• Title/Summary/Keyword: State room design

Search Result 90, Processing Time 0.03 seconds

Actual state Analysis for Residential space of Elderly Nursing Facility (노인요양시설의 거주공간에 대한 실태조사 분석)

  • Jang, Hye-Won;Kim, Dae-Hee;Hwang, Eun-Kyuong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.166-170
    • /
    • 2008
  • The elder population is growing rapidly in Korea nowadays. Therefore, a demand for adaptable installation standard of residential space for the elderly is increasing with growth of the elder population. This study analyzed actual state by interviewing manager, surveying actual measurement and using draft of Elderly nursing facility which is for senile patients. As a result of the survey for size and facilities, facilities for elderly safety, accommodation per a person and room size per a person are below to standard. Therefore, establishing adaptable design standard is needed which is to make safe and fresh living environment for the elderly.

  • PDF

A Study on the Proscenium Type Stage Space Composition for Musical Performance (뮤지컬 공연을 위한 프로시니엄 형식의 무대공간 구성에 대한 연구)

  • John, Yong-Seok
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.5
    • /
    • pp.42-54
    • /
    • 2016
  • The purpose of this study is to provide a reference for stage planning by analyzing current state of major theaters' stage space and understanding feedback from directors belonged to theaters. Each room in total 18 theaters' stage facilities was measured and their usage and requirements were analyzed on the spot. In addition, each director provided their experiential knowledge about appropriate stage composition for musical performance. The findings are as follow: under stage machinery is not needed for musical. Tour teams prefer to use their own show-deck for set conversion. On the other hand, over stage flying system needs to be able to deal with dense, fast, and accurate scene change. The size and location of the motor room needs to be carefully considered. The number of set battens is directly linked up with the size of the motor room, which should be located lower than the gridiron. As stage sets get bigger and complicated, the number of works at the gridiron is also increasing. The grating floor has to have enough strength coping with machines lifting heavy sets. Most sound control for musical performance is being done at F.O.H. these days rather that in the sound control room. It should equip enough work area and related infra especially for tour teams. 1st gallery needs to have enough effective width, power infra for lighting fixture, and strong guardrail. Lastly, the whole process of parking-unloading-transporting equipments and sets from loading dock to stage and vice versa needs to be efficient, and this has to be carefully considered from early stage of planning.

The Indoor Thermal and Air Environment during Winter in One-room Type Multi-family Houses Occupied by University Students (대학생 거주 원룸형 다가구주택의 겨울철 실내열공기환경 실태)

  • Choi, Yoon-Jung;Kim, Wn-Hak
    • Korean Journal of Human Ecology
    • /
    • v.19 no.4
    • /
    • pp.745-760
    • /
    • 2010
  • The purposes of this study were to investigate the state of indoor thermal and air environment during winter in the one-room type multi-family houses occupied by university students and to analyze factors which influenced this environment. Field survey was conducted in 10 houses between 30th January, 2009 and 13th February, 2009 which measured indoor thermal and air elements as well kept records of interviews with residents and other related factors. Measured elements were air temperature, relative humidity, as well as concentrations of $CO_2$, CO, TVOC, and PM-10. The results can be summarized as follows. 1) The mean air temperature in each house ranged from 19.3 to $25.3^{\circ}C$, so most houses were not suitable for evaluation criteria($20-22^{\circ}C$). The average $CO_2$ concentration in each house was 965~3259ppm, so most houses exceeded evaluation criteria(1000ppm). The average TVOC concentration in each house were 0.00~1.17ppm, 5 houses exceeded evaluation criteria(0.12ppm). 2) Relative humidity, CO concentration, and PM-10 concentration were suitable for evaluation criteria. Therefore, indoor thermal and air environment during winter in one-room type multi-family housing occupied by university students was found to be generally uncomfortable. Important factor which were found to influence air temperature and the concentration of $CO_2$ were smaller space capacity than general house. Other factors which were found to influence the environment of these houses were the existence of a balcony as well as factors relating to the behavior of occupants such whether or not heating were operated, whether windows were opened, whether fans used, whether occupants smoked or used cosmetics, and whether the space was dusted.

