• 제목/요약/키워드: Static Measurement

검색결과 710건 처리시간 0.026초

정적 및 동적 range 검출에 의한 원료 처리 자동화용 vision 시스템 (A vision system for autonomous material handling by static and dynamic range finding)

  • 안현식;최진태;이관희;신기태;하영호
    • 전자공학회논문지S
    • /
    • 제34S권10호
    • /
    • pp.59-70
    • /
    • 1997
  • Until now, considerable progress has been made in the application of range finding techanique performing direct 3-D measurement from the object. However, ther are few use of the method in the area of the application of material handing. We present a range finding vision system consisting of static and dynamic range finders to automate a reclaimer used for material handling. A static range finder detects range data of the front part of the piles of material, and a height map is obtained from the proposed image processing algorithm. The height map is used to calculate the optimal job path as features for required information for material handling function. A dynamic range finder attached on the side of the arm of the reclaimer detects the change of the local properties of the material with the handling function, which is used for avoiding collision and detecting the ending point for changing direction. the developed vision systm was applied to a 1/20 simulator and the results of test show that it is appropriate to use for automating the material handling.

  • PDF

한방 피부 진액 변증론 연구 (study on pattern identification about fluid-humor of skin in Oriental Medicine)

  • 김경신;조가영;김덕희;김병수
    • 혜화의학회지
    • /
    • 제19권2호
    • /
    • pp.35-42
    • /
    • 2011
  • The purpose of this study is to evaluate the difference about pathogenesis of skin type. the theory that explains each individual react to certain stress is generally accepted in traditional oriental medicine. The aim of this experiment is to find out relationship between the effect of facial condition and the vital conditions of traditional Oriental medicine. We recognized that pattern identification of fluid-humor could be divided into 4 different groups. The reason is that the fluid-humor could be interpreted as Qi & Blood, furthermore Qi & Blood were categorized into deficiency and excess groups. Korean female volunteers in good health participated in this experiment. Three doctors of Oriental medicine classified them into 4 groups based on qi-blood and deficiency-excess concept(qi-deficiency; qi-excess:qi-stagnation; blood-deficiency; blood-excess:static-blood). Volunteers were assessed with non-invasive skin measuring devices. And we analyzed the correlation of skin physiological parameters with vital conditions; moisture, sebum and elasticity. Measurement moisture and sebum of facial skin tended to deacease only in static blood group.

접촉각 측정과 AFM/LFM을 이용한 불화 유기박막의 특성 평가 (Characterization of Fluorocarbon Thin Films by Contact Angle Measurements and AFM/LFM)

  • 김준성;차남구;이강국;박진구;신형재
    • 마이크로전자및패키징학회지
    • /
    • 제7권1호
    • /
    • pp.35-40
    • /
    • 2000
  • Teflon-like fluorocarbon thin film was deposited on various substrates by vapor deposition using PFDA (perfluorodecanoic acid). The fluorocarbon films were characterized by static/dynamic contact angle analysis, VASE (Variable-angle Spectroscopic Ellipsometry) and AFM/LFM (Atomic/Lateral Force Microscopy). Based on Lewis Acid/Base theory, the surface energy ($S_{E}$) of the films was calculated by the static contact angle measurement. The work of adhesion (WA) between de-ionized water and substrates was calculated by using the static contact data. The fluorocarbon films showed very similar values of the surface energy and work of adhesion to Teflon. All films showed larger hysteresis than that of Teflon. The roughness and relative friction force of films were measured by AFM and LFM. Even though the small reduction of surface roughness was found on film on $SiO_2$surface, the large reduction of relative friction farce was observed on all films. Especially the relative friction force on TEOS was decreased a quarter after film deposition. LFM images showed the formation of "strand-like"spheres on films that might be the reason far the large contact angle hysteresis.

  • PDF

Phase Locked Loop Sub-Circuits for 24 GHz Signal Generation in 0.5μm SiGe HBT technology

  • Choi, Woo-Yeol;Kwon, Young-Woo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권4호
    • /
    • pp.281-286
    • /
    • 2007
  • In this paper, sub-circuits for 24 GHz phase locked 100ps(PLLs) using $0.5{\mu}m$ SiGe HBT are presented. They are 24 Ghz voltage controlled oscillator(VCO), 24 GHz to 12 GHz regenerative frequency divider(RFD) and 12 GHz to 1.5 GHz static frequency divider. $0.5{\mu}m$ SiGe HBT technology, which offers transistors with 90 GHz fMAX and 3 aluminum metal layers, is employed. The 24 GHz VCO employed series feedback topology for high frequency operation and showed -1.8 to -3.8 dBm output power within tuning range from 23.2 GHz to 26 GHz. The 24 GHz to 12 GHz RFD, based on Gilbert cell mixer, showed 1.2 GHz bandwidth around 24 GHz under 2 dBm input and consumes 44 mA from 3 V power supply including I/O buffers for measurement. ECL based static divider operated up to 12.5 GHz while generating divide by 8 output frequency. The static divider drains 22 mA from 3 V power supply.

