• Title/Summary/Keyword: Starting Time

Search Result 1,530, Processing Time 0.032 seconds

The Design of Flux Barrier for Improvement of Demagnetization Endurance in BLDC Motor

  • Kim, Cheol-Min;Kim, Dong-Yeong;Cho, Gyu-Won;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2181-2186
    • /
    • 2014
  • Generally, the motor inside vehicle is exposed to highly ambient temperature and large vibration according to repeatedly starting and stopping for very short time. So, in this paper, the rotor shape design was performed to improve demagnetization endurance by considering the starting current of the Brushless DC (BLDC) Motor through the Finite Element Method(FEM). As a result, the partial irreversible demagnetization was occurred by starting current at the end of Permanent Magnets of the basic model. To solve this problem, the flux barrier design was performed and the flux on the rotor core was limited. Accordingly, demagnetization endurance and operating characteristics were improved.

Motor Protection and Control with Digital Protective Relays (디지털 보호 계전기를 이용한 모터 보호 및 제어)

  • 이성환;안인석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.178-178
    • /
    • 2000
  • In this paper, intelligent methods using digital protection relay in power management and control system is developed in order to protect power systems by means of timely fault detection during operation and control at starting for induction motor which have various load environments and capacities in power systems. The digital protective relay was designed with DSP CPU(TMS320C31) to Protect and measure more quickly and precisely. The test result on the basis of KEMCl120 and IEC60255, show that the operation time error of the digital motor protection relay is improved within $\pm$5%. Also, we can control motors at starting according to starting types with simple method as programmable sequence editor. So we can improve the demerits of high cost and much manhour for rework.

  • PDF

Power Monitoring and Distributed Control by Digital Relay (디지털 계전기를 이용한 전력감시 및 분산제어)

  • Lee, Sung-Hwan;Park, Sang-Bae;Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.263-266
    • /
    • 2001
  • In this paper, intelligent methods using digital protection relay in power SCADA system is developed in order to protect power systems by means of timely fault detection during operation and control at starting for induction motor which have various load environments and capacities in power systems. The digital protective relay was designed with DSP CPU(TMS320C31) to protect and measure more quickly and precisely. The test result on the basis of KEMC 1120 and IEC60255, show that the operation time error of the digital motor protection relay is improved within ${\pm}5%$. Also, we can control motors at starting according to starting types with simple method as programmable sequence editor. So we can improve the demerits of high cost and much manhour for rework.

  • PDF

Starting Method of BLDC Motor from Standstill to Medium Speed Without any Position Sensor (위치센서없는 영구자석 매입형 전동기의 기동 방식)

  • LEE Joon-Hwan;KIM Tae-Duk
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.1-4
    • /
    • 2004
  • From standstill to medium speed which enough to sensing back EMF, it is not easy to drive without additional equipments due to directly proportional to flux. Conventional method to drive is 'align and go' method, so called v/f control that is increased voltage duty in proportion to the increase of frequency. Because it isn't consider load of motor and doesn't know rotor position exactly, current is supplied too much current or not enough to rotate motor. This paper is proposed starting method without any poison sensor and can drive a BLDC motor from standstill to the medium speed smoothly without any rattling and time delay compared with the conventional starting algorithm. To verify algorithm of this paper, experimental results are presented.

  • PDF

Analogue type Starter of Single Phase Induction Motor Removing Noise and Arc (소음과 불꽃을 제거한 단상유도전동기의 아날로그식 기동기 설계)

  • Park Su-Kang;Cho Geum-Bae;Baek Hyung-Lae;Lim Yang-Su;Lee Sung-Kil;Lim Jong-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.654-656
    • /
    • 2001
  • This research used triac that is semi-conductor that act to static contact to overcome happened shortcoming been using mechanical centrifugal force switch usually Detect starting current of single phase induction motor and decided moving time. Therefore, could improve life of switch semipermanently. Also, wish to reduced impact that electric motor suffers at the starting moment and do stable starting which there is no life improvement and noise of electric motor itself, arc.

  • PDF

The Rotor Barrier Design of the BLDC Motor Consider that Irreversible Demagnetization of Permanent Magnets (영구자석의 불가역 감자 현상을 고려한 BLDC 전동기의 회전자 자속 장벽 설계)

  • Kim, Cheol-Min;Cho, Gyu-Won;Kim, Gyu-Tak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.48-53
    • /
    • 2014
  • Generally, the usage motor in the vehicle is exposed to highly ambient temperature and large vibration according to repeatedly starting and stopping during very short time. So, in this paper, the rotor shape design was performed to improve demagnetization endurance by considering starting current of Brushless DC Motor (BLDCM) through Finite Element Method(FEM). As a result, the end of Permanent Magnet (PM) in the basic model was occurring a partial irreversible demagnetization by starting current. To solve this problem, the installing flux barrier was limited to flux line on the core. Accordingly, demagnetization endurance and operating characteristics were improved.

