• 제목/요약/키워드: Static load capacity

검색결과 530건 처리시간 0.025초

Effect of Earthquake characteristics on seismic progressive collapse potential in steel moment resisting frame

  • Tavakoli, Hamid R.;Hasani, Amir H.
    • Earthquakes and Structures
    • /
    • 제12권5호
    • /
    • pp.529-541
    • /
    • 2017
  • According to the definition, progressive collapse could occur due to the initial partial failure of the structural members which by spreading to the adjacent members, could result in partial or overall collapse of the structure. Up to now, most researchers have investigated the progressive collapse due to explosion, fire or impact loads. But new research has shown that the seismic load could also be a factor for initiation of the progressive collapse. In this research, the progressive collapse capacity for the 5 and 15-story steel special moment resisting frames using push-down nonlinear static analysis, and nonlinear dynamic analysis under the gravity loads specified in the GSA Guidelines, were studied. After identifying the critical members, in order to investigate the seismic progressive collapse, the 5-story steel special moment resisting frame was analyzed by the nonlinear time history analysis under the effect of earthquakes with different characteristics. In order to account for the initial damage, one of the critical columns was weakened at the initiation of the earthquake or its Peak Ground Acceleration (PGA). The results of progressive collapse analyses showed that the potential of progressive collapse is considerably dependent upon location of the removed column and the number of stories, also the results of seismic progressive collapse showed that the dynamic response of column removal under the seismic load is completely dependent on earthquake characteristics like Arias intensity, PGA and earthquake frequency contents.

Static UPS 병렬운전 제어 (The Control of Parallel Operation for Static UPSs)

  • 김동욱;김연풍;신현주;백병산;류승표;민병권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2048-2050
    • /
    • 1998
  • An uninterruptible power supply(UPS) with parallel operation is used to increase the power capacity of the system or to secure higher reliability at critical loads. In the parallel operating system composed of the multiple UPSs, load-sharing, i.e. current balance control between them is key technique. Because of its low impedance and quick response characteristics, inverter output current changes very rapidly and thereby easily researches an overload condition. The difference between total load current divided by number of operating inverters and its own current is detected as unbalanced current. Then frequency and voltage are controlled to minimize the active component and the reactive component. A good performance of the proposed load-sharing technique is verified by experiments in the parallel operating system with two 40kVA UPSs.

  • PDF

스틸보강재가 부착된 프로파일 및 고강도 모르타르를 이용한 균열손상 콘크리트관의 보강효과 (Reinforcement Effect of Cracked Concrete Tubes and Box Culverts by Installing Profile with Steel Stiffener and High Strength Mortar)

  • 여상록;조은상;황원섭;정재운
    • 대한토목학회논문집
    • /
    • 제28권1A호
    • /
    • pp.69-78
    • /
    • 2008
  • 본 논문에서는 내하력이 저감된 노후화 된 콘크리트 하수관거의 보강공법의 타당성을 검증하기 위하여 정적재하 시험을 실시하였다. 내경 0.8 m, 1.0 m, 1.5 m인 원형관과 폭 2.0 m, 2.5 m인 상자형관을 대상으로 하였으며, 신관을 대상으로 정적 재하시험을 통하여 관 내부에 충분한 균열을 발생시킨 후 보강공법을 적용 한 후 다시 정적재하시험을 실시하였다. 본 연구에서 적용 된 보강공법은 균열관 내부에 스틸보강재가 추가된 프로파일과 고강도 모르타르를 이용하여 화학적 열화에 대한 저항성과 단면 내력을 증진 시킨 것이다. 보강공법 적용 후 단면 내력은 균열발생 이전 신관에 비해 원형관의 경우 1.66 ~3.50배, 상자형관의 경우 1.66~3.10배 정도 증가하였다. 또한 ABAQUS 6.6을 이용하여 보강공법 적용 전 후 콘크리트 원형관과 상자형관의 비선형 해석을 수행하였다. C3D8R 솔리드 요소를 사용하였고, concrete damage plasticity option을 적용하였다. 원형관과 상자형관에 배근된 철근의 영향성을 해석상 반영하기 위하여 합성 재료식을 유도하여 적용하였다.

