• Title/Summary/Keyword: Standard reference

Search Result 2,179, Processing Time 0.027 seconds

Development and Validation of an Analytical Method for Fenpropimorph in Agricultural Products Using QuEChERS and LC-MS/MS (QuEChERS법과 LC-MS/MS를 이용한 농산물 중 Fenpropimorph 시험법 개발 및 검증)

  • Lee, Han Sol;Do, Jung-Ah;Park, Ji-Su;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Choi, Young-Nae;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.115-123
    • /
    • 2019
  • An analytical method was developed for the determination of fenpropimorph, a morpholine fungicide, in hulled rice, potato, soybean, mandarin and green pepper using QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) sample preparation and LC-MS/MS (liquid chromatography-tandem mass spectrometry). The QuEChERS extraction was performed with acetonitrile followed by addition of anhydrous magnesium sulfate and sodium chloride. After centrifugation, d-SPE (dispersive solid phase extraction) cleanup was conducted using anhydrous magnesium sulfate, primary secondary amine sorbents and graphitized carbon black. The matrix-matched calibration curves were constructed using seven concentration levels, from 0.0025 to 0.25 mg/kg, and their correlation coefficient ($R^2$) of five agricultural products were higher than 0.9899. The limits of detection (LOD) and quantification (LOQ) were 0.001 and 0.0025 mg/kg, respectively, and the limits of quantification for the analytical method were 0.01 mg/kg. Average recoveries spiked at three levels (LOQ, $LOQ{\times}10$, $LOQ{\times}50$, n=5) and were in the range of 90.9~110.5% with associated relative standard deviation values less than 5.7%. As a result of the inter-laboratory validation, the average recoveries between the two laboratories were 88.6~101.4% and the coefficient of variation was also below 15%. All optimized results were satisfied the criteria ranges requested in the Codex guidelines and Food Safety Evaluation Department guidelines. This study could serve as a reference for safety management relative to fenpropimorph residues in imported and domestic agricultural products.

Consideration of a Bacteria Contamination Management in the Dispensation of 99mTc Radiopharmaceutical (테크네슘 방사성의약품의 조제와 분배 과정에서 오염균에 대한 고찰)

  • Choi, Do Chul;Gim, Yeong Su;Jo, Gwang Mo;Gim, Hui Jeong;Seo, Han Gyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.84-87
    • /
    • 2018
  • Purpose The radiopharmaceutical used in the nuclear medicine department is used only for the specific patient according to the prescription or instruction of the doctor without selling, so it is dispensed and it is distributed and used for the examination. Radiopharmaceuticals administered to patients should be managed appropriately as well as radiation safety management during dispensation. The purpose of this study is to investigate microbial contamination during dispensation of radiopharmaceuticals Materials and Methods This study distinguished between general workbench and clean workbench and performed three tests. First, microbial cultivation test of radiopharmaceutical prepared and dispensed in general workbenches and sterile workbenches were carried out five times, respectively. The second test was performed settle plate method three times before and after the use of the exhaust filter. Finally, Adenosine Triphosphate (ATP) measurement was performed in each workbench to measure bacterial counts. In addition, ATP measurement were carried out by designating locations and items that may be contaminated during dispensation. Results In the microbial culture test, no microorganisms were detected in both samples. In the settle plate method, it was detected without using of the exhaust filter in a general workbench once. In the ATP measurement test, it was measured at the level of 400 RLU or less, which is the standard value of contamination, in both workbenches surface. In additional ATP measurement test, the refrigerator handle in the distribution room was measured above the reference value of 1217 RLU, the vacuum vial shield of the Tech Generator at 435 RLU, and the syringe holder at 1357 RLU. After environmental disinfection, the results were reduced to 311 RLU, 136 RLU, and 291 RLU. Conclusion No contamination by bacteria was found in both workbenches. However, microbial contamination may occur if the use of an exhaust filter or proper hand hygiene is not achieved. Regular inspections and management for aseptic processing themselves will be necessary.

