• 제목/요약/키워드: Standby power consumption

검색결과 73건 처리시간 0.021초

전력선통신(PLC) 방식을 이용한 스마트콘센트와 게이트웨이에 관한 연구 (A Study on the Smart Outlet and Gateway Using Power Line Communication)

  • 박성진;김유진;박인지;김진영;임창균
    • 한국전기전자재료학회논문지
    • /
    • 제33권4호
    • /
    • pp.331-335
    • /
    • 2020
  • In this study, through the accumulated technologies such as real-time monitoring of power consumption using power line communication (PLC) method, power control, and automatic blocking of standby power, to commercialize them, we developed the hardware design, algorithm, protocol and module along with data transmission using PLC. We conducted the study to develop advanced products. We also proposed cloud-based smart outlet products with a novel type of outlet. These products can measure the internal power consumption through the H/W modules and the modules that control the power of household appliances connected to the smart outlets and smart plugs. Subsequently, they transmit the measurements to the energy saving system server via a communication module. This system can control the terminal device connected to the Gateway (G/W) server through a mobile phone. This will allow the customer to check the power consumption of the building at any given time, to turn the terminal on/off, and to maximize the energy efficiency during the construction of new apartments or multi-family housing in an area.

초절전형 PLC 2구 스위치 개발 (Ultra-Power-Saving 2 Ports PLC Wall Switch Development)

  • 한재용;이순흠
    • 대한전자공학회논문지SD
    • /
    • 제44권11호
    • /
    • pp.51-55
    • /
    • 2007
  • PLC 홈 네트워크용으로 보급되고 있는 스위치, 콘센트, 가스제어기 등의 단말기들은 일반적으로 부하가 연결되지 않은 상태에도 원격제어 또는 기기 간의 제어, 상태 감시 등을 위하여 항상 Wake-up 상태를 유지하고 있어야 한다. 이로 인하여 대기 시 불필요한 전력을 소비하는 문제점을 갖고 있다. 본 논문에서는 대기 시 소비 전력 및 동작 시 소비 전력을 최소화한 절전형 PLC 2구 스위치를 개발하였다. 대기 시 소비전력 최소화를 위해 Sleep Mode 전환 및 전력선 통신부와 제어부의 분리 등 회로를 개선을 하였으며 동작 시 소비전력 최소화를 위해 유지 제어방식에서 순간 제어방식으로 전환하였으며, 이로부터 스위치 수명 연장 및 고장률을 최소할 수 있었다. 기존 스위치에 비해 대기 시 약 0.95[W] 절감, 동작 시 약 3.2[W] 절감으로 에너지 절감을 실현하였다.

K10026 기반 스마트 플러그 시스템 개발 및 성능 분석 (Development and Performance Analysis of an Effective Smart Plug System based on K10026 Regulation)

  • 정한수;이형봉;정태윤
    • 대한임베디드공학회논문지
    • /
    • 제11권5호
    • /
    • pp.287-298
    • /
    • 2016
  • This paper proposes an effective smart plug system capable of monitoring power, cutting off standby power and overload current. The key design concept is focused on measurement accuracy, self power consumption and controlling via smart phone application. The system is composed of several plugs and a hub, and adopts a star-topology-styled TDMA wireless protocol for communication between plug and hub. The test result shows that the implemented smart plug system meets K10026 regulation and is worth in electrical safety, energy saving, easy living.

대기전력저감을 위한 SMPS (SMPS for Low Standby Power Consumption)

  • 정봉근;장상호;김은수;최문기;이재삼
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.146-149
    • /
    • 2008
  • 최근 대기전력저감기능을 갖는 PWM IC를 적용한 플라이백 컨버터는 대기전력 모드 시 Burst 스위칭 동작에 의해 소모 전력을 최소화 할 수 있지만 경 부하 및 대기전력모드 시 변압기를 통해 흐르는 큰 여자전류에 의해 여전히 낮은 효율특성을 가지는 문제점이 있었다. 본 논문에서는 경 부하 및 대기전력모드 동작 시 변압기에 흐르는 여자전류를 최소화함으로 효율을 개선한 회로를 제안하였으며 50인치 PDP TV PSU (Power Supply Unit)에 있어서 대기전력 및 보조전원으로 사용된 74W 플라이백 컨버터에 적용하여 비교 검토하여 보았다.