Prediction of flexural behaviour of RC beams strengthened with ultra high performance fiber reinforced concrete

  • Murthy A, Ramachandra;Aravindan, M.;Ganesh, P.
    • Structural Engineering and Mechanics
    • /
    • 제65권3호
    • /
    • pp.315-325
    • /
    • 2018
  • This paper predicts the flexural behaviour of reinforced concrete (RC) beams strengthened with a precast strip of ultra-high performance fiber-reinforced concrete (UHPFRC). In the first phase, ultimate load capacity of preloaded and strengthened RC beams by UHPFRC was predicted by using various analytical models available in the literature. RC beams were preloaded under static loading approximately to 70%, 80% and 90% of ultimate load of control beams. The models such as modified Kaar and sectional analysis predicted the ultimate load in close agreement to the corresponding experimental observations. In the second phase, the famous fatigue life models such as Papakonstantinou model and Ferrier model were employed to predict the number of cycles to failure and the corresponding deflection. The models were used to predict the life of the (i) strengthened RC beams after subjecting them to different pre-loadings (70%, 80% and 90% of ultimate load) under static loading and (ii) strengthened RC beams after subjecting them to different preloading cycles under fatigue loading. In both the cases precast UHPFRC strip of 10 mm thickness is attached on the tension face. It is found that both the models predicted the number of cycles to failure and the corresponding deflection very close to the experimental values. It can be concluded that the models are found to be robust and reliable for cement based strengthening systems also. Further, the Wang model which is based on Palmgren-Miner's rule is employed to predict the no. of cycles to failure and it is found that the predicted values are in very good agreement with the corresponding experimental observations.

탄소섬유 Rod로 성능향상된 R/C보의 휨 거동 연구 (The Study on Flexural Behavior of Reinforced Concrete Beams Strengthened with the Carbon Fiber Rod)

  • 심종성;문도영;김영호;김동희
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.611-616
    • /
    • 2002
  • The concrete beam is quickly required to be replaced or strengthened due to decreasing load carrying capacity. Flexural tests on 3.1m long reinforced concrete beams with carbon-fiber rod are reported. The selected experimental variable is the method of the anchoring beam. The effects of this variable in overall behavior are discussed. This paper considered relation of load-displacement and load-strain. The maximum load was increased to the static behavior of the R/C beam strengthened with CFR rod. The results indicated generally that the flexural strength of strengthening beam was increased. It was required a proper anchorage system and can be led the ductility of beams of a carbon-fiber rod.

  • PDF

정지형 UPS의 병렬운전 제어 (The Parallel Operation Control of Static UPSs)

  • 민병권;원충윤
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권7호
    • /
    • pp.363-368
    • /
    • 1999
  • The parallel operation system of multiple uninterruptible power supplies(UPSs) is used to increase power capacity of the system or to secure higher reliability at critical loads. In the parallel operation of the two UPSs, the load-sharing control to maintain the current balance between them is a key technique. Because a UPS has low output impedance and quick response characteristics, in case of an unbalanced load inverter output current changes very rapidly and thereby can instantaneously reach an overload condition. In this study, high precise load-sharing controller is proposed and implemented for the parallel operation system of two UPSs with low impedance characteristics and this controller controls the frequency and the voltage to minimize the active power component and the reactive power component which are gotten from the current difference between two UPSs. And then a good performance of the proposed method is verified by experiments in the parallel operation system with two 40KVA UPSs.

  • PDF

정적하중과 사용하중하에서 유리 섬유로 보강된 교량 바닥판의 거동특성에 대한 비교 (Behavior Characteristics Comparison of Bridge Decks Strengthened with Glass Fiber Sheets On the Static Load and Service Load)

  • 심종성;오홍섭;류승무;김영호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.59-64
    • /
    • 2001
  • The concrete bridge decks are in need of replacement and rehabilitation due to decreasing load carrying capacity. In this study, to extend life cycle of the concrete bridge decks which are reinforced with the glass fiber sheets, the concrete bridge decks are examined on the strengthen effect and the fatigue behavior. The behavior of strengthened slabs is represented by load-displacement relationship, variation of compliance and total released energy. Owing to result of that, the strengthened slabs is modified the elasticity, the compliance and represents to control the crack elongation, to elevate the total released energy, to modify the fatigue life. When the concrete bridge deck is strengthened, the crack propagation nay be controled efficiently.

