• Title/Summary/Keyword: Statistical Calibration

Search Result 203, Processing Time 0.026 seconds

Development of Extended Process Capability Index in Terms of Error Classification in the Production, Measurement and Calibration Processes (생산, 측정 및 교정 프로세스에서 오차 유형화에 의한 확장 공정능력지수의 개발)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.117-126
    • /
    • 2009
  • We develop methods for propagating and analyzing EPCI(Extended Process Capability Index) by using the error type that classifies into accuracy and precision. EPCI developed in this study can be applied to the three combined processes that consist of production, measurement and calibration. Little calibration work discusses while a great deal has been studied about SPC(Statistical Process Contol) and MSA(Measurement System Analysis). EPCI can be decomposed into three indexes such as PPCI(Production Process Capability Index), PPPI(Production Process Performance Index), MPCI(Measurement PCD, and CPCI(Calibration PCI). These indexs based on the type of error classification can be used with various statistical techniques and principles such as SPC control charts, ANOVA(Analysis of Variance), MSA Gage R&R, Additivity-of-Variance, and RSSM(Root Sum of Square Method). As the method proposed is simple, any engineer in charge of SPC. MSA and calibration can use efficientily in industries. Numerical examples are presentsed. We recommed that the indexes can be used in conjunction with evaluation criteria.

Multivariate Linear Calibration with Univariate Controlled Variable

  • Park, Nae-Hyun
    • Journal of the Korean Statistical Society
    • /
    • v.15 no.2
    • /
    • pp.107-117
    • /
    • 1986
  • This paper gives some new results on the multivariate linear calibration problem in the case when the controlled variable is univariate. Firstly, a condition under which one can obtain a finite closed confidence interval of $x_0$(unknown controlled variable) is suggested. Secondly, this article considers a criterion to find out whether the multivariate calibration significantly shortens the confidence interval of $x_0$ and supports this criterion by examples. Finally, a multivariate extension of the results in Lwin Maritz (1982) is given.

  • PDF

A Bayesian Analysis in Multivariate Bioassay and Multivariate Calibration

  • Park, Nae-Hyun;Lee, Suk-Hoon
    • Journal of the Korean Statistical Society
    • /
    • v.19 no.1
    • /
    • pp.71-79
    • /
    • 1990
  • In the linear model which consider both the multivariate parallel-line bioassay and the multivariate linear calibration, this paper presents a Bayesian procedure which is an extension of Hunter and Lamboy (1981) and has several advantages compared with the non Bayesian techniques. Based on the methods of this article we discuss the effect of multivariate calibration and give a numerical example.

  • PDF

Preliminary Analysis of Data Quality and Cloud Statistics from Ka-Band Cloud Radar (Ka-밴드 구름레이더 자료품질 및 구름통계 기초연구)

  • Ye, Bo-Young;Lee, GyuWon;Kwon, Soohyun;Lee, Ho-Woo;Ha, Jong-Chul;Kim, Yeon-Hee
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2015
  • The Ka-band cloud radar (KCR) has been operated by the National Institute of Meteorological Research (NIMR) of Korea Meteorological Administration (KMA) at Boseong National Center for Intensive Observation of severe weather since 2013. Evaluation of data quality is an essential process to further analyze cloud information. In this study, we estimate the measurement error and the sampling uncertainty to evaluate data quality. By using vertically pointing data, the statistical uncertainty is obtained by calculating the standard deviation of each radar parameter. The statistical uncertainties decrease as functions of sampling number. The statistical uncertainties of horizontal and vertical reflectivities are identical (0.28 dB). On the other hand, the statistical uncertainties of Doppler velocity (spectrum width) are 2.2 times (1.6 times) larger at the vertical channel. The reflectivity calibration of KCR is also performed using X-band vertically pointing radar (VertiX) and 2-dimensional video disdrometer (2DVD). Since the monitoring of calibration values is useful to evaluate radar condition, the variation of calibration is monitored for five rain events. The average of calibration bias is 10.77 dBZ and standard deviation is 3.69 dB. Finally, the statistical characteristics of cloud properties have been investigated during two months in autumn using calibrated reflectivity. The percentage of clouds is about 26% and 16% on September to October. However, further analyses are required to derive general characteristics of autumn cloud in Korea.