Indoor Air-Conditioning System in building Using Lower Power Wireless Sensor Network (저전력 무선센서 네트워크를 이용한 빌딩 내 환경공조 시스템)

  • Lee, Seung-Chul;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.397-400
    • /
    • 2007
  • Indoor air-conditioning system(IAS) using wireless sensor network serves to reduce the amount of pollution entering the room from outside and also the pollution that is generated indoor. Small-size and lower power wireless sensor node and sensor interface board was designed for indoor air-conditioning system in buildings of offices and industrial establishments. Many sensor nodes forms Ad-hoc network topology using simple forwarding routing to transmit polluting gas concentration data from different rooms to the indoor air-conditioning system. Sensor node analyzes pollution concentration in the each room and air-conditioning system performs to air-distribution and air-inhalation according to room's pollution by regulating the fan of indoor air-conditioning system. To reduce power consumption electrochemical gas sensor was used in the design. Thus the designed system can optimize state of indoor environment. Graphic user interface displays node sate, gas concentration and temperature of each room.

  • PDF

Improvement of Biomineralization of Sporosarcina pasteurii as Biocementing Material for Concrete Repair by Atmospheric and Room Temperature Plasma Mutagenesis and Response Surface Methodology

  • Han, Pei-pei;Geng, Wen-ji;Li, Meng-nan;Jia, Shi-ru;Yin, Ji-long;Xue, Run-ze
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.9
    • /
    • pp.1311-1322
    • /
    • 2021
  • Microbially induced calcium carbonate precipitation (MICP) has recently become an intelligent and environmentally friendly method for repairing cracks in concrete. To improve on this ability of microbial materials concrete repair, we applied random mutagenesis and optimization of mineralization conditions to improve the quantity and crystal form of microbially precipitated calcium carbonate. Sporosarcina pasteurii ATCC 11859 was used as the starting strain to obtain the mutant with high urease activity by atmospheric and room temperature plasma (ARTP) mutagenesis. Next, we investigated the optimal biomineralization conditions and precipitation crystal form using Plackett-Burman experimental design and response surface methodology (RSM). Biomineralization with 0.73 mol/l calcium chloride, 45 g/l urea, reaction temperature of 45℃, and reaction time of 22 h, significantly increased the amount of precipitated calcium carbonate, which was deposited in the form of calcite crystals. Finally, the repair of concrete using the optimized biomineralization process was evaluated. A comparison of water absorption and adhesion of concrete specimens before and after repairs showed that concrete cracks and surface defects could be efficiently repaired. This study provides a new method to engineer biocementing material for concrete repair.

Housing Needs According to the Employment State of House Wives (주부의 취업유무에 따른 주거요구)

  • 윤정숙;김수경
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.7
    • /
    • pp.143-153
    • /
    • 1999
  • The purpose of this study was to analyze the differences in housing needs between employed and unemployed wives. A questionnaire survey including 25 questions was done in 90 employed wives and 101 unemployed wives living in Seoul. The findings were as follows: 1) The housing needs for children(educational institute, and community facilities) were high both employed and unemployed wives. The needs for the socialization facilities of household work were low both employed and unemployed wives. The employed wives who have only limited time did not want 24 hours market which is not different from unemployed wives. 2) Unemployed wives wanted larger housing spaces than employed wives did. Unemployed wives put much more value on kitchen size and design. Employed wives considered space for family such as living room and dining room more important than private space.

