• Title/Summary/Keyword: Standard sample

Search Result 2,191, Processing Time 0.038 seconds

Can the C-14 Urea Breath Test Reflect the Extent and Degree of Ongoing Helicobacter pylori Infection? (C-14 요소호기검사의 정량치가 Helicobacter pylori 감염 정도를 반영할 수 있을까?)

  • Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok;Lee, Soo-Teik;Jeong, Myoung-Ja
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.61-68
    • /
    • 2001
  • Purpose: The C-14 urea breath test (C-14 UBT) is the most specific noninvasive method to detect Helicobacter (H) pylori infection. We investigated if the C-14 UBT can reflect the presence and degree of H. pylori detected by gastroduodenoscopic biopsies (GBx). Materials and methods: One hundred fifty patients (M:F=83:67, age $48.6{\pm}11.2$ yrs) underwent C-14 UBT, rapid urease test (CLO test) and GBx on the same day. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (137 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive (${\geq}200dpm$), Intermediate ($50{\sim}199dpm$) or negative (<50 dpm). The results of CLO tests were classified as positive or negative according to color change. The results of GBx on giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT results with GBx grade as a gold standard. Results: In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.5%, 88.4%, 97.1%, 88.4% and 91.3%, respectively. However, the CLO test had sensitivity, specificity, PPV, NPV and accuracy of 83.2%, 81.4%, 91.8%, 81.4% and 82.7%, respectively. The quantitative values of the C-14 UBT were $45{\pm}27$ dpm in grade 0, $707{\pm}584dpm$ in grade 1, $1558{\pm}584dpm$ in grade 2, $1851{\pm}604dpm$ in grade 3, and $2719{\pm}892dpm$ in grade 4. A significant correlation (r=0.848, p<0.01) was found between C-14 UBT and the grade of distribution of H. pylori infection on GBx with giemsa stain. Conclusion: We conclude that the C-14 UBT is a highly accurate, simple and noninvasive method for the diagnosis of ongoing H. pylori infection and reflects the degree of bacterial distribution.

  • PDF

Comparison of the Quantitative Values of C-14 and C-13 UBT to Reflect the Presence and Degree of Ongoing Helicobacter pylori Infection (Helicobacter pylori 감염 유무와 정도 반영에 대한 C-14와 C-13 요소호기검사 정량치 비교)

  • Lim, Seok-Tae;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.229-234
    • /
    • 2008
  • Purpose: A urea breath test (UBT) using C-14 or C-13 has been developed for identifying Helicobacter (H) pylori infection on the basis of urease production with release of labeled $CO_2$. We investigated if the C-14 and C-13 UBT have the difference to reflect the presence and degree of H. pylori infection detected by gastro-duodenoscopic biopsies (CBx) in the same patients. Materials and methods: Thirty eight patients (M:F = 28:10, age $53.4{\pm}13.0$ yrs) with upper gastrointestinal symptoms such as indigestion, gastric fullness or pain consecutively underwent C-14 UBT, GBx and C-13 UBT within one week before medications. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (37 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive (${\ge}$ 200 dpm), intermediate (50-199 dpm) or negative (50 dpm). For the C-13 UBT, the results were classified as positive (${\ge}2.5\%_{\circ}$) or negative ($<2.5\%_{\circ}$). The results of GBx with Giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT and C-13 UBT results with GBx grade as a gold standard. Results: The prevalence of H. pylori infection by GBx with Giemsa stain was 25/38 (65.8%). In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.0%, 92.3%, 95.8%, 91.7% and 92.1%, respectively. However, the C-13 UBT had sensitivity, specificity, PPV, NPV and accuracy of 96.0%, 84.6%, 92.3%, 91.7% and 92.1%, respectively. The more significant correlation in C-14 than C-13 UBT (r=0.948 vs r=0.819, p <0.001) was found between the value of UBT and the grade of distribution of H. pylori infection. Conclusion: We conclude that the diagnostic performance between C-14 and C-13 UBT to detect H. pylori infection is not significantly different, but the value of C-14 UBT more significantly reflects the degree of bacterial distribution.

