motor can be forced to decay to zero as time proceeds. is used in the low speed region In the high speed region. the method with adaptive observer is utilized. This control strategy contains an adaptive state observer for flux estimation. The rotor speed can be calculated from the rotor flux and the motor currents. The experimental results indicate good speed and load responses from the very low speed range to the high, and also show accurate speed changing performance between the low and the high speed range.