  • PDF

The correlation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner (가정용 에어컨 실외기의 기동 소음 분석)

  • Son, Young-boo;Lee, Seung-mock;Ha, Jong-hun;Lee, Byeoung-chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.577-582
    • /
    • 2012
  • Recently, noise reduction of air-conditioner is one of the important design factors for high quality product. Especially, customer complaints arise due to noise problem of the outdoor unit. After the operation of air-conditioner start, noise level of outdoor unit is increased gradually and sometimes abnormal noise occurs until it reaches steady state condition. The aim of this paper is to investigate the relation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner. In order to find out the noise characteristics of outdoor unit, noise and vibration measurements are carried out. Also, the thermodynamic properties of compressor and heat exchanger are measured by using temperature and pressure sensors and experimental results are discussed. Finally, we find out the relation between noise and cycle properties at starting of room air-conditioner and the improvement method to reduce noise level is proposed.

  • PDF

Numerical Analysis of Natural Convection inside Spray Coating Room on Temperature Distributions (자연대류를 고려한 스프레이 코팅 룸에서의 온도분포 해석)

  • Kim, Nam Woong;Kim, Bo-Seon;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.425-430
    • /
    • 2019
  • Zinc coatings are widely used because of their environmental friendliness and high performance. In general, the coating temperature is a major factor in determining the coating layer thickness and coating quality. In the case of a zinc coating, a uniform and appropriate coating temperature is required. In this study, a thermal flow simulation of the air flow was performed to analyze the temperature distribution of a zinc spray coating room in a natural convection state. Using SolidWorks, modeling was performed for two spray coating rooms, a preheating room, and a drying room, and a thermal flow coupled analysis was performed using ANSYS-FLUENT. As a result of the analysis, the temperature distribution characteristics in the spray coating rooms were determined. It was found that the present temperature was below the target temperature of $25^{\circ}C$. Simulations were conducted for two different boundary conditions (one with a heater added and another with the open part closed). The simulation results show that the method of closing the open part is better than adding the heater.

Suppression Design of Smart Room Garden·Aquaculture System using PIC (스마트 Aquaponix 시스템 설계)

  • Choi, Yang-il;Kim, Byeong-Jun;Jeong, Hui-Tae;Shin, Kyoo-Jae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.10a
    • /
    • pp.350-352
    • /
    • 2018
  • In this paper, we propose a smart indoor garden aquaculture system using PIC. In the proposed smart indoor garden aquaculture system, the aquaphonics system circulates the nutrient solution of the aquarium, the filtrate tank, and the flowerpot. The automated control system that controls the state of the nutrient solution through the various sensors and controls the pump and valve is designed. As a result of the verification of the smart indoor garden aquaculture system proposed in this paper, it was confirmed that the environment suitable for the survival of fish and plants was maintained by monitoring water temperature, DO, pH measured in real time. The water level in aquarium and flower pot was controlled through automatic operation of the Electric vale and pump.

The Effect of Glove Changing during Surgery for Colon Cancer (대장암수술 시 장갑교환의 효과)

  • Park, Eunji;Ham, Eunmi
    • Korean Journal of Adult Nursing
    • /
    • v.26 no.1
    • /
    • pp.98-106
    • /
    • 2014
  • Purpose: The purpose of this study was to explore the effect of glove changing during surgery for colon cancer on reducing the degree of contamination of surgical gloves. Methods: The randomized posttest control group design was used. Total 72 surgeries of colon cancer in the K University Hospital in Seoul performed by the team of A-Surgeon and B-Scrub nurse were randomly assigned to one of the three groups. Glove changing with single-gloved state was implemented in the Experimental Group I and outer glove changing with double-gloved state was executed in the Experimental Group II. Single-gloved state was carried in the Control Group. Following the surgical procedure, specimens for bacterial culture were collected the from scrub nurse's gloves to compare the degree of contamination among the three groups. Data were analyzed with One-way ANOVA and the Scheff$\acute{e}$'s multiple comparison test. Results: The degrees of contamination of the Experimental Group I and II were significantly lower than that of the Control Group. There was no significant difference between Experimental Group I and II. Conclusion: Glove changing during surgery with either single or double-gloved state is effective in reducing the degree of contamination of surgical gloves, therefore these methods should be utilized in clinical practice.