• 제목/요약/키워드: Starting algorithm

검색결과 396건 처리시간 0.022초

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

Sensorless Starting of Direct Drive Horizontal Axis Washing Machines

  • Dianov, Anton;Kim, Nam Su;Lim, Seung Moo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.148-154
    • /
    • 2014
  • This paper describes problems of the sensorless starting of horizontal axis washing machines with direct drive and suggests solution, which was experimentally verified. Horizontal axis washing machines have very difficult conditions for the drive starting, especially at full load. Inertia of the tub and water, torque from the laundry make load torque at starting higher than rated one and sometimes even higher than the maximum torque of the motor, which makes sensorless starting extremely challenging task. This paper suggests modified open-loop starting, where control system is closed shortly after beginning at low speed and rotates the drum until laundry restructuring. To ensure proper work of the sensorless algorithm at low speed additional measures for increasing of the estimation algorithm performance have been taken. These measures include special algorithm for the drive parameters estimation, which has been developed and verified by the experimental results.

기동방식을 고려한 DC급전계통 보호알고리즘 (A Protection Algorithm for DC Railway Systems Considering Train Starting)

  • 권영진;최동민;강상희;한문섭;이재경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.307-309
    • /
    • 2004
  • A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the train starting current. The train starting current increases step by step but the fault current increases all at once. So the type of $\bigtriangleup I\;relay(50F)$ was developed using the different characteristics between the load starting current and the fault current. As for the train starting current, the time constant of train current at each step is much smaller than that of the fault current. To detect faults in U railway systems, an algorithm that is independent of train starting current. This algorithm use the time constant calculated by the method of least squares is presented in this paper.

  • PDF

서브 골 설정에 의한 아날로그 셀룰라 비선형 회로망 기반 동적계획법 (Analog Celluar Nonlinear Circuits-Based Dynamic Programming with Subgoal Setting)

  • 김형석;박진희;손홍락;이재철;이왕희
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권10호
    • /
    • pp.582-590
    • /
    • 2000
  • A fast optimal path planning algorithm using the analog Cellular Nonlinear Circuits(CNC) is proposed. The analog circuits based optimal path planning is very useful since most of the optimal path planning problems require real time computation. There has already been a previous study to implement the dynamic programming with analog circuits. However, it could not be applied for the practically large size of problems since the algorithm employs the mechanism of reducing its input current/voltage by the amount of cost, which causes outputs of distant cells to become zero. In this study, a subgoal-based dynamic programming algorithm to compute the optimal path is proposed. In the algorithm, the optimal paths are computed regardless of the distance between the starting and the goal points. It finds subgoals starting from the starting point when the output of the starting cell is raised from its initial value. The subgoal is set as the next initial position to find the next subgoal until the final goal is reached. The global optimality of the proposed algorithm is discussed and two different kinds of simulations have been done for the proposed algorithm.

  • PDF

Fourier 변환 기반 시정수 추정 알고리즘을 이용한 직류 급전계통 보호 알고리즘 (A Protection Algorithm for DC Railway Systems Using Estimation of Time Constant Based on Fourier Transform)

  • 권영진;최동민;강상희;한문섭;이재경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.14-16
    • /
    • 2004
  • A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases all at once. As for the load starting current, the time constant of load current at each step is much smaller than that of the fault current. To detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares was presented. But, It have a weakness about harmonic to calculate time constant. So in this paper, new protection algorithm for DC railway systems using estimation of time constant based on fourier transform was presented.

  • PDF

폐루프 방식의 속도 적분각을 이용한 PMSM 센서리스 초기기동 알고리즘 (Closed Type Initial Starting Algorithm for PMSM Sensorless Control Using Integrated Speed Angle)

  • 박성명;김준석
    • 전력전자학회논문지
    • /
    • 제27권1호
    • /
    • pp.18-25
    • /
    • 2022
  • The cold staring issue of permanent magnet synchronous motors (PMSM) is a chronic problem in the field of PMSM sensorless drives. A traditional starting method, called the I-F method, is widely adopted because of its simple structure. However, when using this method, the pre-defined magnitude and frequency of the starting current should be changed according to the condition of the load and machine inertia. In this paper, a smart and simple algorithm for the cold starting of PMSM is proposed. In the proposed method, an integrated control angle from the estimated electrical rotor speed is used for vector control such as the indirect vector control of the induction machine. Thus, very stable cold starting is performed regardless of the machine load condition or inertia changing.

