• Title/Summary/Keyword: Standardized body data

Search Result 94, Processing Time 0.039 seconds

Biomechanical Effectiveness and Anthropometric Design Aspects of 3-dimensional Contoured Pillow

  • Kim, Jong Hyun;Won, Byeong Hee;Sim, Woo Sang;Jang, Kyung Seok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.503-517
    • /
    • 2016
  • Objective: The aim of this study was to evaluate the effectiveness of 3 dimensional contoured pillow through analyzing contact pressure and to suggest its design guidelines through analyzing the posture of head and neck area. Background: The quality of sleep is a very important factor closely related with human's health. To improve the quality of sleep, the verification of design factors affecting the posture of the head and neck is needed, and a pillow design that can induce proper posture is required. Method: This study measured the contact pressures of the two reference groups (bead and cotton pillows) as a method to evaluate the design effectiveness of the contoured pillow. This study proposed 3-dimensional design guidelines by drawing anthropometry (head length) affecting cervical curvature angle (CCA) through the measurement of the participants' cervical curvature angles. Results: In the design effectiveness evaluation, the contact pressure of cervical region was higher than that of a reference group (cotton pillow), and contract area increased, and contract pressure decreased in the shape distributing the occipital region's body pressure. This study proposed pillow's cervical supporting height by percentile of a head length [head length (%tile) (cervical supporting height) affecting the posture of the head and neck: 14.6cm (5%tile) (6.2cm), 15.5cm (25%tile) (6.7cm), 16.4cm (50%tile) (7.1cm), and 19.3cm (75%tile) (8.9cm)]. Conclusion: This study confirmed the contoured pillow's design effectiveness maintaining cervical angle comfortable to sleep with the shape supporting the cervical vertebrae and by reducing the contact load of the occipital region. Also, this study proposed pillow design guidelines based on the 3-dimensional contoured pillow design effectiveness, through which the study laid the foundation for pillow design in a systematic method. Application: The results of this study are expected to be utilized as the basis data by which the optimum pillow type and pillow design according to main percentile can be standardized.

Analysis of Pericardial Fluid in Patients with Cardiac Disease (심장질환환자에서 심막액의 분석)

  • 김종원;황수희
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1354-1359
    • /
    • 1996
  • Few observation have been made on the pericardial pressure and little is known about the composition of he pericardial fluid. So we studied the basic qualitative and quantitative analysis of the pericardial fluid in the patients with cardiac disease either congenital heart diasese(group A) or acquired heart disease(group B). The pressure of the pericardial cavity was measured by the method of open tipped water filled small polyethylene catheter connecting to the standardized monitor, which was introduced into pericardium of the patients who were performed pericardial incision for the heart or pericardial surgery. All of the data was compared to the simultaneously checked hematologic value of the same patient. The mean pressure of the pericardial cavity was 2.4mmHg and the amount of the pericardial fluid was 13cc/m2 of body surface for the group A and 17.7cc for the group B. And the cell count was 138$\pm$l16/1 in group A and 230$\pm$135/1 in group B and the pH was 7.83$\pm$0.40 in group A. 7.80$\pm$0.52 in group B. Pericardial fluid revealed satisfactically significant alkaline pH than plasma. The fundamental electrolyte, Wa+, K+, Cl and glucose were identical to the hematologic values of the same patient, but the protein concentration was 2.Bg/dL for group A and 3.Ig/dL for group B heart disease and those were remarkable low concentration compared to the hematologic value of the same patient. LDH and amylase were identical to the value of the serum of the same patient, but the concentration of LDH of group B was slightly higher than that of the group A.

  • PDF

Musculoskeletal Symptoms and Its Related Factors among Male Workers in a Nonferrous Manufacturing Industry (비철금속제조업 생산직 남성 근로자들의 근골격계 자각증상과 관련요인)

  • Jeong, Yeon-Ok;Cho, Young-Chae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3552-3560
    • /
    • 2012
  • This study was conducted to find out the complaint rate of musculo-skeletal disorder and its related factors from male manufacturing workers at a nonferrous manufacturing industry. As for the research subjects, 302 workers selected from a nonferrous manufacturer located in Daejeon City, and as for the collection of data, a standardized anonymous questionnaire survey were conducted from May 1, 2011 to June 30, 2011. As a results, the complaint rate of musculo-skeletal disorders by each body part, the symptom of shoulders was 42.7%, the highest rate, followed by the waist, 36.8%, the neck and the hand/wrist/finger, 30.5% respectively, the leg and foot, 30.1% and arm/elbow, 20.9%. The complaint rate of musculo-skeletal disorder for the sociodemographic characteristics was significantly high as survey participants' age and BMI were low and in the group having low subjective health condition. The complaint rate of musculo-skeletal disorder for the health-related behavior characteristics was significantly high in the group having been absent from work due for diseases, in the group having received outpatient services, in the group having been hospitalized for treatment, in the group not having a regular exercise and in the group having insufficient sleeping hours. Finally, the complaint rate of musculo-skeletal disorder for the job-related characteristics was significantly high in the group suffering from the physical burden of their work, in the group working while bending at the waist and in the group carrying out repetitive tasks.