Performance Analysis and Comparison of Stream Ciphers for Secure Sensor Networks (안전한 센서 네트워크를 위한 스트림 암호의 성능 비교 분석)

  • Yun, Min;Na, Hyoung-Jun;Lee, Mun-Kyu;Park, Kun-Soo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.5
    • /
    • pp.3-16
    • /
    • 2008
  • A Wireless Sensor Network (WSN for short) is a wireless network consisting of distributed small devices which are called sensor nodes or motes. Recently, there has been an extensive research on WSN and also on its security. For secure storage and secure transmission of the sensed information, sensor nodes should be equipped with cryptographic algorithms. Moreover, these algorithms should be efficiently implemented since sensor nodes are highly resource-constrained devices. There are already some existing algorithms applicable to sensor nodes, including public key ciphers such as TinyECC and standard block ciphers such as AES. Stream ciphers, however, are still to be analyzed, since they were only recently standardized in the eSTREAM project. In this paper, we implement over the MicaZ platform nine software-based stream ciphers out of the ten in the second and final phases of the eSTREAM project, and we evaluate their performance. Especially, we apply several optimization techniques to six ciphers including SOSEMANUK, Salsa20 and Rabbit, which have survived after the final phase of the eSTREAM project. We also present the implementation results of hardware-oriented stream ciphers and AES-CFB fur reference. According to our experiment, the encryption speeds of these software-based stream ciphers are in the range of 31-406Kbps, thus most of these ciphers are fairly acceptable fur sensor nodes. In particular, the survivors, SOSEMANUK, Salsa20 and Rabbit, show the throughputs of 406Kbps, 176Kbps and 121Kbps using 70KB, 14KB and 22KB of ROM and 2811B, 799B and 755B of RAM, respectively. From the viewpoint of encryption speed, the performances of these ciphers are much better than that of the software-based AES, which shows the speed of 106Kbps.

Improvement of an Analytical Method for Fluoroimide Residue in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Fluoroimide의 잔류농약 분석법 개선)

  • Kim, Nam Young;Park, Eun-Ji;Shim, Jae-Han;Lee, Jung Mi;Jung, Yong Hyun;Oh, Jae-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.3
    • /
    • pp.220-227
    • /
    • 2021
  • Fluoroimide is a fungicide and is also used as a pesticide for persimmons and potatoes. The established fluoroimide pesticide analysis method takes a long time to perform and uses benzene, a carcinogen. In addition, a lower limit of quantification is required due to enforcement of the Positive List System. Therefore, this study aimed to improve the analysis method for residual fluoroimide to resolve the problems associated with the current method. The analytical method was improved with reference to the increased stability of fluoroimide under acidic conditions. Fluoroimide was extracted under acidic conditions by hydrogen chloride (4 N) and acetic acid. MgSO4 and NaCl were used with acetonitrile. C18 (octadecylsilane) 500 mg and graphitized carbon black 40 mg were used in the purification process. The experiment was conducted with agricultural products (hulled rice, potato, soybean, mandarin, green pepper), and liquid chromatograph-tandem mass spectrometry was used for the instrumental analysis. Recovery of fluoroimide was 85.7-106.9% with relative standard deviations (RSDs) of less than 15.6%. This study reports an improved method for the analysis of fluoroimide that might contribute to safety by substituting the use of benzene, a harmful solvent. Furthermore, the use of QuEChERS increased the efficiency of the improved method. Finally, this research confirmed the precise limit of quantification and these results could be used to improve the analysis of other residual pesticides in agricultural products.

A Study on the Structural Reinforcement of the Modified Caisson Floating Dock (개조된 케이슨 플로팅 도크의 구조 보강에 대한 연구)

  • Kim, Hong-Jo;Seo, Kwang-Cheol;Park, Joo-Shin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.172-178
    • /
    • 2021
  • In the ship repair market, interest in maintenance and repair is steadily increasing due to the reinforcement of prevention of environmental pollution caused by ships and the reinforcement of safety standards for ship structures. By reflecting this effect, the number of requests for repairs by foreign shipping companies increases to repair shipbuilders in the Southwest Sea. However, because most of the repair shipbuilders in the southwestern area are small and medium-sized companies, it is difficult to lead to the integrated synergy effect of the repair shipbuilding companies. Moreover, the infrastructure is not integrated; hence, using the infrastructure jointly is a challenge, which acts as an obstacle to the activation of the repair shipbuilding industry. Floating docks are indispensable to operating the repair shipbuilding business; in addition, most of them are operated through renovation/repair after importing aging caisson docks from overseas. However, their service life is more than 30 years; additionally, there is no structure inspection standard. Therefore, it is vulnerable to the safety field. In this study, the finite element analysis program of ANSYS was used to evaluate the structural safety of the modified caisson dock and obtain additional structural reinforcement schemes to solve the derived problems. For the floating docks, there are classification regulations; however, concerning structural strength, the regulations are insufficient, and the applicability is inferior. These insufficient evaluation areas were supplemented through a detailed structural FE-analysis. The reinforcement plan was decided by reinforcing the pontoon deck and reinforcement of the side tank, considering the characteristics of the repair shipyard condition. The final plan was selected to reinforce the side wing tank through the structural analysis of the decision; in addition, the actual structure was fabricated to reflect the reinforcement plan. Our results can be used as reference data for improving the structural strength of similar facilities; we believe that the optimal solution can be found quickly if this method is used during renovation/repair.