Development and Validation of Analytical Method for Nitroxoline in Chicken Using HPLC-PDA (HPLC-PDA를 이용한 닭고기 중 Nitroxoline 분석법 개발)

  • Cho, Yoon-Jae;Chae, Young-Sik;Kim, Jae-Eun;Kim, Jae-Young;Kang, Ilhyun;Lee, Sang-Mok;Do, Jung-Ah;Oh, Jae-Ho;Chang, Moon-Ik;Hong, Jin-Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.1
    • /
    • pp.70-77
    • /
    • 2013
  • BACKGROUND: Nitroxoline is an antibiotic agent. It is used for the treatment of the second bacterial infection by the colibacillosis, salmonellosis and viral disease of the poultry. When the nitroxoline is indiscreetly used, the problem about the abuse of the antibiotics can occur. Therefore, this study presented the residue analytical method of nitroxoline in food for the safety management of animal farming products. METHODS AND RESULTS: A simple, sensitive and specific method for nitroxoline in chicken muscle by high performance liquid chromatograph with PDA was developed. Sample extraction with acetonitrile, purification with SPE cartridge (MCX) were applied, then quantitation by HPLC with C18 column under the gradient condition with 0.1 % tetrabutylammonium hydroxide-phosphoric acid and methanol was performed. Standard calibration curve presented linearity with the correlation coefficient ($r^2$) > 0.999, analysed from 0.02 to 0.5 mg/L concentration. Limit of quantitation in chicken muscle showed 0.02 mg/kg, and average recoveries ranged from 72.9 to 88.1 % in chicken muscle. The repeatability of measurements expressed as coefficient of variation (CV %) was less than 12 % in 0.02 and 0.04 mg/kg. CONCLUSION(S): Newly developed method for nitroxoline in chicken muscle was applicable to food inspection with the acceptable level of sensitivity, repeatability and reproducibility.

Quantitative Evaluation of Foodborne Pathogenic Bacteria in Commercial Sangshik (시판 생식에서 식중독균의 정량적 평가)

  • Kwak Hyo-Sun;Whang In-Kyun;Park Jong-Seok;Kim Mi-Gyeung;Lee Kyun-Young;Gho Young-Ho;Bae Yoon-Young;Moon Sung-Yang;Byun Ju-Sun;Kwon Ki-Sung;Woo Gun-Jo
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.1
    • /
    • pp.41-46
    • /
    • 2006
  • This study was carried out to survey the prevalence of foodborne pathogens in Sangshik products and their raw materials far the purpose of ensuring safety of those products in market, and establishing microbial regulatory standard. From 2002 to 2004, a total of 191 Sangshik products were purchased from market or mail-order sales, and major foodborne pathogens; E. coli, Salmonella, Staphylococcus aureus, Bacillus cereus, Clostridium perfringens, Listeria monocytogenes, Campylobacter jejuni, Yersinia enterocolitica, E. coli O157:H7, Vibrio parahaemolyticus were tested. B. cereus, C. perfringens and E. coli were detected from 29 samples (15.2%), 21 samples (11.0%) and 1 sample (0.5%), respectively. But other tested bacteria were not detected. For the identification of contamination source, 53 Sangshik ingredients were collected from 9 different manufacture factories. The results were similar with the Sangshik products. Aerobic plate counts were ranging from $1.0X10^3cfu/g\;to\;1.5X10^8cfu/g$. B. cereus was detected from 13 samples (24.5%), and counted as less than 100 cfu/g. C. perfringens were detected from 2 samples (3.8%), and counted as less than 100 cfu/g. Other foodborne pathogens were not detected except for B. cereus and C. perfringens. From the results, it was revealed that potential of microbial hazard by Sangshik was relatively low. However, it would be suggested that hygienic management and controling be needed for the prevention of growing contaminated pathogens and cross contamination during process and sale due to improper storage and management.