  • PDF

철도교용 IT거더의 피로특성 (Fatigue characteristics of the IT girder for railroad)

  • 최상현;이창수
    • 한국재난정보학회 논문집
    • /
    • 제6권2호
    • /
    • pp.119-130
    • /
    • 2010
  • In designing a railroad bridge, the fatigue is one of the main factors to be considered for ensuring safe operation. Especially, for a new type of a structural member, which has not been adopted to railroad bridges, the fatigue performance should be checked. In this paper, the fatigue characteristics of an IT girder are examined. The IT girder is a new type of a prestressed concrete girder which has two prestressed H-beams in the top of the girder to give the girder additional sectional capacity. To obtain the fatigue performance, a 10m IT girder specimen is designed, and a repeated load test is performed by applying the load cyclically two million times. The magnitude of the repeated load is determined considering the stress level under the service condition. During the test, static load tests are performed to identify the stiffness degradation. The fatigue performance of the girder is checked according to the Japanese and the CEB-FIB design codes. The fatigue test result shows that the IT girder satisfies both design codes.

Segmental PC 박스거더교의 검증재하시험 및 건전성평가 (Proof Load Test and Integrity Assessment of Segmental PC Box-girder Bridges)

  • 조효남;임종권;옥승범;지광습
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.132-141
    • /
    • 1995
  • This study is intended to propose practical but systematic and rational approaches for proof load test and integrity assessment of segmental PC box-girder bridges. The proposed models cover the whole range of field tests and assessment of such as inspections, nondestructive tests, static and dynamic load tests, structural analysis, and integrity assessment for the evaluation of load carrying capacity, serviceability, and durability of PC box-girder bridges. They are applied to a newly constructed precast segmental PC box-girder bridge which is a part of the Seoul interior circuit elevated expressway.

  • PDF

헬리컬 파일의 지지력 산정을 위한 양방향 재하시험의 적용성 평가 (Applicability of Bi-directional Load Test for Evaluating Bearing Capacity of Helical Piles)

  • 이동섭;나경욱;이원제;김형남;최항석
    • 한국지반신소재학회논문집
    • /
    • 제13권4호
    • /
    • pp.77-85
    • /
    • 2014
  • 헬리컬 파일(helical pile)은 회전 관입기로 시공이 가능하므로 비교적 소형의 장비로 말뚝 시공이 가능한 장점이 있어, 최근 다양한 현장에서 그 사용이 증가하고 있다. 그러나 헬리컬 파일의 지지력을 평가하기 위한 현장 정재하시험은 시험하중만큼의 사하중, 반력 말뚝, 반력 앵커 등이 필요하다는 단점이 있다. 본 연구에서는 헬리컬 파일에 상대적으로 재하장치가 간단하고 시험이 간편한 양방향 재하시험을 적용하였으며, 양방향 재하시험 결과와 정재하시험 결과를 비교하였다. 양방향 재하시험은 헬리컬 파일의 중공형 중심축(shaft)에 중심축의 직경과 일치하고 중심축 내부 공간으로 유압재하용 호스가 나올 수 있도록 특수하게 제작된 유압식 셀(cell)을 나선형 원판(helix plate)사이에 삽입한 후, 유압 셀(cell)에 가압하여 지지력을 측정하는 방식으로 수행되었다. 양방향 재하시험은 유압식 셀을 최하단 나선형 원판 상부에 삽입한 경우와 최상단 나선형 원판 상부에 삽입한 두 가지 케이스로 시험을 진행하였으며, 각각의 방법이 선단지지력과 주면마찰력을 측정할 수 있도록 말뚝 두부의 변형을 제한하였다. 시험은 89mm, 114mm의 중심축에 450mm, 350mm, 200mm의 나선형 원판을 부착하여 제작한 헬리컬 파일로 수행되었으며, 시험 결과 정재하시험으로 산정한 지지력과 양방향 재하시험으로 산정한 지지력이 유사함을 확인하였다.