• Title/Summary/Keyword: Start-up Condition

Search Result 142, Processing Time 0.025 seconds

DCM DC-DC Converter for Mobile Devices (모바일 기기용 DCM DC-DC Converter)

  • Jung, Jiteck;Yun, Beomsu;Choi, Joongho
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.319-325
    • /
    • 2020
  • In this paper, a discontinuous-conduction mode (DCM) DC-DC buck converter is presented for mobile device applications. The buck converter consists of compensator for stable operations, pulse-width modulation (PWM) logic, and power switches. In order to achieve small hardware form-factor, the number of off-chip components should be kept to be minimum, which can be realized with simple and efficient frequency compensation and digital soft start-up circuits. Burst-mode operation is included for preventing the efficiency from degrading under very light load condition. The DCM DC-DC buck converter is fabricated with 0.18-um BCDMOS process. Programmable output with external resistors is typically set to be 1.8V for the input voltage between 2.8 and 5.0V. With a switching frequency of 1MHz, measured maximum efficiency is 92.6% for a load current of 100mA.

Effect of Nitrogen-Load Condition on Hydrogen Production and Bacterial Community in Continuous Anaerobic Hydrogen Fermentation Process

  • Kawagoshi, Yasunori;Nakao, Masaharu;Hino, Naoe;Iwasa, Tomonori;Furukawa, Kenji
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.123-131
    • /
    • 2007
  • Effect of nitrogen-load condition on hydrogen ($H_2$) production and bacterial community in a continuous anaerobic hydrogen fermentation were investigated. The slight $H_2$ production on extremely low nitrogen-load condition (C/N ratio: 180) at the start-up period. The highest $H_2$ production was obtained when the C/N ratio was 36, the $H_2$ production yield ($mol-H_2/mol-glucose$) reached to 1.7, and it was indicated that Clostridium pasteurianum mainly contributed to the $H_2$ production. The $H_2$ production was decreased on both the lower (C/N: 72) and higher (C/N: 18) nitrogen-load conditions. The excess nitrogen-load was not always suitable for the hydrogen production. The fluctuation of $H_2$ production seemed to be caused by a change in the bacterial community according to the nitrogen-load condition, while a recovery of $H_2$ productivity was possible by a control of nitrogen-load condition through the bacterial community change. When the nitrogen-load condition was not suitable for hydrogen production, the lactic acid concentration was increased and also lactic acid bacteria were definitely detected, which suggested that the competition between hydrogen fermentator and lactic acid producer was occurred. These results demonstrated that the nitrogen-load condition affect on the $H_2$ productivity through the change of bacterial community in anaerobic hydrogen fermentation.

  • PDF

A Study of the Transient Flow Characteristics of a Vacuum Ejector-Diffuser System.

  • Rajesh, G.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2769-2774
    • /
    • 2007
  • In vacuum ejector-diffuser systems where a finite volume secondary chamber is used, the secondary jet exhibits transient characteristics during start-up. A steady state is achieved after some time in which mass entrainment prevails indefinitely inside the ejector, though there is no flow from the secondary chamber. An attempt is made in this work to study the infinite entrainment of secondary jet into the primary jet from a finite secondary chamber, with the help of a computational fluid dynamics method. The present study is also intended to identify the operating range of vacuum ejector-diffuser systems where the steady flow assumption can be applied without uncertainty. The results obtained show that the only condition in which an infinite mass entrainment is possible is the generation of a re-circulation zone near the primary nozzle exit. The flow in the secondary chamber attains a state of dynamic equilibrium at this point. Steady flow assumption is valid only after this point.

  • PDF

An experimental study on the bypass-type DPF using pneumatic cylinder systems (공압 시스템을 이용한 바이패스형 매연여과장치의 실험적 연구)

  • KIM, Sang-Am
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.1
    • /
    • pp.73-80
    • /
    • 2018
  • Intermittent duty of emergency generator has problems emitting large quantities of PM and NOx in exhaust gas. The aim of this study is to propose DPF system which can be applied to medium-large emergency generators. The system is composed of soot dust collector, silencer and filter trap, which is designed to reduce PM emissions at the emergency generator start-up. The pneumatic system controls a flow direction of exhaust gas to pass through the soot collector and filter trap until the engine reaches complete combustion condition. An experiment is performed to measure PM content and concentration to analyze the performance and characteristics of the proposed system.