Establishment and Application of Landscape Control Point Selection Method for Landscape Assessment of Urban Development Projects (도시개발사업의 경관평가를 위한 조망점 선정체계 구축 및 적용)

  • Jang, Cheol-Kyu;Jung, Sung-Gwan;Kim, Kyung-Tae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.3
    • /
    • pp.39-50
    • /
    • 2011
  • This study furnishes basis data for plan foundation and proper valuation of view by presenting objective and concrete selection standards and ways of Landscape Control Point(LCP) on valuation of development projects. To sum up the results of study, it establishes the prospect, publicity and direction of view as a selection standard LCP on precedent studies. The prospect, which includes visual range, direction of view, geographical features, and visibility, sets up as a valuation basis picking out the available places which have alterations according to direction and distance in practice. In the case of publicity, to select the place as there presentative area where public activities often happen than others, thirteen evaluation indexes including administration facilities, educational facilities, commercial facilities and so on. And variation of landscape is set up as an assessment index to know how much the land has changed from the beginning to the end of development. To apply the selection standards to sample places, the preliminary LCP is founded by analyzing both the prospect and published; a series of courses for selecting the final LCP is founded by analyzing the preliminary LCP and variableness of landscape on a basic of placed which have many alterations of view. At last, in the case of a selection system for LCP, the preliminary LCP is founded by analyzing both the prospect and publicity; a series of courses for selecting the final LCP is found by analyzing the preliminary LCP and variableness of landscape. Applying selection standards and the assessment index to the Sam-deok 3 residence improvement area, in the case of prospect, the southern distant view area has the largest extent. Next, the results of the assessment using the system of publicity show that a five-lane road is taking up the largest area. Hence, a total of 48 preliminary LCPs are set up by analyzing both the prospect and publicity. The results of analyzing landscape variation, one of the valuation indexes, show that Sam-deok dong around the post office has the highest rate of variation at 28.07%. Finally, three LCPs in each part, which are close range, middle range and distance view, are selected; thus, a total of nine LCPs are selected. The selected LCPs that go through a series of practical courses like a GIS program have a lot of professional opinions and are expected to secure objectivity of landscape assessment.

Factors Affecting the Implementation Success of Data Warehousing Systems (데이터 웨어하우징의 구현성공과 시스템성공 결정요인)

  • Kim, Byeong-Gon;Park, Sun-Chang;Kim, Jong-Ok
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2007.05a
    • /
    • pp.234-245
    • /
    • 2007
  • The empirical studies on the implementation of data warehousing systems (DWS) are lacking while there exist a number of studies on the implementation of IS. This study intends to examine the factors affecting the implementation success of DWS. The study adopts the empirical analysis of the sample of 112 responses from DWS practitioners. The study results suggest several implications for researchers and practitioners. First, when the support from top management becomes great, the implementation success of DWS in organizational aspects is more likely. When the support from top management exists, users are more likely to be encouraged to use DWS, and organizational resistance to use DWS is well coped with increasing the possibility of implementation success of DWS. The support of resource increases the implementation success of DWS in project aspects while it is not significantly related to the implementation success of DWS in organizational aspects. The support of funds, human resources, and other efforts enhances the possibility of successful implementation of project; the project does not exceed the time and resource budgets and meet the functional requirements. The effect of resource support, however, is not significantly related to the organizational success. The user involvement in systems implementation affects the implementation success of DWS in organizational and project aspects. The success of DWS implementation is significantly related to the users' commitment to the project and the proactive involvement in the implementation tasks. users' task. The observation of the behaviors of competitors which possibly increases data quality does not affect the implementation success of DWS. This indicates that the quality of data such as data consistency and accuracy is not ensured through the understanding of the behaviors of competitors, and this does not affect the data integration and the successful implementation of DWS projects. The prototyping for the DWS implementation positively affects the implementation success of DWS. This indicates that the extent of understanding requirements and the communication among project members increases the implementation success of DWS. Developing the prototypes for DWS ensures the acquirement of accurate or integrated data, the flexible processing of data, and the adaptation into new organizational conditions. The extent of consulting activities in DWS projects increases the implementation success of DWS in project aspects. The continuous support for consulting activities and technology transfer enhances the adherence to the project schedule preventing the exceeding use of project budget and ensuring the implementation of intended system functions; this ultimately leads to the successful implementation of DWS projects. The research hypothesis that the capability of project teams affects the implementation success of DWS is rejected. The technical ability of team members and human relationship skills themselves do not affect the successful implementation of DWS projects. The quality of the system which provided data to DWS affects the implementation success of DWS in technical aspects. The standardization of data definition and the commitment to the technical standard increase the possibility of overcoming the technical problems of DWS. Further, the development technology of DWS affects the implementation success of DWS. The hardware, software, implementation methodology, and implementation tools contribute to effective integration and classification of data in various forms. In addition, the implementation success of DWS in organizational and project aspects increases the data quality and system quality of DWS while the implementation success of DWS in technical aspects does not affect the data quality and system quality of DWS. The data and systems quality increases the effective processing of individual tasks, and reduces the decision making times and efforts enhancing the perceived benefits of DWS.

