• Title/Summary/Keyword: Static Pressure Error

Search Result 41, Processing Time 0.022 seconds

Study on Static Pressure Error Model for Pressure Altitude Correction (기압 고도의 정밀도 향상을 위한 정압 오차 모델에 관한 연구)

  • Jung, Suk-Young;Ahn, Chang-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.47-56
    • /
    • 2005
  • In GPS/INS/barometer navigation system for UAV, vertical channel damping loop was introduced to suppress divergence of the vertical axis error of INS, which could be reduced to the level of accuracy of pressure altitude measured by a pitot-static tube. Because static pressure measured by the pitot-static tube depends on the speed and attitude of the vehicle, static pressure error models, based on aerodynamic data from wind tunnel test, CFD analysis, and flight test, were applied to reduce the error of pressure altitude. Through flight tests and sensitivity analyses, the error model using the ratio of differential pressure and static pressure turned out to be superior to the model using only differential pressure, especially in case of high altitude flight. Both models were proposed to compensate the effect of vehicle speed change and used differential and static pressure which could be obtained directly from the output of pressure transducer.

Evaluation of the Turbulence Models on the Aerodynamic Performance of Three-Dimensional Small-Size Axial Fan (3차원 소형축류홴의 공력특성에 대한 난류모델평가)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.13-20
    • /
    • 2014
  • The steady-state, incompressible and three-dimensional numerical analysis was carried out to evaluate turbulent models on the aerodynamic performance of a small-size axial fan(SSAF). The prediction performance on the static pressure of all turbulent models is going downhill at the high static pressure and low flowrate region, but has improved at the axial flow region. In consequence, all turbulent models predict the static pressure coefficient with an error performance less than about 4% after the region of the flowrate coefficient of about 0.14. Especially, the turbulent model of SST $k-{\omega}$ shows the best prediction performance equivalent to an error performance less than about 2% on the static pressure.

Study on Flight Test Practice of the Small Civil Airplane Development for Pitot-Static System's Error Identification (소형 항공기 개발 동정압계통 오차 확인 비행시험 사례)

  • Kim, Chanjo;Seo, Jihan;Lee, Wonjoong
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.3
    • /
    • pp.33-38
    • /
    • 2013
  • The air data measured from the static pressure, the dynamic pressure and etc. of an airplane is used for calculation of many flight parameters(altitude and airspeed and so on) and these values applied to flight safety and navigation flight. The pitot-static system of the development airplane is calibrated by finding of pitot-static system's error using tower fly-by, trailing cone method and etc. This paper is describing for the introduction of the trailing cone method and major items for test planning, preparation, operation and results for air data calibration flight test performed, considering efficiency and safety during KC-100 development project.

Effect of Spool-Sleeve Geometry on Static Pressure Characteristics of Servo Valves (서보밸브 스풀-슬리브 형상공차가 압력 정특성에 미치는 영향 연구)

  • Kim, Sung Dong;Son, Sung Hoe;Ham, Young Bog
    • Journal of Drive and Control
    • /
    • v.13 no.1
    • /
    • pp.34-42
    • /
    • 2016
  • This study studied how the clearance, overlap and mismatch errors of spool-sleeve affect the static pressure characteristics of a servo valve. A computer simulation model was established as a direct acting servo valve and a series of simulations was conducted for various values of clearance, overlap and mismatch errors. Pressure gain decreased as the clearance increased. The overlap also affects the pressure gain and was similar to the effect of clearance. Asymmetry of the pressure plot got worse and worse as the mismatch error increased.

An Experimental Study on the Flow Pattern in the Vicinity of Pressure Measuring Hole of the Viscoelasitc Fluids (점탄성유체의 압력측정용 벽공부근의 유동모양에 관한 실험적 연구)

  • 김춘식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.23-31
    • /
    • 1980
  • The fluid static pressure has been generally measured by means of a small hole leading to a measuring instrument. In case of viscoelastic fluids, however, it has been shown experimentally that a systematic error exists in measuring the static pressure by means of the small hole becuase viscoelasitc fluids have many properties that can not be observed in Newtonian fluids. In this paper, in order to examine the mechanism of the errors in measuring the static pressure of viscoelasitc fluids, flow patterns in the vicinity of static pressure measuring hole were photographically taken and observed graphically. The experiments to take photographs of flow patterns were performed by a parallel plate channel with the steady two-dimensional shear flow of viscoelastic fluids. Results of the experiment are classified as following three regions; (1) Arched symmetrical flow pattern region. (2) Asymmetrical flow pattern region. (3) Rectilinear symmetricl flow pattern region.

