• Title/Summary/Keyword: Static inverter

Search Result 159, Processing Time 0.025 seconds

Damping Oscillation of Power System by Robust Control of SSSC (강인 제어에 의한 Static Synchronous Series Compensator의 전력계통 동요 억제)

  • Kim, Hak-Man;Oh, Tae-Kyoo;Kook, Kyung-Soo;Jeon, Jin-Hong;Jang, Byung-Hoon;Chu, Jin-Bu
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1035-1038
    • /
    • 1999
  • To improve the damping of all poorly damped oscillation modes, a control strategy of Static Synchronous Series Compensator (SSSC) based on energy method is presented in this Paper As a synchronous voltage-sourced inverter, SSSC is used to provide controllable series compensation. SSSC can provide controllable compensating voltage over an identical capacitive and inductive range. The damping effect of control strategy based on energy function is robustness with respect to loading condition, fault location and network configuration. Furthermore, the control inputs are based on local signals. In two area system, the effect of damping inter-area mode oscillation is demonstrated by the robust control strategy of SSSC.

  • PDF

Modeling and Control of VSI type FACTS controllers for Power System Dynamic Stability using the current injection method

  • Park, Jung-Soo;Jang, Gil-Soo;Son, Kwang-M.
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.4
    • /
    • pp.495-505
    • /
    • 2008
  • This paper describes modeling Voltage Sourced Inverter (VSI) type Flexible AC Transmission System (FACTS) controllers and control methods for power system dynamic stability studies. The considered FACTS controllers are the Static Compensator (STATCOM), the Static Synchronous Series Compensator (SSSC), and the Unified Power Flow Controller (UPFC). In this paper, these FACTS controllers are derived in the current injection model, and it is applied to the linear and nonlinear analysis algorithm for power system dynamics studies. The parameters of the FACTS controllers are set to damp the inter-area oscillations, and the supplementary damping controllers and its control schemes are proposed to increase damping abilities of the FACTS controllers. For these works, the linear analysis for each FACTS controller with or without damping controller is executed, and the dynamic characteristics of each FACTS controller are analyzed. The results are verified by the nonlinear analysis using the time-domain simulation.

Dynamic Characteristics Analysis of Multi-bridge PWM Inverter SSSC (다중브리지 PWM 인버터로 구성된 SSSC의 동특성 분석)

  • 한병문;박덕희;김성남
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.296-302
    • /
    • 2001
  • This paper proposes a SSSC based on multi-bridge inverters. The dynamic characteristic of the proposed SSSC was analyzed by EMTP simulation and a scaled hardware model, assuming that the SSSC is inserted in the transmission line of the one-machine-infinite-bus power system. The proposed SSSC has 6 multi-bridge inverters per phase, which generates 13 pulses for each half period of power frequency. The proposed SSSC generates a quasi-sinusoidal output voltage by 90 degree phase shift to the line current. The proposed SSSC does not require the coupling transformer for voltage injection, and has a flexibility in operation voltage by increasing the number of series connection.

  • PDF

Reducing Train Weight and Simplifying Train Design by Using Active Redundancy of Static Inverters for the Onboard Supply of Rolling Stock

  • Bachmann, G.;Wimmer, D.
    • International Journal of Railway
    • /
    • v.1 no.3
    • /
    • pp.89-93
    • /
    • 2008
  • Reliability of onboard power supply systems on rolling stock is a very important issue for the railway operator. While a failure of the HVAC supply results in a loss of comfort for the passengers, a failure of the supply for air compressors or for the traction cooling systems results in towing the train. This is, looking at the required availability of a train, not acceptable. An active redundancy concept for the onboard power supply maximizes the availability of the system. This paper describes such a system under the aspect of $\cdot$ Weight reduction $\cdot$ Continuous operation when changing from normal to redundant operation $\cdot$ Flexibility in train design.

  • PDF

A Study on the Urban Transit Vehicle Reliability Improvement Method using Quality Control Technique (품질관리기법을 이용한 도시철도차량 신뢰도 향상방안 연구)

  • Park, Kee-Jun
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.860-869
    • /
    • 2011
  • It is very important that reduce the maintenance cost and extend life time of the urban transit EMU through effective maintenance method research. The maintenance cost of the urban transit EMU shares 60%~70% of it's life cycle cost. It means that the maintenance cost is bigger than the introduction cost of the urban transit EMU. In this study, I introduces a quality control technique to improve the urban transit vehicle reliability. I suggest the control chart using quality control technique. And the control charts apply to the Static Inverter of EMU.