풀 브리지 인버터 기반 단상 유도전동기의 소프트 기동 기법 (Soft Start-up Algorithm of Single-Phase Induction Motor Based on Full-bridge Inverter)

  • 김태성;강형도;황선환
    • 전기전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.258-265
    • /
    • 2018
  • 본 논문은 단상 유도전동기의 기동 시 발생하는 기동전류를 분석하고 이를 저감하기 위한 알고리즘을 제안한다. 일반적으로 단상 유도전동기는 구조적인 특성으로 인해 기동토크를 발생시킬 수 있는 별도의 기동장치가 요구된다. 본 논문에서 사용되고 있는 방법은 커패시터-기동/커패시터-운전 방식이며 타 방식 대비 기동토크가 크고 운전효율이 높은 특성이 있다. 하지만 초기 기동 시 약 5~6배에 해당되는 돌입전류가 발생하며 이로 인한 초저온 냉동고 기동 소자와 주변기기들의 소손 및 수명 저하의 원인이 된다. 기동 시 발생하는 돌입전류를 저감하기 위하여 가상 dq모델 기반의 전류제어 알고리즘을 적용하여 기동 전류를 제한하고, 정격운전에 도달 시 상용전원과 동일한 운전조건으로 전환하기 위한 알고리즘을 실험을 통하여 그 타당성을 검증한다.

새로운 직류급전계통 보호 알고리즘 (A New Protection Algorithm for DC Railway Systems)

  • 권영진;강상희;현승호;한문섭;이재경
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1280-1285
    • /
    • 2004
  • ADC railway system has low feeder voltage, The fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases all at once. As for the load starting current, the time constant of load current at each step is much smaller than that of the fault current. First, to detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares is presented in this paper.

  • PDF

A New Starting Potential Fair Queuing Algorithm with O(1) Virtual Time Computation Complexity

  • Kwak, Dong-Yong;Ko, Nam-Seok;Kim, Bong-Tae;Park, Hong-Shik
    • ETRI Journal
    • /
    • 제25권6호
    • /
    • pp.475-488
    • /
    • 2003
  • In this paper, we propose an efficient and simple fair queuing algorithm, called new starting potential fair queuing (NSPFQ), which has O(1) complexity for virtual time computation and also has good delay and fairness properties. NSPFQ introduces a simpler virtual time recalibration method as it follows a rate-proportional property. The NSPFQ algorithm recalibrates the system virtual time to the minimum virtual start time among all possible virtual start times for head-of-line packets in backlogged sessions. Through analysis and simulation, we show that the proposed algorithm has good delay and fairness properties. We also propose a hardware implementation framework for the scheduling algorithm.

  • PDF

시정수를 이용한 직류철도급전계통에서의 고장판단 및 고장점표정 알고리즘 (A Fault Detection and Location Algorithm Using a Time Constant for DC Railway Systems)

  • 양언필;강상희;권영진
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권10호
    • /
    • pp.563-570
    • /
    • 2003
  • When a fault occurs on railway feeders it is very important to detect the fault to protect trains and facilities. Because a DC railway system has low feeder voltage, The fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases at one time. So the type of $\Delta$I/ relay(50F) was developed using the different characteristics between the load starting current and the fault current. The load starting current increases step by step so the time constant of each step is much smaller than that of the fault current. First, to detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares is presented in this paper. If a fault occurs on DC railway systems it is necessary to find a fault location to repair the faulted system as soon as possible. The second aim of the paper is to calculate the accurate fault location using Kirchhoff's voltage law.