A Research on Buncheong Jar with dragon and cloud patterns(龍樽) in the early the Joseon Dynasty with priority given to Buncheongsagisanggamunryongmunho, National treasures (조선 초기 용준(龍樽), 분청사기 상감 운룡문 호의 특징과 성격)

  • OH, Youngin
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.1
    • /
    • pp.85-110
    • /
    • 2022
  • This study investigates the production and use, development of Buncheongsagisang-gamunryongmunho, focusing on Buncheong Jar with dragon and cloud patterns(龍樽) in the early the Joseon Dynasty. The Buncheong Jar with dragon and cloud patterns(龍樽) which is the size of a large bottle as high as 50cm is a form of stability to have gorgeous decorativeness with the inlaid and stamped pattern. The Buncheongsagisanggamunryongmunho is the Buncheong Jar with dragon and cloud patterns(龍樽) used for Flower Vessels(花樽) at Royal Ritual in King Sejong(世宗) era. In the 1420s and 1430s, made in Premium ceramic factory of Sangju-mok, it is Blue and white porcelain in reference to dragon and cloud patterns in the Yuan and Ming Dynasties in aspects of shapes and patterns, to the inlaid Celadon in the period of Late Goryeo Dynasty in aspects of patterns, and to Joseon porcelain in aspects of shapes and decoration techniques. The Joseon Royal family found out the appropriateness of the founding of the dynasty and the base for the system of civilization from Ming dynasty, to follow Ming dynasty by choosing white porcelains as the King's vessel. Jars passed down from Emperor Ming served as a standard for Royal Ritual Jars, to use Blue and White Porcelain Jar with dragon and cloud patterns as Flower Vessels(花樽) and Liquor Vessels(酒樽) for ages. Consequently, the Buncheong Jar with dragon and cloud patterns(龍樽) as Royal Ritual Jar had been used till 1430's when Blue and white porcelain Jar with dragon and cloud patterns(靑花雲龍白磁酒海) was passed down from Emperor Ming, Xuande Emperor(宣德帝), only to lose its Meaning and Use as the Royal Jar with dragon and cloud patterns(龍樽) during the early Joseon Period gradually.

Biological Toxicity Assessment of Sediment at an Ocean Dumping Site in Korea (폐기물 배출해역 퇴적물의 생물학적 독성평가 연구)

  • Seok, Hyeong Ju;Kim, Young Ryun;Kim, Tae Won;Hwang, Choul-Hee;Son, Min Ho;Choi, Ki-young;Kim, Chang-joon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • The effect of sediments in a waste dumping area on marine organisms was evaluated using sediment toxicity tests with a benthic amphipod (Monocorophium acherusicum) and bioluminescent bacterium (Vibrio fischeri) in accordance with the Korean Standard Method for Marine Wastes (KSMMW). Nine sites in the East Sea-Byeong, East Sea-Jeong, and Yellow Sea-Byeong areas were sampled from 2016 to 2019. The test results showed that the relative average survival rate (benthic amphipods) and relative luminescence inhibition rate (luminescent bacteria) were below 30%, which were judged to be "non-toxic." However, in the t-test, a total of 12 benthic amphipod samples (6, 1, 1, and 4 in 2016, 2017, 2018, and 2019, respectively) were significantly different (p<0.05) from the control samples. To identify the source of toxicity on benthic amphipods, a simple linear regression analysis was performed between the levels of eight heavy metals (Cr, As, Ni, Cd, Cu, Pb, Zn, and Hg) in sediments and the relative average survival rate. The results indicated that Cr had the highest contribution to the toxicity of benthic amphipods (p = 0.000, R2 = 0.355). In addition, Cr was detected at the highest concentration at the DB-85 station and exceeded the Marine Environment Standards every year. Although the sediments were determined as "not toxic" according to the ecotoxicity criteria of the KSMMW, the results of the statistical significance tests and toxicity identification evaluation indicated that the toxic effect was not acceptable. Therefore, revising the criteria for determining the toxic effect by deriving a reference value through quantitative risk assessment using species sensitivity distribution curves is necessary in the future.

