• Title/Summary/Keyword: Static Strength Evaluation

Search Result 281, Processing Time 0.026 seconds

Design and Analysis on Composite Structure for Aircraft Certification (항공기 인증을 위한 복합재 구조물 설계/해석)

  • Kim, Sung-Joon;Choi, Ik-Hyeon;Ahn, Seok-Min;Yeom, Chan-Hong
    • Aerospace Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.42-48
    • /
    • 2009
  • There are a number of factors affecting the continued airworthiness of composite structure. Unlike metal structure, damages made in manufacturing processes or maintenance repair procedures need to be considered. The different levels of degradation and damage, which may occur, must be considered for structural substantiation of static strength, stiffness, flutter, and damage tolerance. This can start with an evaluation of environmental effects for the particular composite material. Matrix-dominated composite properties, such as compressive strength, are most sensitive to moisture absorption and temperatures. Static strength substantiation includes the smaller damages that will not be detected in production or maintenance inspection while damage tolerance addresses larger damages that need to be repaired once discovered. In this paper, we intend to list the airworthiness regulations and advisory circular that are deemed closely related to the certification of composite airplanes.

  • PDF

A Study for Evaluation of Hot Mixed Asphalt Mixtures with Tack-Coat Regarding High-Frequency Dynamic Resistance Performance and Bonding Property (택코트 첨가 가열아스팔트 혼합물의 고주파 동적저항 특성 및 접착성능 평가에 대한 연구)

  • Kim, Dowan;Mun, Sungho
    • International Journal of Highway Engineering
    • /
    • v.17 no.3
    • /
    • pp.35-47
    • /
    • 2015
  • PURPOSES : A tack coat has been utilized to increase the bond performance between the surface layer and base course (intermediate course) at various road pavement sites. This is similarly true in other nations. Based on this connection, the objective of the present study is to evaluate the properties of hot mix asphalt (HMA) mixtures with an RSC-4 or BD-Coat and determine the application rate of the tack coat. METHODS : The HMA specimens were manufactured using superpave gyratory compaction. The HMA mixtures were composed of a 5-cm thick surface layer and a 10-cm thick base course. An impact hammer resonance test (IHRT) and a static load shear test were conducted to evaluate the performance of the HMA mixtures with a tack coat. From these tests, the dynamic moduli related to the high-frequency resistance and interlayer shear strength (ISS) of HMA could be obtained. RESULTS : The results of the dynamic moduli of HMA are discussed based on the resonance frequency (RF). To check the accuracy of the IHRT, we conducted a coherence analysis. A direct shear test using the application of a static load test was carried out to evaluate the interlayer shear strength (ISS) of HMA. CONCLUSIONS : The maximum ISS was demonstrated at an RSC-4 application rate of 462 gsm, and the maximum dynamic modulus was demonstrated at an RSC-4 application rate of 306 gsm. By averaging the results of the ISS, the maximum ISS values were obtained when a BD-Coat application rate of 602 gsm was applied.

Static Test and Suggestion of Shear Strength Equation on Shear Studs in Composite Bridge (합성형 교량에서 전단연결재에 대한 정적실험 및 강도식의 제안)

  • Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.43-50
    • /
    • 2018
  • In this study, to investigate the shear connection material for the composite of steel plate and bottom plate, design standards and research cases for shear connectors in various countries around the world were analyzed and shear tests were performed on the Push-out specimens with a shear connection, which transmits the horizontal shear force developed on the contact surface between the steel plate and the concrete slab due to various vertical loads acting on the bridge deck. Through Push-out tests of shear studs, of which FRP bar instead reinforcement is placed, the shear stud evaluation formula of the steel strap bottom plate was suggested. The suggested equation suggested in this study has the safety factor of approximately three times compared to allowable strength of highway bridge design criteria. In addition, compared to existing DIN standards and Viest assessment equation, the results showed similar values(approximately, 5% error).

Evaluation of Structural Behaviour of a Composite CFT Truss Girder Bridge (CFT 트러스 거더 합성형교의 구조거동 평가)

  • Chung, Chul-Hun;Kim, Hye-Ji;Song, Na-Young;Ma, Hyang-Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2A
    • /
    • pp.149-159
    • /
    • 2010
  • This paper presents an experimental study on the structural behavior of composite CFT truss girder bridge with full depth precast panels. The length of span is 20,000 mm. The CFT truss girder is a tubular truss composed of chord members made of concrete-filled and hollow circular tubes. To determine fundamental structural characteristics such as the strength and deformation properties of composite CFT truss girder bridge, static and dynamic tests were conducted. The natural frequencies calculated by the FEM are in good agreement with experimental results obtained from dynamic test. Bracing have only a small effect on the natural frequencies of composite CFT truss girder bridge as indicated by the FEM results. The yield strength and deformation of the composite CFT truss girder bridges were investigated through a static bending test. Besides, the test results showed that uniform distribution of shear connectors can be applicable in composite CFT truss girder bridges.

Strength Evaluation of Bogie by Loading Test (하중시험에 의한 대차의 강도 평가)

  • Yoon Sung-Cheol;Kwon Sung-Tae;Kim Myung-Rong;Lee Kang-Won
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.622-627
    • /
    • 2004
  • This paper describes the result of load test of bogie frame. The purpose of test is to evaluate an safety which bogie frame shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load. Bogie system consist of bogie frame, suspensions, wheel-sets, brake system and transmission system. Among these component, the bogie frame is the most significant component subjected to the vehicle and passenger loads. The evaluation method is used the JIS E 4207 specification throughout the static load test. The test results have been very safety and stable for design load conditions.

