• Title/Summary/Keyword: Starting Performance

Search Result 812, Processing Time 0.023 seconds

SIMULATION OF STARTING PROCESS OF DIESEL ENGINE UNDER COLD CONDITIONS

  • Park, J.K.
    • International Journal of Automotive Technology
    • /
    • v.8 no.3
    • /
    • pp.289-298
    • /
    • 2007
  • A nonlinear dynamic simulation model from cranking to idle speed is developed to optimize the cold start process of a diesel engine. Physically-based first order nonlinear differential equations and some algebraic equations describing engine dynamics and starter motor dynamics are used to model the performance of cold starting process which is very complex and involves many components including the cold start aiding method. These equations are solved using numerical schemes to describe the starting process of a diesel engine and to study the effects of cold starting parameters. The validity of this model is examined by a cold start test at $-20^{\circ}C$. Using the developed model the effects of the important starting variables on the cold starting processes were investigated. This model can be served as a tool for designing computer aided control systems that improve cold start performance.

A Study on the Improvement of Engine Starting Performance for Gasoline Engine Ignition System using Electronic Control (가솔린관 점화장치의 전자제어에 의한 시동성향상에 관한 연구)

  • 김광조;김남호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.215-221
    • /
    • 1997
  • The ability of the engine starting performance of conventional ignition system being currently used in automobile gasoline engine is investigated, and the method of improving is discussed and experimented. The conventional ignition system cannot obtain high ignited voltage because its current is limited by decreasing of terminal voltage of battery at starting the engine also causes irregularity in the starting engine. This paper shows that problem can be improved practically by control of ignition energy properly according to the engine speed, consequently this experimental ignition system can eliminate to remarkable extent the function of the engine starting, and also enhance the performance of the engine at high speed.

  • PDF

Rotor Design to Improve Starting Performance of the Line-start Synchronous Reluctance Motor

  • Jung Tae-Uk;Nam Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.320-326
    • /
    • 2006
  • A single-phase line-start synchronous reluctance motor (LSSynRM) has merits of low cost, high efficiency and reliability. LSSynRM has an unbalanced magnetic circuit caused by flux barriers and various shapes of conductor bars when starting. Thus the motor may generate unstable starting torque in accordance with the initial starting position of the rotor. This paper presents the rotor design to improve starting performance of the LSSynRM. Design variables are the number and the shape of the conductor bars. This design result is compared with the initial prototype and single-phase induction motor.

The Starting Characteristics Improvement of Single-Phase Induction Motor Reducing Over Current

  • Baek, Hyung-Lae;Oh, Keum-Gon;Cho, Geum-Bae;Park, Su-Kang;Lim, Yang-Su
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.531-533
    • /
    • 1996
  • The most common method of the single phase induction motor(SPIM) is to install a starting condenser and a centrifugal switch in series with the auxiliary winding. Even though this capacitor start method is embodied simply, it is feasible because of motor failure from malfunction of the centrifugal switch and the starting condenser. Moreover, it is hard to improve the performance characteristics of the SPIM. In this paper, the voltage and phase angle sequence, control strategy of the auxiliary winding of the SFIM is employed to eliminate the centrifugal switch and the starting condenser. The proposed control system is superior to a conventional system in the starting performance of SPIM. Finally, the improved starting characteristics of the SPIM is obtained with this strategy through simulation and experimental results.

  • PDF

Dynamic Modelling and Simulation of Engine Starting Process for Optimization of Diesel Engine Cold Starting System (디젤 엔진 저온 시동 시스템 최적화를 위한 엔진 시동 과정의 동적 모델링 및 시뮬레이션)

  • Park, Jung-Kyu;Bae, Keun-Sik;Yoo, Cheon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.1
    • /
    • pp.32-39
    • /
    • 2000
  • To optimize the cold start process of a 4-stroke, 8 cylinder Diesel engine, a dynamic simulation model from cranking to idle speed is developed. Physically-based first order starter motor dynamics are used to model the performance of starting process which is very complex. These equations are solved using numerical schemes(Petzold-Gear BDF method) to describe the starting process of diesel engine and to study the effects of starting parameters. The validity of this model is examined by start test. This model can be served as a tool for computer aided control systems design to improve cold improve cold start performance.

