• Title/Summary/Keyword: Static Sensitivity

Search Result 268, Processing Time 0.022 seconds

Flying-Wing Type UAV Design Optimization for Flight Stability Enhancement (전익기형 무인기의 비행 안정성 향상을 위한 형상 최적화 연구)

  • Seong, Dong-gyu;Juliawan, Nadhie;Tyan, Maxim;Kim, Sanho;Lee, Jae-woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.10
    • /
    • pp.809-819
    • /
    • 2020
  • In this study, the twist angle and wing planform shapes were selected as design variables and optimized to secure the stability of the flying-wing type UAV. Flying-wing aircraft has no separated fuselage and tails, which has advantages in aerodynamic characteristics and stealth performance, but it is difficult to secure the flight stability. In this paper, the sweep back angle and twist angle were optimized to obtain the lateral stability, the static margin and wing planform shapes were optimized to improve the longitudinal stability of the flying-wing, then effect of the twist angle was confirmed by comparing the stability of the shape with the winglet and the shape with the twist angle. In the optimization formulation, focusing on improving stability, constraints were established, objective functions and design variables were set, then design variable sensitivity analysis was performed using the Sobol method. AVL was used for aerodynamic analysis and stability analysis, and SQP was used for optimization. The CFD analysis of the optimized shape and the simulation of the dynamic stability proved that the twist angle can be applied to the improvement of the lateral stability as well as the stealth performance in the flying-wing instead of the winglet.

An Criterion to Minimize FE Mesh-Dependency in Concrete Plate under Impact Loading (충격하중을 받는 판형콘크리트 구조물의 요소의존성 최소화 기준식)

  • Kwak, Hyo-Gyoung;Gang, Han-Gul;Park, Lee-Ju
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.3
    • /
    • pp.147-154
    • /
    • 2014
  • In the context of an increasing need for safety in concrete structures under blast and impact loading condition, the behavior of concrete under high strain rate condition has been an important issue. Since concrete subjected to impact loading associated with high strain rate shows quite different material behavior from that in the static state, several material models are proposed and used to describe the high strain rate behavior under blast and impact loading. In the process of modelling high strain rate conditions with these material models, mesh dependency in the used finite element(FE) is the key problem because simulation results under high strain-rate condition are quite sensitive to applied FE mesh size. This paper introduces an criterion which can minimize the mesh-dependency of simulation results on the basis of the fracture energy concept, and HJC(Holmquist Johnson Cook) model is examined to trace sensitivity to the used FE mesh size. To coincide with the purpose of the perforation simulation with a concrete plate under a projectile(bullet), the residual velocities of projectile after perforation are compared. The analytical results show that the variation of residual velocity with the used FE mesh size is quite reduced and accuracy of simulation results are improved by applying a unique failure strain value determined according to the proposed criterion.

Smart Camera Technology to Support High Speed Video Processing in Vehicular Network (차량 네트워크에서 고속 영상처리 기반 스마트 카메라 기술)

  • Son, Sanghyun;Kim, Taewook;Jeon, Yongsu;Baek, Yunju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.1
    • /
    • pp.152-164
    • /
    • 2015
  • A rapid development of semiconductors, sensors and mobile network technologies has enable that the embedded device includes high sensitivity sensors, wireless communication modules and a video processing module for vehicular environment, and many researchers have been actively studying the smart car technology combined on the high performance embedded devices. The vehicle is increased as the development of society, and the risk of accidents is increasing gradually. Thus, the advanced driver assistance system providing the vehicular status and the surrounding environment of the vehicle to the driver using various sensor data is actively studied. In this paper, we design and implement the smart vehicular camera device providing the V2X communication and gathering environment information. And we studied the method to create the metadata from a received video data and sensor data using video analysis algorithm. In addition, we invent S-ROI, D-ROI methods that set a region of interest in a video frame to improve calculation performance. We performed the performance evaluation for two ROI methods. As the result, we confirmed the video processing speed that S-ROI is 3.0 times and D-ROI is 4.8 times better than a full frame analysis.