Study of statistical distribution for four-port TEM cell

  • Jeon, Sangbong;Kwon, Jong-Hwa
    • Journal of Multimedia Information System
    • /
    • v.1 no.2
    • /
    • pp.127-132
    • /
    • 2014
  • The transverse electromagnetic (TEM) cells are widely used for electromagnetic compatibility (EMC) testing and field probe calibrations. We propose the verification of TEM mode with statistical method using a four-port TEM cell. The verification results are compared with Normal, Rayleigh, and Gamma distribution. As a result, the 75 % quantile of the Rayleigh distribution is excellent agreement with the true quantiles for a number of calibration points.

  • PDF

Statistical analysis for RMSE of 3D space calibration using the DLT (DLT를 이용한 3차원 공간검증시 RMSE에 대한 통계학적 분석)

  • Lee, Hyun-Seob;Kim, Ky-Hyeung
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • The purpose of this study was to design the method of 3D space calibration to reduce RMSE by statistical analysis when using the DLT algorithm and control frame. Control frame for 3D space calibration was consist of $1{\times}3{\times}2m$ and 162 contort points adhere to it. For calculate of 3D coordination used two methods about 2D coordination on image frame, 2D coordinate on each image frame and mean coordination. The methods of statistical analysis used one-way ANOVA and T-test. Significant level was ${\alpha}=.05$. The compose of methods for reduce RMSE were as follow. 1. Use the control frame composed of 24-44 control points arranged equally. 2. When photographing, locate control frame to center of image plane(image frame) o. use the lens of a few distortion. 3. When calculate of 3D coordination, use mean of 2D coordinate obtainable from all image frames.

A Study for the Unit Nonresponse Calibration using Two-Phase Sampling Method

  • Yum, Joon Keun;Jung, Young Mee
    • Communications for Statistical Applications and Methods
    • /
    • v.9 no.2
    • /
    • pp.479-489
    • /
    • 2002
  • The case which applies two-phase sampling to stratification and nonresponse problem, it is a poweful and effective technique. In this paper we study the calibration estimator and its variance estimator for the population total using two-phase sampling method according to the of auxiliary information for population and sample having strong correlation with an interested variable in unit nonresponse situation. The auxiliary information that available both at first-phase and second-phase sampling can be used to improve weights by the calibration procedure. A weight which corresponds to the product of sampling weights and response probability is calculated at each phase of sampling.

Partial optional randomized response technique with calibration weighting to adjust non-response in successive sampling

  • Priyanka, Kumari;Trisandhya, Pidugu;Kumar, Ajay
    • Communications for Statistical Applications and Methods
    • /
    • v.28 no.5
    • /
    • pp.493-510
    • /
    • 2021
  • The present article endeavours to develop partial optional randomized - response technique (PORT) to deal with sensitive issues in presence of non-response in successive sampling. Calibration techniques have been embedded with PORT to estimate sensitive population mean at current move in two move successive sampling in presence of non-response. Optimum calibration weights are computed at each move with the aid of constraints based on auxiliary information. Detailed properties of the proposed estimators have been discussed. Possible cases in which non-response may creep at two moves has been explored. The proposed technique has been compared with the modified existing technique. Simulation results indicate that the proposed technique is more efficient than existing, modified one. Suitable recommendations are forwarded.

GENERATING NUC TABLES BASED ON STATISTICAL DATA COLLECTION FOR KOMPSAT-2 WITHIN LEOP

  • Song, Jeong-Heon;Park, Su-Young
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.788-790
    • /
    • 2006
  • The algorithm of calculating NUC table, based on Image data collection, is based on two basic assumptions. These basic assumptions are as follow: one is the NUC is of a linear nature. The other is all pixel see the same statistical distribution for large number of lines. We generated NUC tables for a radiometric calibration & validation of KOMPSAT-2 using a dark cal. Data.

  • PDF

On Bootstrapping; Bartlett Adjusted Empirical Likelihood Ratio Statistic in Regression Analysis

  • Woochul Kim;Duk-Hyun Ko;Keewon Lee
    • Journal of the Korean Statistical Society
    • /
    • v.25 no.2
    • /
    • pp.205-216
    • /
    • 1996
  • The bootstrap calibration method for empirical likelihood is considered to make a confidence region for the regression coefficients. Asymptotic properties are studied regarding the coverage probability. Small sample simulation results reveal that the bootstrap calibration works quite well.

  • PDF