A Study on the Change of Dynamic Characteristics of Stator Windings due to Generator Operation

발전기 운전에 따른 고정자 권선의 진동 특성 변화

  • 김희수 (한국전력공사 전력연구원) ;
  • 배용채 (한국전력공사 전력연구원) ;
  • 이두영 (한국전력공사 전력연구원) ;
  • 김연환 (한국전력공사 전력연구원) ;
  • 이현 (한국전력공사 전력연구원)
  • Published : 2006.05.01

Abstract

During operation of generator, the excitation force with 120Hz always exist irrespective of No. of poles. Therefore the vibration is generated in the stator end windings and the micro-crack is grown up inside the bars. After all, coolant water is leaked outside the bars or the stator is moved and is worn out. What is more, one bar is touched with another bar so a short circuit may frequently happen in operation. In order to prevent it from occurring, the evaluation of mechanical integrity for generator stator windings is carried out periodically during overhaul period. This help troublesome end windings to complement with insulation material and to change vibration characteristics. In this paper, the evaluation of mechanical integrity for generator stator windings is described and the change of vibration characteristics is analysed.

Keywords