• Title/Summary/Keyword: Standard technology

Search Result 10,275, Processing Time 0.037 seconds

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

Report for Development of Korean Portable Cardiopulmonary Bypass Machine (한국형 이동식 심폐소생기 개발 보고 I. 실험견을 이용한 개흉식과 폐쇄식 심폐소생술 비교)

  • Kim, Hyoung-Mook;Lee, In-Sung;Baek, Man-Jong;Sun, Kyung;Kim, Kwang-Taik;Kim, Yeon-Soo;Kim, Maeng-Ho;Lee, Hye-Won;Lee, Kyu-Back;Kim, Hark-Jei
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.827-836
    • /
    • 1998
  • Background: Effective cardiopulmonary resuscitation (CPR) should provide acceptable hemodynamics for the vital organs during cardiac arrest and early restoration of spontaneous circulation that guarantees long-term, neurologically intact survival. CPR using heart-lung bypass has been suggested as an option for that use. This study was designed to determine the effectiveness of standard CPR techniques, closed-vs. open-chest CPR, which could be used in the future study verifying the role of heart-lung bypass CPR. Material and Method: By using adult mongrel dogs, closed-chest CPR (CCCPR, n=4) and open-chest CPR (OCCPR, n=5) were compared with respects to hemodynamics, restoration of spontaneous circulation(ROSC), and survival. Ventricular fibrillation-cardiac arrest (VF-CA) was induced by electrical shock in all animals. After 4 minutes of cardiac arrest, basic life support (BLS) was applied for 15 minutes and followed by advanced life support (ALS). ALS was maintained until achi ving ROSC but not longer than 30 minutes regardless of the recovery. Resuscitation procedures in either group were standardized by adopting the protocol of American Heart Association. Result: Prearrest baseline hemodynamic data was not different between two groups. During resuscitation, substantially higher systolic pressure was maintained in OCCPR group than in CCCPR group (45$\pm$15 vs. 33$\pm$11 mmHg during BLS, 83$\pm$36 vs. 44$\pm$15 mmHg during ALS; p=NS). Mean pulmonary arterial pressure went up to the level of mean systemic arterial pressures in CCCPR group and to half of that in OCCPR group, and had kept higher in CCCPR group throughout CPR (32$\pm$10 vs. 22$\pm$4 mmHg during BLS and 32$\pm$15 vs. 24$\pm$10 mmHg during ALS; p=NS). ROSC was obtained in 4 of 5 dogs receiving open-chest CPR and 2 of 4 closed-chest CPR. Prolonged survival was noted in all dogs in OCCPR group (6 to 1440 hours) but not in CCPR group (p<.05). Conclusion: These findings indicate that open-chest CPR can be more effective t maintain hemodynamics during cardiac arrest and to obtain restoration of spontaneous circulation and survival. Further experiment will be designed to compare heart-lung bypass CPR with open-chest CPR.

  • PDF

Effect of Application Time and Rate of Mixed Expeller Cake on Soil Environment and Rice Quality (혼합유박 시용량 및 시용시기가 토양환경과 미질에 미치는 영향)

  • Yang, Chang-Hyu;Yoo, Chul-Hyun;Kim, Byeong-Su;Park, Woo-Kyun;Kim, Jae-Duk;Jung, Kwang-Yong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.2
    • /
    • pp.103-111
    • /
    • 2008
  • This study was carried out to investigate the optimal application rate and time of mixed expeller cake (MEC) for the replacement of chemical fertilizer. Dongjin-1, as cultivated rice was used at Fluvio-marine deposit in Honam plain paddy field. Soil chemical properties were improved by the application of MEC. Contents of total nitrogen and organic matter were higher in 70%, 100% plots of basal dressing than standard fertilizer application (SFA) plot. Cation exchangeable capacity was highly increased in 70% plot of basal dressing. Also, the content of organic matter in soil was increased with MEC application. Cation exchangeable capacity, total nitrogen and available phosphate were decreased according to late application time. The content of inorganic nitrogen in soil showed high tendency at more application rate of MEC, and nitrogen mineralization at harvest season have finished in 50%, 70% plots of basal dressing. The content of inorganic nitrogen in soil was increased according to late application time, however it was decreased in the late period of growth. Leaf color value became darker with increased application rate of MEC. Leaf color was dark green in MEC application plots at panicle formation stage, on the other hand, it was light green in 50%, 70% plots of basal dressing at heading stage. SPAD reading value of leaf-color was high during the whole growth stage in MEC application plots. More application rate of MEC showed higher tendency of fertilizer nitrogen absorption. Nitrogen use efficiency was the highest in 70% plot of basal dressing. Absorbed amount of fertilized nitrogen was increased in 10~15days before transplanting and nitrogen use efficiency was high according to the late application time. The ratio of perfect kernel and the content of protein on hulled rice showed high tendency at the less application rate of MEC. The ratio of head rice on milled rice showed high tendency at the less application rate of MEC. Rice yield increased 4% in 100% and 70% plots of basal dressing compare with SFA ($5.18Mg\;ha^{-1}$) plot respectively. Ear and culm length of rice were long according to the late application time, while the numbers of spikelet and ear were increased and the percentage of ripened grain was decreased. Rice yield was increased 2~5% in all MEC application plots compared to SFA plot and especially, increased 10~15days before transplanting in application plots. The optimal application rate and time of MEC on normal paddy field in plain were concluded that 70% basal dressing and 10~15days before transplanting