Establishment of WBS·CBS-based Construction Information Classification System for Efficient Construction Cost Analysis and Prediction of High-tech Facilities (하이테크 공장의 효율적 건설 사업비 분석 및 예측을 위한 WBS·CBS 기반 건설정보 분류체계 구축)

  • Choi, Seong Hoon;Kim, Jinchul;Kwon, Soonwook
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.8
    • /
    • pp.356-366
    • /
    • 2021
  • The high-tech industry, a leader in the national economy, has a larger investment cost compared to general buildings, a shorter construction period, and requires continuous investment. Therefore, accurate construction cost prediction and quick decision-making are important factors for efficient cost and process management. Overseas, the construction information classification system has been standardized since 1980 and has been continuously developed, improving construction productivity by systematically collecting and utilizing project life cycle information. At domestic construction sites, attempts have been made to standardize the classification system of construction information, but it is difficult to achieve continuous standardization and systematization due to the absence of a standardization body and differences in cost and process management methods for each construction company. Particular, in the case of the high-tech industry, the standardization and systematization level of the construction information classification system for high-tech facility construction is very low due to problems such as large scale, numerous types of work, complex construction and security. Therefore, the purpose of this study is to construct a construction information classification system suitable for high-tech facility construction through collection, classification, and analysis of related project data constructed in Korea. Based on the WBS (Work Breakdown Structure) and CBS (Cost Breakdown Structure) classified and analyzed through this study, a code system through hierarchical classification was proposed, and the cost model of buildings by linking WBS and CBS was three-dimensionalized and the utilized method was presented. Through this, an information classification system based on inter-relationships can be developed beyond the one-way tree structure, which is a general construction information classification system, and effects such as shortening of construction period and cost reduction will be maximized.

Establishment and future tasks of estimated energy requirement in 2020 dietary reference intakes for Koreans (2020 한국인 에너지필요추정량 설정 및 앞으로의 과제)

  • Kim, Eun-Kyung;Kim, Oh Yoen;Park, Jonghoon;Kim, EunMi;Kim, Juhyeon
    • Journal of Nutrition and Health
    • /
    • v.54 no.6
    • /
    • pp.573-583
    • /
    • 2021
  • Energy requirement is defined as energy expenditure in an energy equilibrium state. The doubly labeled water (DLW) method is considered the gold standard for measuring total energy expenditure (TEE). In 2002, the Institute of Medicine (IOM) of the National Academies established dietary reference intakes (DRIs) for Americans and Canadians, and the equations for estimated energy requirement (EER) were developed by using pooled data from studies that had applied the DLW method. Since 2005, these equations have been used for establishing EER in the DRI for Koreans. These equations based on age group include the physical activity (PA) coefficient determined by the PA level (PAL; sedentary, low active, active and very active) as well as body weight and height. The PAL values of Koreans calculated using the DLW method and PA diaries were determined to fall in the low active category (1.40~1.59). Therefore, the PA coefficient corresponding to 'low active' was applied to the EER equations. In recent years, with increasing number of people regularly engaging in various physical activities in Korea, EER is now separately presented for people with 'active' and 'very active' PALs. In the future, like the United States and Japan, Korea needs to expand the DLW research for developing EER predictive equations for Koreans. In addition, standardized guidelines should be prepared to accurately evaluate the PAL using the physical activity diary and the new PA classification table for Koreans.

Radiographic, MRI and Histopathologic Assessment to Standardize Canine Spinal Cord Injury Model (척수손상 모델 견 표준화를 위한 방사선, 자기공명영상 및 조직 병리 평가)

