• Title/Summary/Keyword: Standard of test methods

Search Result 2,211, Processing Time 0.034 seconds

A Study on the Standardization of Fineness Measurement for the Thermal Insulator of Military Textiles (방한용 화섬솜의 섬도 측정방법의 표준화에 관한 연구)

  • Hong, Seong-don;Kim, Byung-soon
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.3
    • /
    • pp.253-272
    • /
    • 2015
  • Purpose: The purpose of this study is to enhance the reliability of quality inspection by standardize the fineness test method of the thermal insulator of military textiles Methods: We have measured the thermal insulator of military textiles by microscope with three different ways and the effectiveness of their difference were analyzed by one-way layout design. Results: We have suggest the standardized the fineness test method of the thermal insulator of military textiles through advanced research. As a result we have verified hollow ratio of heat insulating fiber affect fineness test methods. The fineness test method for the thermal insulator applied with different methods following hollow ratio. We have verified that when the hollow ratio over 90%, the fineness of the thermal insulator measured from fiber-length, if it has over 80%, the cross-section length of hollow and if it has less 80%, the cross-section area of hollow is applied, respectively. Conclusion: This study indicated that the test method of fineness shows high reliability. Heat insulating fibers which have high evenness shows narrow variations(5/% or less, only CV 25%) irrespectively under different testing equipment or institute. Based ons the results, we have suggest the standardization of test methods for fineness by microscope method and produced the registration of Group Standard in Korean Standards Association.

A Study on Test Methods for Performance Appraisal of Root Barrier Appling to Green Roofs (옥상 및 인공지반녹화용 방근재의 성능기준 설정을 위한 방근성 시험방법에 관한 연구)

  • Oh, Sang-Keun;Kwak, Kyu-Sung;Sun, Yoon-Suk;Kwon, Shi-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.79-84
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we would suggest 5 items of test methods considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, size of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

Robust inference with order constraint in microarray study

  • Kang, Joonsung
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.5
    • /
    • pp.559-568
    • /
    • 2018
  • Gene classification can involve complex order-restricted inference. Examining gene expression pattern across groups with order-restriction makes standard statistical inference ineffective and thus, requires different methods. For this problem, Roy's union-intersection principle has some merit. The M-estimator adjusting for outlier arrays in a microarray study produces a robust test statistic with distribution-insensitive clustering of genes. The M-estimator in conjunction with a union-intersection principle provides a nonstandard robust procedure. By exact permutation distribution theory, a conditionally distribution-free test based on the proposed test statistic generates corresponding p-values in a small sample size setup. We apply a false discovery rate (FDR) as a multiple testing procedure to p-values in simulated data and real microarray data. FDR procedure for proposed test statistics controls the FDR at all levels of ${\alpha}$ and ${\pi}_0$ (the proportion of true null); however, the FDR procedure for test statistics based upon normal theory (ANOVA) fails to control FDR.

A study on the usefulness of standard evaluation tools for ambulance ride practices of paramedic students (응급구조(학)과 학생들의 구급현장실습 표준 평가도구의 유용성에 관한 연구)

  • Hong, Sung-Gi
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.3
    • /
    • pp.41-53
    • /
    • 2020
  • Purpose: This study tests the validity of a standard evaluation tool of ambulance ride practices with new evaluation items and supports its application by 119 preceptors. Methods: We tested the validity of standard evaluation items collected from 19 on-site professionals assessing ambulance ride practices. New evaluation items, 'understanding of emergency rescue equipment' and 'ability to communicate', were added as additional criteria. The modified Delphi technique was used to test the three evaluation areas and ten evaluation items. We used the analytic hierarchy process to analyze the weighting value of the reconstructed evaluation tool model. Results: All three evaluation areas and 10 evaluation items within the standard evaluation tools used for ambulance ride practices corresponded with the consistency index, degree of convergence, and agreement in the modified Delphi panel. Conclusion: These results provide evidence of the consistency and usefulness behind preceptors' use of this standard evaluation tool in ambulance ride practice.

Bodyshell strength analysis for standard EMU (표준전동차 개발을 위한 구조체의 강도해석)

  • 권태수;이호용;이관섭;최성규
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.455-463
    • /
    • 1998
  • The standardization urban transit project has been started by government and the Korean standard electrical railcar has been designed. The bodyshell of standard railcar is made of aluminium alloy. In the present paper, the design of its bodyshell is evaluated in the viewpoint of strength analysis. The loading condition is based on the 'Test Methods of Static Load for Body Structure of Electrical Multiple Unit', standard specification. The bodyshell of Korean standard EMU consist of longitudinal extrusion members which are double-skin structure type. The result in this paper is enough to satisfy strength requirement which is provided by standard specification. The comparison between actual experiment and analysis result will be presented in the next paper.

