• Title/Summary/Keyword: Stator bar

Search Result 76, Processing Time 0.035 seconds

3D FE Analysis of Hall Effect Torque Sensor and Shape Design of Its Stator teeth (홀소자 토크센서의 3차원 유한요소해석 및 고정자 치 형상설계)

  • Lee, Bo-Ram;Kim, Young-Sun;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.702_703
    • /
    • 2009
  • Electric Power Steering(EPS) system is superior to conventional Hydraulic Power Steering(HPS) system in aspect of fuel economy and environmental concerns. The EPS system consists of torque sensor, electric motor, ECU(Electric Control Unit), gears and etc. Among the elements, the torque sensor is one of the core technologies of which output signal is used for main input of EPS controller. Usually, the torque sensor has used torsion bar to transform torsion angle into torque. The torsion angle of both ends of a torsion bar is measured by a contact variable resistor. In this paper, the sensor is accurately analyzed using 3D finite element method and its characteristics with respect to four different shapes of the stator teeth are compared. The four shapes are rectangular, triangular, trapezoidal and circular type.

  • PDF

Comparisons of Linear Characteristic for Shape of Stator Teeth of Hall Effect Torque Sensor

  • Lee, Boram;Kim, Young Sun;Park, Il Han
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.285-290
    • /
    • 2012
  • Electric Power Steering (EPS) system is superior to conventional Hydraulic Power Steering (HPS) system in aspect of fuel economy and environmental concerns. The EPS system consists of torque sensor, electric motor, ECU (Electric Control Unit), gears and etc. Among the elements, the torque sensor is one of the core technologies of which output signal is used for main input of EPS controller. Usually, the torque sensor has used torsion bar to transform torsion angle into torque and needs linear characteristic in terms of flux variation with respect to rotation angle of permanent magnet. The torsion angle of both ends of a torsion bar is measured by a contact variable resistor. In this paper, the sensor is accurately analyzed using 3D finite element method and its characteristics with respect to four different shapes of the stator teeth are compared. The four shapes are rectangular, triangular, trapezoidal and circular type.

Study on the Post-Assembly Magnetization Method of Permanent Magnet Motor (영구자석형 전동기의 조립 후 착자 방법에 대한 연구)

  • Lee, C.K.;Kwon, B.I.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.104-106
    • /
    • 2003
  • In this paper, we study about the stator winding magnetization method and the magnetizing fixture magnetization method in post-assembly magnetization. Most of small electrical machine use the stator winding magnetization method but it is impossible to magnetize the permanent magnet by the stator winding magnetization method when the capacity of machine increases and the coercive force of magnet increases. And the eddy current disturbs the magnetization seriously in case of LSPM(Line Start Permanent magnet Motor) that have conductor bar in rotor. Hence, the magnetization fixture is required. So, in this paper we study about the post-assembly magnetization method that can use the stator winding magnetization method or must use the magnetization fixture magnetization method.

  • PDF

Efficient Rotor Fault Detection of Induction Motors Using Stator Current Spectrum Monitoring (고정자 전류 스펙트럼 모니터링을 이용한 효과적인 유도전동기 회전자 고장 걸출)

  • 정춘호;우혁재;송명현;강의성;김경민
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.6
    • /
    • pp.873-878
    • /
    • 2002
  • Stator current spectrum by the fast Fourier transform (FFT) of current signals has been widely used for fault detection in induction motors. In this paper, we propose efficient rotor fault detection of Induction motors using stator current spectrum monitoring. The proposed method utilizes the mean absolute difference (MAD) between a Predetermined reference vector and a feature vector extracted from the stator current spectrum. Our proposed approach requires a smaller amount of computations when compared to fault detection algorithms based on neural networks, since it uses simple MAD criterion to detect rotor faults related broken rotor bars. Experimental results show that our proposed method can successively detect the rotor fault of the induction motor.

Analysis of the Torque Characteristics and Loss Distribution of the Rotor Bar of an Inverter-fed Cage Induction Motor with Skewed Slots (사구슬롯이 있는 3상 농형 유도 전동기의 인버터 구동시 토오크 특성 및 회전자 바 동손분포 해석)

  • Kim, Byeong-Taek;Choe, Byeong-Il;Park, Seung-Chan;O, Gyeong-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.12
    • /
    • pp.797-806
    • /
    • 2000
  • In this paper, the torque characteristics and the bar loss distribution are analyzed when a general cage induction motor with skewed slots is fed by a 6-step inverter. For the electromagnetic analysis, time-stepping finite element method is used. And the multi-slice technique and sliding surface technique are respectively utilized to consider the skew effect and the rotation of the rotor. As a result, the effects of skewed rotor bar and the inverter output voltage on the characteristics of the torque and bar loss in the rotor are investigated. The simulation results are verified by measurement of flux density distribution axially in the stator teeth.