  • PDF

Performance of Non-starting Conditioning System using Thermoelectric Modules for Hybrid Heavy Trucks (대형 하이브리드 트럭용 열전 무시동 공조시스템 성능 연구)

  • Park, Kyungmin
    • Tribology and Lubricants
    • /
    • v.29 no.5
    • /
    • pp.310-317
    • /
    • 2013
  • To reduce vehicle fuel consumption due to not only driving but also air conditioning, battery-operated non-starting conditioning systems with thermoelectric modules and without mechanical elements like compressors are being manufactured for use by hybrid heavy trucks in the near future. In this study, the voltage and current consumed by a thermoelectric module were measured to determine the required battery power, and the performance of the conditioning system with air temperature, and humidity of the inlet/outlet modules and inside/outside the cabin for a truck, was evaluated using experimental apparatus under actual conditions. The results showed that, the thermoelectric module can be continously operated for about 1.5 h using existing 24 V batteries. The coefficent of performance(COP) of the cooling and heating modes was calculated to be an average 0.8-1.32. As expected, the heating performance was 30% more efficient than the cooling performance, which is general characteristic of thermoelectric modules.

A Study on Aerodynamic Analysis and Starting Simulation for Horizontal Axis Wind Turbine Blade (수평축 풍력발전용 회전날개의 공력성능 해석 및 시동특성 모사에 관한 연구)

  • 공창덕;방조혁;김학봉
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.3
    • /
    • pp.40-46
    • /
    • 1999
  • Aerodynamic performance and starting characteristic of wind turbine blade are important factors that determine the whole system as rated power, operating method, etc. Therefore, starting characteristic according to aerodynamic performance, wind speed and blade pitch angle should be examined while wind turbine blade is designed. In this study, the aerodynamic analysis program of 750㎾ class horizontal axis wind turbine blade was developed and to certify this program, the aerodynamic performance of the commercialized blade was analyzed with it. The analysis result was corresponding to the value presented from manufacturer. And the starting analysis program was developed on the basis of the developed aerodynamic analysis program and starting analysis was performed. As a result, it was confirmed that variable speed operation and variable pitch control are profitable to wind turbine used in low wind speed as our country.

  • PDF

Transient Analysis of Single-Phase Line-Start Permanent Magnet Synchronous Motors (단상 영구자석형 유도동기기의 과도상태해석)

  • Lee, Sun-Kwon;Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.147-149
    • /
    • 2001
  • The single-phase line-start permanent magnet motor has been shown to be capable of very desirable steady state performance, but known to have undesirable starting performance. This is because magnetic braking torque. So, it is very important to predict starting performance accurately when designing the line-start motors. In this paper, starting performance was calculated by combination of d-q axis voltage equations and mechanical dynamic equations. D-q axis voltage components were derived by winding angle and turns ratio transformations.

  • PDF

The Starting Characteristics of Single-Phase Induction Motor Using Sequence Controller (순서접속제어에 의한 단상유도전동기의 기동특성)

  • 박수강;성경민;조금배;오금곤;백형래;박해암
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.76-79
    • /
    • 1996
  • The most common for starting a single phase induction motor is to install a starting condenser and a centrifugal switch in series with the auxiliary winding. Though this method is simple, life of single phase induction motor is short because of malfunction of a starting condenser and a centrifugal switch and efficiency improvement has limitation. In this paper, the starting characteristics of SPIM is improved by sequence voltage control strategy of auxiliary winding in removing a starting condenser and a centrifugal switch. Finally, the excellent starting performance of SPIM is shown through simulation and experimental results.

  • PDF

A Study on the Improvement of Starting Characteristics for Single Phase Induction Motor (단상유도전동기 기동특성 개선에 관한 연구)

  • Lim, Yang-Su;Back, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.284-286
    • /
    • 1995
  • The most common for starting a single phase induction motor is to install a starting condenser and a centrifugal switch in series with the auxiliary winding. Though this method is simple, life of single phase induction motor is short because of malfunction of a starting condenser and a centrifugal switch and efficiency improvement has limitation. In this paper, the starting characteristics of SPIM is improved by voltage and phase control strategy of auxiliary winding in removing a starting condenser and a centrifugal switch. Finally, the excellent starting performance of SPIM is shown through simulation and experimental results.

  • PDF