• 제목/요약/키워드: Statistical power

검색결과 1,611건 처리시간 0.03초

중전압 전선의 통계적 수명예측 계산과 응용 방법 (Statistical Life Expectancy Calculation of MV Cables and Application Methods)

  • 조종은;이온유;김상봉;김강식
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.61-68
    • /
    • 2022
  • In this paper, the change history of various types of MV (Medium Voltage) cables was investigated. In addition, the statistical life expectancy of each type was calculated by using the operation data and the failure data. For cut-off year, 10 years was applied, and realistically applicable statistical life expectancy was calculated by correcting the cause of failure entered by mistake. The life expectancy of FR-CNCO-W was calculated as 51.2 years, CNCV-W 38.1 years, and CNCV 31.4 years and the overall average is 33.8 years. Currently, the life expectancy of TR CNCV-W is 29.4 years, but it is estimated that the lifespan will be extended if failure data is accumulated. As a result, it is expected that life expectancy results can be applied to Asset Management System (AMS) in the future.

LPATS를 이용한 한반도 뇌격파라메터의 통계분포에 관한 연구('96~'98) (A Study on the Statistical Analysis of Lightning Parameters by Lpats in Korea ('96~'98))

  • 우정욱;심응보;정길조;김정부;이건웅
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권5호
    • /
    • pp.310-314
    • /
    • 2000
  • To study the basic research of the lightning parameters for power system operation, LPATS(Lightning Positioning and Tracking System) has been introduced since 1995 in KEPCO(Korea Electric Power Corporation). We have developed the lightning parameters analysis program which can produce accumulative magnitude distribution of lightning current and IKL map by LPATS data. We obtained the various statistical distributions of lightning current parameters since 1996 by the lightning analysis program for the pertinent insulation design. In this paper, we describe the LPATS system in KEPCO, the statistical distribution of lightning current parameters and the IKL(Isokeraunic Level) map from 1996 to 1998. And the compared results between the calculated LFOR(lightning flashover rate) and the observed rate are also described.

  • PDF

전력용 변압기 운전수명 특성의 통계적 분석(I) (The Statistical Analysis of Operating Life Characteristic on Poler Transformers(I))

  • 강동식;김광화;권동진;김문덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1885-1887
    • /
    • 1996
  • Power transformers are the most important facilities in the substation of electrical power, yet they do not have the efficient operating life characteristics which are the important elements of repairing and maintenance in regional conditions. This paper describes the statistical analysis of operating conditions and troubles on transformers for the operating life assessment using Statistical Analysis System programs, Hazard method and Weibull distributions. We analyze transformers in several methods, and compares correlation relationship of operating life and troubles. Therefore, this study will be the useful basic operating life prediction technique of power transformers in the future.

  • PDF

A STUDY ON THE EFFECT OF POWER TRANSFORMATION IN SPATIAL STATISTIC ANALYSIS

  • LEE JIN-HEE;SHIN KEY-IL
    • Journal of the Korean Statistical Society
    • /
    • 제34권3호
    • /
    • pp.173-183
    • /
    • 2005
  • The Box-Cox power transformation is generally used for variance stabilization. Recently, Shin and Kang (2001) showed, under the Box-Cox transformation, invariant properties to the original model under the large mean and relatively small variance assumptions in time series analysis. In this paper we obtain some invariant properties in spatial statistics. Spatial statistics, Invariant Property, Variogram, Box-Cox power Transformation.

A Validation Model for the Statistical Power Balance Method Using a Reverberation Chamber

  • Lee, Young Seung;Choi, Sung Woong;Park, Seung Keun
    • Journal of electromagnetic engineering and science
    • /
    • 제13권3호
    • /
    • pp.192-194
    • /
    • 2013
  • This paper proposes a validation model using a reverberation chamber for verification of the effectiveness and accuracy of the statistical power balance (PWB) method. The PWB method treats electromagnetic (EM) field distributions in certain environments as a representative value of an "ensemble" average, so a reverberation chamber is utilized as a testing apparatus to experimentally simulate the sets of measurement field "ensemble" inside a complex environment. Measurements are performed with various test conditions for environmental loss using flat absorbers, and front and side doors of the chamber. Comparison between the PWB analysis and the measurement results shows good agreement, indicating the usefulness of this statistical analysis method for stating the electromagnetic field inside the EM zone as a representative value to general structures.

Monte Carlo simulation for verification of nonparametric tests used in final status surveys of MARSSIM at decommissioning of nuclear facilities

  • Sohn, Wook;Hong, Eun-hee
    • Nuclear Engineering and Technology
    • /
    • 제53권5호
    • /
    • pp.1664-1675
    • /
    • 2021
  • In order to verify the statistical performance of the nonparametric tests used in the MARSSIM approach, all plausible contamination distribution types that can be encountered in a survey area should be investigated. As the first of such investigations, this study aims to perform the verification for normal distribution of the contamination in a survey area by simulating the collection of random samples from it through the Monte Carlo simulation. The results of the simulations conducted for a total of 81 simulation cases showed that Sign test and WRS test both exhibited an excellent statistical performance: 100% for the former and 98.8% for the latter. Therefore, in final status surveys of the MARSSIM approach, a high statistical performance can be expected in applying the nonparametric hypothesis tests to survey areas whose net contamination can be assumed to be normally distributed.