  • PDF

Dynamic Load Profile 조건의 전원 장치에 있어서 계통 Peak Power 제한/보상 전력 회로 (Grid Peak Power Limiting / Compensation Power Circuit for Power Unit under Dynamic Load Profile Conditions)

  • 정희성;박도일;이용휘;이창현;노정욱
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.376-383
    • /
    • 2022
  • The improved performance of computer parts, such as graphic card, CPU, and main board, has led to the need for power supplies with a high power output. The dynamic load profile rapidly changes the usage of power consumption depending on load operations, such as PC power and air conditioner. Under dynamic load profile conditions, power consumption can be classified into maximum, normal, and standby power. Several problems arise in the case of maximum power. Peak power is generated at the system power source in the maximum-power situation. Frequent generation of peak power can cause high-frequency problems and reduce the life of high-pressure parts (especially high-pressure capacitors). For example, when a plurality of PCs are used, system overload occurs due to peak power generation and causes problems, such as power failure and increase in electricity bills due to exceeded contract power. To solve this problem, a system peak power limit/compensation power circuit is proposed for a power supply under dynamic load profile conditions. The proposed circuit detects the system current to determine the power situation of the load. When the system current is higher than the set level, the circuit recognizes that the system current generates peak power and compensates for the load power through a converter using a super capacitor as the power source. Thus, the peak power of loads with a dynamic load profile is limited and compensated for, and problems, such as high-frequency issues, are solved. In addition, the life of high-pressure parts is increased.

The Impact of TDDB Failure on Nanoscale CMOS Digital Circuits

  • 김연보;김경기
    • 한국산업정보학회논문지
    • /
    • 제17권3호
    • /
    • pp.27-34
    • /
    • 2012
  • This paper presents the impact of time dependent dielectric breakdown (TDDB, also called as gate oxide breakdown) failure on nanoscale digital CMOS Circuits. Recently, TDDB for ultra-thin gate oxides has been considered as one of the critical reliability issues which can lead to performance degradation or logic failures in nanoscale CMOS devices. Also, leakage power in the standby mode can be increased significantly. In this paper, TDDB aging effects on large CMOS digital circuits in the 45nm technology are analyzed. Simulation results show that TDDB effect on MOSFET circuits can result in more significant increase of power consumption compared to delay increase.

저전력 환경에서 멀티미디어 자료 재생을 위한 디스크 스케줄링 기법 (Power Conscious Disk Scheduling for Multimedia Data Retrieval)

  • 최정완;원유집;정원민
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제33권4호
    • /
    • pp.242-255
    • /
    • 2006
  • 최근에, 휴대용 컴퓨터와 모바일 장치(Smart Phone, PDA, MP3 Player 등)의 보급 증가로 인하여 모바일 환경에서의 전력 관리 기술의 필요성은 매우 증가하고 있다. 왜냐하면, 전력 관리 기술은 모바일 장치에서 가장 중요한 요소 중 하나이기 때문이다. 한편, 하드 디스크는 가격에 비하여 용량이 크고 속도가 빠르며 최근에는 모바일 장치에서 사용하기에 충분하게 작게 만들 수도 있으므로 모바일 기기에 사용하기 적당하나, 모바일 장치에 사용하기에는 소모 전력이 너무 크다는 단점이 있다. 이러한 이유들로 인하여 본 논문에서는 디스크에 저장된 연속적인 멀티미디어 자료를 실시간으로 재생하는데 소모되는 전력을 최소화하기 위한 방법을 제안하고 평가하였다. 모바일 장치에서 소모되는 전력을 엄격히 제한하는 것은 모바일 장치들의 하드웨어와 소프트웨어 디자인에 지대한 영향을 준다. 실시간 멀티미디어 재생이 기존의 텍스트 서비스와 다른 점은 디스크가 저장된 데이타 블록을 연속적으로 공급한다는 것이다. 이것은 디스크 드라이브가 멀티미디어 데이타 전체를 재생할 동안 활성화 상태를 유지해야 하게 하므로, 전력 관리 측면에서는 매우 큰 부담으로 작용한다. 전형적인 모바일 디스크 드라이브의 전력 관리 기능은 디스크가 대기 상태에 있을 때의 과도한 입출력 요청으로 인하여 멀티미디어 재생의 품질 측면에서는 부정적인 영향을 준다. 따라서, 본 논문에서는 디스크 드라이브의 전력 소모 형태를 세밀히 분석하고, 저장된 멀티미디어 데이타를 보다 효율적으로 전력을 덜 사용해 재생할 수 있는 알고리즘을 개발하였다. 이 알고리즘은 읽어야 할 데이타 블록의 수와 활성화/대기 상태의 길이를 계산한다. 이로써 본 논문에서 제안한 알고리즘은 모바일 디스크 드라이브에 저장된 데이타 블록의 연속적인 재생을 보장하는 최적의 스케줄링을 한다. 기존에 공개된 MPEG 재생기에 본 알고리즘을 적용한 멀티미디어 재생기를 만들었다. 이 재생기는 전체 재생동안 활성화 상태를 유지하는 경우와 비교하여 60%의 전력 소모량을 절약하였고, 전력 관리 모듈이 있는 디스크 드라이브에서 재생할 경우에 기존외 재생기와 비교하여 38%의 전력 소모량을 절약하였다.