Characteristics of the Starting Flow of a Rushton Turbine Mixer (러쉬톤 교반기의 초기 비정상 유동 특성)

  • Park, Gyeong-Hyeon;Kim, Gyeong-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1543-1551
    • /
    • 2001
  • The characteristics of starting flow of a six-blade Rushton turbine mixer were investigated by using a cinematic Particle Image Velocimetry technique. The flows were quantified by measurements of velocity fields with a 4 ms time interval for a blade rotational speed of 100 r.p.m, so that the turbine Reynolds number(ND$^2$/ ν) was fixed to 6,960. The radial shedding of the trailing vortices starts from passing four blades after the beginning of rotation. It clearly shows that the vortex pairing phenomena caused by the interactions between trailing cortices firm consequtive blades. The average convection velocity of the radial flow is found to be 28 % of the tip velocity. The starting flow seems to arrive at a steady state after 8 revolutions in this study, which corresponds nearly one circulation through the bulk flow trajectory with the average radial convection velocity.

Analog Celluar Nonlinear Circuits-Based Dynamic Programming with Subgoal Setting (서브 골 설정에 의한 아날로그 셀룰라 비선형 회로망 기반 동적계획법)

  • Kim, Hyong-Suk;Park, Jin-Hee;Son, Hong-Rak;Lee, Jae-Chul;Lee, Wang-Hee
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.10
    • /
    • pp.582-590
    • /
    • 2000
  • A fast optimal path planning algorithm using the analog Cellular Nonlinear Circuits(CNC) is proposed. The analog circuits based optimal path planning is very useful since most of the optimal path planning problems require real time computation. There has already been a previous study to implement the dynamic programming with analog circuits. However, it could not be applied for the practically large size of problems since the algorithm employs the mechanism of reducing its input current/voltage by the amount of cost, which causes outputs of distant cells to become zero. In this study, a subgoal-based dynamic programming algorithm to compute the optimal path is proposed. In the algorithm, the optimal paths are computed regardless of the distance between the starting and the goal points. It finds subgoals starting from the starting point when the output of the starting cell is raised from its initial value. The subgoal is set as the next initial position to find the next subgoal until the final goal is reached. The global optimality of the proposed algorithm is discussed and two different kinds of simulations have been done for the proposed algorithm.

  • PDF

Study of Europium-activated Calcium Aluminium Silicate Phosphors (유로피움-활성화 칼슘 알루미늄 실리케이트 형광체 연구)

  • Hwang, Jung-Ha;Park, Ju-Seok;Jang, Bo-Yun;Nahm, Sahn;Kim, Joon-Soo;Yu, Soon-Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1020-1024
    • /
    • 2006
  • Europium$(Eu^{2+}\;or\;Eu^{3+})$-activated calcium aluminium silicate phosphors were synthesized for the first time and the structures and luminescence characteristics of these phosphors were investigated. The phosphors in this study emitted blue, green, and even red light depending on the starting milterials and annealing conditions for synthesis. In addition, the structure was also changed when the different starting materials were used. When $CaCO_3$ was used as a starting material, tetragonal $Ca_2Al_2SiO_7$ was formed. However, pure green light was emitted when the annealing was conducted in reduced atmosphere and red one was emitted by annealing in air. In the case of $CaSiO_3$ as a starting material, triclinic $CaAl_2Si_2O_8$ was formed and only pure blue emission was observed. Moreover, this blue phosphor exhibited higher intensity than that of commercial YAG:Ce phosphor, which showed the possibility of application on the phosphor for new light source such as a UV-LED.

A Study on the Feasibility Analysis and Capacity Estimation of BESS for Self-Starting Generators (자체기동발전원으로서 BESS의 활용가능성 분석 및 용량 산정에 관한 연구)

  • Kim, Cha-Nyeon;Yu, Won-Kun;kim, Heon-Tae;Lee, Heung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1119-1124
    • /
    • 2018
  • So far BESS(Battery Energy storage system) has been widely applied to power systems rapidly. Usually it has been used to regulate the renewable energy output and to adjust the power system frequency. In 2013, EPRI has reported a study of utilizing BESS to replace two black start generators of American Electric Power(AEP) that will be demolished. If the BESS can be used as a self-starting generator, it is possible to shorten the long-distance primary transmission line and shorten the restoration time because BESS is capable of the high-speed start and there is no restriction on the installation position. This paper presents a possibility of using BESS as a self-starting generator by using PSCAD/EMTDC in Korean power systems. Herein, the process to estimated the required capacity of BESS is also presented.