• Title/Summary/Keyword: Standard section

Search Result 887, Processing Time 0.025 seconds

The Voice Dialing System Using Dynamic Hidden Markov Models and Lexical Analysis (DHMM과 어휘해석을 이용한 Voice dialing 시스템)

  • 최성호;이강성;김순협
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.7
    • /
    • pp.548-556
    • /
    • 1991
  • In this paper, Korean spoken continuous digits are ercognized using DHMM(Dynamic Hidden Markov Model) and lexical analysis to provide the base of developing voice dialing system. After segmentation by phoneme unit, it is recognized. This system can be divided into the segmentation section, the design of standard speech section, the recognition section, and the lexical analysis section. In the segmentation section, it is segmented using the ZCR, O order LPC cepstrum, and Ai, parameter of voice speech dectaction, which is changed according to time. In the standard speech design section, 19 phonemes or syllables are trained by DHMM and designed as a standard speech. In the recognition section, phomeme stream are recognized by the Viterbi algorithm.In the lexical decoder section, finally recognized continuous digits are outputed. This experiment shiwed the recognition rate of 85.1% using data spoken 7 times of 21 classes of 7 continuous digits which are combinated all of the occurence, spoken by 10 man.

  • PDF

An evaluation of stream naturalness for Close-to-nature stream restoration -In case of Suwon stream- (자연형 하천복원을 위한 하천자연도 평가 -수원천을 중심으로-)

  • Kim, Dong-Chan;Lee, Jung;Park, Il-Su
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.5
    • /
    • pp.138-149
    • /
    • 2000
  • The purpose of this study is to evaluate Suwon stream naturalness Index(S.N.I). and tofind out stats, problems and opportunities of the Suwon stream by assessment standard. Assessment standard is mainly based on physical structure of stream environment. the purpose evaluating sectors and elements are physical form and structure restoration of stream. To find out assessment standard of stream naturalness index, conceptual frame of assessment standard has been established, for which four sections, for example, longitudinal section, lateral section, stream bottom structure and water environment, have been selected. Overall stream naturalness index of the Suwon stream has been distributed at 3rd to 4th grade, and 3.3 of assessment index and mode were 3rd grade respectively. stream naturalness index of each section was as follows: Longitudinal section accounted for 3.7in average to be 4th grade, lateral section did 3.8 to be 4th grade, and water environment did 2.4 to be 2nd grade. Analysis of assessment outcome of stream naturalness index has checked status, problems and opportunities of corresponding stream. Assessment of stream naturalness index of the study provides useful information for restoration of close-to-nature stream, and furthermore has its meaning in checking problems and opportunities of Suwon stream.

  • PDF

Optimization of Prestressed Concrete Beam Section (프리스트레스트 콘크리트 보 단면의 최적설계)

  • 조선규;최외호
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.91-101
    • /
    • 2000
  • As the computer related technology evolves a study for a practical use of real structure as well as its hteory for optimum design has been greatly advanced. But the study on optimum design of pre-stressed concrete beam(PSC-beam) bridge for the construction of national roads and highways in Korea is not sufficient. Since a standard section for the PSC-beam is proposed, it is practically used in designing the PSC-beam. It is noticed that the section using the current standard PSC-beam design to be an over-designed with its surplus safety factor. Therefore, it is necessary to consider economical PSC-beam section which automatically satisfies all requirement of design specifications. Thus, in this study, the optimum design methods of PSC-beam are carried out using the gradient-based search method and global search method. As a result of the optimum design method, it was confirmed that the design of PSC-beam has a serious properties to non-linearity and discontinuity. And the section that in economical and efficinet design methods than the current standard design method is proposed.

A Study on the Application of Facility Standard of Rural Public Health Center to city Public Health Center with a Focus on Area Ratio (면적구성을 중심으로 한 농어촌 보건소 표준시설 기준의 도시 보건소 적용에 관한 연구 - 대구광역시 보건소를 중심으로 -)

  • 이용광
    • Korean Institute of Interior Design Journal
    • /
    • no.40
    • /
    • pp.102-108
    • /
    • 2003
  • Currently, there is no facility standard for a city public health center. The facility standard of rural public health center is referred to architectural plan of city public health center. This study is about architectural plan of the city public health center and have been in 7 public health centers in Daegu investigated. Conclusions can be summarized as follows: 1) The Mother and child hygienic section, area ratio which is presented by the facility standard of rural public health center must be increased in case of city public health center since function-reinforcement of the mother and child hygienic section is required. 2) Business section, the area ratio which is presented by the facility standard of rural public health center must be diminished for city public health center because it has been excessively allocated.

