• Title/Summary/Keyword: Static condition

Search Result 1,223, Processing Time 0.022 seconds

Side Shear Resistance of Drilled Shafts in Weathered Rock (풍화된 암반에 근입된 현장타설말뚝의 주면지지력)

  • Kwon, Oh Sung;Kim, Myoung Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4C
    • /
    • pp.205-212
    • /
    • 2008
  • In this research, the effect of rock mass weathering on the side shear resistance of drilled shaft socketed into igneous-metamorphic rock was investigated. For that, 23 cast-in-place concrete piles with diameters varying from 400mm to 1,500mm were constructed at four different sites, and the static axial load tests were performed to examine the resistant behavior of the piles. A comprehensive field/laboratory testing program at the field test site was also performed to describe the in situ rock mass conditions quantitatively. The side shear resistance of rock socketed piles was found to have no intimate correlation with the compressive strength of the intact rock. However, the global rock mass strength, which was calculated by the Hoek and Brown criteria, was found to closely correlate to the side shear resistance. The ground investigation data regarding the rock mass conditions (e.g. $E_m$, $E_{ur}$, $p_{lm}$, RMR, RQD, j) were also found to be highly correlated with the side shear resistance, showing the coefficients of correlation greater than 0.75 in most cases. Additionally, the applicability of existing methods for the side shear resistance of weathered granite-gneiss was verified by comparison with the field test data. The existing methods which consider the effect of rock mass condition were modified and/or extended for weathered rock mass where mass factor j is lower than 0.15, and RQD is below 50%.

Evaluation of Structural Performance in CFT Truss Girder with the Arch-Shaped Lower Chord (아치형상의 하현재를 갖는 CFT 트러스 거더의 구조성능 평가)

  • Chung, Chul-Hun;Song, Na-Young;Ma, Hyang-Wook;Oh, Hyun-Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.315-327
    • /
    • 2009
  • In this study, the static test of CFT truss girders for different f/L ratios was conducted to determine how the ultimate strength of the CFT truss girder was affected by different f/L ratios. A total of two CFT truss girders were constructed and tested under bending condition. The length of all specimens is 20,000 mm. The CFT truss girder is a tubular truss composed of chord members made of concrete-filled circular tubes. The main parameter analyzed in the experimental study was the f/L ratio. This factor was experimentally investigated to assess their influence on ultimate strength and stiffness. The test results show that CFT truss girder has good elastic-plastic property and ductility. The presence of the f/L ratios in CFT truss girders alters its ultimate strength because of the global stiffness of the CFT truss girders. The ultimate strength of CFT truss girders increases as the f/L ratio increases. If the f/L ratio of the CFT truss girders increases twofold, the ultimate strengths increase by 80%. The CFT truss girders showed that they retained large deformation capacity, even after reaching the ultimate strength. Results of this investigation demonstrated the potential for efficiently using a CFT truss as a bridge girder.

Comparison of the Effects on Balance Abilities in the Women Elderly with Application TENS versus Balance Training (TENS 적용과 균형운동이 여성노인의 균형능력에 미치는 효과 비교)

  • Lee, Seung Won;Lee, Wan Hee
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.993-1003
    • /
    • 2010
  • his study was to investigate effects of improvement of balance abilities through 8-weeks Transcutaneous Electrical Nerve Stimulation (TENS) and balance training in the women elderly. 42 women elders who were participated in silver college. Randomized study design of two groups was used: TENS group (21 women, 84.53 years old) and balance training group(21 women, 79.93 years old). Each group had a application of TENS, balance training by a researcher three times per week for 8 weeks. Measurements of static postural sway velocity on the floor and foam, timed get up and go test (TUG), functional reach test (FRT), and lateral functional reach test (LFRT) were evaluated at initial presentation (pretest) and after completion of the each intervention program (posttest). The results showed that the TUG was significantly decreased in all groups (p<.05) and the postural sway velocity using force plate in all conditions was significantly decreased in all groups (p<.05). FRT and LFRT were significantly increased in all groups (p<.05). There were significantly differences in TUG and postural sway velocity on the eye closed condition between two groups (p<.05). In conclusion, the application of TENS to older adults whose somatosensory were deteriorated was effective for improvement balance ability.