신재생에너지 발전 시스템을 위한 고 품위 축전지 충방전 컨트롤러 (추적식 태양광 발전시스템을 중심으로) (A High Quality Battery Charge-Discharge Controller for New & Renewal Energy Power Generation System (Focusing on Sun-tracking Solar Power Generation System))

  • 이재민
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권4호
    • /
    • pp.258-263
    • /
    • 2011
  • 본 논문에서는 추적식 태양광 발전 시스템을 위한 고품위 축전지 충방전 컨트롤러를 설계하였다. 제안하는 컨트롤러는 태양광 발전시스템에 일반적으로 사용하는 납산축전지(연축전지)뿐만 아니라 향후 개발되어 신 재생에너지 발전 시스템에 사용될 다양한 배터리를 충전하는데 적합하도록 미세 전류조절기능을 갖춘 새로운 기능을 갖는 컨트롤러이다. 사용자 편의성을 높이기 위하여 LCD 표시기의 기능을 보강하였으며 CAD를 이용한 최적설계를 통하여 대기 전력의 최소화를 구현하였다.

다출력 컨버터에서 대기전력 개선을 위한 Secondary Side Post Regulator와 Power Sequence (Secondary Side Post Regulator and Power Sequence to Reduce Standby Power Consumption under Multiple Output Converters)

  • 정지훈;최종문;권중기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.32-34
    • /
    • 2007
  • 전자산업 부문의 친환경 대응이 이슈화 되면서 전자기기의 대기전력 소비감소를 위한 연구가 지속적으로 수행되고 있다. 전자기기의 대표적인 전원공급장치인 Switched Mode Power Supply(SMPS)의 경우 부하기기의 대기모드 시 극도로 낮은 출력전력에서 고효율을 달성해야 하는 요구가 높다. 특히 많은 SMPS들이 부하기기의 요구에 의하여 다출력 컨버터로 설계되어 있는데, 이러한 다출력 구조에서 대기모드 시 불필요한 출력을 절체함과 동시에 저전력에서 고효율을 내기가 쉽지 않다. 또한 다출력 구조로 인한 Cross Regulation 문제를 극복해야 하는 과제가 있다. 따라서 본 논문에서는 단일 컨버터 혹은 복수의 컨버터로 구성되어 있는 다출력 컨버터에서 대기전력 개선을 위한 Secondary Side Post Regulator(SSPR), 전류모드, Power Sequence 제어기술을 제안하고, 대기전력과 더불어 SSPR의 Cross Regulation 특성 개선을 검토하였다. 그리고 제안한 기술이 구현된 다출력 구조의 110W와 270W급 SMPS를 제작하여 회로의 타당성 및 우수성을 검증하였다.

  • PDF

스마트 그리드에 그린 IT 활용 연구

  • 정현수;김병식;왕미경;김종훈;한명지
    • 한국데이타베이스학회:학술대회논문집
    • /
    • 한국데이타베이스학회 2010년도 춘계국제학술대회
    • /
    • pp.33-41
    • /
    • 2010
  • Recently the number of IT equipment have increased. It consumes large amounts of energy and is emissions of greenhouse gases. Co2 emissions with the PC and the monitor has the highest percentage to 39% more than other IT equipment. In addition, Plan for your PC's power management and technology development is being pursued in developed countries. To reduce energy costs of organizations with large numbers of the PC and to cut down on Co2 emissions, the energy load control technology of ACPI standards-based PC IS suggested. AMI-based PC power-management system was constructed, Approximately 20% of operating a result of the test power consumption was reduced. Looking at the case of the United States, PC monitors from the University of Wisconsin-Oshkosh was Sleep mode. As a result, the monitor on a, $ 20 for a year reduced energy costs. In GE(General Electronic), Approximately 75,000 PC's power setting time was Monitor Off :15 minutes/ Hard Drives Off 30 minutes/ System Standby 30 minutes/ Hibernation mode 2 hours. 1 year, electric bill was $ 2.5 million savings and 3 years electric bill was $ 6.5 million savings. Measuring energy usage data, using the measured data, electric energy management technology is not. Platform development to measure energy usage for Individual energy-consuming equipment is urgently required.

  • PDF