• Title/Summary/Keyword: Standard tone

Search Result 126, Processing Time 0.025 seconds

Audiogram in Response to Stimulation Delivered to Fluid Applied to the External Meatus

  • Geal-Dor, Miriam;Chordekar, Shai;Adelman, Cahtia;Kaufmann-Yehezkely, Michal;Sohmer, Haim
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.79-84
    • /
    • 2020
  • Background and Objectives: Hearing can be elicited in response to vibratory stimuli delivered to fluid in the external auditory meatus. To obtain a complete audiogram in subjects with normal hearing in response to pure tone vibratory stimuli delivered to fluid applied to the external meatus. Subjects and Methods: Pure tone vibratory stimuli in the audiometric range from 0.25 to 6.0 kHz were delivered to fluid applied to the external meatus of eight participants with normal hearing (15 dB or better) using a rod attached to a standard clinical bone vibrator. The fluid thresholds obtained were compared to the air conduction (AC), bone conduction (BC; mastoid), and soft tissue conduction (STC; neck) thresholds in the same subjects. Results: Fluid stimulation thresholds were obtained at every frequency in each subject. The fluid and STC (neck) audiograms sloped down at higher frequencies, while the AC and BC audiograms were flat. It is likely that the fluid stimulation audiograms did not involve AC mechanisms or even, possibly, osseous BC mechanisms. Conclusions: The thresholds elicited in response to the fluid in the meatus likely reflect a form of STC and may result from excitation of the inner ear by the vibrations induced in the fluid. The sloping fluid audiograms may reflect transmission pathways that are less effective at higher frequencies.

Audiogram in Response to Stimulation Delivered to Fluid Applied to the External Meatus

  • Geal-Dor, Miriam;Chordekar, Shai;Adelman, Cahtia;Kaufmann-Yehezkely, Michal;Sohmer, Haim
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.79-84
    • /
    • 2020
  • Background and Objectives: Hearing can be elicited in response to vibratory stimuli delivered to fluid in the external auditory meatus. To obtain a complete audiogram in subjects with normal hearing in response to pure tone vibratory stimuli delivered to fluid applied to the external meatus. Subjects and Methods: Pure tone vibratory stimuli in the audiometric range from 0.25 to 6.0 kHz were delivered to fluid applied to the external meatus of eight participants with normal hearing (15 dB or better) using a rod attached to a standard clinical bone vibrator. The fluid thresholds obtained were compared to the air conduction (AC), bone conduction (BC; mastoid), and soft tissue conduction (STC; neck) thresholds in the same subjects. Results: Fluid stimulation thresholds were obtained at every frequency in each subject. The fluid and STC (neck) audiograms sloped down at higher frequencies, while the AC and BC audiograms were flat. It is likely that the fluid stimulation audiograms did not involve AC mechanisms or even, possibly, osseous BC mechanisms. Conclusions: The thresholds elicited in response to the fluid in the meatus likely reflect a form of STC and may result from excitation of the inner ear by the vibrations induced in the fluid. The sloping fluid audiograms may reflect transmission pathways that are less effective at higher frequencies.

Flesh Tone Balance Algorithm for AWB of Facial Pictures (인물 사진을 위한 자동 톤 균형 알고리즘)

  • Bae, Tae-Wuk;Lee, Sung-Hak;Lee, Jung-Wook;Sohng, Kyu-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11C
    • /
    • pp.1040-1048
    • /
    • 2009
  • This paper proposes an auto flesh tone balance algorithm for the picture that is taken for people. General white balance algorithms bring neutral region into focus. But, other objects can be basis if its spectral reflectance is known. In this paper the basis for white balance is human face. For experiment, first, transfer characteristic of image sensor is analyzed and camera output RGB on average face chromaticity under standard illumination is calculated. Second, Output rate for the image is adjusted to make RGB rate for the face photo area taken under unknown illumination RGB rate that is already calculated. Input tri-stimulus XYZ can be calculated from camera output RGB by camera transfer matrix. And input tri-stimulus XYZ is transformed to standard color space (sRGB) using sRGB transfer matrix. For display, RGB data is encoded as eight-bit data after gamma correction. Algorithm is applied to average face color that is light skin color of Macbeth color chart and average color of various face colors that are actually measured.

Development of a V-Band Millimeter-Wave Source Module

  • Kwon, Jae-Yong;Lee, Dong-Joon;Bakti, Aditia Nur;Angin, Windi Kurnia Perangin
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.225-228
    • /
    • 2016
  • KRISS-V, a V-band millimeter-wave source module for a primary RF power standard and calibration system developed by the Korea Research Institute of Standards and Science is here presented. The output power of KRISS-V is several times higher than that of commercial amplifier/multiplier chains and is highly stable (the standard deviations of output power are less than 0.01% in the worst case). The spectral purity of KRISS-V is high enough to consider it a single-tone signal generator. We also added programmable attenuation capability to KRISS-V for remote power control. Moreover, the in-house source module is cost-effective and adaptable to various measurement schemes. The structure of the model as well as detailed component information are introduced so that it can be reproduced.