  • Seong, Yun-Sang;Yun, Sung-Ho;Park, Jai-Soon;Kim, Hee-Kyung;Chang, Yong-Min;Ku, Sae-Kwang;Park, Hyun-Jeong;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.546-552
    • /
    • 2010
  • Previous studies could not offer available guideline to decide size of balloon and grade of injury before induction of spinal cord injury (SCI) because grade of SCI was assessed after inserting a catheter and each experimental animal were different in body size and weight as well as in species. This study was performed to provide guideline for standardized SCI model. Eight healthy adult beagle dogs that had 8 mm of spinal canal height were assigned to four groups according to the diameter of balloon and compression time: 4 mm/3hrs, 4 mm/6hrs, 4 mm/12hrs and 6 mm/3hrs group. Radiography was performed to standardize between experimental animal and balloon before selecting balloon diameter to induce SCI. Behaviors outcomes, somatosensory evoked potentials (SEPs), magnetic resonance imaging (MRI) and histopathological examination were evaluated. Behaviors outcomes and SEPs were not available to assess grade of SCI and those only indicate SCI. The damaged area was revealed clear hyperintensity on STIR image and T2WI after induction of SCI. The hyperintense area on MRI was cranially and caudally expanded with increasing of the diameter of balloon or the compression time. Well corresponded to expanding of hyperintense area on MRI, the damaged region and the numbers of caspase-3 and PARP immunoreactive cells were increased on histopathological findings. Therefore, these results will be considered fundamental data to induce standardized SCI model in experimental animal that has various weight and size.

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

The Clinical Usefulness of Cephalometric Analysis in the Obstructive Sleep Apnea Syndrome (폐쇄성 수면 무호흡 증후군에서 두개골계측분석의 임상적 유용성)

  • Choi, Young-Mee;Lee, Sang-Haak;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.2
    • /
    • pp.218-230
    • /
    • 1999
  • Background: Craniofacial anatomic abnormalities related to structural narrowing of the upper airway have been reported in patients with obstructive sleep apnea syndrome. In this study, we evaluated the craniofacial anatomic characteristics of Korean patients with obstructive sleep apnea syndrome, and the role of cephalometric analysis in the prediction of abnormal breathing during sleep. Methods: Thirty-nine patients with obstructive sleep apnea syndrome(OSAS), 39 simple snorers(simple snorers) and 20 controls(control) had cephalometric analysis using the technique of Riley et al, and underwent standardized polysomnographic recordings. Different variables, including sex, body mass index, cephalometric and polysomnographic data, were statistically analyzed. Results: Pm-UPW and V-LPW distances were significantly shorter in OSAS when compared with simple snorers or control. PAS in simple snorers was shorter than in control. ANS-Gn distance in OSAS was significantly longer than in control. PNS-P distance in OSAS or simple snorers was significantly longer than in control. MP-H distance in OSAS was significantly longer than in simple snorers or control and MP-H distance in simple snorers was also longer than in control. NL/Pm-P angle in OSAS was lesser than in control. MP-H distance in OSAS or in the combined groups of OSAS and simple snorers was significantly correlated with apneahypopnea index(AHI). PNS-P distance in the combined groups of OSAS and simple snorers was correlated with AHI. In male of all subjects, body mass index was significantly correlated with PNS-P or MP-H distance. Conclusion: Cephalometric analysis can be useful tool in determining the craniofacial anatomic abnormalities in patients with obstructive sleep apnea syndrome. Cephalometric parameters, especially MP-H distance, can be useful for predicting frequency of narrowing or obstruction of upper airway during sleep.

  • PDF

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

A Web-based Internet Program for Nutritional Assessment and Diet Prescription by Renal Diseases (웹기반의 신장질환별 영양평가 밑 식사처방 프로그램)

  • 한지숙;김종경;전영수
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.5
    • /
    • pp.847-885
    • /
    • 2002
  • The purpose of this study was to develop a web-based internet program for nutritional assessment and diet Prescription by renal diseases. Renal diseases were classified by nephrotic syndrome, renal failure, hemodialysis and peritoneal dialysis. The system consisted of five parts according to their functions and contents. The first part is to assess the general health status such as body weight, obesity index, basal metabolic rate and total energy requirement by the input of age, sex, height, weight and degree of activity. The second part was designed to investigate dietary history of patient, that is, to find out his inappropriate dietary habit and give him some suggestions for appropriate dietary behavior by investigating his dietary history. This part also offers the diet and nutrition management by personal status with renal disease, and the information for food selection, snacks, convenience foods, dine-out, behavioral modification, cooking methods, food exchange lists and terms. The third part is evaluating their energy and nutrients intake by comparing with recommended dietary allowance for Koreans or standardized data for patient with renal disease. In this part, it is also analyzing energy and nutrients of food consumed by food group and meals, and evaluating the status of nutrient intake. The fort]1 one, a major part of the system, is implementing the diet and menu planning by using food exchange lists. This Part Provides the patient with menus lists and I day menu suitable to his weight, activity and the status of renal disease. The fifth part is providing information on energy and nutrients of foods and drinks, and top 20 foods classified by nutrients. These results are finally displayed as tabular forms and graphical forms on the computer screen.