  • PDF

A Study on the Method of Minimizing the Bit-Rate Overhead of H.264 Video when Encrypting the Region of Interest (관심영역 암호화 시 발생하는 H.264 영상의 비트레이트 오버헤드 최소화 방법 연구)

  • Son, Dongyeol;Kim, Jimin;Ji, Cheongmin;Kim, Kangseok;Kim, Kihyung;Hong, Manpyo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.2
    • /
    • pp.311-326
    • /
    • 2018
  • This paper has experimented using News sample video with QCIF ($176{\times}144$) resolution in JM v10.2 code of H.264/AVC-MPEG. The region of interest (ROI) to be encrypted occurred the drift by unnecessarily referring to each frame continuously in accordance with the characteristics of the motion prediction and compensation of the H.264 standard. In order to mitigate the drift, the latest related research method of re-inserting encrypted I-picture into a certain period leads to an increase in the amount of additional computation that becomes the factor increasing the bit-rate overhead of the entire video. Therefore, the reference search range of the block and the frame in the ROI to be encrypted is restricted in the motion prediction and compensation for each frame, and the reference search range in the non-ROI not to be encrypted is not restricted to maintain the normal encoding efficiency. In this way, after encoding the video with restricted reference search range, this article proposes a method of RC4 bit-stream encryption for the ROI such as the face to be able to identify in order to protect personal information in the video. Also, it is compared and analyzed the experimental results after implementing the unencrypted original video, the latest related research method, and the proposed method in the condition of the same environment. In contrast to the latest related research method, the bit-rate overhead of the proposed method is 2.35% higher than that of the original video and 14.93% lower than that of the latest related method, while mitigating temporal drift through the proposed method. These improved results have verified by experiments of this study.

A Study on the Characteristics of Condensable Fine Particles in Flue Gas (배출가스 중 응축성미세먼지 특성 연구)