Simultaneous determinations of anthracycline antibiotics by high performance liquid chromatography coupled with radial-flow electrochemical cell (고성능 액체 크로마토그래피/방사흐름 전기화학전지를 이용한 안트라사이클린계 항생제의 동시 정량)

  • Cho, Yonghee;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • The analytical method of HPLC with the radial-flow electrochemical cell (RFEC) has been developed to determine doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin simultaneously by employing a reversed-phase chromatography. Anthracyclines were detected at -0.74 V vs. a Ag/AgCl (0.01 M NaCl) reference electrode, a potential of diffusion current plateau in the mobile phase. At a $V_f$ of 1.0 mL/min doxorubicin, epirubicin, daunorubicin and idarubicin appeared at a retention time ($t_r$) of 6.4 min, 7.4 min, 12.7 min and 18.4 min, respectively, while at a $V_f$ of 0.6 mL/min, doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin appeared at a $t_r$ of 9.9 min, 11.5 min, 13.5 min, 19.6 min and 28.7 min, respectively. The linearity between each anthracycline injected ($2.40{\times}10^{-7}M{\sim}1.42{\times}10^{-5}M$) and peak area (charge) was excellent with the square of the correlation coefficient ($R^2$) higher than 0.999. The detection limits were $1.0{\times}10^{-8}M{\sim}1.5{\times}10^{-7}M$ for the five anthracyclines. Within-day precision for the five anthracyclines were in reasonable relative standard deviations less than 3 % ($1.00{\times}10^{-6}M{\sim}1.42{\times}10^{-5}M$) except the lower concentrations less than $0.7{\mu}M$. Solid phase extractions of $1.00{\times}10^{-5}M$ epirubicin, $0.48{\times}10^{-5}M$ nogalamycin and $1.52{\times}10^{-5}M$ daunorubicin from human serum with a $C_{18}$ cartridge resulted in 97 %, 100 % and 90 % of recoveries, respectively.

Establishment of the Room Acoustic Criteria for the Korean Traditional Music Halls Using Subjective Listening Tests (청감실험에 의한 국악당의 음향설계조건 설정)

  • Haan, Chan-Hoon;Shin, Jic-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.7
    • /
    • pp.343-352
    • /
    • 2007
  • The present study aims to investigate the design standard for acoustic criteria of Korean traditional music which could be used for the design of Korean traditional music halls. In order to do this, subjective listening tests were undertaken to musicians using auralized sounds which were convolved with the impulse response of traditional instruments recorded in an anechoic chamber. 94 pairs of sound were made which have different value of acoustic parameters including RT, BR, Brilliance, G, C80, ITDG, IACC. A paired comparison method(PCM) was used to analyze the results from the subjective listening tests. The results show that the preference of acoustic criteria for the Korean traditional music is far different from those of western music. As a result, specific range of acoustic criteria were suggested for the appropriate acoustic conditions of Korean traditional music. Also, a guideline of the acoustic design of halls for performing the Korean traditional music was suggested which could be used as a basic reference in the future works.

LI-RADS Treatment Response versus Modified RECIST for Diagnosing Viable Hepatocellular Carcinoma after Locoregional Therapy: A Systematic Review and Meta-Analysis of Comparative Studies (국소 치료 후 잔존 간세포암의 진단을 위한 LI-RADS 치료 반응 알고리즘과 Modified RECIST 기준 간 비교: 비교 연구를 대상으로 한 체계적 문헌고찰과 메타분석)

  • Dong Hwan Kim;Bohyun Kim;Joon-Il Choi;Soon Nam Oh;Sung Eun Rha
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.331-343
    • /
    • 2022
  • Purpose To systematically compare the performance of liver imaging reporting and data system treatment response (LR-TR) with the modified Response Evaluation Criteria in Solid Tumors (mRECIST) for diagnosing viable hepatocellular carcinoma (HCC) treated with locoregional therapy (LRT). Materials and Methods Original studies of intra-individual comparisons between the diagnostic performance of LR-TR and mRECIST using dynamic contrast-enhanced CT or MRI were searched in MEDLINE and EMBASE, up to August 25, 2021. The reference standard for tumor viability was surgical pathology. The meta-analytic pooled sensitivity and specificity of the viable category using each criterion were calculated using a bivariate random-effects model and compared using bivariate meta-regression. Results For five eligible studies (430 patients with 631 treated observations), the pooled per-lesion sensitivities and specificities were 58% (95% confidence interval [CI], 45%-70%) and 93% (95% CI, 88%-96%) for the LR-TR viable category and 56% (95% CI, 42%-69%) and 86% (95% CI, 72%-94%) for the mRECIST viable category, respectively. The LR-TR viable category provided significantly higher pooled specificity (p < 0.01) than the mRECIST but comparable pooled sensitivity (p = 0.53). Conclusion The LR-TR algorithm demonstrated better specificity than mRECIST, without a significant difference in sensitivity for the diagnosis of pathologically viable HCC after LRT.