• 제목/요약/키워드: Static current

검색결과 1,036건 처리시간 0.023초

와전류 제동장치를 포함한 한국형 고속전철 대차의 정적강도 및 피로강도 평가 (Evaluation of Static Strength and Fatigue Strength for Bogie of a Korea High Speed Train Including Eddy Current Brake System)

  • 노규석;이상록;강재윤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.267-272
    • /
    • 2001
  • A FEM-based analytical approach was used to evaluate the static strength and the fatigue strength of a KHST bogie including eddy current brake system. Calculation was carried out in the fields of linearity and small deformation. The yield strengths were used as criteria for evaluating the static strength and the fatigue limits were used as criteria for evaluating the fatigue strength. The analysis results show that there is not any location that exceeds the allowable criteria.

  • PDF

중간주파수 대역에서 준정적(Quasi-Static) FDTD 기법을 이용한 인체 유도전류 분석 (Analysis of Body Induced Current in Middle Frequency Range Using Quasi-Static FDTD)

  • 변진규
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.141-149
    • /
    • 2009
  • 본 논문에서는 준정적 FDTD 기법을 FORTRAN 프로그래밍을 통해 직접 구현하고 이를 이용해 중간주파수 대역의 인체유도전류 분포를 해석하였다. 제작된 프로그램의 타당성을 검증하기 위하여 기존 FDTD 기법을 적용하기 어려운 테스트 모델에 대한 계산결과를 이론적 해와 비교하고, 타임스텝이 크게($5.68{\times}10^6$배) 단축되는 것을 확인하였다. 검증된 수치해석 기법을 이용하여 20[kHz] 자기장과 1[MHz] 전기장에 노출된 3차원 고해상도 인체모델에 유기되는 유도전류의 분포를 계산하고, 양 발의 접지조건이 유도전류의 분포와 크기에 미치는 영향을 분석하였다. 본 연구는 인체유도전류의 안전성 평가, 생체전기 응용 진단장치 개발 등을 포함한 다양한 분야에서 활용될 것으로 기대된다.

Beta 방사선원을 이용한 정전기 제거법에 대한 고찰 (A study on the elimination of static electricity by use of beta radiation source)

  • 임용규
    • 전기의세계
    • /
    • 제14권3호
    • /
    • pp.28-33
    • /
    • 1965
  • This experiment is based on "the feasible improvement studies for an eliminating device of the static electricity which applies the ionizing effect of beta radiation." In order to accomplish this object, the following problems were necessarily considered to investigate and to determine. The efficiency of the elimination of static electricity was determined by means of measuring the ion current between electrically charged plates with micro-ammeter. The effects of various factors, i.e., the distance between charged plate and radiation source, the activity of radiation source, the electric otential and the area of the charged plate, the shape of the source housing, the lining of backscattering material (Pb) on the source housing surface and blowing of ionized air, on the static electricity eliminating efficiency were studied. The beta radiation sources used in this experiment were S$^{35}$ and Sr$^{90}$ -Y$^{90}$ . It was revealed that ion current increased with source activity, the electric potential and area of the plates, the lead (Pb) lining on the surface of the source housing and the velocity of the ionized air blowing. As one could expect the S$^{35}$ was more effective to increase the ion current since it is known to be a higher specific ionization source than Sr$^{90}$ -Y$^{90}$ . The detailed result and performance of the eliminating device of the static electricity are described here.ibed here.

  • PDF

변압기절연재료의 유동대전특성에 미치는 제인자 연구 (A STUDY ON THE FACTOR OF STATIC ELECTRIFICATION ON TRANSFORMER INSULATING-MATERIALS)

  • 이숭녕;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1143-1145
    • /
    • 1995
  • In this paper, we measured leakage current that produced by static electrification at pressboard and insulating paper. We found that the leakage current increased as temperature increased, as oil velocity increased. The leakage current at pressboard is higher than that of insulating paper.

  • PDF

배전용 정지형 보상기의 위상변이를 이용한 순시 유효/무효전력 보상 (Instantaneously Active/Reactive Power Compensation of Distribution Static Compensator using Phase Shift)

  • 홍성민;최종우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.468-469
    • /
    • 2010
  • DSTATCOM(Distribution STATic COMpensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Conventional researches use a LPF(Low Pass Filter) to eliminate ripple component at the calculation of compensation current. This paper proposes a calculation of compensation current using phase shift that can be a counterproposal of conventional methods using LPF.

