• Title/Summary/Keyword: Stator winding

Search Result 425, Processing Time 0.061 seconds

Study on the Post-Assembly Magnetization Method of Permanent Magnet Motor (영구자석형 전동기의 조립 후 착자 방법에 대한 연구)

  • Lee, C.K.;Kwon, B.I.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.104-106
    • /
    • 2003
  • In this paper, we study about the stator winding magnetization method and the magnetizing fixture magnetization method in post-assembly magnetization. Most of small electrical machine use the stator winding magnetization method but it is impossible to magnetize the permanent magnet by the stator winding magnetization method when the capacity of machine increases and the coercive force of magnet increases. And the eddy current disturbs the magnetization seriously in case of LSPM(Line Start Permanent magnet Motor) that have conductor bar in rotor. Hence, the magnetization fixture is required. So, in this paper we study about the post-assembly magnetization method that can use the stator winding magnetization method or must use the magnetization fixture magnetization method.

  • PDF

A Study on the Diagnosis for Water Absorption of Generator Stator Windings (발전기 고정자 권선의 흡습 진단)

  • Bae Y.C.;Kim H.S.;Lee D.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.297-298
    • /
    • 2006
  • Water leak for the water-cooled generator stator windings affects seriously the availability and the reliability of power plants. Generally, water absorption test is conducted in the power plant during outage in order to confirm if leak part is in the bars or not. In this paper, it is described that the capacitance of winding bars is measured by using the developed water absorption instrument system and the water absorption of winding bars is evaluated by using the stochastic methods. The good results by proposed diagnosis technique can be got. It is expected that the reliability of diagnosis for water absorption is increased if the proposed methods are applied to evaluate the water absorption of stator winding bars.

  • PDF

Automatic Diagnosis for Stator Winding Faults Using Distortion Ratio (왜곡률을 이용한 고정자 권선고장 자동진단)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Yang, Chul-Oh
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.358-360
    • /
    • 2007
  • In this paper, an auto-diagnosis method of the stator winding fault for small induction motor is suggested. 3-phase stator currents are sampled, filtered, and transformed with Park's vector transformation. After then Park's vector patterns are obtained. To detect the stator winding fault automatically, a distortion ratio (id/iq) is newly defined and compared with the one of healthy motor, and the threshold levels are suggested. The 2-turn, 4-turn, 8-turn winding fault are tested with no load, 25%, 50%, 75%, and 100% rated load. The distortion ratio of the Park's vector patterns are increased as the increase of the faulted turns, but are same as the increase of the load.

  • PDF

Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor (고압전동기 고정자권선의 부분방전 특징추출)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.7 no.4
    • /
    • pp.61-69
    • /
    • 2004
  • On-line monitoring of fault discharge is an important approach for indicating the condition of electrical insulation of stator winding in high voltage motor. In this paper, several key aspects of on-line monitoring system are discussed, involving the characteristics of fault discharge of stator winding in high voltage motor, spectrum analysis of four simulation fault signals, feature extraction of internal fault discharge from apply voltage to breakdown. The study of the partial discharge activities allows to highlight the ageing stage in the winding fault under test. During the life of the winding insulation fault, the shape of PD signal change relating to the ageing stage. The ageing of stator winding insulation fault of high voltage motor is investigated based on the characteristics of partial discharge pulse distribution and statistical parameters, such as maximum, skewness and kurtosis using discrete wavelet trnasform coefficients.

  • PDF

Design and Characteristics Analysis on Linear Synchronous Motor with Long Stator and Phase Concentrated Winding (긴고정자 상집중권 선형 동기 전동기의 설계 및 특성 해석)

  • Kim, Jeong-Man;Cho, Han-Wook;Jang, Seok-Myeong;Jo, Jeong-Min;Han, Young-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.54-62
    • /
    • 2014
  • This study deals with the design and characteristics analysis on a linear synchronous motor (LSM) with a long stator and phase concentrated winding (PCW) to apply for a propulsion system such as a roller coaster for leisure facilities. First of all, the required propulsion force of LSM is computed and its design with double sided permanent magnets (PMs) and a phase concentrated winding is processed. The phase concentrated winding is composed of a module with each A, B, and C phase unlike an conventional concentrated winding (CW). It has an advantage of the installation and manufacture, compared to the conventional concentrated winding in the propulsion system for leisure facilities that have a long acceleration area and stator configuration placed on rail continuously. Thus, the design for the propulsion system and characteristics comparison between the phase concentrated winding and concentrated winding are carried out in this paper. Also, the analysis on dynamic characteristics is conducted to confirm the performance at operation.

