• Title/Summary/Keyword: Standard sample

Search Result 2,190, Processing Time 0.032 seconds

Development of Multi-sample Loading Device for TEM Characterization of Hydroxyapatite Nanopowder

  • Lee, Jong-Moon;Kim, Jung-Kyun;Jeong, Jong-Man;Kim, Jin-Gyu;Lee, Eunji;Kim, Youn-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.788-792
    • /
    • 2013
  • A shortcoming of using transmission electron microscopy (TEM) for structural analysis via electron diffraction is the relatively large error of the measurements as compared to X-ray diffraction. To reduce these errors, various internal standard methods from earlier studies have been widely used. We developed a new device to facilitate the application of internal standard methods in preparation of TEM grids used for nanopowder analysis. Through the application of a partial mask on the TEM grid, both the internal standards and the research materials can be loaded on the same grid. Through this process, we conducted a TEM analysis that compared synthetic hydroxyapatite (HAp) nanopowder to bone apatite from a bovine femur. We determined that the accuracy of the d-spacing measurements of the HAp and bone powders could be improved to better than 1% after statistical treatments of the experimental data. By applying a quarter mask, we loaded four different nanoparticles on a single TEM grid, with one section designated for the internal standard.

Relationships among various factors used in calculating control limits of control chart for variable data (계량형 관리도의 관리규격 계산에 사용되는 여러 계수값 사이의 관계)

  • 박성균;김영균
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.4
    • /
    • pp.86-93
    • /
    • 2002
  • There are many different factors used in calculating control limits of control chart for variable data. Specially these factors are divided into two groups such as "no given standard" and "given standard"(namely, for analysis and management), but many kind of factors give rise to confusion. Therefore, It is necessary to manifest relationships among factors for easy application regardless of subgroup size. Many SQC textbooks show us plainly these factors, but do not have enough for adequate explanation of relationships among factors. Besides, notation of these factors of SQC textbook isn't coincide with another one, so necessity to the coincidence for the notation of the factors is highlighted during my work recently. In this study, the close examination about relationships among various factors (A-A3, B3-B6, D1-D4, C4, d2, d3 etc) was carried out. Spread sheet results are presented for getting factors according to subgroup size, by grouping as the case of "no given standard" and "given standard". How are these factors to be applied in statistical package (ex, Minitab) have been analyzed using a series of sample data. analyzed using a series of sample data.

Effect of the Hydrophilic Treatment of Polyolefin Separator on the Electrochemical Characteristics for Ni-MH Secondary Battery (폴리올레핀계 분리막의 친수화 처리방법에 따른 Ni-MH 2차 전지의 전기화학적 특성연구)

  • Song, Li-Gyu;Lee, Yun-Sung
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.263-266
    • /
    • 2013
  • It was investigated the electrochemical characteristics of the Ni-MH battery by hydrophilic process. For adopting the Ni-MH battery in water-electrolyte, polyolefin separator was processed the hydrophilic treatment. No treatment sample did not meet KS standard (KSC 8544) but hydrophilic treatment ones satisfied with the KS standard in electrochemical characteristics, such as discharge performance, retention capacity, and cycle performance. All hydrophilic treatment samples showed similar battery performances. Among them, sulfonation treatment sample exhibited the highest value in aspect of capacity retention rate (> 88%). Furthermore, fluoride treatment sample showed the best cycle performance during battery test. This sample maintained a good cycling performance until $1,480^{th}$ cycle, which was about 3 times as compared with that of KS standard (500 cycle).

Monitoring of compositions of gamma-linolenic and omega-3 fatty acids in some functional foods consumed in market (유통중인 건강기능식품의 감마-리놀렌산 및 오메가-3 지방산 함량 모니터링)

  • Kim, Dae-Kyung;Shin, Jung-Ah;Lee, Ki-Teak
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.2
    • /
    • pp.277-284
    • /
    • 2011
  • The compositions of health functional food products (HFFP; 18 products) containing gamma linolenic acid (GLA; $C_{18:3}$, n-6) and omega-3 fatty acids (EPA and DHA) were investigated. The contents of index components (especially, GLA and omega-3) in HFFPs were monitored by GC-FID analysis. Among the GLA products (sample No. 1~8), the content of GLA in most samples (except sample No.6) ranged from 8.04 to 9.98 g/100 g. These results were suitable for the reference standard (more 7.0 g/100 g) of HFF. In the omega-3 products (sample No. 10 and 15) derived from harp seal oil (HSO), the total contents of EPA and DHA were 14.21-15.98 g/100 g, respectively. These values were suitable for the reference standard (more 12.0 g/100 g) of HFF. Besides, among the omega-3 products (sample No.9, 11~14, 16~18) derived from fish oil, the total content of EPA and DHA ranged from 24.11 to 31.20 g/100 g. These results were suitable for the reference standard (more 18.0 g/100 g) of HFF. In the result of TLC analysis, the HFFPs of 18 were mainly composed of triacylglycerols (TAGs). The content of trans fatty acid in 18 HFFPs was detected in less than 0.30 g/100 g. For the detection of trans fatty acid, $^1H$-NMR (600 MHz) can be used because chemical shift of trans fatty acid was observed at 5.3 ppm in this study.