Integrated Code Classification System for Work Sections in Standard Method of Measurement and Construction Standard Specifications (수량산출기준 및 공사시방서의 공종분류코드 통합기준 연구)

  • Kang Leen-Seok;Kwak Joong-Min
    • Korean Journal of Construction Engineering and Management
    • /
    • v.2 no.4 s.8
    • /
    • pp.80-91
    • /
    • 2001
  • Considering that the classified items in the work section level can have an applicability when those items are being used to cost and specification information with consistency, the work section classification code should be applied as an Integrated code system. Our construction industry is using three work section classification systems for civil engineering projects, such as integrated construction information classification system, standard method of measurement and guide of project specification. And each standard construction specification is also using different work section classification systems. This study suggests a methodology to integrate the code systems in construction specifications with civil engineering standard method of measurement. And the methodology suggested in this study was applied to a web-based prototype system with practical specification codes.

  • PDF

Development of a Junction between Airport Concrete and Asphalt Pavements (공항 콘크리트와 아스팔트 포장 간의 접속 방법 개발)

  • Park, Hae Won;Kim, Dong Hyuk;Jeong, Jin Hoon
    • International Journal of Highway Engineering
    • /
    • v.20 no.4
    • /
    • pp.15-20
    • /
    • 2018
  • PURPOSES : The purpose of this study is to analyze the magnitude of shoving of asphalt pavement by junction type between airport concrete and asphalt pavements, and to suggest a junction type to reduce shoving. METHODS : The actual pavement junction of a domestic airport, which is called airport "A" was modified by placing the bottom of the buried slab on the top surface of the subbase. A finite element model was developed that simulated three junction types: a standard section of junction proposed by the FAA (Federal Aviation Administration), an actual section of junction from airport "A" and a modified section of junction from airport "A". The vertical displacement of the asphalt surface caused by the horizontal displacement of the concrete pavement was investigated in the three types of junction. RESULTS : A vertical displacement of approximately 13 mm occurred for the FAA standard section under horizontal pushing of 100 mm, and a vertical displacement of approximately 55 mm occurred for the actual section of airport "A" under the same level of pushing. On the other hand, for the modified section from airport "A" a vertical displacement of approximately 17 mm occurred under the same level of pushing, which is slightly larger than the vertical displacement of the FAA standard section. CONCLUSIONS : It was confirmed that shoving of the asphalt pavement at the junction could be reduced by placing the bottom of the buried slab on the top surface of the subbase. It was also determined that the junction type suggested in this study was more advantageous than the FAA standard section because it resists faulting by the buried slab that is connected to the concrete pavement. Faulting of the junctions caused by aircraft loading will be compared by performing finite element analysis in the following study.

Optimization of Bumper Beam Section of Crashworthiness (충돌성능을 고려한 승용차 범퍼빔 단면의 최적화)

  • Kang, S.J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.276-284
    • /
    • 1998
  • Optimum design of bumper beam is investigated using nonlinear CAE structural analysis techniques.In order to minimize its weight, while enhancing structural performances, bumper beam structural analyses were carried out to produce optimum section. Model is composed of bumper beam and stay. First, considering FMVSS safety standard, static strength and energy absorbing capability were estimated for several competitive bumpers through pendulum static analysis, and most promising section was chosen. Next, to ensure dynamic crashworthinesss performance for center pole impact was evaluated for the bumper beam with chosen section through pendulum static analysis, referring to DHS bumper dynamic impact standard. Finally, 2.5 mph bumper beam was designed and its structural performance was estimated. Through this investigation, an optimized bumper beam section with less weight of 20% while maintaining almost equal carshworthiness, compared with a conventional bumper beam section which proved its impact crashworthiness by experiments, was developed.