Pattern of partial discharge for stator windings fault of high voltage motor (고압전동기 고정자권선 결함 부분방전패턴)

  • Park, Jae-Jun;Kim Hee-Dong
    • The Journal of Information Technology
    • /
    • v.7 no.1
    • /
    • pp.155-161
    • /
    • 2004
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in imitation stator winding of high voltage motors. The motor was energized to 4.47kV, 6.67, respectively. Applied voltage to Imitation winding was used two voltage level, 4.47[kV] and 6.67[kV]. Motors having imitation stator winding were installed with 80pF capacitive couplers at the terminal box. Case of PD Pattern regarding applied voltage phase angel, the PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). As the result, we could discrimidate using TGA the difference of internal and surface discharge for imitation stator winding. We have used the other technique, in order to feature extraction of faulty signals on stator winding, Daubechies Discrete wavelet transform and Harmonics analysis(FFT) about faulty signals.

  • PDF

A Study on the Improvement of Dynamic Characteristics of the Motor Stator Coil Winding Machine (모터 고정자 코일 권선기의 동특성 개선 연구)

  • Kim, Dong-Sung;Kim, Kwang-Young;Ham, Sang-Yong;Son, Young-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1589-1596
    • /
    • 2003
  • In this paper, we performed the improvement study for the dynamic characteristics enhancement of the motor stator coil vertical winding machine. The dynamic characteristics improvement was done by means of the optimized design and the weight reduction of the flyer configuration, modified design of the servo control system for the flyer and the former actuation, and the development of jump timing digital circuit for the reduction of former jumping error. As the results, the maximum winding speed pattern of the developed machine was attained up to 3000rpm and also reduced the jumping error. In conclusion, domestic design technology for manufacturing the motor coil vertical winding machine was established through this study.

A Study on the Partial Discharge Wave Propagation along Stator Winding (회전기 권선의 펄스 전송특성 연구)

  • Kang, Dong-Sik;Sim, Woo-Yong;Hwang, Don-Ha;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.738-740
    • /
    • 2003
  • A lot of R&D on the diagnosis of stator winding insulation for large rotating machines has been carried out since the 1970s. The on-line partial discharge measurement has proved to be an effective technique in the evaluation of the state of stator insulation in high voltage rotating machines. It is well known that if the discharge pulses propagate through the winding conductor, they are attenuated and delayed. In the present study, to investigate the attenuation and the time delay of discharge pulses through the winding conductor, a series of tests were conducted using a model coils and slot. Thus it could be concluded that while the high frequency pulse propagates in radiation or end-winding coupling modes, the low frequency one does in a series mode through the coil conductor.

  • PDF

Assessment of Insulation Condition in Gas Turbine Generator Stator Windings (가스터빈 발전기 고정자 권선의 절연상태 평가)

  • Kim, Hee-Dong;Yang, Gyu-Hyun;Ju, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1423-1428
    • /
    • 2010
  • The results of off-line and on-line diagnostic tests performed on the stator winding of an air-cooled gas turbine(G/T) generator are reported in this paper. Off-line diagnostic tests included measurements of the ac current, dissipation factor(tan${\delta}$), and partial discharge(PD). Six epoxy-mica capacitors were installed in the three phases of G/T generator for performing on-line diagnostic testing with the turbine generator analyzer(TGA). The TGA showed that the normalized quantity number(NQN) and the PD magnitude($Q_m$) were high in phase A of the stator winding. Internal discharges were generated in phases B and C, and slot discharge occurred in phase A. According to the trend analyses of the NQN and $Q_m$ values available for insulation condition assessment for G/T generator stator windings, it was concluded that phases B and C were in good condition, whereas phase A has been significantly deteriorated.

Optimal Stator Slot Design of Inverter-Fed Induction Motor for Reduction of Core and Winding Losses (손실 저감을 위한 인버터 구동 유도 전동기의 고정자 슬롯 형상 최적화)

  • Kim, Jae-Woo;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.86-88
    • /
    • 2004
  • In this paper, optimal stator slot shape of 3-phase inverter-fed induction motor is designed to reduce stator core and winding losses. For the analysis, the F.E.M on 1 phase band periodic condition in stator is coupled with harmonic equivalent circuit. For the optimal design, the conjugate gradient method is used as an optimizing algorithm. The stator core and winding losses are reduced by the design method. The results are verified by those of the time-step finite element analysis.

  • PDF