• Title/Summary/Keyword: Static offset test

Search Result 14, Processing Time 0.023 seconds

The Behavior of Bearing Capacity for the Precast files (기성말뚝의 지지거동)

  • 박영호
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.107-116
    • /
    • 2000
  • Dynamic and static load tests are conducted in four construction sites by using steel pipe piles(SPP) and concrete piles to compare differences of load bearing mechanism. Steel pipe piles are instrumented with electric strain gages and are subject to dynamic load tests during driving. The damage of strain gages attached is checked simultaneously. Static load test is also conducted on the same piles after two to seven days' elapse. Then load-settlement behavior and shaft and/or tip resistances are measured. As a result, the allowable bearing capacity calculated by the Davisson's offset method of CAPWAP analysis shows 2~33% larger than that of static load test. The average value of allowable bearing capacity of static load test is closer to the allowable capacity obtained at the safety factor of 2.5 applied on ultimate bearing capacity than to the one obtained from the Davisson's offset method. The analysis of strain gage readings shows that unit skin friction increases with depth. Furthermore, the friction mobilized around the 1~2m above the pile tip considerably contributes to the total shaft resistance.

  • PDF

A Built-in Self-Test of Static Parameters for Analog-to-Digital Converters (아날로그-디지털 변환기의 정적 파라미터 테스트를 위한 내장 자체 테스트 방법)

  • Kim, In-Cheol;Jang, Jae-Won;Kang, Sung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.5
    • /
    • pp.30-36
    • /
    • 2012
  • A new BIST(Built-In Self-Test) scheme to test ADC(Analog-to-Digital Converter) with a transition detector is proposed. The proposed BIST is able to replaces histogram method, the most popular approach in static testing of ADC. With a ramp signal as an input test stimulus, the proposed BIST calculates ADC's static parameters such as offset, gain, INL(Integral Non-Linearity) and DNL(Differential Non-Linearity). The three detectors in the proposed BIST can deal with a transient zone problem, a phenomenon due to random noise in real test environments and are cost efficient at various acceptable ranges determined as a test spec. The simulation results validate that our method performs accurate static test and show the reduction of the hardware overhead.

Study on Design of Truncated Mooring Line with Static Similarity in Model Test Basins (모형수조에서 정적 상사성을 지닌 절단계류선 모델링에 관한 연구)

  • Kim, Yun-Ho;Kim, Byoung-Wan;Cho, Seok-Kyu
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.257-265
    • /
    • 2017
  • In this study, a series of numerical simulations was conducted in order to design a truncated mooring line with a static similarity to the prototype. A finite element method based on minimizing the potential energy was utilized to describe the dynamics of mooring lines. The prototype mooring lines considered were installed at a water depth of 1,000 m, whereas the KRISO ocean engineering basin (OEB) in Daejeon has a water depth of 3.2 m, which represents 192 m using a scaling of 1:60. First, an investigation for the design of the truncated mooring line was carried out to match the static characteristics of the KRISO Daejeon OEB environment. Then, the same procedure was performed with the KRISO new deepwater ocean engineering basin (DOEB) that is under construction in Busan. This new facility has a water depth of 15 m, which reflects a real scale depth of 900 m considering the 1:60 scaling factor. A finite element method was used to model the mooring line dynamics. It was found that the targeted truncated mooring line could not be designed under the circumstances of the KRISO OEB with any material properties, whereas several mooring lines were easily matched to the prototype under the circumstances of the KRISO DOEB.

Implementation of DGPS Postprocessing System by Offset Distance (위치 편차에 의한 DGPS 후처리 시스템의 구현)

  • Choi, Hyun-Ki;Lee, Yong-Kuk;Suk, Bong-Chool;Kim, Hak-Il
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.3 no.2 s.6
    • /
    • pp.221-225
    • /
    • 1995
  • Unauthorized users cant acquire and enough accuracy in applications of the navigation or geodesy by the single GPS positioning technique because of the measurement errors and US DoDs intentional errors. The solution of these restrictions is the Dgps technique that is to eliminate the common errors between the reference station and the desired point and can achieve a high accuracy. DGPS postprocessing system is implemented by using the offset distances between the known position of a reference station and the position obtained from GPS satellite data. The preliminary experiments include static tests and a dynamic test of cruising a ship.