  • Gong, Buju;Kim, Jonghyeon;Kim, Hyeri;Lee, Sangbo;Kim, Hyungchun;Jo, Jeonghwa;Kim, Jeonghun;Gang, Daeil;Park, Jeong Min;Hong, Jihyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.501-512
    • /
    • 2016
  • The study evaluated methods to measure condensable fine particles in flue gases and measured particulate matter by fuel and material to get precise concentrations and quantities. As a result of the method evaluation, it is required to improve test methods for measuring Condensable Particulate Matter (CPM) emitted after the conventional Filterable Particulate Matter (FPM) measurement process. Relative Standard Deviation (RSD) based on the evaluated analysis process showed that RSD percentages of FPM and CPM were around 27.0~139.5%. As errors in the process of CPM measurement and analysis can be caused while separating and dehydrating organic and inorganic materials from condensed liquid samples, transporting samples, and titrating ammonium hydroxide in the sample, it is required to comply with the exact test procedures. As for characteristics of FPM and CPM concentrations, CPM had about 1.6~63 times higher concentrations than FPM, and CPM caused huge increase in PM mass concentrations. Also, emission concentrations and quantities varied according to the characteristics of each fuel, the size of emitting facilities, operational conditions of emitters, etc. PM in the flue gases mostly consisted of CPM (61~99%), and the result of organic/inorganic component analysis revealed that organic dusts accounted for 30~88%. High-efficiency prevention facilities also had high concentrations of CPM due to large amounts of $NO_x$, and the more fuels, the more inorganic dusts. As a result of comparison between emission coefficients by fuel and the EPA AP-42, FPM had lower result values compared to that in the US materials, and CPM had higher values than FPM. For the emission coefficients of the total PM (FPM+CPM) by industry, that of thermal power stations (bituminous coal) was 71.64 g/ton, and cement manufacturing facility (blended fuels) 18.90 g/ton. In order to estimate emission quantities and coefficients proper to the circumstances of air pollutant-emitting facilities in Korea, measurement data need to be calculated in stages by facility condition according to the CPM measurement method in the study. About 80% of PM in flue gases are CPM, and a half of which are organic dusts that are mostly unknown yet. For effective management and control of PM in flue gases, it is necessary to identify the current conditions through quantitative and qualitative analysis of harmful organic substances, and have more interest in and conduct studies on unknown materials' measurements and behaviors.

Determination of finasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 finasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.345-351
    • /
    • 2011
  • A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) method was developed and validated for the determination of finasteride in human serum. Beclomethasone was used as internal standard (IS) and liquid-liquid extraction (LLE) using methyl tert-butyl ether (MTBE) was carried out to isolate analyte. The mass transitions monitored in multiple reaction monitoring (MRM) in positive ion mode were m/z 373.2${\rightarrow}$305.2 for finasteride and m/z 409.3${\rightarrow}$391.2 for IS. Retention times of finasteride and IS were 5.81 and 5.46 min, respectively. The limit of quantitation (LOQ) was 0.1 ng/mL and the calibration curve showed good linearity in the range of 0.1~20.0 ng/mL ($R^2$=0.9997). The intra-day assay precision and accuracy were in the range 6.3~10.6% and 97.3~103.6%, respectively, and the inter-day assay precision and accuracy were in the range 0.8~5.2% and 99.8~102.5%, respectively. The sample extract recovery of the method was 80~83%.

Analysis of Diflubenzuron in Agricultural Commodities by Multiresidue Method (동시 다성분 분석법에 의한 농산물 중 Diflubenzuron 분석)

  • Park, Sun-Hee;Han, Chang-Ho;Kim, Ae-Kyung;Shin, Jae-Min;Lee, Jae-Kyoo;Park, Young-Hae;Kim, Ji-Min;Hwang, Lae-Hong;Chang, Min-Su;Song, Mi-Ok;Park, Ju-Sung;Yun, Eun-Sun;Kim, Mu-Sang;Jung, Kweon
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.269-277
    • /
    • 2014
  • The multiclass pesticide multiresidue method for the simultaneous determination of diflubenzuron in agricultural products was conducted by using HPLC-UVD. The method was validated through the guidelines of linearity, specificity, limit of detection (LOD), limit of quantification (LOQ), accuracy and precision with pesticide-free spinach, Korean cabbage, eggplant, squash, sweet pepper, cucumber, Korean melon. The calibration curve of diflubenzuron was linear over the concentration range of 0.05-5 mg/kg with correlation coefficient of above 0.99999. The limit of detection and quantification was 0.008 and 0.02 mg/kg. Mean recoveries of diflubenzuron for each sample were 77.5-105.6%. Relative standard deviation (RSD) in recoveries were all less than 20%. The intra-day and inter-day precision (RSD) were 0.4-1.9% and 0.7-1.9%, respectively. The result of validation indicated that this method was accurate and rapid assay.