The study of a practical modeling method for the analysis of dynamic behavior by the mockup test of prestressed concrete girder (PSC I형 거더 실물 모형체 실험을 통한 동적거동특성 분석의 실용적 모델링 기법 연구)

  • Kim, Hyung-Kyu;Jang, Il-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.148-156
    • /
    • 2018
  • The integrity assessment of the bridge behavior is generalized by field data of a static load-deformation curve and dynamic properties such as impact factors and natural frequencies. Evaluating it with numerical analysis is a reasonable method. The results of the mockup test and the numerical analysis are corresponded with each other since the behavior of service load proceeds in elastic region. In case of the dynamic behavior of structure, especially for the analysis of vibration, the result of the mockup test differs from the result of numerical analysis a little due to the geometric shape and non-homogeneous materials. In order to converge on these tolerances, this study suggested several numerical models, analyzed the sensitivity and finally offered a practical modeling method for the estimation of bridge on the basis of the result of mockup test. Based on the model substituted concrete section for strands section, the natural frequency of the model composed with axial stiffness of strands or the model applied the modified modulus of elasticity was closest with the result of the mockup test.

Planar microchip-based lactate biosensor (평면 소자형 락테이트 바이오센서)

  • Ha, Jeonghan;Huh, Hwang;Kang, Tae Young;Lee, Yong Seok;Yoon, Soon Ho;Shin, Jungwon;Nam, Hakhyun;Cha, Geun Sig
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.482-489
    • /
    • 2006
  • Two electrode-based lactate biosensor was prepared by immobilizing lactate oxidase (LOD) obtained from pediococcus species in a poly(vinyl alcohol). Hydrogen peroxide ($H_2O_2$) produced by the reaction of lactate and LOD was detected on the Pt-black that was electrochemically deposited on the Au electrode. Sensors fabricated with Pt-black deposited Au electrode provided a high current of $H_2O_2$ oxidation at a substantially lowered applied potential (+300 mV vs. Ag/AgCl), resulting in reduced interferences from easily oxidizable species such as ascorbic acid, acetaminophen, and uric acid. An outer membrane is formulated by adjusting water uptake of hydrophilic polyurethane (HPU). The sensor performance was evaluated in vitro with both flow-through arrangement and static mode. The sensor showed a linear range from 0.1 mM to about 9.0 mM in 0.05 M phosphate buffer (pH 7.6) containing 0.05 M NaCl. Storing the sensors prepared in this work at $4^{\circ}C$ buffer solution while not in use, they provided same electrochemical performance for more than 25 days.

Establishment of Marine Ecotoxicological Standard Method for Larval Fish Survival Test (어류 자어의 사망률을 이용한 해양생태독성시험 방법에 관한 연구)

  • Park, Gyung-Soo;Kang, Ju-Chan;Yoon, Sung-Jin;Lee, Seung-Min;Hwang, Un-Ki
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.2
    • /
    • pp.140-146
    • /
    • 2008
  • Marine ecotoxicological standard method using fish larvae was established with the standard test species of Oryzias latipes(Japanese Medaka) and Paralichthys olivaceus(flounder) and with the 7 day $LC_{50}$ as endpoint. Test method referred to the USEPA(1994) with the replacement of test species found in the Korean water. Standard test species were selected in terms of the species supply and ecological importance in Korean waters. Japanese medaka can be reared with small tanks in the lab and has wide tolerance on salinity, and flounder eggs can be easily obtained from commercial fish hatcheries. General conditions for larval fish toxicity test are as follows. The possible salinity ranges for toxicity test were $0{\sim}35\;psu$ for medaka and >20 psu for flounder. Test type was designated as static non-renewal test if the dissolved oxygen in the test chamber does not fall below 4.0 mg/L. Ages of test species were selected as 7 days after hatched for medaka(about 5 mm TL) and 25 days for flounder(about 10 mm TL) because of the low natural mortality after these periods. Test can be accepted when the survival rates are over 80% in control. Also, species sensitivity on standard reference materials(copper, cadmium or zinc) must be provided with the toxicity test results.