  • PDF

Perforated shear connectors

  • Machacek, Josef;Studnicka, Jiri
    • Steel and Composite Structures
    • /
    • v.2 no.1
    • /
    • pp.51-66
    • /
    • 2002
  • Perforated shear connectors currently used in composite steel and concrete structures are described and evaluated. Modifications of the perforated connector suitable for common use injavascript:confirm_mark('abe', '1'); civil and bridge engineering are proposed. The connectors were tested in laboratories of CTU Prague for shear load capacity. Push tests of connectors with 32 mm openings and with 60 mm openings, both in normal and lightweight concrete of different strength characteristics and with different transverse reinforcement, were carried out. The experimental study also dealt with the connector height and parallel arrangement of two connectors and their influence on shear resistance. While extensive tests with static loading were carried out, fatigue tests under repeated loading are still in progress. After statistical evaluation of the experimental results and comparisons with other available data the authors developed reasonable shear resistance formulas for all proposed arrangements.

The Notched Strength and Fracture Criterion in Plain Woven Glass/Epoxy Composites With a Crack (노치부를 가진 Glass/Epoxy 복합재료의 노치강도 평가와 불안정 파괴조건)

  • 김정규;김도식
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.57-67
    • /
    • 1993
  • The fracture behavior of plain woven glass/epoxy composite plates with a crack is investigated under static tensile loading. It is shown in this paper that the characteristic length associated with the point stress criterion depends on the crack length. To predict the not ched tensile strength, the point stress criterion proposed by Whitney and Nuismer are modified. An excellent agreement is found between the experimental results and the analytical prediction of the modified point stress criterion. The condition of unstable crack growth in the presence of a per-existing flaw(machined notch) is examined by means of the maximum stress intensity factor $K_max$ using maximumload P$_max$. The values of $K_max$ evaluated from energy release rate G$_max$(the compliance me thod) indicate a wide difference. Therefore in regard to anisotropy and heterogeneity of the composite materials studied, the modified shape correction factor f(a/W) is obtained. $K_max$evaluated by the compliance method a little or insignificantly depends on the initial crack length a, the specimen thickness B, the crack angle .theta. and the specimen geometry.

  • PDF

Stress Distribution Analysis of Jointed Concrete Pavements (줄눈콘크리트포장의 하중응력분포 해석)

  • Park, Je-Seon;Lee, Joo-Hyung;Kim, Tea-Kyung;Yun, Kyung-Ku
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.363-370
    • /
    • 1998
  • This study focused on the development of an alternative stress estimation procedure to instantly calculate the critical stresses bonded concrete pavement. Closed form analysis is commonly used to analyze pavement structures. This type of analysis assumes linearelastic material properties and static loading conditions. The well-known ILLI-SLAB finite element program was used for the analysis. Bonded concrete overlay analyzed the stress distribution, behavior and load carrying capacity under track load is made evaluation standard of bonded concrete overlay. In the study, the following results were derived ; The properties of strength is that compress and 3-point bending strength of existing pavement is deteriorated with $184kg/cm^2$, $59kg/cm^2$ but compress and splitting tensile strength of overlay is satisfied with $465kg/cm^2$, $45kg/cm^2$. Load transfers is happen at adjacent slab by interlocking under track load. The stress distribution under interior, corner and edge load is described high loading position surrounding then loading position.

  • PDF

Process and Strength Evaluation of Mechanical Press Joining (기계적 프레스 접합의 공정 및 강도 평가)

  • Lee, Sang-Hoon;Kim, Ho-Kyung
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.1-6
    • /
    • 2011
  • New methods for joining sheet of metal are being sought. One of the most promising methods is MPJ (mechanical press joining). It has been used in thin metal work because of its simple process and relative advantages over other methods, as it requires no fasteners such as bolts or rivets, consumes less energy than welding, and produces less ecological problems than adhesive methods. In this study, the joining process and static behavior of single overlap joints has been investigated. During fixed die type joining process for SPCC plates, the optimal applied punching force was found. The maximum tensile-shear strength of the specimen produced at the optimal punching force was 1.75 kN. The FEM analysis result on the tensile-shear specimen showed the maximum von-Mises stress of 373 MPa under the applied load of 1.7 kN, which is very close to the maximum tensile strength of the SPCC sheet(= 382 MPa). This suggests that the FEM analysis is capable of predicting the maximum tensile load of the joint.

Bending strength assessment of Larix logs by nondestructive evaluation techniques (비파괴 시험방법을 이용한 낙엽송재 원목의 휨강도 특성 평가)

  • 박준철;홍순일
    • Journal of Korea Foresty Energy
    • /
    • v.22 no.2
    • /
    • pp.60-68
    • /
    • 2003
  • In forest products industry, a variety of nondestructive evaluation techniques are now being used to assess the mechanical properties of structural lumber. Ultrasonic and longitudinal vibration technique are frequently used to assess the modulus of elasticity(MOE) of lumber. The objective of this research was to evaluate the MOE and modulus of rupture(MOR) of small-diameter of Larix log(Larix kaempferi Carr.), using these techniques. In this study, 50 small-diameter logs were nondestructiveively evaluated. The dynamic modulus of elasticity(Eu) of the logs was first evaluated, using an ultrasonic method. After ultrasonic tests, the logs were measured using a longitudinal vibration technique(Ev). Static bending test was then performed on the logs to obtain the static modulus of elasticity(Es) and modulus of rupture of these logs. In general, the dynamic MOE (Ev) of logs was closely co..elated with the stati, MOE for log. Based on the results of these experiments, it can be concluded that small-diameter Larix logs can be successfully evaluated by Ultrasonic and longitudinal vibration technique. The experimental results indicated that the ultrasonic technique is effective to the log, which contains many knots. The longitudinal vibration technique is effective to the log, in which many cracks are included.

  • PDF