Adaptive control of a slim-type reactor for free radical polymerization of LDPE

  • Ham, Jae-Yong;Rhee, Hyun-ku
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.36-41
    • /
    • 1993
  • The adiabatic slirn-type autoclave reactor for free radical polymerization of LDPE is represented by a two-compartment four-cell model, which is proven effective to predict the reactor behavior as well as the polymer properties. Since the temperature distribution along the reactor axis plays the central role for the properties of the polymer product, it is important in practice to regulate the temperature in each compartment. The present study aims for the application of the adaptive control algorithm not only in the period of start-up but also during the steady state operation. It is shown that the temperature control is significantly improved over the conventional PID-control and this also brings about a reduction of variations in the polymer properties. This study demonstrates the potential application of the adaptive controller for the control of the polymerization reactor operated under the adiabatic condition.

  • PDF

Electric-optical Characteristics of LED Flat Light Source in Low Temperature Condition (저온환경에서의 LED 평판 조명의 전기광학적 특성에 대한 연구)

  • Choi, Dae-Seub;Shim, Yong-Sik;Jung, Chan-Oong;Oh, Seon;Hwang, Jong-Sun;Han, Jeong-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.205-207
    • /
    • 2009
  • LCD (liquid crystal display) industry is needed to goods of high reliability and is interested in products without harmful material. In this experiment, we made the LED backlight unit for Automotive-navigation. And for making this backlight unit we used to eight side emitting type white LEDs with 1W high power of the lumileds company. We could know that this backlight unit releases to 6500 nit in 14W power consumption and start up voltage time is under the15ms in the ambient temperature -20 $^{\circ}C$.

  • PDF

Dynamic Adjustment of Ad hoc Traffic Indication Map(ATIM) window to save Power in IEEE 802.11 DCF

  • Nam, Jae-Hyun
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.343-347
    • /
    • 2008
  • Wakeup schemes that turn off sensors' radio when communication is not necessary have great potential in energy saving. At the start of each beacon interval in the IEEE 802.11 power saving mode specified for DCF, each node periodically wakes up for duration called the ATIM Window. However, in the power saving mechanism specified in IEEE 802.11, all nodes use the same ATIM window size. Since the ATIM window size critically affects throughput and energy consumption, a fixed ATIM window does not perform well in all situations. This paper proposes an adaptive mechanism to dynamically choose an ATIM window size according to network condition. Simulation results show that the proposed scheme outperforms the IEEE 802.11 power saving mechanism in terms of the amount of power consumed and the packet delivery ratio.

An introduction to present Research and Development condition about Solid Rocket Motor for Space Launch Vehicle (우주발사체용 고체 추진기관 개발현황 소개)

  • Kwon, Tae-Hoon;Shim, Myung-Sik;Song, Jong-Kwon;Lee, Won-Bok;Choi, Seong-Han;Suh, Hyuk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.623-626
    • /
    • 2009
  • Hanwha Corporation Daejeon Plant have developed apogee Kick Motor of KSLV-I that is the first among nation space launch vehicle for five years from 2003. Now, we are joining in KSLV-II(Korea Space Launch Vehicle-II) project and developing Pyro starter which is turbo pump for the first start-up of liquid propulsion supply.

  • PDF

Analysis of Impact on Voltage Stability by Starting Synchronous Condenser in Jeju AC Network (제주계통에서 동기조상기 기동에 따른 전압안정도 영향 검토)

  • Choi, Soon-Ho;Lee, Seong-Doo;Kim, Chan-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.23-28
    • /
    • 2015
  • Two old synchronous condensers in Jeju are being replaced by new machines to operate Jeju AC network with Haenam-Jeju HVDC system stably. Before new synchronous condensers operate on site, voltage stability analysis is conducted to verify stable operation of jeju AC network. Through impedance analysis of the synchronous machine, transformer and ac network, the equivalent circuit is constructed and the voltage drop during start-up is calculated. Then, PSS/E fault analysis is performed to acquire short-circuit capacity according to the generator operation scenarios. Voltage variation when starting synchronous condenser is simulated in PSCAD/EMTDC and satisfies the operating condition of jeju AC network and HVDC #1 system.

Performance Test of MGT Combined Heat & Power System (마이크로 가스터빈 열병합 발전시스템 성능평가)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF