• Title/Summary/Keyword: Standardized materials

Search Result 582, Processing Time 0.025 seconds

Development of a Storage Level and Capacity Monitoring and Forecasting Techniques in Yongdam Dam Basin Using High Resolution Satellite Image (고해상도 위성자료를 이용한 용담댐 유역 저수위/저수량 모니터링 및 예측 기술 개발)

  • Yoon, Sunkwon;Lee, Seongkyu;Park, Kyungwon;Jang, Sangmin;Rhee, Jinyung
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.1041-1053
    • /
    • 2018
  • In this study, a real-time storage level and capacity monitoring and forecasting system for Yongdam Dam watershed was developed using high resolution satellite image. The drought indices such as Standardized Precipitation Index (SPI) from satellite data were used for storage level monitoring in case of drought. Moreover, to predict storage volume we used a statistical method based on Principle Component Analysis (PCA) of Singular Spectrum Analysis (SSA). According to this study, correlation coefficient between storage level and SPI (3) was highly calculated with CC=0.78, and the monitoring and predictability of storage level was diagnosed using the drought index calculated from satellite data. As a result of analysis of principal component analysis by SSA, correlation between SPI (3) and each Reconstructed Components (RCs) data were highly correlated with CC=0.87 to 0.99. And also, the correlations of RC data with Normalized Water Surface Level (N-W.S.L.) were confirmed that has highly correlated with CC=0.83 to 0.97. In terms of high resolution satellite image we developed a water detection algorithm by applying an exponential method to monitor the change of storage level by using Multi-Spectral Instrument (MSI) sensor of Sentinel-2 satellite. The materials of satellite image for water surface area detection in Yongdam dam watershed was considered from 2016 to 2018, respectively. Based on this, we proposed the possibility of real-time drought monitoring system using high resolution water surface area detection by Sentinel-2 satellite image. The results of this study can be applied to estimate of the reservoir volume calculated from various satellite observations, which can be used for monitoring and estimating hydrological droughts in an unmeasured area.

Questionnaire survey for the clinical trial participants who experienced both digital and conventional impression (디지털 인상법과 종래인상법을 동시에 경험한 임상시험자를 대상으로 한 설문지분석)

  • Yang, Eunbee;Kim, Bongju;Lee, Jun Jae;Lee, Seung-Pyo;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.270-279
    • /
    • 2018
  • Purpose: The aim of this study was to assess the patients' perception, acceptance, and preference of the difference between a conventional impression and digital impression through questionnaire survey. Materials and Methods: Thirteen (6 male, 7 female) subjects who experienced both digital and conventional impression at the same day were enrolled in this study. Conventional impression were taken with polyvinylsiloxane and digital impression were performed using a newly developed intra-oral scanner. Immediately after the two impressions were made, a survey was conducted with the standardized questionnaires consisting of the following three categories; 1) general dental treatment 2) satisfaction of conventional impression 3) satisfaction of digital impression. The perceived source of satisfaction was evaluated using Likert scale. The distribution of the answers was assessed by percentages and statistical analyses were performed with the paired t-test, and P < 0.05 was considered significant. Results: There were significant differences of the overall satisfaction between two impression methods (P < 0.05). Digital impression showed high satisfaction in less shortness of breath and odor to participants compared to conventional impression. The use of an oral scanner resulted in a discomfort of TMJ due to prolonged mouth opening and in lower score of the scanner tip size. Conclusion: It was confirmed that the preference for the digital impression using intraoral scanner is higher than the conventional impression. Most survey participants said they would recommend the digital impression to others and said they preferred it for future prosthetic treatment.