  • PDF

The Usefulness of Clinical Balance Tests in Elderly : Correlation of Balance Evaluation using by Forceplate (노인에서 임상적 균형평가 지수들의 유용성 : 힘판을 이용한 균형평가와의 상관관계)

  • Woo, Young-Keun;Hwang, Su-Jin;Lee, Woo-Hyung
    • PNF and Movement
    • /
    • v.8 no.1
    • /
    • pp.67-77
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the usefulness of clinical balance tests through the correlation of balance evaluation using by forceplate in elderly. Methods : Thirty nine healthy elderly subjects (14 males, 25 females) participated in the study. The subjects were evaluated with clinical balance tests [(Berg balance scale (BBS), Functional reach test (FRT), Tinetti's performance oriented mobility assessment (POMA), and one leg standing (OLS)]. Static balance evaluation was assessed by using forceplate. Center of pressure (COP) parameters were obtained using it as total path distance, total sway area, X mean frequency and Y mean frequency for 20 seconds in the following conditions: (1) comfortable standing with eyes opened and closed, (2) uncomfortable standing with eyes opened and closed. After static balance evaluation tested, dynamic balance evaluation was assessed. COP parameters were error distance and area during sine curve trace. COP parameters were movement time, error distance, and maintained time in the circle during COP movement task. Results : Clinical balance tests showed statistically significant correlation between static and dynamic balance evaluations. Among the clinical balance tests, the BBS, POMA, and OLS showed significant correlation with to assess the balance ability of elderly in clinical setting both evaluations. Conclusion : Clinical balance tests can be recommended in clinical setting because of low costs and simplicity.

  • PDF

Evaluation of Muscle Activity and Foot Pressure during Gait, and Isokinetic Strength and Balance in Persons with Functional Ankle Instability (기능적 발목관절 불안정성의 등속성 근력과 균형 및 보행 중에 근활성도와 발바닥압의 평가)

  • Lee, Sun-Ah;Kim, Ah-Ram;Yoo, Kyung-Tae;Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.3
    • /
    • pp.27-37
    • /
    • 2018
  • PURPOSE: The purpose of this study was to investigate and evaluate muscle activity and foot pressure during gait, and isokinetic strength and balance in persons with functional ankle instability (FAI). METHODS: Nine healthy subjects (CON, n=9) without FAI and 11 patients (FAI, n=11) with FAI participated in the study after having been screened with an ankle instability instrument and a balance error scoring system. In addition, FAI was classified as non-involved (FAI-N) or involved (FAI-I), and CON was classified as dominant or non-dominant. All subjects were evaluated for isokinetic strength (plantar flexion, dorsiflexion, inversion and eversion of $30^{\circ}/sec$ and $60^{\circ}/sec$), balance (static and dynamic), muscle activity (tibialis anterior, peroneus longus and gastrocnemius) and foot pressure (static and dynamic) during gait. RESULTS: Results showed that plantar flexion (p<.05), dorsiflexion (p<.05), inversion (p<.01) and eversion (p<.00) of $60^{\circ}/sec$ were significantly decreased in FAI-I compared to those in FAI-N and CON. C 90 of static balance with eyes open (p<.01) and closed (p<.00) were significantly increased in FAI compared to those in CON. Forward position of dynamic balance (p<.01) was significantly decreased in FAI compared to that in CON. Gastrocnemius and peroneus longus of dynamic muscle activity (p<.01), left and right weight distribution of static foot pressure (p<.00) and pressure distribution of dynamic foot pressure (p<.00) were significantly decreased in FAI-I compared to those in FAI-N. CONCLUSION: We demonstrated that ankle strength, balance, muscle activity and foot pressure were significantly correlated with FAI.

An Experimental Study on Porous Air Bearing Stiffness Characteristics (다공질 공기 베어링의 강성 특성에 관한 실험 연구)

  • Jung, Soon-Chul;Lee, Seong-Hyuk;Lee, Jae-Eung;Ji, Hong-Kyu;Lee, Dong-Jin;Ryu, Je-Hyoung;Choi, Hyoung-Gil;Kim, Hyuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.75-78
    • /
    • 2005
  • In this paper, an experimental study on porous air bearing stiffness for ultra precision positioning system was performed. In general manufacturer provide bearing stiffness under specific air pressure, but the air pressure used in the field is different. Therefore it is necessary to know the stiffness of air bearing under the pressure used in the field. In order to know that, experimental device which can realize actual operating conditions was made. Using this device, static and dynamic stiffness of air bearing can be obtained. As a result, displacement error occurred around 1 $\mu$m at recommended load.

  • PDF

Inter-comparison between ultrasonic interferometer manometer and medium vacuum standards by static expansion method (초음파간섭 수은주압력계와 정적법 중진공 국가표준기 상호비교)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.103-109
    • /
    • 2005
  • A new medium vacuum primary standard using the static expansion method was developed in KRISS. In order to evaluate the performance of the equipment, we compared the medium vacuum standard with an ultrasonic interferometer manometer using two capacitance diaphragm gauges, the measuring ranges of which were 133 Pa and 1,333 Pa respectively. The result, Error normalized values, showed that the two standards are coincident each other within the range of combined uncertainty at calibrated pressure of $3pa\;\sim\;100pa$.

The Development of Turbo-Fan Blade for KTX (KTX용 터보팬 블레이드 개발)

  • Jang, Young-Min;Kwon, O-Woon;Kim, Sung-Joon
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.41-45
    • /
    • 2009
  • The new cooling fan for various parts & equipments of KTX is developed and evaluated to improve fan performance and durability. The characteristic curve of the developed fan is obtained according to KSB 6311 of performance test regulation. 70 degree of the installation angle of blade makes the fan to produce a maximum flow rate. This angle is found out through trial-error and is confirmed through the verification test. In order to improve the blade strength, the blade is produced by a draw forming. The adoption of AL50 reduces a fan weight by 6 kg. The new blade makes a static pressure 170 (mmAq), a discharge rate $140(m^3/min)$, a rotational speed 2886 (rpm) at the power 10 kw. which results 54% of the static pressure improvement relative to the original blade.

  • PDF