  • PDF

A comparative analysis of the simulation results of total window thermal transmittance(Uw) according to the evaluation method - Focused on comparison of the single window simulation results - (창세트 전체 열관류율(Uw) 평가 방법에 따른 시뮬레이션 결과 비교 분석 - 단창 창세트에 대한 시뮬레이션 결과 비교를 중심으로 -)

  • Lee, Yong-jun;Oh, Eun-joo;Kim, Sa-kyum;Choi, Hyun-jung;Kim, Yu-min
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.77-82
    • /
    • 2016
  • Purpose: The aim of this study is to calculate U-factor of the window using international standard methods and compare quantitative and tendency difference focused on ISO standard 15099 and ISO standard 10077. And the result of ISO standard calculation methods is verified using thermal performance experiment to evaluate applicability of domestic certification system. This study is utilized a basis for activation of domestic window certification system. Method: First, 16 cases are selected that is combined a variety of frame, Glazing, spacer, etc. The selected cases were simulated using WINDOW&THERM based on ISO 15099 and 10077 calculation method. Second, experiment was conducted based on Korean standard condition. Then, it was compared the error of experiment and simulation results. Through this process, ISO 15099 and 10077 calculation methods were evaluated accuracy and utilization. Result: The results show that the difference of ISO 15099 and ISO 10077-2 is maximum 5.4%. The results of comparing U-factor errors based on the Korea standard experiment test found 2.4%. Consequently, it will be possible to combination calculation methods of ISO 15099 and ISO 10077 for a single window.

The Status of Blood and Body Fluid Exposure and Affecting Factors among Nursing Students including Knowledge, Performance regarding Standard Precautions (간호대학생의 임상실습중 혈액 및 체액 노출현황과 영향 요인 - 감염관리 지식 및 수행도 중심으로-)

  • Kim, Hee-Jung;Kim, Nam-Cho
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.15 no.3
    • /
    • pp.17-30
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the status of exposure to blood and body fluid and factors affecting on blood and body fluid exposure of nursing students including knowledge, performance regarding standard precautions. Methods: 280 nursing students in D-city and S-city participated in this study. Data collection was conducted from January to March 2012. Students' knowledge and performance on standard precautions of infection control in hospitals were measured using the measurement developed by Hong(2010). Data analysis was performed using descriptive statistics, t-test, one way-ANOVA, ${\chi}^2-test$, Pearson correlation coeficient, logistic regression by the SPSS WIN 18.0 program. Results: 58.6 percent of subjects experienced a exposure to blood and body fluid. The level of nursing students' knowledge level regarding standard precautions was $22.44{\pm}2.11$ and performance level was $4.31{\pm}0.50$. The factors affecting on blood and body fluid exposure of nursing students were knowledge level and education type about infection control. Conclusions: Based on the findings of this study, to decrease the exposure to blood and body fluid of nursing students, a proper education need to be stressed to improve nursing students' infection control knowledge and awareness.

  • PDF

A Study on the Disturbance Effects with Sampling Methods of Soft Clay (연약 점성토의 시료채취방법에 따른 시료교란도의 영향에 관한 연구)

  • 박춘식;장정욱;김종환
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.577-584
    • /
    • 2002
  • We have employed two methods to remove slime at the end of the sampler in clay layers. The first method is a sampling process that harnesses low pressure to clean up the ground around the sampler tip. The second method, in consideration of a disturbed layer, involves a technique of inserting the sampler 50 cm deep into the ground before cleaning up the verge of the sampler by using high pressure. Physical and mechanical properties of these two methods have been compared and analyzed to investigate how different sampling methods affect degree of disturbance. The first method shows little disturbance since the unconfined compression test results in quite greater E$\_$50//q$\_$u/ in the first method than in the second method. On the other hand, the consolidation test results in a slightly greater compression index in the second method than in the first method, when their indexes are compared in the same depth. This suggests that the second method demonstrates less disturbance than the first method does. It is assumed that the second method may reduce disturbance slightly, However, we suspect that choosing any of the two methods would not obtain a considerable difference in sampling.

  • PDF

A Study on the Inspection Standards and Methods of Two-Wheeled Motorcycle Headlight (이륜차 전조등 검사기준 및 검사방법에 관한 연구)

  • Ha, Tae-Woong;Hong, Seung-Jun
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.3
    • /
    • pp.7-12
    • /
    • 2020
  • This paper has presented the headlight inspection standards and methods of two-wheeled motorcycles considering Korean Motor Vehicle Safety Standards (KMVSS), Korean Motor Vehicle Inspection Standards (KMVI) and the inspection standards of the International Motor Vehicle Inspection Committee (CITA). As a result of analyzing the headlight luminous intensity test result with fixed inspection equipment, 21% does not meet the inspection standard proposed in this study, and 33.3% in mobile inspection equipment does not meet. The average luminous intensity of motorcycle less than 50 cc is 8,340 cd, so all the lightweight small sized motor cycles do not meet the proposed headlight inspection standard.

An Empirical Evaluation of Test Data Generation Techniques

  • Han, Seung-Hee;Kwon, Yong-Rae
    • Journal of Computing Science and Engineering
    • /
    • v.2 no.3
    • /
    • pp.274-300
    • /
    • 2008
  • Software testing cost can be reduced if the process of testing is automated. However, the test data generation task is still performed mostly by hand although numerous theoretical works have been proposed to automate the process of generating test data and even commercial test data generators appeared on the market. Despite prolific research reports, few attempts have been made to evaluate and characterize those techniques. Therefore, a lot of works have been proposed to automate the process of generating test data. However, there is no overall evaluation and comparison of these techniques. Evaluation and comparison of existing techniques are useful for choosing appropriate approaches for particular applications, and also provide insights into the strengths and weaknesses of current methods. This paper conducts experiments on four representative test data generation techniques and discusses the experimental results. The results of the experiments show that the genetic algorithm (GA)-based test data generation performs the best. However, there are still some weaknesses in the GA-based method. Therefore, we modify the standard GA-based method to cope with these weaknesses. The experiments are carried out to compare the standard GA-based method and two modified versions of the GA-based method.