Effect of Topophysis and Uniting Method of Rootstock and Scion on Rooting and Subsequent Growth of Stenting-propagated (Cutting-grafted) Roses (접수의 채취부위 및 접수와 대목의 고정법에 따른 장미 접삽묘의 생육 특성)

  • Park, Yoo-Gyeong;Jeong, Byoung-Ryong
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.456-461
    • /
    • 2010
  • A study was conducted to investigate the effect of topophysis, and uniting method of rootstock and scion on rooting and subsequent growth of stenting-propagated cut rose ($Rosa$ $hybrida$ Hort.) in an effort to develop an efficient stenting propagation method for domestic rose cultivars. Four cultivars used in this study were two standard type cultivars 'Sweet Yellow' and 'Hanmaum', and two spray type cultivars 'Chelsi' and 'May'. Scions were grafted on cuttings of a rootstock $Rosa$ $indica$ 'Major'. The stenting-propagated scion-rootstock unions were planted in rockwool cubes ($50{\times}50{\times}50mm$, Delta, Grodan, Denmark) and were placed in a graft-take chamber for five days before being placed on misted greenhouse beds. The rootstock was removed of all leaves and nodes. Both the base of scions and top of stocks were simultaneously cut at a $45^{\circ}$ angle for grafting. Scions were prepared as single node cuttings, each with a five-leaflet leaf. Three positions of topophysis used were 7-9th (top), 4-6th (middle), and 1st-3rd (bottom) nodes from the stem base. Four uniting materials used were tube, tube + parafilm wrap, tube + clothespin, and clothespin. Rooting and growth were affected by the topophysis and cultivar. The best topophysis for rooting was 7-9th (top) nodes in all cultivars. Topophysis affected percent rooting, and number of roots, length of the longest root, and but not weight, shoot length and graft-take. Rooting and growth were affected by the uniting method and cultivar. Tube uniting method generally showed higher percentage graft-take, percent rooting, and number of roots than other methods. However, rootstock and scion union was not complete in this treatment. On the whole, the greatest rooting and subsequent growth of stenting-propagated plants were found in the tube + clothespin method. Except 'Sweet Yellow', rooting and growth were not adequate in the clothespin method. The results suggested that a tube + clothespin method was the most effective, and this method may be used as a substitute to save labor compared to a tube + parafilm wrap method which is currently being used in commercial nurseries.

Development of Agrobacterium-mediated Transformation Method for Domestically Bred Chrysanthemum Cultivar 'Moulinrouge' and Genetic Change of Leaf Morphology Using AtSICKLE Gene (아그로박테리움를 이용한 국내개발 국화품종 '무랑루즈'의 형질전환 기술 및 AtSICKLE 유전자를 이용한 엽형 변화 국화 형질전환체 개발)

  • Kim, Yun-Hye;Park, Hyun-Myung;Jung, Ji-Yong;Kwon, Tack-Min;Jeung, Soon-Jae;Yi, Young-Byung;Kim, Gyung-Tae;Nam, Jae-Sung
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.449-455
    • /
    • 2010
  • 'Moulinrouge' was selected as the best regenerating cultivar among 18 different spray-type chrysanthemum cultivars bred in the Gyeongnam Flowers Breeding Research Institute. When the leaf explants from standard- and spray-type chrysanthemum 'Jinba' and 'Moulinrouge' were incubated on MS basal medium supplemented with $0.5mg{\cdot}L^{-1}$ BA and $1.0mg{\cdot}L^{-1}$ NAA, both 'Jinba' and 'Moulinrouge' induced adventitious shoots that can be regenerated into plantlets. Based on these regeneration conditions, we developed an efficient $Agrobacterium$-mediated chrysanthemum 'Moulinrouge' transformation method by using sequential selection of shoots from low ($10mg{\cdot}L^{-1}$) to high ($30mg{\cdot}L^{-1}$) concentrations of kanamycin after co-cultivation of leaf explants with $Agrobacterium$ for 10 days and induction of shoots. All kanamycin resistant plants investigated with genomic PCR analysis carried the report gene, $AtSICKLE$, in their genome. Although expression levels of the report gene in the transgenic plants investigated with RT-PCR were relatively low because of inefficiency of CaMV 35S promoter in chrysanthemum, transgenic lines expressing $AtSICKLE$ efficiently showed leaf epinasty phenotype. We expect that our results will provide a useful method that can perform a high-throughput investigation of genes isolated and studied well in model plants for molecular breeding of chrysanthemum.