Analysis of esthetic factors and evaluation of esthetic perception for maxillary anteriors of dental students (치과대학생의 상악 전치부의 심미적 요소 분석 및 인식도 평가)

  • Kim, Seon-Kyung;Kim, Ok-Su
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.118-126
    • /
    • 2019
  • Purpose: This research is to investigate factors that affect dental aesthetics and analyze whether individual perception affects and difference of genders affects the esthetic factors. Materials and methods: Seventy dental students of Chonnam University aged from 25 to 35 years old without periodontal problems were included. Maxillary dental cast for participants were made, and standardized photo was taken with a digital camera. Maximum visual width and the position of gingival zenith of maxillary anterior teeth and maximum height of the maxillary central incisors were measured by a measurement program and the shape of central incisor was categorized. Questionnaire was conducted to evaluate esthetic perception. SPSS program was used to perform statistical analysis. Results: The average visual width ratio of right maxillary anteriors was 1.38:1:0.78 and 1.41:1:0.81 for the left which differ from the golden ratio. The width to height ratio for right and left central incisor was 0.84 and 0.83 respectively. The gingival zenith position was determined to be: mostly, central incisors and canines were located in the distal side, lateral incisors were located in the center. The visual width ratio of right maxillary anterior teeth, ratio of width to height of central incisor, gingival zenith position, crown morphology and amounts of gingival exposure upon smiling were not significantly different between genders, and facial patterns and these dental esthetic factors were not related to aesthetic perception. Conclusion: Even though participants had the visual width ratio of maxillary anteriors or ideal width to ideal height of central incisors that did not agree with the golden ratio, they had high satisfaction for dental esthetics. Esthetic perception depends more on subjective judgements of participants than objective indices.

The Transmission Direction and Tasks of Ssireum as a National Intangible Cultural Heritage (씨름의 국가무형문화재 전승방향 및 과제)

  • Kwak, Nak-hyun
    • (The)Study of the Eastern Classic
    • /
    • no.67
    • /
    • pp.203-236
    • /
    • 2017
  • The objective of this study is to suggest the transmission direction and tasks of Ssireum, and the conclusions are like below. First, Ssireum has been designated as a national intangible cultural heritage(No.131) in December 2016. Second, in the current status of preservation and spread of Ssireum, there is no system related to the transmission of Ssireum such as cultivation of professional manpower, and facilities, programs, and administration/finance for transmitting Ssireum. Third, based on the "Intangible Cultural Heritage Preservation & Promotion Act", the transmission direction of Ssireum was suggested. (1)The designation of a college to transmit Ssireum would be needed. (2)The Ssireum curriculum should be established. (3) It would be necessary to secure trainees for transmitting Ssireum. (4)The production of teaching materials for transmitting Ssireum would be needed. (5)It would be needed to secure training institutes designated in each region and also teaching personnels for transmitting Ssireum. (6)The research direction for the correct transmission of Ssireum should be set up. Fourth, based on the "Ssireum Promotion Act", the transmission direction of Ssireum was suggested. (1)It is urgent to complement provisions for transmitting Ssireum. (2)For the transmission of Ssireum, instead of the transmission direction of Ssireum as a national intangible cultural heritage in the standardized perspective, it would be necessary to seek for the joint transmission direction between South & North Korea for research & documentation of Ssireum that could be systematized/shared between South & North Korea, development/spread of contents for discovering the original form of Ssireum, and the establishment of a base of transmission system for the preservation/promotion of Ssireum through the academic/institutional exchanges regarding Ssireum between South and North Korea. Moreover, the overall and fundamental transmission measures for the education, transmission, research, record, and informatization of Ssireum, and the cultivation of professional manpower should be established. Fifth, the contents of institutional tasks for Ssireum are like following. (1)The institutional complementation of the "Ssireum Promotion Act" should be done for the domestic/foreign promotion of Ssireum. (2)For the integration of Ssireum organizations, the administrative system should be unified. (3)The standard technical system manual for Ssireum should be produced. (4)The 'Ssireum Transmission Center' should be built for the preservation and systematic transmission of Ssireum. (5)The selection of a college for transmitting Ssireum and the establishment of a system to cultivate Ssireum successors should be done. (6)It would be necessary to establish database(DB) for the use of Ssireum techniques essential for the transmission of Ssireum.