  • PDF

Dynamic Coordination Strategies between HVDC and STATCOM

  • Kim, Chan-Ki;Sood, Vijay;Lee, Seok-Jin
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.892-902
    • /
    • 2009
  • This paper deals with the dynamic voltage control problem at the inverter end of a HVDC link when connected to a weak AC system which has the potential for harmonic instability and commutation failures. The dynamic voltage control problem is tackled with a STATCOM (Static Compensator), which not only provides a rapid recovery from harmonic instability and commutation failures but also offers a lower cost filter design for HVDC systems. PSCAD/EMTDC simulations are presented to validate the proposed topology and to demonstrate its robust performance.

A study on the converter of auxiliary power supply for electric railway vehicles (전기 철도차량용 보조전원장치의 컨버터에 관한 연구)

  • Kim, Jae-Moon;Kim, Yang-Soo;Lee, Jong-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.467-468
    • /
    • 2007
  • This paper describes characteristics of converters of auxiliary power supply for electric railway vehicles. Auxiliary power supply is called Static Inverter(SIV) which supplied lamps, air conditioning and heat equipments, control systems, etc. Simulation results shows that line No.1 cheon contains low harmonics compared with those of KTX.

  • PDF

Dynamic Characteristic Analysis of Multi-bridge SSSC (다중브리지로 구성된 SSSC의 동특성 분석)

  • 한병문;박덕희;백승택;김희중;소용철;김현우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.229-237
    • /
    • 2000
  • 본 논문에서는 멀티브리지 인버터로 구성된 SSSC를 제안하였다. SSSC의 동적특성을 분석하기 위해서 1기 무한모선 전력계통에 SSSC를 연결한 것을 가정하고 EMTP 시뮬레이션을 수행하였고, 축소모형 실험으로 그 특성을 확인하였다. 다중브리지 SSSC는 한 상당 6개의 단상 풀브리지 인버터로 구성되었고, 13-레벨 출력전압을 얻을 수 있다. 다중브리지 SSSC는 전압 주입을 위한 연계 변압기가 필요하기 않고, 전력계통에서 요구되는 동작전압에 따라 브리지 수를 가감하여 용이하게 구성할 수 있다.

  • PDF

Dead Time Compensation of Grid-connected Inverter Using Resonant Controller (공진 제어기를 이용한 계통 연계형 인버터의 데드타임 보상)

  • Han, Sang-Hyup;Park, Jong-Hyoung;Kim, Heung-Geun;Cha, Honn-Yong;Chun, Tea-Won;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.569-576
    • /
    • 2011
  • This paper proposes a new dead time compensation method for a PWM inverter. Recently, PWM inverters are extensively used for industry applications, such as ac motor drives, distributed grid-connected systems and a static synchronous compensator (STATCOM). Nonlinear characteristics of the switch and the inverter dead time cause a current distortion and deterioration of power quality. The dominant harmonics in the output current are the $5^{th}$ and $7^{th}$ harmonics in the stationary frame, and the $6^{th}$ harmonics in the synchronous rotating frame. In this paper, a resonant controller which compensates the $6^{th}$ harmonics in the synchronous rotating frame is proposed. This method does not require any off-line experimental measurements, additional hardware and complicated mathematical computations. Furthermore, the proposed method is easy to implement and does not cause any stability problem.

A Study on the High Performance Slip Power Recovery System in Induction Motor (유도전동기의 고성능 슬립전력 회수방식에 대한 연구)

  • Park, Han-Ung;Park, Seong-Jin;An, Jin-U;Park, Jin-Gil;Kim, Cheol-U;Hwang, Myeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.431-439
    • /
    • 1999
  • Among the variable-speed AC motor drive systems, the static slip power recovery system has been widely adopted in large power drives because a high efficiency drive can be obtained by recovering the slip power to the AC line. Although many improvements have been made in this system, several problems also remain such as the need of transformer in inverter AC side, which results in limiting speed control range and increasing the losses, production of reactive power by the control of inverter firing angle, harmonics in line currents, and so on. This paper presents the novel high performance slip power recovery system using the boost converter and small size filter in the rotor circuit, which recovers slip power of a wound rotor induction machine to AC supply efficiently with the aid of the boost converter, in which most of the problems in conventional system can be solved. The speed can be controlled by the duty ratio of the converter switch, not by inverter firing angle. As a results, the proposed system can operate in high power factor and the harmonic currents caused by the inverter and rectifier can be considerably suppressed. The validity of the proposed system verified by demonstrating the good agreement in the simulation and experimental results.

  • PDF