Development of an Automatic Liquid Feeder for Early Weaned Piglets (조기이유 자돈용 액상사료 자동급이기 개발)

  • 유용희;정일병;안정대;이덕수;강희설;최희철;전병수;박홍석
    • Journal of Animal Environmental Science
    • /
    • v.7 no.1
    • /
    • pp.1-12
    • /
    • 2001
  • This study was conducted to develope an automatic liquid feeder for early weaning piglets and to test the efficacy of the system. The liquid feeder consists of water heating and discharge unit, dry diet storing and discharge unit, mixing and discharge unit, mixed liquid feed-delivering unit, and the central control part which control each unit, feeding frequency and the amount of feeding. For investigating the possibility of practical use, a feeding trial was carried out using eighteen three way crossbred piglets weaned on 19 days of age for the experimental period of six weeks. Experimental diet was provided in liquid form using the automatic liquid feeder for the first three weeks and in dry form for the later three weeks. The water heating and discharge unit exactly supplied warm water by 27 $m\ell$/s, into the mixing unit. The dry diet storing and discharge unit supplied dry feed by 3.7g/s, into the mixing unit. Being compared with the standard growth rate suggested by NRC, average daily gain of the piglets during the first three weeks of liquid feeding was lower by 10%, while it was higher during three weeks of dry feeding and over the whole experimental period by 24 and 17%, respectively. Feed/gain was 1.09, 2.14 and 1.89 for the first 3 weeks, later 3 weeks, and whole period, respectively. Diarrhea was observed for three days from day 3 to day 7 after feeding liquid diet, but no pig died of it. In conclusion, a preliminary test for the newly developed an automatic liquid feeder using 19 days of age weaning piglets showed that the unit was successfully operated without any major problems. Piglets raised on a liquid diet through the unit developed grew less during the first three weeks, but their growth and feed intake were greatly improved thereafter, indicating the developed automatic liquid feeder may be practically used in swine industry.

  • PDF

The Effect of the Addition of Carbohydrate Sources on the Concentration of Odorous Compounds for Recycling of Pig Slurry to Grassland (발효탄수화물 첨가 비육돈사료가 초지환원용 슬러리의 악취물질 농도에 미치는 영향)

  • Cho, Sung Back;Hwang, Ok Hwa;Park, Kyu Hyeun;Choi, Dong Yun;Yang, Seung Bong;Kim, Do Hwan;Park, Sung Kwon
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.33 no.4
    • /
    • pp.257-262
    • /
    • 2013
  • This study investigates the effect of fermentable carbohydrate on the concentration of odorous compounds in pig slurry. Four types of pig diet were studied: control, peanut hull (crude fiber 29.87, NDF 44.02%), golden fiber (crude fiber 48.77, NDF 65.88%), and almond hull (crude fiber 44.30, NDF 64.44%). Pigs (average BW 37.0 kg) were fed diets that met the Korean Feeding Standard (2012) and their excreta samples were collected from the slurry pits. Levels of volatile organic compounds (phenols and indoles) and volatile fatty acids were analyzed by gas chromatography. Phenol level was the lowest (p<0.05) in golden fiber (33.26 ppm) group and the highest in control (97.29 ppm). The concentration of indoles in the peanut hull (1.27 ppm), almond hull (1.20 ppm), and golden fiber (1.02 ppm) groups was lower (p < 0.05) than that of control (1.79 ppm). Levels of short chain fatty acid (SCFA) were lower (p < 0.05) in golden fiber (1,319 ppm) and almond hull (1,433 ppm) groups than in control (1,893 ppm). Concentration of branched chain fatty acid (BCFA) in the golden fiber group (74 ppm) was lower (p < 0.05) than that of control (98 ppm). Taken together, the concentration levels of phenols, indoles, and VFAs decreased on addition of peanut hull, golden fiber or almond hull to the diet, suggesting that fermentable carbohydrate may contribute to reducing odorous compounds in pig slurry.

Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange (온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.647-657
    • /
    • 2015
  • To investigate a method for calculation of the heating load for environmental designs of horticultural facilities, measurements of total heating load, infiltration rate, and floor heat flux in a large-scale plastic greenhouse were analyzed comparatively with the calculation results. Effects of ground heat exchange and infiltration loss on the greenhouse heating load were examined. The ranges of the indoor and outdoor temperatures were $13.3{\pm}1.2^{\circ}C$ and $-9.4{\sim}+7.2^{\circ}C$ respectively during the experimental period. It was confirmed that the outdoor temperatures were valid in the range of the design temperatures for the greenhouse heating design in Korea. Average infiltration rate of the experimental greenhouse measured by a gas tracer method was $0.245h^{-1}$. Applying a constant ventilation heat transfer coefficient to the covering area of the greenhouse was found to have a methodological problem in the case of various sizes of greenhouses. Thus, it was considered that the method of using the volume and the infiltration rate of greenhouses was reasonable for the infiltration loss. Floor heat flux measured in the center of the greenhouse tended to increase toward negative slightly according to the differences between indoor and outdoor temperature. By contrast, floor heat flux measured at the side of the greenhouse tended to increase greatly into plus according to the temperature differences. Based on the measured results, a new calculation method for ground heat exchange was developed by adopting the concept of heat loss through the perimeter of greenhouses. The developed method coincided closely with the experimental result. Average transmission heat loss was shown to be directly proportional to the differences between indoor and outdoor temperature, but the average overall heat transfer coefficient tended to decrease. Thus, in calculating the transmission heat loss, the overall heat transfer coefficient must be selected based on design conditions. The overall heat transfer coefficient of the experimental greenhouse averaged $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$, which represents a 60% heat savings rate compared with plastic greenhouses with a single covering. The total heating load included, transmission heat loss of 84.7~95.4%, infiltration loss of 4.4~9.5%, and ground heat exchange of -0.2~+6.3%. The transmission heat loss accounted for larger proportions in groups with low differences between indoor and outdoor temperature, whereas infiltration heat loss played the larger role in groups with high temperature differences. Ground heat exchange could either heighten or lessen the heating load, depending on the difference between indoor and outdoor temperature. Therefore, the selection of a reference temperature difference is important. Since infiltration loss takes on greater importance than ground heat exchange, measures for lessening the infiltration loss are required to conserve energy.

Vitamin B5 and B6 Contents in Fresh Materials and after Parboiling Treatment in Harvested Vegetables (채소류의 수확 후 원재료 및 데침 처리에 의한 비타민 B5 및 B6 함량 변화)

  • Kim, Gi-Ppeum;Ahn, Kyung-Geun;Kim, Gyeong-Ha;Hwang, Young-Sun;Kang, In-Kyu;Choi, Youngmin;Kim, Haeng-Ran;Choung, Myoung-Gun
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.172-182
    • /
    • 2016
  • This study was aimed to determine the changes in vitamin $B_5$ and $B_6$ contents compared to fresh materials after parboiling treatment of the main vegetables consumed in Korea. The specificity of accuracy and precision for vitamin $B_5$ and $B_6$ analysis method were validated using high-performance liquid chromatography (HPLC). The recovery rate of standard reference material (SRM) was excellent, and all analysis was under the control line based on the quality control chart for vitamin $B_5$ and $B_6$. The Z-score for vitamin $B_6$ in food analysis performance assessment scheme (FAPAS) proficiency test was -1.0, confirming reliability of analytical performance. The vitamin $B_5$ and $B_6$ contents in a total of 39 fresh materials and parboiled samples were analyzed. The contents of vitamin $B_5$ and $B_6$ ranged from 0.000 to 2.462 and from 0.000 to $0.127mg{\cdot}100g^{-1}$, respectively. The highest contents of vitamin $B_5$ and $B_6$ were $2.462mg{\cdot}100g^{-1}$ in fresh fatsia shoots (stem vegetables), and $0.127mg{\cdot}100g^{-1}$ in fresh spinach beet (leafy vegetables), respectively. Moreover, the vitamin $B_5$ and $B_6$ contents for parboiling treatment in most vegetables were reduced or not detected. In particular, the contents of vitamin $B_5$ in parboiled fatsia shoots and vitamin $B_6$ in parboiled yellow potato and spinach beet were decreased 20- and 4-fold compared with fresh material, respectively. These results can be used as important basic data for utilization and processing of various vegetable crops, information for dietary life, management of school meals, and national health for Koreans.