Introduction of a recent active loudspeaker measurement and assessment method based on IEC60268-21 (IEC60268-21 기반 최신 액티브 스피커 측정 및 분석 기법 소개)

  • LEE, Sinlyul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.241-246
    • /
    • 2021
  • Modern loudspeaker systems are changing an active loudspeaker system that have multiple input channels and power amplifier. So, we cannot measure these active loudspeakers with IEC 60268-5 standard. This paper introduces an IEC 60268-21 standard that can measure an active loudspeaker having many analog and digital and wireless or wired inputs and having various control parameters.

The study on the shade color change that depends on the kind of zirconia core and the porcelain thickness (지르코니아 코어의 종류와 도재 두께에 따른 색상의 변화)

  • Yeom, Mi-Ok;Lee, Jong-Hyuk;Shin, Soo-Yeon;Sin, Seung-Chul;Cho, Ja-Won
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.341-350
    • /
    • 2010
  • Purpose: This study focused on achieving desired shades by combining zirconia core with different thickness porcelain in order to make dental prostheses effectively. Methods: White and colored $LAVA^{TM}$ All Ceramic (3M-ESPE, Seefeld, Germany), and Zirkonzahn (Bruneck, Italy) Trans and prettau were used to have Zirconia. LAVATM Ceram (3M-ESPE, Germany) and ICE (Zirkonzahn, Italy) powder were used to have the porcelain. We made quadrilateral specimen of thickness 0.3mm, 0.5mm, 0.7mm and diameter 10 to use zirconia ceramics system of 2 kinds that color tone reappearance way is different and produced total 120 specimens to 4 experimental groups. We used Spectrophotometer to analyze color tone. Data's value getting by dispersal colorimetry period found L*, a*, b* value using Excel program. We used one-way ANOVA to use SPSS WIN 12.0 program. Results: All L*, a*, b* indexes of zirconia core and porcelain veneer in LAVA group and Zirkonzahn group were different. When you combine the white zirconia core of LAVA group with a porcelain veneer, the thickness of the porcelain must be more than 0.5mm to meet the standard target. When all the colored zirconia cores of LAVA group were combined with porcelain veneers, there was no significant difference from the standard target. When the zirconia cores of Zirkonzahn group are combined with porcelain veneers, the thinner thicknesses were closer to the standard tab than thicker thicknesses; however, there was a significant difference in all combinations, with Delta E* value indicating more than 3. Conclusion: When it comes to colored zirconia, which is the most popular, the thicknesses of both a core and a dentin veneer must be more than 0.3mm to get an appropriate shade. There is more possibility to get desirable shades when the thicknesses of a white core are thinner; however, they would be vulnerable to the environment and lose their color. When combine a zirconia core with a dentin veneer, using Zirkonzahn group needs more considerations in order to meet the standard target.

The Color Characteristics of Masculinity Presented in Modern Women's Suit - Focus on the Paris, London, New York and Milan Collections from 2004 F/W to 2006 F/W - (현대 여성 수트에 있어서 남성성(masculinity)을 나타내는 색채 특성 - 2004~2006년 F/W의 파리, 런던, 뉴욕, 밀라노 컬렉션을 중심으로 -)

  • Kwon, Ji-Hyun;Kim , Young-In
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.2
    • /
    • pp.62-77
    • /
    • 2008
  • This study aims to analyze color characteristics centered by women's suit styles that represent masculinity remarkably. Through this, it figures out color's type and continuance availability as a representing tool to express masculinity to provide useful color information which can be applied effectively to various color planning. For this research, related images were collected among women's pants suits appeared in $2004{\sim}2006's$ Paris, London, New York and Milan collection F/W that are most similar to modern man's suit. Among them, the study analyzes 319 pictures where the features of masculinity were represented effectively. The referred color values were earned by converting $L^*a^*b^*$ values measured through the color extracting tool of Computer program (Adobe Photoshop CS) and color tone characteristic were analyzed by classifying 12 color PCCS and 5 achromatic colors. The result of the study are as follows: First, based on standard of color hue and tone, in terms of color hue, PB, YR, Y were frequently shown up but G, BG series were not found much after analyzing overall women's pants suit color characteristics shown in $2004{\sim}2006$ Paris, London, New York and Milan collection. Second, the color analysis about 3years of $2004{\sim}2006$ tells that achromatic colors have been most widely used in every year. In terms of color hue, PB, YR, Y series were appeared most popular and G, BG classes weren't appeared frequently. In addition, once looking at yearly color tone distribution trend, like overall color tone distribution result, Bk, w, dkg, g, p were highly used as sequential and b, v, dp, sf, ItGy series show low distribution level. And such a distribution level of low and high in frequency has been showed continuously as a similar style. Accordingly, through the study, as a tool to express masculinity in women's suit, achromatic colors like black and white series and PB, YR, Y series color were investigated as most popular uses. And as color tones, Bk, w, dkg, g, p were used frequently.