  • PDF

Electrical Degradation of Stator Bars for Large Turbine Generator after 1000 Thermal Cycles (대형 터빈 발전기용 고정자 권선의 1000 thermal cycle 후 전기적 특성 변화)

  • Kang, Myung-Guk;Kim, Tae-Hee;Lee, Jai-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.975-976
    • /
    • 2007
  • Thermal and mechanical stresses, caused by repetitive start and stop and load fluctuation during long time operation, on winding stator bars are one of the main causes for electrical degradation of insulating materials. To understand the degradation process, we manufactured bar specimens with the same processes that make generator winding stator bars and the specimens were subjected to various degrees of thermal cycling. Measurements of the insulation properties, such as dissipation factor, tip-up and partial discharge, for un-aged specimens and for specimens aged by thermal cycling at 50, 100, 250, 500 and 1000 thermal cycles were performed. Finally all specimens were tested to obtain electrical breakdown voltages. In this paper we present the data and electrical degradation analysis results obtained during this program.

  • PDF

Detecting Method for Broken Rotor Bar of Induction Motor by Measuring Air-gap Flux (공극자속 측정에 의한 유도전동기 회전자의 Broken Bar 검출기법)

  • Hwang, Don-Ha;Kang, Dong-Sik;Lee, Jin-Hee;Choi, Kyeong-Ho;Kim, Dong-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.475-480
    • /
    • 2006
  • In this paper, a new approach for detecting broken rotor bars in a squirrel-cage induction motor is proposed. The air-gap flux variation analysis was done using search coils inserted in stator slots when broken rotor bar occurs. An accurate modeling and analysis of air-gap flux variation in the induction motor are developed using finite-element (FE) software packages, and measurement of the flux are made using search coils. The simulation was done for the induction motor with 380 [V], 5 [HP], 4 Poles, 1,742 [rpm] ratings using the commercial FE analysis tool. The simulation and experiment results can be useful for detecting the broken rotor bar of an induction motor.

  • PDF

The Development of Portable Rotor Bar Fault Diagnosis System for Three Phase Small Induction Motors Using LabVIEW (LaVIEW를 이용한 휴대용 3상 소형유도전동기 회전자 바 고장 진단 시스템 개발)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Lee, Tae-Hun;Woo, Hyeok-Jae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.51-55
    • /
    • 2007
  • In this paper, a portable rotor bar fault diagnosis system for small 3 phase induction motors is suggested. For portable real-tine diagnosis system, an USB-DAQ board for collecting the 3 phase current data, three current probes, and a notebook computer are used. The LabVIEW graphical language is used for filtering, analysis, storing, and monitoring the current data. The three phase stator current are filtered and transformed to frequency level by FIT. An analysis window programed by LabVIEW is located in front panel to show the FIT results and this suggested window has a zooming function to detect the fault feature more easily near the feature frequency range which is varying by the slip frequency. To show the possibility of portable rotor bar diagnosis system, three types(healthy, one rotor bar fault, two rotor bar fault) of rotor bar are intentionally prepared and compared by the suggested window of front panel. Experimental results are shown that a suggested diagnosis system is applicable to portable diagnosis system and the rotor bar fault is detected by the frequency window in front panel programed in LabVIEW graphical language.

Analysis of On-Line Partial Discharge in Air-Coolded Gas Turbine Generator (공랭식 가스터빈 발전기의 운전중 부분방전 분석)

  • Lee, Eun-Chun;Kong, Tae-Sik;Kim, Jae-Chul;Kim, Hee-Dong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.41-47
    • /
    • 2014
  • The on-line partial discharge (PD) in stator windings of air-cooled gas turbine (GT) generator (119.2MVA, 13.8kV) is measured and analyzed in this paper. This generator was designed by global vacuum pressure impregnation (VPI). The generator failed two times at top bar (16T) of phase B in the stator slot. Six epoxy-mica capacitors were installed in three phases of GT generator. On-line PD test was performed on GT generator using turbine generator analyzer (TGA). TGA showed that the normalized quantity number (NQN) and the PD magnitude($Q_m$) were high in phase B. Internal discharges were generated in phases A, B and C. The trend analysis of NQN and $Q_m$ value are obtained in order to monitor the insulation condition in GT generator stator windings. Phases A and C were in good condition. But phase B had deteriorated significantly

Detecting Method for Broken Rotor Bar of Induction Motors by Flux Measurement (자속 측정을 통한 유도전동기의 회전자 바 손상 검출기법)

  • Hwang, Don-Ha;Han, Sang-Bo;Kang, Dong-Sik;Kim, Byong-Kuk;Kim, Mi-Jung;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.827-828
    • /
    • 2006
  • This paper proposes a new method for detecting broken rotor bars in a squirrel-cage induction motor. The air-gap flux variation analysis was done using search coils inserted in stator slots when broken rotor bar occurs. An accurate modeling and analysis of air-gap flux variation in the induction motor are developed using finite-element(FE) software packages, and measurement of the flux are made using search coils. The simulation was done for the induction motor with 380 [V]. 7.5 [kW], 4 Poles, 1,760 [rpm] ratings using the commercial FE analysis tool. The simulation and experiment results can be useful for detecting the broken rotor bar of an induction motor.

  • PDF