  • PDF

A Study on a Digital Amplifier.Controller for Proportional Control Valve (비례제어밸브용 디지털 앰프.컨트롤러에 대한 연구)

  • Lee, J.C.;Koh, J.U.;Kwon, T.H.;Shin, H.B.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.1
    • /
    • pp.19-25
    • /
    • 2011
  • This study presents the design of digital amplifier.controller for a proportional control valve and the development of PID discrete control scheme by using RCP(Rapid Controller Prototyping) system. RCP system is the device to embed the control code developed in PC into the microcontroller on-site. Ramp input test using the digital amplifier.controller developed in this study was carried out for the proportional control valve of domestic production and Bosch Rexroth respectively. The instability problem occurred around maximum displacement of localized valve spool at ramp input test was solved by supplementing offset current to the duty ratio of PWM(Pulse Width Modulation) driving signal to the solenoid. The comparison of test results between localized proportional control valve and Bosch Rexroth's product shows that the characteristics obtained by ramp input test and static flow gains are alike each other. Two valves are about the same in dead bands and hysteresis characteristics.

Developed 3-axis Educational CNC Machine Tool (3축 CNC 교육용 공작기계 개발)

  • Jang, Sung-Wook
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.627-635
    • /
    • 2019
  • In this study, we developed for processing complex features using CAM software that satisfies precision for example practice and related qualification tests suiTable for CNC training purposes. In addition, functions such as location control, speed control, and processing path generation, which are the main functions of CNC machining machines, were constructed using small equipment parts, servo motors, inverters, general purpose PCs, and commercial NC software and researched with the goal of developing low-cost education equipment. In the static accuracy inspection, the degree of machine when measuring the parallelism of the X, Y and Z axes and the vibration of the main shaft did not reach the allowable value. However, we have obtained a finished product that satisfies the CNC machine book sample shape machining, detailed functions of the position control function of the CNC machine tool, linear interpolation function, circular interpolation function, and tool offset function. In the qualification test shape processing, a shape with a degree of 1/100 mm was processed to obtain position accuracy that satisfied the tolerance.

Parameter Study for the Analysis of Impact Characteristics considering Dynamic Material Properties (동적 물성치를 고려한 V.I. 충격인자의 영향 분석)

  • Lim, J.H.;Song, J.H.;Huh, H.;Park, W.J.;Oh, I.S.;Choe, J.W.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.945-950
    • /
    • 2001
  • Vacuum interrupters that is used in various switchgear components such as circuit breakers, distribution switches, contactors, etc. spreads the arc uniformly over the surface of the contacts. The electrode of vacuum interrupters is used sintered Cu-Cr material satisfied with good electrical and mechanical characteristics. Because the closing velocity is 1-3m/s, the deformation of the material of electrodes depends on the strain rate and the dynamic behavior of the sintered Cu-Cr material is a key to investigate the impact characteristics of the electrodes. The dynamic response of the material at the high strain-rate is obtained from the split Hopkinson pressure bar test using cylinder type specimens. Experimental results from both quasi-static and dynamic compressive tests with the split Hopkinson pressure bar apparatus are interpolated to construct the Johnson-Cook equation as the constitutive relation that should be applied to simulation of the dynamic behavior of electrodes. To evaluate impact characteristic of a vacuum interrupter, simulation is carried out with five parameters such as initial velocity, added mass of a movable electrode, wipe spring constant, initial offset of a wipe spring and virtual fixed spring constant.