A Study of Statistic Behavior of Segmental U-shaped Prestressed Concrete Girder Applied with Integrated Tensioning Systems (복합긴장방식이 적용된 세그멘탈 U형 거더 정적 거동 연구)

  • Hyunock Jang;Ilyoung Jang
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.329-338
    • /
    • 2024
  • Purpose: This study verified the safety of the improved box-type girder behavior by comparing and evaluating the bending behavior results of a full-scale specimen based on the analytical behavior of the splice element PSC U-shaped girder with integrated tensioning systems. Method: Based on the results of the service and strength limit state design using the bridge design standard(limit state design method), the applied load of a 40m full-scale specimen was calculated and a static loading experiment using the four-point loading method was performed. Result: When the design load, crack load, and ultimate load were applied, the specimen deflection occurred at 97.1%, 98.5%, and 79.0% of the analytical deflection value. When the design load, crack load, and ultimate load were applied, the crack gauge was measured at 0.009~0.035mm, 0.014~0.050mm, and 6.383~5.522mm at each connection. Conclusion: The specimen behaved linear-elastically until the crack load was applied, and after cracks occurred, it showed strainhardening up to the ultimate load, and it was confirmed that the resistance of bending behavior was clearly displayed against the applied load. The cracks in the dry joints were less than 25% of grade B based on the evaluation of facility condition standard. The final residual deformation after removing the ultimate load was 0.114mm, confirming the stable behavior of the segment connection.

Effects of Relaxation Techniques on Flexibility and Balance of the Lower Limb in Adults with Hamstring Shortening (넙다리뒤근 단축이 있는 성인에게 이완 기법의 적용이 하지의 유연성과 균형에 미치는 영향)

  • Jung-Woo Lee;Seong-Min Jeon;Ha-Yeong Kim;Jong-Yeon Bae;Song-Chan Son;Eun-Jin Song;Sang-Eun Sim;Hyeong-Uk Lee;Hye-Kyeong Lee;Baek-Gwang Jo;Sung-Bin Jo;Jin-Hee Joo;Ha-Yeon Jin;Jeong-Hyeon Hwang;Min-Hee Kim
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.55-70
    • /
    • 2024
  • Purpose: The purpose of this study was to investigate the effects of three relaxation techniques, namely, Static Stretching Exercise (SSE), Eccentric Contraction Exercise (ECE), and Suboccipital Muscle Release (SMR) on the flexibility and balance of the lower limb in adults with hamstring shortening. Methods: The participants were 45 adults in their 20s with hamstring shortening. They performed three exercises (i.e., SSE, ECE, and SMR) for two weeks. We measured flexibility, muscle tone and stiffness, proprioception, and balance before and after the intervention, applying each relaxation technique. Data were analyzed using two-way repeated measures analysis of variance (ANOVA). The significance level was set at α=0.05. Results: Flexibility increased in the SSE, ECE, and SMR groups, with the SSE group showing the greatest improvement. Muscle tone and stiffness decreased in all groups, with the ECE group exhibiting the highest reduction. Proprioception increased in the SSE, ECE, and SMR groups, with SSE demonstrating the greatest enhancement. Balance also increased in all groups, with the ECE group showing the most pronounced improvement. Conclusion: Overall, all three relaxation techniques for hamstring shortening resulted in improved flexibility, muscle tone and stiffness, proprioception, and balance of the lower limb in adults with hamstring shortening. The findings of this study underscore the importance of selecting an appropriate technique according to the purpose of treatment and the condition of the patient.

Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy (호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가)

  • Lee, Yang-Hoon;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2010
  • Purpose: The purpose of this study is that through production of phantom for respiration gated radiotherapy, assessing appropriacy of exposure dose for the therapy using RPM (Real-time Position Management). Materials and Methods: We located measurement object on the phantom for respiration gated radiotherapy made of 2 linear actuator, acrylic panel, stanchion, iron plate ets. to drive (up, down, front, back). Using 4D CT scan, we analyzed patient's respiration and reproduced the movement by computer. On the phantom, we located a 2D-Array (PTW) and an White water phantom (4.5 cm) and used DMLC (interval 2 cm) in the field size $10{\times}10\;cm$, then exposed 21EX X-ray 100 MU, in the case of phantom was (1) static (2) moving (3) gated using RPM respectively gantry $0^{\circ}$ and $90^{\circ}$ We measured with a 0.125 CC ionization chamber (PTW) on the phantom (7.5 cm) in the same condition. Results: Ionization chamber: There were within 0.3% of error with gating respiration and approximately 2% of error without gating in the same condition. 2D-Array: Gantry $90^{\circ}$, field size $10{\times}10\;cm$, using DMLC. There were within 3% of error with gating respiration and approximately 16% of error without gating. Conclusion: The phantom for respiration gated radiotherapy makes plans considering patient's movement, quantitative analysis of exposure dose and proper assessment therapy for IMRT patients using RPM possible.