  • PDF

A Study on Economical Efficiency Evaluation of Semiforcing under Structure Watermelon Cultivators (반촉성 시설수박 재배농가의 경제적 효율성 분석)

  • Kim, Woong;Kim, Jai Hong
    • Korean Journal of Agricultural Science
    • /
    • v.33 no.2
    • /
    • pp.179-193
    • /
    • 2006
  • Technical efficiency of semiforcing watermelon growers is 0.8248 on average, and distributed between 0.6744 and 0.9268. The result showed that semiforcing watermelon growers had by 18% of technical inefficiency and could be assumed that increasing technical efficiency could induce watermelon production more increase. Consequently, if growers' technical efficiency were improved while other environments were constant, watermelon production could be increased. Following the results from the inefficiency effect model, all assumption coefficient such as growers age etc, are significant at 10% level. Estimate of dispersion parameter ${\gamma}$ is 0.89, which confirms those differences between practical output and frontier output were derived from the technical efficiencies among growers. Differences of production system between high and low level growers in production efficiency were showed at side altitude, ventilation and heat-retaining in section of facilities and automation, soil test and calcium application in section of environment management, transplant preparation and duration of pollination in section of crop management and shipment place, sorting degree and management record analysis in section of business management respectively. As a result of analyzing consulting data by using standard diagnosis table of watermelon cultivation under structure which cultivated on semi-forced watermelon growers, gap between high and low level growers was 7.0 points in facility automation section, 7.1 points in environment section, 8.8 points in crop management section and 13.6 points in business management section, respectively, which were the biggest one among them. In case of excluding information-related items from the evaluation index of business management section, changes of business achievement are to occur. Therefore, it is recommended for us to review the standard diagnostic table of watermelon cultivation under structure by dividing evaluation index of management section into management and information.

  • PDF

An evaluation of stream naturalness for Close-to-nature stream restoration in case of Hakui Stream (학의천을 중심으로 본 자연형 하천복원을 위한 하천자연도 평가)

  • Kim, Dong-Chan;Yoon, Young-Seok;Park, Ik-Su
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.4
    • /
    • pp.315-324
    • /
    • 2003
  • The purpose of this is to evaluate Hakui Stream Naturalness Index(S.N.I). and to find out stats, problems and opportunities of the Hakui stream by assessment standard. Assessment standard is mainly based on physical structure of stream environment. The purpose evaluating sectors and elements are physical form and structure restoration of stream. To find out assessment standard of stream naturalness index, conceptual frame of assessment standard has been established, for which four sections, for example, longitudinal section, lateral section, stream bottom structure and water environment, have been selected. Overall stream naturalness index of the Hakui stream has been distributed at 3rd to 4th grade, and its assessment index accounted for 3.2 to be 3rd grade, and its mode also did 3rd grade. Stream naturalness index of each section was as follows: Longitudinal section index accounted for 3.6 in average to be 4th grade, and later section index did 3.0 to be 3rd grade, and stream bottom structure index did 3.0 to be 3rd grade, and water environment index did 2.7 to be 3rd grade. Analysis of assessment outcome of stream naturalness index has checked status, Problems and opportunities of corresponding stream. Assessment of stream naturalness index of the study provides useful information for restoration of close-to-nature stream, and furthermore has its meaning in checking problems and opportunities of Hakui stream.

  • PDF

Analytical method to estimate cross-section stress profiles for reactor vessel nozzle corners under internal pressure

  • Oh, Changsik;Lee, Sangmin;Jhung, Myung Jo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.401-413
    • /
    • 2022
  • This paper provides a simple method by which to estimate the cross-section stress profiles for nozzles designed according to ASME Code Section III. Further, this method validates the effectiveness of earlier work performed by the authors on standard nozzles. The method requires only the geometric information of the pressure vessel and the attached nozzle. A PWR direct vessel injection nozzle, a PWR outlet nozzle, a PWR inlet nozzle and a BWR recirculation outlet nozzle are selected based on their corresponding specific designs, e.g., a varying nozzle radius, a varying nozzle thickness and an outlet nozzle boss. A cross-section stress profile comparison shows that the estimates are in good agreement with the finite element analysis results. Differences in stress intensity factors calculated in accordance with ASME BPVC Section XI Appendix G are discussed. In addition, a change in the dimensions of an alternate nozzle design relative to the standard values is discussed, focusing on the stress concentration factors of the nozzle inside corner.