초등학교 5학년 어린이의 족부 건강에 대한 조사 연구 (The survey on foot health of a primary school child)

  • 임호용;임진택
    • 대한물리치료과학회지
    • /
    • 제12권3호
    • /
    • pp.35-45
    • /
    • 2005
  • The purpose of this study was to measure the static foot pressure distribution of children between forefoot and rearfoot, and the percentage of static pressure were measured from 1256 normal children in a primary school by the TPScan(Triple Pod Scan) systemCommercial system). The measurement were performed while standing with their comfortable state using the TPScan system. The static pressure distribution between forefoot and rearfoot was analyzed by paired t-test. The results were as follows: 1. The Pes cavus and Pes planus of students was 4.936%. 2. The Pes cavus were 42 children(3.343%) and Pes planus was 20 children(1.592%). 3. The Pes planus were seen in 42 of 1256 children with Grade I in 11 feet (26.2%), Grade II in 24(57.1%), Grade III in 6(57.1%), Grade IV in zero. 4. Pes planus and Pes cavus were significantly difference in foot pressure between forefoot and rearfoot(P<0.05). The future study needs detailed research and comparison with various variance between theses before and after correction.

  • PDF

초내식성 스테인레스강의 금속이온용출특성 및 세포적합성 (Metal Ion Release Behaviour and Cytotoxicity of a Super Stainless Steel)

  • 김철생;박진수;허억;강곤
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.11-18
    • /
    • 1996
  • The toxic metal ion release behaviour and the cytotoxicity of a super stainless steel (S.S.S, 22cr-20Ni -6Mo-0.25N) were investigated The measurement of the amount of static and wear- induced trace metal ion released from the steels was conducted in Hank's balanced salt solution using an electrothermal atomic absdrption spectrometry equiped with Uaphite furnace. And the in vitro cytotoxicity of the materials was assesed in cell culture. The static dissolution rates of Fe and Cr ions from the S.S.S were significantly lower than those of 316L SS. However, the Ni ion release from the S.S.S during the first 4 weeks was yester than that from 316L 55 by 15-45%. Also, the wear-in- duces dissolution rates from the steels were not correlated either with their elemental composition rates or with the static metal ion release rates. The S.S.S did not deteriorate the osteoblasts viability. And no toxic response was observed from the macrophages cultured for 7 days in RFMI 1640 medium immersed with the S.S.S specimens.

  • PDF

주유동의 맥동과 엇갈린 2열 분사홀로부터의 막냉각 : 분사비의 영향 (Bulk Flow Pulsations and Film Cooling from Two Rows of Staggered Holes : Effect of Blowing Ratios)

  • 손동기;이준식
    • 대한기계학회논문집B
    • /
    • 제22권9호
    • /
    • pp.1195-1207
    • /
    • 1998
  • Periodic pulsations in the static pressure near turbine surfaces as blade rows move relative to each other is one of the important sources of turbine unsteadiness. The present experiment aims to investigate the effect of the static pressure pulsations on the interaction of film coolant flows from two rows of staggered holes with mainstream and its effect on film cooling heat transfer. Potential flow pulsations are generated by the rotating shutter mechanism installed downstream of the test section, The free-stream Strouhal number based on the boundary layer thickness is in the range of 0.033 - 0.33, and the amplitude of about 10-20%. Measured are time-averaged and phase-averaged velocity variations, pressure variations and temperature distributions of the flow field. Experimental conditions are identified by boundary layer measurements. Injectant behavior is characterized by the measurements of unsteady pressure in the plenum chamber and free-stream static pressure. The film cooling effectiveness is evaluated from the insulated wall temperature measurement. It has been found that bulk flow pulsation provides very large diffusion of the injectants and the effectiveness is significantly reduced by the flow pulsations.

Performance Improvement of a Floating Solution Using a Recursive Filter

  • Cho, Sung Lyong;Lee, Sang Jeong;Park, Chansik
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제3권3호
    • /
    • pp.117-122
    • /
    • 2014
  • In CDGPS, ambiguity resolution is determined by the performance of a floating solution, and thus, the performance needs to be improved. In the case of precise positioning at a stationary position, the batch method using multiple measurements is used for the accuracy improvement of a position. The position accuracy performance of a floating solution is outstanding, but it has a problem of high computation cost because all measurements are used. In this study, to improve the floating solution performance of the initial static user in CDGPS, a floating solution method using a recursive filter was implemented. A recursive filter estimates the position solution of the current epoch using the position solution of up to the previous epoch and the pseudorange measurement of the current epoch. The computation cost of the floating solution method using a recursive filter was found to be similar to that of the epoch-by-epoch method. Also, based on actual GPS signals, the floating solution performance was found to be similar to that of the batch method. The floating solution using a recursive filter could significantly improve the performance of the prompt initial position and ambiguity resolution of the initial static user.

테이핑과 신장운동이 슬관절 굴곡근과 신전근의 근력 및 근지구력에 미치는 영향 (The Effect of Taping and Stretching Exercise on Muscle Strength and Endurance of Knee Flexors and Extensors)

  • 이호재;현상욱;서현규
    • 대한정형도수물리치료학회지
    • /
    • 제15권2호
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose : to investigate change of isokinetic muscle strength and isokinetic muscle endurance of quadriceps femoris and hamstring after application of taping and static stretching. Methods : For this study, 14 male members of college soccer team participated in this research. Participants were divided into two groups: seven was assigned to a taping group(n=7) and the others were assigned to a static stretching exercise group(n=7). Main outcome was measured by using biodex. The isokinetic muscle strength test was processed at the speed of the $60^{\circ}$/sec five times, and isokinetic muscle endurance was processed at the speed of $180^{\circ}$/sec ten times. Results : From the outcomes of the measurement, the results show that there is a more significant difference in the taping group than in a static stretching exercise group. Conclusion : These results will be utilized for the preliminaries in the future.

  • PDF

균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성 (Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields)

  • 김태기;김승민;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.