  • PDF

주축모터 전류를 통한 절삭력의 간접 측정 및 절삭력 추종제어 (Indirect Cutting Force Measurement and Cutting Force Regulation Using Spindle Motor Current)

  • 김기대;권원태;주종남
    • 한국정밀공학회지
    • /
    • 제14권10호
    • /
    • pp.15-27
    • /
    • 1997
  • Quasti-static cutting force variations in milling process are measured indirectly using spindle motor current. Quasi-static sensitivity of the spindle motor current is higher than that of the feed motor current. Magnitude of the spindle motor current is independent of cutting direction. The linear relationship between the cutting force and the spimdle motor RMS current at various spindle rotational speed is obtained. Frequency/ Voltage(F/V) converter voltage is measured to identify the spindle speed and to determine the cutting force at various spindle speeds. Overload on the tool during milling process can be detected using the proposed indirect cutting force measurement. Based on these measurements, cutting force is regulated at a constant level by feedrate control.

  • PDF

Technique for the Prevention of Inrush Current in a TCC Reactive Power Compensator

  • Yang, Ji-Hoon;Song, Sung-Geun;Park, Seong-Mi;Park, Sung-Jun
    • 한국산업융합학회 논문집
    • /
    • 제21권4호
    • /
    • pp.149-158
    • /
    • 2018
  • With the propagation and spread of the new regeneration energy and increase in electricity demand, power systems tend to be decentralized, and accordingly, the use of a power system stabilizer tends to expand for the stabilization of the distribution system. Thus, typical power system stabilizer, Static Var Compensator (SVC) is developed on a variety of topologies. In addition, the trend of technology leads from SVC to Static Synchronous Compensator(STATCOM) technology development. Recently, to overcome STATCOM's conversion losses and economic disadvantages, studies of a hybrid method using STATCOM and SVC in parallel have actively been conducted. This study proposes a new Soft-Step Switching method to limit inrush current problematic in Thyristor Controlled Capacitor (TCC) method in SVC function. In addition, to reduce Statcom's capacity, groups of reactive power compensation reactor and condenser for SVC were designed.

반도체 R&D BPR 시뮬레이션 (Resource Based Simulation in Semiconductor Business)

  • 김원경;이종복
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2001년도 춘계 학술대회 논문집
    • /
    • pp.31-35
    • /
    • 2001
  • Simulation --- The ideal tool for BPR. Work now and CASE tools are static modeling tools. Based on our own customers surveys, we have discovered that the use of process modeling tools thus far has focused on modeling the current(What-Is) state of a business. We have found that 90 percent of reengineering projects, the modeling tools of choice have been flowcharting tools. Static models offer help in understanding the overall nature of an existing process. However, static models can not really help you see the step by step motions towards completion of your goals. In static modeling, you see two pictures in time, usually taken at the current state and final state models of your reengineering project. Static models are usually not object oriented, therefore can not show facility or office layout and movement of entities and objects throughout the facility. However, this does not mean that static modeling does not have its application nor add value to the user as in a few success stories. Simulation helps the team analyze the complex aspects of the project. Many times a plan that looks good on paper might turn out entirely different when put into action. Therefore, simulation helps you look at how situations might work before actual implementation. In particular, computer simulation models help you view a reengineered condition before they are rolled-out. Items such as a lead time and resource allocation.

  • PDF

반도체 레이저의 전류 차단층 구조들이 정적 및 동적특성에 미치는 영향 (The structural dependence of current blocking layers on the static and dynamic performances in a direct modulated semiconductor laser)

  • 김동철;심종인;박문규;강중구;방동수;장동훈;어영선
    • 한국광학회지
    • /
    • 제14권4호
    • /
    • pp.423-428
    • /
    • 2003
  • 직접 변조형 반도체 레이저 다이오드에서 전류차단층의 구조들이 누설전류 및 대역폭에 미치는 영향을 조사하였다. 전류차단층을 통한 누설전류는 전류-전압미분특성 곡선을 통하여, 전류차단층의 기생성분들이 대역폭에 미치는 영향은 차감법(Subtraction method)을 사용하여 분석하였다. 실험결과로부터 정적 및 동적특성에 동시에 우수한 특성을 보이는 전류차단층 구조로서‘inin’형 차단구조가 매우 효과적임을 밝혔다.

Design and Analysis of Current Mode Low Temperature Polysilicon TFT Inverter/Buffer

  • Lee, Joon-Chang;Jeong, Ju-Young
    • Journal of Information Display
    • /
    • 제6권4호
    • /
    • pp.11-15
    • /
    • 2005
  • We propose a current mode logic circuit design method for LTPS TFT for enhancing circuit operating speed. Current mode inverter/buffers with passive resistive load had been designed and fabricated. Measurement results indicated that the smaller logic swing of the current mode allowed significantly faster operation than the static CMOS. In order to reduce the chip size, both all pTFT and all nTFT active load current mode inverter/buffer had been designed and analyzed by HSPICE simulation. Even though the active load current mode circuits were inferior to the passive load circuits, it was superior to static CMOS gates.