  • PDF

Systematic comparisons among OpenFAST, Charm3D-FAST simulations and DeepCWind model test for 5 MW OC4 semisubmersible offshore wind turbine

  • Jieyan Chen;Chungkuk Jin;Moo-Hyun Kim
    • Ocean Systems Engineering
    • /
    • v.13 no.2
    • /
    • pp.173-193
    • /
    • 2023
  • Reliable prediction of the motion of FOWT (floating offshore wind turbine) and associated mooring line tension is important in both design and operation/monitoring processes. In the present study, a 5MW OC4 semisubmersible wind turbine is numerically modeled, simulated, and analyzed by the open-source numerical tool, OpenFAST and in-house numerical tool, Charm3D-FAST. Another commercial-level program FASTv8-OrcaFlex is also introduced for comparison for selected cases. The three simulation programs solve the same turbine-floater-mooring coupled dynamics in time domain while there exist minor differences in the details of the program. Both the motions and mooring-line tensions are calculated and compared with the DeepCWind 1/50 scale model-testing results. The system identification between the numerical and physical models is checked through the static-offset test and free-decay test. Then the system motions and mooring tensions are systematically compared among the simulated results and measured values. Reasonably good agreements between the simulation and measurement are demonstrated for (i) white-noise random waves, (ii) typical random waves, and (iii) typical random waves with steady wind. Based on the comparison between numerical results and experimental data, the relative importance and role of the differences in the numerical methodologies of those three programs can be observed and interpreted. These comparative-study results may provide a certain confidence level and some insight of potential variability in motion and tension predictions for future FOWT designs and applications.

Parameter Study of Impact Characteristics for a Vacuum Interrupter Considering Dynamic Material Properties (동적 물성치를 고려한 진공 인터럽터 충격특성의 영향인자 분석)

  • Lim, Ji-Ho;Song, Jeong-Han;Huh, Hoon;Park, Woo-Jin;Oh, Il-Seong;Ahn, Gil-Young;Choe, Jong-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.5
    • /
    • pp.924-931
    • /
    • 2002
  • Vacuum interrupters in order to be used in various switch-gear components such as circuit breakers, distribution switches, contactors, etc. spread the arc uniformly over the surface of the contacts. The electrodes of vacuum interrupters are made of sinter-forged Cu-Cr materials for good electrical and mechanical characteristics. Since the closing velocity is 1-2m/s and impact deformation of the electrode depends on the strain rate at that velocity, the dynamic behavior of the sinter-forged Cu-Cr is a key to investigate the impact characteristics of the electrodes. The dynamic response of the material at the high strain rate is obtained from the split Hopkinson pressure bar test using disc-type specimens. Experimental results from both quasi-static and dynamic compressive tests are Interpolated to construct the Johnson-Cook model as the constitutive relation that should be applied to simulation of the dynamic behavior of the electrodes. The impact characteristics of a vacuum interrupter are investigated with computer simulations by changing the value of five parameters such as the initial velocity of a movable electrode, the added mass of a movable electrode, the wipe spring constant, initial offset of a wipe spring and the virtual fixed spring constant.

Multiscale Wavelet-Galerkin Method in General Two-Dimensional Problems (일반 형상의 2차원 영역에서의 멀티스케일 웨이블렛-갤러킨 기법)

  • Kim, Yun-Yeong;Jang, Gang-Won;Kim, Jae-Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.5
    • /
    • pp.939-951
    • /
    • 2002
  • We propose a new multiscale Galerkin method based on interpolation wavelets for two-dimensional Poisson's and plane elasticity problems. The major contributions of the present work are: 1) full multiresolution numerical analysis is carried out, 2) general boundaries are handled by a fictitious domain method without using a penalty term or the Lagrange multiplier, 3) no special integration rule is necessary unlike in the (bi-)orthogonal wavelet-based methods, and 4) an efficient adaptive scheme is easy to incorporate. Several benchmark-type problems are considered to show the effectiveness and the potentials of the present approach. is 1-2m/s and impact deformation of the electrode depends on the strain rate at that velocity, the dynamic behavior of the sinter-forged Cu-Cr is a key to investigate the impact characteristics of the electrodes. The dynamic response of the material at the high strain rate is obtained from the split Hopkinson pressure bar test using disc-type specimens. Experimental results from both quasi-static and dynamic compressive tests are Interpolated to construct the Johnson-Cook model as the constitutive relation that should be applied to simulation of the dynamic behavior of the electrodes. The impact characteristics of a vacuum interrupter are investigated with computer simulations by changing the value of five parameters such as the initial velocity of a movable electrode, the added mass of a movable electrode, the wipe spring constant, initial offset of a wipe spring and the virtual fixed spring constant.