압전 지능 구조물을 이용한 통계적 에너지 해석 기법 (Application of Piezoelectric Smart Structures for Statistical Energy Analysis)

  • 김재환;김정하;김재도
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.257-264
    • /
    • 2001
  • In this research, piezoelectric smart structures are applied for SEA(Statistical Energy Analysis), which is well known approach for high frequency analysis. A new input power measurement based on piezoelectric electrical power measurement is proposed and compared with the conventional method in SEA. As an example, a simple aluminum beam on which piezoelectric actuator is attached is considered. By measuring the electrical impedance and electrical current of the piezoelectric actuator, the electrical power given on the actuator is found and this is In turn converted into the mechanical energy. From the measured value of the stored energy of the beam, the Internal loss factor is calculated and this value shows a good agreement with that given by the conventional method as well as the theoretical value. To compare the coupling loss factor, L-shape beam system which consists of a aluminum beam subsystem and a steel beam subsystem coupled by three pin is taken as second example. The input power and stored energy of each subsystem are found by the proposed approach. The coupling loss factor found by the electrical input power obtained from the piezoelectric actuator exhibits similar trend to the value found by the conventional method as well as the theoretical value. In conclusion, the use of SEA for high frequency application of piezoelectric smart structures is Possible. Especially, the input power that is essential for SEA can be found accurately by measuring the electrical input power of the piezoelectric actuator.

  • PDF

고장데이터를 이용한 대용량 전력설비 통계적 수명분석 (Statistical Lifetime Analysis for Large Electric Power Equipments using Failure Data)

  • 김정태
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1605-1611
    • /
    • 2017
  • In this study, the characteristic lifetime of power facilities such as power transformers and GIS were investigated as the basis of power facility asset management. It is difficult to obtain the operation and failure data of the facilities in Korea. Therefore, the number of failures of the electric power facilities was calculated from the operation data and hazard rate shown in the overseas literatures, and the statistical analysis was performed using the Weibull distribution function. As a result of extracting and analyzing the data of the UK National Grid for power transformers, the characteristic lifetime (scale parameter) of 116.45 years was considered to be a very appropriate value for power transformer management and can be used as a comparative data of the analysis of the domestic transformers. As for the GIS, based on the Bays and Bay-Years data and the hazard rate according to the operation years of the 123kV GIS in Germany, it is found out that the characteristic lifetime of GIS is not so meaningful. It is necessary to decide a maintenance strategy and lifetime expectancy considering the characteristics of the design, materials and manufacturing process of GIS.

Topological and Statistical Analysis for the High-Voltage Transmission Networks in the Korean Power Grid

  • Kang, Seok-Gu;Yoon, Sung-Guk
    • 한국통신학회논문지
    • /
    • 제42권4호
    • /
    • pp.923-931
    • /
    • 2017
  • A power grid is one of the most complex networks and is critical infrastructure for society. To understand the characteristics of a power grid, complex network analysis has been used from the early 2000s mainly for US and European power grids. However, since the power grids of different countries might have different structures, the Korean power grid needs to be examined through complex network analysis. This paper performs the analysis for the Korean power grid, especially for high-voltage transmission networks. In addition, statistical and small-world characteristics for the Korean power grid are analyzed. Generally, the Korean power grid has similar characteristics to other power grids, but some characteristics differ because the Korean power grid is concentrated in the capital area.

복잡한 대형 구조물의 효율적인 전자파 해석을 위한 통계적인 PWB 방법의 유용성에 관한 연구 (A Study on the Utility of Statistical Power Balance Method for Efficient Electromagnetic Analysis of Large and Complex Structures)

  • 이영승;박승근
    • 한국전자파학회논문지
    • /
    • 제24권2호
    • /
    • pp.189-197
    • /
    • 2013
  • 전자 통신 기술의 발전 추세에 따라 유비쿼터스 환경이 구축되면서 일상 생활에서 전자 기기의 밀집도는 폭발적으로 증가하는 추세를 보이고 있다. 이러한 다양한 전자 기기들이 ICT 건물 등의 사회 기반 시설에 설치될 시 이들 사이의 전자파 적합성 및 간섭 분석과 파악을 위해서는 효율적이고도 빠른 대형 구조물의 전자파 해석기법이 필수적이다. 이에 본 논문에서는 이러한 전자파 해석을 위하여 확률론적 기반의 PWB(Power Balance Method) 해석 방법을 소개하고 그 유용성을 고찰한다. 기존의 맥스웰 방정식에 입각한 결정론적 해석 결과와의 관계를 제시하기 위해 손실이 존재하는 2차원 직각 캐비티(cavity)에서 시뮬레이션을 수행하여, PWB 방법의 기저에 깔린 가정 및 통계적인 결과가 하나의 결정론적 문제에서 필드 분포의 부피 평균(volume average)에 해당함을 보였다. 복잡한 대형 구조물에서 full-wave 전자파 해석이 계산 비용과 시간적인 측면에서 큰 한계점이 있음은 이미 자명한 사실이므로, 통계적인 개념에 기반을 둔 본 PWB 해석 방법이 대형 구조물의 전자파 해석에 있어서 충분히 현실적인 대안이 될 것이다.