  • PDF

Electrochemical Characteristics of Cu3Si as Negative Electrode for Lithium Secondary Batteries at Elevated Temperatures (리튬 이차전지 음극용 Cu3Si의 고온에서의 전기화학적 특성)

  • Kwon, Ji-Y.;Ryu, Ji-Heon;Kim, Jun-Ho;Chae, Oh-B.;Oh, Seung-M.
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.2
    • /
    • pp.116-122
    • /
    • 2010
  • A $Cu_3Si$ film electrode is obtained by Si deposition on a Cu foil using DC magnetron sputtering, which is followed by annealing at $800^{\circ}C$ for 10 h. The Si component in $Cu_3Si$ is inactive for lithiation at ambient temperature. The linear sweep thermammetry (LSTA) and galvano-static charge/discharge cycling, however, consistently illustrate that $Cu_3Si$ becomes active for the conversion-type lithiation reaction at elevated temperatures (> $85^{\circ}C$). The $Cu_3Si$ electrode that is short-circuited with Li metal for one week is converted to a mixture of $Li_{21}Si_5$ and metallic Cu, implying that the Li-Si alloy phase generated at 0.0 V (vs. Li/$Li^+$) at the quasi-equilibrium condition is the most Li-rich $Li_{21}Si_5$. However, the lithiation is not extended to this phase in the constant-current charging (transient or dynamic condition). Upon de-lithiation, the metallic Cu and Si react to be restored back to $Cu_3Si$. The $Cu_3Si$ electrode shows a better cycle performance than an amorphous Si electrode at $120^{\circ}C$, which can be ascribed to the favorable roles provided by the Cu component in $Cu_3Si$. The inactive element (Cu) plays as a buffer against the volume change of Si component, which can minimize the electrode failure by suppressing the detachment of Si from the Cu substrate.

STANDARDIZATION OF WORD/NONWORD READING TEST AND LETTER-SYMBOL DISCRIMINATION TASK FOR THE DIAGNOSIS OF DEVELOPMENTAL READING DISABILITY (발달성 읽기 장애 진단을 위한 단어/비단어 읽기 검사와 글자기호감별검사의 표준화 연구)

  • Cho, Soo-Churl;Lee, Jung-Bun;Chungh, Dong-Seon;Shin, Sung-Woong
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.14 no.1
    • /
    • pp.81-94
    • /
    • 2003
  • Objectives:Developmental reading disorder is a condition which manifests significant developmenttal delay in reading ability or persistent errors. About 3-7% of school-age children have this condition. The purpose of the present study was to validate the diagnostic values of Word/Nonword Reading Test and Letter-Symbol Discrimination Task for the purpose of overcoming the caveats of Basic Learning Skills Test. Methods:Sixty-three reading-disordered patients(mean age 10.48 years old) and sex, age-matched 77 normal children(mean age 10.33 years old) were selected by clinical evaluation and DSM-IV criteria. Reading I and II of Basic Learning Skills Test, Word/Nonword Reading Test, and Letter-Symbol Discrimination Task were carried out to them. Word/Nonword Reading Test:One hundred usual highfrequency words and one hundred meaningless nonwords were presented to the subjects within 1.2 and 2.4 seconds, respectively. Through these results, automatized phonological processing ability and conscious letter-sound matching ability were estimated. Letter-Symbol Discrimination Task:mirror image letters which reading-disordered patients are apt to confuse were used. Reliability, concurrent validity, construct validity, and discriminant validity tests were conducted. Results:Word/Nonword Reading Test:the reliability(alpha) was 0.96, and concurrent validity with Basic Learning Skills test was 0.94. The patients with developmental reading disorders differed significantly from normal children in Word/Nonword Reading Test performances. Through discriminant analysis, 83.0% of original cases were correctly classified by this test. Letter-Symbol Discrimination Task:the reliability(alpha) was 0.86, and concurrent validity with Basic Learning Skills test was 0.86. There were significant differences in scores between the patients and normal children. Factor analysis revealed that this test were composed of saccadic mirror image processing, global accuracy, mirror image processing deficit, static image processing, global vigilance deficit, and inattention-impulsivity factors. By discriminant analysis, 87.3% of the patients and normal children were correctly classified. Conclusion:The patients with developmental reading disorders had deficits in automatized visuallexical route, morpheme-phoneme conversion mechanism, and visual information processing. These deficits were reliably and validly evaluated by Word/Nonword Reading Test and Letter-Symbol Discrimination Task.

