• 제목/요약/키워드: Stator Winding Insulation

검색결과 130건 처리시간 0.03초

고압절연용 Epoxy/Organoclay Nanocomposites의 열적, 전기적 특성에 관한 연구 (Thermal, Electrical Characteristics according to Contents Variation of Epoxy/Organoclay Nanocomposites for High Voltage Insulation)

  • 박재준;안준오
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.226-227
    • /
    • 2007
  • Nanostructured materials are attracting increased interest and application. Exciting perspectives may be offered by electrical insulation. Epoxy/Organoclay nanocomposites may find new and upgraded applications in the electrical industry, replacing conventional insulation to provide improved performances in electric power apparatus, e.g, high voltage motor/generator stator winding insulation, dry mold transformer, etc. This paper shows that electrical and thermal properties of epoxy/organoclay nanocomposites insulating materials for dsc, dielectric constant, I-V characteristics, breakdown volatge, can improve significantly with respect to the basic, virgin materials.

  • PDF

Detection of Incipient Faults in Induction Motors using FIS, ANN and ANFIS Techniques

  • Ballal, Makarand S.;Suryawanshi, Hiralal M.;Mishra, Mahesh K.
    • Journal of Power Electronics
    • /
    • 제8권2호
    • /
    • pp.181-191
    • /
    • 2008
  • The task performed by induction motors grows increasingly complex in modern industry and hence improvements are sought in the field of fault diagnosis. It is essential to diagnose faults at their very inception, as unscheduled machine down time can upset critical dead lines and cause heavy financial losses. Artificial intelligence (AI) techniques have proved their ability in detection of incipient faults in electrical machines. This paper presents an application of AI techniques for the detection of inter-turn insulation and bearing wear faults in single-phase induction motors. The single-phase induction motor is considered a proto type model to create inter-turn insulation and bearing wear faults. The experimental data for motor intake current, rotor speed, stator winding temperature, bearing temperature and noise of the motor under running condition was generated in the laboratory. The different types of fault detectors were developed based upon three different AI techniques. The input parameters for these detectors were varied from two to five sequentially. The comparisons were made and the best fault detector was determined.

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • 양상현;박노준;김충식;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF

6.6kV 회전기 부분방전 측정용 Capacitive Coupler 특성 (Characteristics of Capacitive Coupler for Partial Discharge Measurement in 6.6kV Rotating Machines)

  • 강동식;윤대희;김용주;윤영호;이정준;송상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1619-1622
    • /
    • 2001
  • Recently many researches on the diagnosis of stator winding insulation for large rotating machines have been developed sine the 1970s. Capacitive coupler has been the most widely used sensor for on-line partial discharge(PD) in rotating machines. The 105 [pF] ceramic coupler(CC) has been developed to continuously measure the PD activity in operating motor stator windings. This paper presents frequency characteristics and laboratory test to compare traditional 80 [pF] epoxy-mica coupler(EMC) and 105 [pF] CC for PD measurement in 6.6 [kV] stator windings.

  • PDF

고압전동기 운전중 부분방전 감시 시스템 개발 (Development of On-Line Partial Discharge Monitoring System in High Voltage Motors)

  • 김희동;공태식;주영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

발전기 운전에 따른 고정자 권선의 진동 특성 변화 (A Study on the Change of Dynamic Characteristics of Stator Windings due to Generator Operation)

  • 김희수;배용채;이두영;김연환;이현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1029-1033
    • /
    • 2006
  • During operation of generator, the excitation force with 120Hz always exist irrespective of No. of poles. Therefore the vibration is generated in the stator end windings and the micro-crack is grown up inside the bars. After all, coolant water is leaked outside the bars or the stator is moved and is worn out. What is more, one bar is touched with another bar so a short circuit may frequently happen in operation. In order to prevent it from occurring, the evaluation of mechanical integrity for generator stator windings is carried out periodically during overhaul period. This help troublesome end windings to complement with insulation material and to change vibration characteristics. In this paper, the evaluation of mechanical integrity for generator stator windings is described and the change of vibration characteristics is analysed.

  • PDF

대용량 수치발전기의 절연진단에 의한 절연상태평가 (Assessment of Insulation Condition for Hydro-generator)

  • 이광호;박종진;김기원;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1810-1812
    • /
    • 2002
  • This test was performed to assess the insulation deterioration condition of the stator winding of Chung-Ju hydrogenerator #4 and Dae-Cheong hydrogenerator #2 which had been in service after being constructed 1980. The insulation diagnostic tests include resistance polarization index(P.I.) AC current, dissipation factor(Tan ${\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to factory test measurements.

  • PDF

견인전동기의 고장예측 및 신뢰성 평가를 위한 복합가속열화 상태진단 - 절연저항 및 성극지수 특성 연구 (Condition Diagnosis by the Complex Accelerating Degradation for fault Prediction & estimation of reliability on the traction motor - Insulation Resistance & Polarization Index Properties)

  • 왕종배;변윤섭;백종현;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1374-1376
    • /
    • 2000
  • In this paper, sample coils for stator form-wound winding of traction motor were tested by the accelerative thermal degradation, which composed of heat, vibration, moisture and overvoltage applying. Reliability and expected life were evaluated on the insulation system for 200 class traction motor. After aging of 10 cycles, insulation resistance and PI properties were investigated as diagnosis tests in the range of $20{\sim}160^{\circ}C$. Analysis of polarization properties was performed on the base of do current-time change.

  • PDF

고압유도전동기의 절연상태 평가 (Evaluation of Insulation Condition for High Voltage Induction Motor)

  • 이광호;임재일;김기원;정진달;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.783-785
    • /
    • 2003
  • This test was performed to assess the insulation deterioration condition of the stator winding of 3.3kV class induction motors which have been in service for 15 years after being installed in 1988. The insulation diagnostic tests include resistance, polarization index(P.I). dissipation factor(${\Delta}tan{\delta}$) and maximum partial discharges(Qmax). The results of diagnostic tests were compared to the visual inspection in overhaul.

  • PDF

견인전동기의 복합가속열화 상태진단에 의한 고장예측 및 신뢰성 평가 (Fault Prediction & Reliability Estimation of the Traction Motor by the Complex Accelerating Degradation and Condition Diagnosis)

  • 왕종배;김명룡
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.763-766
    • /
    • 2000
  • In this paper, stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the 200 Class insulation system of traction motors. The complex accelerative degradation was performed by periods during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of 20∼160$^{\circ}C$. Relationship among condition diagnosis test was analyzed to find an dominative degradation factor and an insulation state at end-life point.

  • PDF