Discrepancy and Correlation in the renal length between Kidney CT and 99mTc-DMSA Renal scan (신장 CT 검사와 99mTc-DMSA Renal Scan 검사에서 측정한 신장 길이의 차이 및 상관분석)

  • Jung, Woo-Young;Shim, Dong-Oh;Lee, Dong-Hun;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • Purpose This article studies the relationship between the length of a kidney measured by two scanning methods: Kidney Computed Tomography (CT) and 99mTc-Dimercaptosuccinic acid (DMSA) renal scan. Kidney CT provides a better anatomic assessment, while 99mTc-DMSA renal scan is superior in the kidney function test. Materials and Methods From January to December of 2019, two hundred patients who had Kidney CT and Tc99m-DMSA renal scan were chosen for this study. SPSS17.0 was selected for statistical analysis. Results Due to the effect of the breathing and resolution of 99mTc-DMSA renal scan, it showed the kidney's relatively longer length than the length of Kidney CT. For the same kidney, the length comparison among different brands' Gamma cameras was negligible. The length difference within the same age group did not show a noticeable discrepancy. However, there was a length difference between the radio technologists. Kidney CT and 99mTc-DMSA renal scan indicated a strong positive correlation between the length of the left and right kidney. Conclusion It is necessary to establish a standardized measurement method for measuring kidney length using 99mTc-DMSA renal scan. The kidney's functional changes and length changes are indications of Kidney diseases. Especially, pediatric patients tend to use 99mTc-DMSA renal scan for assessing the kidney's shape and the function to avoid potential radiation exposure during the Kidney CT. Therefore, it is significant to provide not only the kidney's functional information but also an anatomic analysis, including the kidney's size, length, and location through the 99mTc-DMSA renal scan.

Clinical Result of a Staged Reimplantation of Fungus Related Periprosthetic Joint Infection after Total Knee Arthroplasty (슬관절 전치환술 후 인공관절 주위 진균 감염의 임상적 결과)

  • Kim, Hyung Joo;Bae, Ki Cheor;Min, Kyung Keun;Choi, Hyeong Uk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • Purpose: Fungal periprosthetic joint infection (PJI) is a rare but devastating complication following total knee arthroplasty (TKA). On the other hand, a standardized procedure regarding an accurate treatment of this serious complication of knee arthroplasty is lacking. The clinical progress of staged reimplantation in patients who had fungus-related PJI after TKA was reviewed retrospectively. Materials and Methods: Ten patients who had a fungal related PJI after TKA between 2006 and 2017 using staged reimplantation surgery were reviewed. These patients were compared with 119 patients who had a PJI in the same period. The failure rate of infection control, intravenous antimicrobial using the period, and the clinical results were evaluated by comparing the range of motion and Korean knee score (KKS) between pre-staged reimplantation and the last follow-up. Results: In the fungal infection group, 7 out of 10 cases (70.0%) had failed in infection control using staged reimplantation and in the non-fungal group, 7 out of 119 cases (5.9%) had failed (p=0.04). In the non-fungal group, the mean duration of antibiotics was 6.2 weeks. In the fungus group, the mean duration of antibiotics was 15.3 weeks, which was 9.1 weeks longer (p<0.001). The range of motion of the knee was increased in the two groups (p=0.265). At the last follow-up, the KKS was 71.01 points in the non-fungal group and 61.3 points in the fungal group (p=0.012). Erythrocyte sedimentation rate and C-reactive protein (CRP) decreased in the two groups, but the CRP was significantly different in the two groups (p=0.007). Conclusion: The treatment of fungus-related PJIs using staged reimplantation showed uneven clinical progress and unsatisfactory clinical improvements compared to non-fungal PJI. Therefore, it is necessary to consider the use of an antifungal mixed cement spacer at resection arthroplasty and oral antifungal agent after reimplantation.