  • PDF

The influence of composite resin restoration on the stress distribution of notch shaped noncarious cervical lesion A three dimensional finite element analysis study (복합레진 수복물이 쐐기형 비우식성 치경부 병소의 응력 분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Lee, Chae-Kyung;Park, Jeong-Kil;Kim, Hyeon-Cheol;Woo, Sung-Gwan;Kim, Kwang-Hoon;Son, Kwon;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.69-79
    • /
    • 2007
  • The purpose of this study was to investigate the effects of composite resin restorations on the stress distribution of notch shaped noncarious cervical lesion using three-dimensional (3D) finite element analysis (FEA). Extracted maxillary second premolar was scanned serially with Micro-CT (SkyScan1072 ; SkyScan, Aartselaar, Belgium). The 3D images were processed by 3D-DOCTOR (Able Software Co., Lexington, MA, USA). ANSYS (Swanson Analysis Systems, Inc., Houston, USA) was used to mesh and analyze 3D FE model. Notch shaped cavity was filled with hybrid or flowable resin and each restoration was simulated with adhesive layer thickness ($40{\mu}m$) A static load of 500 N was applied on a point load condition at buccal cusp (loading A) and palatal cusp (loading B). The principal stresses in the lesion apex (internal line angle of cavity) and middle vertical wall were analyzed using ANSYS. The results were as follows 1. Under loading A, compressive stress is created in the unrestored and restored cavity. Under loading B, tensile stress is created. And the peak stress concentration is seen at near mesial corner of the cavity under each load condition. 2. Compared to the unrestored cavity, the principal stresses at the cemeto-enamel junction (CEJ) and internal line angle of the cavity were more reduced in the restored cavity on both load con ditions. 3. In teeth restored with hybrid composite, the principal stresses at the CEJ and internal line angle of the cavity were more reduced than flowable resin.

Conceptual Design of the Three Unit Fixed Partial Denture with Glass Fiber Reinforced Hybrid Composites (Glass fiber 강화 복합레진을 사용한 3본 고정성 국소의치의 개념 설계 연구)

  • Na, Kyoung-Hee;Lee, Kyu-Bok;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.145-155
    • /
    • 2002
  • The results of the present feasibility study are summarized as follows, 1. The three unit bridge of knitted material and UD fibre reinforcement has both the rigidity and the strength against a vertical occlusal load of 75N. 2. Stress concentration at the junctional area between the bridge and the abutments, i.e. between the pontic and the knitted caps was observed. In the case of the bridge with reinforcement straps, it was partly shown that the concentration problem could be improved by simply increasing the fillet size at the area. Further refining in the surface of the junctional area will be needed to ensure a further improvement in the stress distribution. This will require some trade off in the level of the stress and the available space. A parametric study will help to decide the appropriate size of the fillet. 3. Design refinement is a must to improve the stress distribution and realize the most favourable shape in terms of fabrication. The current straight bar with a constant cross section area can be redesigned to a tapered shape. The curve from the dental arch should also be placed on the pontic design. In accordance with design refinement, the resistance of the bridge frame to other load cases should be evaluated. 4. Although not included in the present feasibility study, it is estimated that bridges of the anterior teeth can be made strong enough with the knitted material without further reinforcement using unidirectional materials. In this regard, a feasibility study on design concepts and stress analysis for 3, 4, 5 unit bridge is suggested. 5. Two types of bridge were analysed in terms of fatigue. The safe life design concept, i.e. fatigue design concept, looks reasonable for the bridge where if cracks should form and propagate there is virtually nothing a dentist to do. The bridge must be designed so that no crack will be initiated during the life span. In the case of crowns, however, if constructed with composite resin with knitted materials, it might be possible to repair them, which in general is impossible for crowns of PFM or of metal. Therefore for composite resin crowns, a damage tolerance design concept can be applied and reasonably higher operational stresses can be allowed. In this case, of course, a periodic inspection program should be established in parallel. 6. Parts of future works in terms of structural viewpoint which need to be addressed are summarized as the following: 1) To develop processing technology to accommodate design concepts; 2) More realistic modelling of the bridge and analysis-geometry and loading condition. Thickness variation in the knitted material, taper in the pontic, design for anterior tooth bridge, the effect of combined loads, etc, will need to be included; 3) To develop appropriate design concepts and design goals for the fibre composite FPD aiming at taking the best advantage of knitted materials, including the damage tolerance design concept; 4) To develop testing method and perform test such as static ultimate load test, fatigue test, repair test, etc, as necessary.