Studies on the Improvement of the Fishing Efficiency of Purse Seine in the Sea Area of Cheju Island -The Changes of Seine Volume and Tension in the Purseline During Pursing- (제주도 주변해역 선망의 어획성능 향상에 관한 연구 -짐줄 체결 중 선망의 용적과 짐줄의 장력 변화 -)

  • 김석종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • A simple experimental method was used in an attempt to realize the elevation of the fishing ability of purse seine in the sea area of Cheju Island, the changes of seine volume and tension in the purseline during pursing. Experiments carried out on the six types simplified reduced model seines which were made of knotless nettings. The nettings were woven in different leg length 4.3, 5.0, 5.5, 6.0, 6.6 and 7.7mm of polyester 28 tex two threads two-ply twine, and each of the seines were named I, II, III, IV, V and Ⅵ seine. Dimension of seine models were 450cm for corkline and 85cmfor seine depth, each seines rigged up 160g of float for a floatline and 50g (underwater weight) of lead for a leadline. These model purse seines were made of the scale of 1/200 of its full scale, a 120 ton in the near sea of Cheju Island. Designing and testing for the model purse seines were based on the Tauti's law. Experiments were measured in the observation channel of a flume tank at the static conditions set up shooting and pursing equipments. Motion of purse seine during purse line was recorded by the two sets video camera for VTR which were placed in top and front of the model seine. The reading coordinate of seine volume carried out by the video digitization system, disk data for the purseline tension. An analysis were performed on the changes seine volume and tension in the purseline during pursing. The results obtained were as follows: 1. The seine volume during pursing was largest for Ⅵ seine with smallest d/l followed by V, IV, III, II and I seines, and tension in the purseline was small. 2. Seine volume during pursing can be expressed by the following equation; CVt=l-EXP[{2.79 (d/l)+0.35}t-33.37 (d/l) + 0.57] Where CVt is volume ratio, d is twine diameter, l is leg length and t is pursing time (sec). 3. Tension in the purse line during pursing can be expressed by the following equation; T= 1- EXP {0.57t + 13.36 (d/l)+2.97} Where T is tension (kg) in the purseline during pursing.

  • PDF

Performance Evaluation of a Pinhole Collimator According to the Aperture Diameter (핀홀 콜리메이터 초점의 직경 크기 별 성능비교 및 평가)

  • Lee, Kwang Hun;An, Byung Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.104-109
    • /
    • 2014
  • Purpose: Conventional pinhole scintigraphy offers a high resolution and generally use for thyroid scan or bone scintigraphy. the aim of this study is to evaluate performance of each aperture according to the diameter size. Materials and Methods: In this study 2 mm, 4 mm, 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture, we acquired projection image by using SPECT for evaluating FWHM, resolution test and static image for evaluating thyroid phantom test. Results: As a result of FWHM showed 2.2 mm FWHM, 3.2 mm FWHM, 5.4 mm FWHM, 7.5 mm FWHM per each aperture in the resolution test. SNR, uniformity, contrast were acquired result from thyroid phantom test comparing general image and delayed image. as a result of SNR showed 6.55, 8.47, 6.2, 5.23 in case of general image and 5.25, 5.01, 5.38, 5.82 in case of delayed image per each aperture. as a result of uniformity showed 0.152, 0.118, 0.161, 0.19 in case of general image and 0.19, 0.199, 0.185, 0.171 in case of delayed image per each aperture. as a result of contrast showed 1.31, 1.19, 1.15, 1.01 in case of general image and 1.09, 1.08, 1.04, 1 in case of delayed image per each aperture. Conclusion: Resolution and sensitivity were heavily influenced by aperture size. and also we found advantage of delayed image as a result of thyroid phantom test.

  • PDF