An Overview of Bootstrapping Method Applicable to Survey Researches in Rehabilitation Science

  • Choi, Bong-sam
    • Physical Therapy Korea
    • /
    • v.23 no.2
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Parametric statistical procedures are typically conducted under the condition in which a sample distribution is statistically identical with its population. In reality, investigators use inferential statistics to estimate parameters based on the sample drawn because population distributions are unknown. The uncertainty of limited data from the sample such as lack of sample size may be a challenge in most rehabilitation studies. Objects: The purpose of this study is to review the bootstrapping method to overcome shortcomings of limited sample size in rehabilitation studies. Methods: Articles were reviewed. Results: Bootstrapping method is a statistical procedure that permits the iterative re-sampling with replacement from a sample when the population distribution is unknown. This statistical procedure is to enhance the representativeness of the population being studied and to determine estimates of the parameters when sample size are too limited to generalize the study outcome to target population. The bootstrapping method would overcome limitations such as type II error resulting from small sample sizes. An application on a typical data of a study represented how to deal with challenges of estimating a parameter from small sample size and enhance the uncertainty with optimal confidence intervals and levels. Conclusion: Bootstrapping method may be an effective statistical procedure reducing the standard error of population parameters under the condition requiring both acceptable confidence intervals and confidence level (i.e., p=.05).

Functional Integration of Serial Dilution and Capillary Electrophoresis on a PDMS Microchip

  • Chang, Jun-Keun;Heo, Yun-Seok;Hyunwoo Bang;Keunchang Cho;Seok Chung;Chanil Chung;Han, Dong-Chul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.233-239
    • /
    • 2003
  • For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations, measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained from the electropherograms showed the expected linearity.

Using the Sample IQR for Calculating Sample Size (표본크기 결정을 위한 IQR의 활용방법)

  • 홍종선;김현태;윤상호;정민정
    • The Korean Journal of Applied Statistics
    • /
    • v.16 no.1
    • /
    • pp.181-193
    • /
    • 2003
  • Without a sample standard deviation for an estimator of the population standard deviation u in a sample size computations, we often use some functions of a sample range (R) or interquartile range (IQR) by an estimator of $\sigma$. In order to avoid under-powered studies, these estimates must have a high probability of being greater than or equal to $\sigma$. In this paper, these probabilities of being greater than or equal to $\sigma$ are estimated for IQR for various parents distributions, and are compared with the probabilities for R/4 (Browne 2001). Alternative divisors (K) are explored and discussed for which the probabilities of R/K and IQR/K being greater than or equal to $\sigma$ is at least 95%.

Bootstrap estimation of the standard error of treatment effect with double propensity score adjustment (이중 성향점수 보정 방법을 이용한 처리효과 추정치의 표준오차 추정: 붓스트랩의 적용)

  • Lim, So Jung;Jung, Inkyung
    • The Korean Journal of Applied Statistics
    • /
    • v.30 no.3
    • /
    • pp.453-462
    • /
    • 2017
  • Double propensity score adjustment is an analytic solution to address bias due to incomplete matching. However, it is difficult to estimate the standard error of the estimated treatment effect when using double propensity score adjustment. In this study, we propose two bootstrap methods to estimate the standard error. The first is a simple bootstrap method that involves drawing bootstrap samples from the matched sample using the propensity score as well as estimating the standard error from the bootstrapped samples. The second is a complex bootstrap method that draws bootstrap samples first from the original sample and then applies the propensity score matching to each bootstrapped sample. We examined the performances of the two methods using simulations under various scenarios. The estimates of standard error using the complex bootstrap were closer to the empirical standard error than those using the simple bootstrap. The simple bootstrap methods tended to underestimate. In addition, the coverage rates of a 95% confidence interval using the complex bootstrap were closer to the advertised rate of 0.95. We applied the two methods to a real data example and found also that the estimate of the standard error using the simple bootstrap was smaller than that using the complex bootstrap.

Calculation of the Correction Factors related to the Diameter and Density of the Concrete Core Samples using a Monte Carlo Simulation (몬테카를로 전산해석을 이용한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자 계산)

  • Lee, Kyu-Young;Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.503-510
    • /
    • 2020
  • Concrete is one of the most widely used materials as the shielding structures of a nuclear facilities. It is also the most generated radioactive waste in quantity while dismantling facilities. Since the concrete captures neutrons and generates various radionuclides, radiation measurement and analysis of the sample was fulfilled prior to dismantle facilities. An HPGe detector is used in general for the radiation measurement, and effective correction factors such as geometrical correction factor, self-absorption correction, and absolute detector efficiency have to be applied to the measured data to decide exact radioactivity of the sample. Correction factors are obtained by measuring data using a standard source with the same geometry and chemical states as the sample under the same measurement conditions. However, it is very difficult to prepare standard concrete sources because concrete is limited in pretreatment due to various constituent materials and high density. In addition, the concrete sample obtained by core drill is a volumetric source, which requires geometric correction for sample diameter and self absorption correction for sample density. Therefore in recent years, many researchers are working on the calculation of effective correction factors using Monte carlo simulation instead of measuring them using a standard source. In this study we calculated, using Geant4, one of the Monte carlo codes, the correction factors for the various diameter and density of the concrete core sample at the gamma ray energy emitted from the nuclides 152Eu and 60Co, which are the most generated in radioactive concrete.

Variable Sampling Interval $\bar{X}$ Control Chart Using Weighted Standard Deviation Method (가중표준편차를 이용한 가변표본채취간격 $\bar{X}$ 관리도)

  • Chang, Youngsoon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.39 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • This article proposes a variable sampling interval (VSI) $\bar{X}$ control chart using weighted standard deviation (WSD) method for skewed populations. The WSD method decomposes the standard deviation of a quality characteristic into upper and lower deviations and adjusts control limits and warning limits of a control chart in accordance with the direction and degree of skewness. A control chart constant is derived for estimating the standard deviation of skewed distributions with the mean of sample standard deviations. The proposed chart is compared with the conventional VSI $\bar{X}$ control chart under some skewed distributions. Simulation study shows that the proposed WSD VSI chart can control the in-control average time to signal (ATS) as an adequate level better than the conventional VSI chart, and the proposed chart can detect a decrease in the process mean of a quality characteristic following a positively skewed distribution more quickly than the standard VSI chart.