Analysis on Topokki Franchise Industry and Its Proactive Activities: Focused on Kukdae Toppokki (떡볶이 프랜차이즈 산업의 분석과 그에 따른 선제적 대응 방안: 국대떡볶이를 중심으로)

  • Chi, I hyun;Han, Kyu won;Choi, Yae jin;Son, Jeong Sook;Kim, Ji-Hern
    • The Korean Journal of Franchise Management
    • /
    • v.5 no.1
    • /
    • pp.27-47
    • /
    • 2014
  • This research was conducted on the purpose of seeking the measures of how to cope with the changing industry of Topokki franchises. Despite of the fact the number of Kukdae Topokki's stores is quite smaller than that of its competitors, such as Jaws Topokki and Addal Topokki, Kukdae Topokki is recognized as one of the front-runners in the industry. But the competition in the topokki industry has become fiercer, as the market became saturated. To find a desirable solutions, this study analyzes past-to-current status of the Topokki industry by dividing it into 4 stages and provides few strategies that Kukdae Topokki can apply to the 4th stage where 'brand awareness' is very important. To this end, few drawbacks of Kukdae Topokki are proposed as the following. First, the brand image that Kukdae Topokki pursue does not correspondent with the image in consumer's mind. Second, Kukdae Topokki has selected the wrong targeting group. It aims for the image of 'retro' to target people in their 30-40s. However, most of the consumers are people in their 20-30s. Third, the taste of Kukdae Topokki is not uniform among franchises. Fourth, the awareness and accessability are low. To provide a proactive actions for the next stages, several solutions are proposed as following. First, By managing consistent Kukdae Topokki's Brand Touch point, consumers may have a strong image on the brand by communicating with consumers consistently at all touch points. Second, instead of the existing guide from the head office(franchiser), a standardized criteria for the usage of materials and periodical education for franchisee are needed. Third, to raise the awareness of Kukdae Topokki, open many branches in the area where the main consumers(20-30s women) are mostly spread out.

Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study (PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.3-8
    • /
    • 2016
  • Purpose SUV is one of the parameters that assist diagnosis in origin, metastasis and staging of cancer. Specially, it is important to compare SUV before and after chemo or radiation therapy to find out effectiveness of treatment. Storing PET data which has no quantitative change is needed for SUV comparison. However, there is a possibility to loss the data in external hard drive or MINIpacs that are managed by department of nuclear medicine. The aim of this study is to evaluate SUV and metabolic tumor volume (MTV) among reconstructed data (R-D) in workstation, R-D and re-sliced data (S-D) in PACS. Materials and Methods Data of 20 patients (aged $60.5{\pm}8.3y$) underwent $^{18}F-FDG$ PET (Biograph truepoint 40, mCT 40, mCT 64, mMR, Siemens) study were analysed. $SUV_{max}$, $SUV_{peak}$ and MTV were measured in liver, aorta and tumor after sending R-D in workstation, R-D and S-D in PACS to syngo.via software. Results R-D of workstation and PACS showed the same value as mean $SUV_{max}$ in liver, aorta and tumor were $2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ and $SUV_{peak}$ were $2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$(p>0.05) respectively. Mean $SUV_{max}$ of S-D in PACS were decreased by 5.18%, 7.22%, 12.11% and $SUV_{peak}$ 2.61%, 3.63%, 10.07%(p<0.05). Correlation between R-D and S-D were $SUV_{max}$ 0.99, 0.96, 0.99 and $SUV_{peak}$ 0.99, 0.99, 0.99. And 2SD in balnd-altman analysis were $SUV_{max}$ 0.125, 0.290, 1.864 and $SUV_{peak}$ 0.053, 0.103, 0.826. MTV of R-D in workstation and PACS show the same value as $14.21{\pm}12.72cm^3$(p>0.05). MTV in PACS was decreased by 0.12% compared to R-D(p>0.05). Correlation and 2SD between R-D and S-D were 0.99 and 2.243. Conclusion $SUV_{max}$, $SUV_{peak}$, MTV showed the same value in both of R-D in workstation and PACS. However, there was statistically difference in $SUV_{max}$, $SUV_{peak}$ of S-D compare to R-D despite of high correlation. It is possible to analyse reliable pre and post SUV if storing R-D in main hospital PACS system.

  • PDF

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.