Digitization of Adjectives that Describe Facial Complexion to Evaluate Various Expressions of Skin Tone in Korean (피부색을 표현하는 형용사들의 수치화를 통한 안색 평가법 연구)

  • Lee, Sun Hwa;Lee, Jung Ah;Park, Sun Mi;Kim, Younghee;Jang, Yoon Jung;Kim, Bora;Kim, Nam Soo;Moon, Tae Kee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.4
    • /
    • pp.349-355
    • /
    • 2017
  • Skin tone plays a key role in one of the determinant for facial attractiveness. Most female customers have an interest in choosing skin color and improving their skin tone and their needs have been contributed the expansion of cosmetic products in the market. Recently, cosmetic customers, who want bright skin, are also interested in healthy and lively-looking skin. However, there is no method to evaluate the skin tone with the complexion-describing adjectives (CDAs). Therefore, this study was conducted to find the ways to objectify and digitize the CDA. We obtained that quasi $L^*$ at dark skin is 65 and quasi $L^*$ at bright skin is 74 for standard images, which are selected from our data base. To match the following seven CDAs: pale, clear, radiant, lively, healthy, rosy and dull, the colors of both images were adjusted by 30 panels. The quasi $L^*$, $a^*$ and $b^*$ were converted from the RGB values of the manipulated images. The differences between the quasi $L^*$, $a^*$ and $b^*$ values of standard images and manipulated images reflecting each CDA were statistically significant (p < 0.05). However, there were no statistical significances between the $L^*$ values of dark and bright skin images that were modified in accordance with each CDA and there also were no statistical significances between the quasi $a^*$ values of dark and bright skin for pale and clear CDAs. From the statistical analysis, the CDAs were observed to form three groups: (i) pale-clear-radiant, (ii) lively-healthy-rosy and (iii) dull. We recognized that people have a similar opinion about perception of CDAs. Following our results of this study, we establish new standard method for sensibility evaluation which is difficult to carry out scientifically or objectively.

Detection and Analysis of Event-Related Potential P300 in EEG by 4-Stimulus Oddball Paradigm

  • Jang, Yun-Seok;Ryu, Soo-Ah;Park, Kyu-Chil
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.2
    • /
    • pp.234-237
    • /
    • 2010
  • P300 component of the event-related potential(ERP) has been studied for theoretical, empirical, and clinical applications. Nowadays the 1-, 2-, and 3-stimulus oddball paradigms are used for eliciting P300 component of EEG in the auditory stimulus experiments. In this paper, we used a method to add one more stimulus to the 3-stimulus auditory paradigm. The adding stimulus has not the same volume but the same tone of the target stimulus. The 4-stimulus oddball paradigm to use two targets is used to elicit the P300 event-related potentials. In 4-stimulus oddball paradigm, an infrequent non-target (p=0.10) is presented in addition to two infrequent targets (p=0.10) and a frequent standard (p=0.70). Two target stimuli elicited a P300 component with a parietal maximum distribution. The amplitude of the P300 in target 2 was larger than that in target 1 and the latency of the P300 in target 2 was longer than that in target 1. The P300 component due to target 2 stimuli was larger than that due to target 1 stimuli. The experimental results approve that the 4-stimulus oddball paradigm can elicit P300 component clearly. The results are compared with the results of the traditional oddball paradigm.

Study on CMS Application in Hybrid UV Waterless Off-Set Printing (H-UV 무습수 오프셋 인쇄에서 CMS 적용에 관한 연구)

  • Koo, Chul-Whoi;Cho, Ga-Ram
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.5
    • /
    • pp.1-13
    • /
    • 2013
  • This study found fit optimum C, M, Y, K solid density and $CIEL^*a^*b^*$ value to paper & ink as well as check about printing machine state for color management in H-UV waterless off-set printing first. These values applied to GRACoL G7 calibration method. This method is one of color standard management method of printing. GRACoL G7 calibration method is possible stable tone reappearance by controlling gray balance by NPDC(Natural Printing Density Curve). Also, this study used values to make device profile as result that is gotten by application of GRACoL G7 calibration method. This profile was applied to CMS(Color Management System) of H-UV waterless off-set printing, and the result was possible by color management that correspond in printing quality standard of ISO 12647-2 and GRACol 2006 specifications.