• Title/Summary/Keyword: Standard of test methods

Search Result 2,194, Processing Time 0.031 seconds

Assessing the Accuracy of Outlier Tests in Nonlinear Regression

  • Kahng, Myung-Wook;Kim, Bu-Yang
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.1
    • /
    • pp.163-168
    • /
    • 2009
  • Given the specific mean shift outlier model, the standard approaches to obtaining test statistics for outliers are discussed. Accuracy of outlier tests is investigated using subset curvatures. These subset curvatures appear to be reliable indicators of the adequacy of the linearization based test. Also, we consider obtaining graphical summaries of uncertainty in estimating parameters through confidence curves. The results are applied to the problem of assessing the accuracy of outlier tests.

Test Methodology for Multiple Clocks Single Capture Scan Design based on JTAG IEEE1149.1 Standard (IEEE 1149.1 표준에 근거한 다중 클럭을 이용한 단일 캡쳐 스캔 설계에 적용되는 경계 주사 테스트 기법에 관한 연구)

  • Kim, In-Soo;Min, Hyoung-Bok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.980-986
    • /
    • 2007
  • Boundary scan test structure(JTAG IEEE 1149.1 standard) that supports an internal scan chain is generally being used to test CUT(circuit under test). Since the internal scan chain can only have a single scan-in port and a single scan-out port; however, existing boundary test methods can not be used when multiple scan chains are present in CUT. Those chains must be stitched to form a single scan chain as shown in this paper. We propose an efficient boundary scan test structure that adds a circuit called Clock Group Register(CGR) for multiple clocks testing within the design of multiple scan chains. The proposed CGR has the function of grouping clocks. By adding CGR to a previously existing boundary scan design, the design is modified. This revised scan design overcomes the limitation of supporting a single scan-in port and out port, and it bolsters multiple scan-in ports and out ports. Through our experiments, the effectiveness of CGR is proved. With this, it is possible to test more complicated designs that have high density with a little effort. Furthermore, it will also benefit in designing those complicated circuits.

Comparison analysis of physiological work capacity for different tasks (작업유형에 따른 생리학적 작업능력의 비교 분석)

  • 박지수;김홍기;최진영
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.89-98
    • /
    • 1996
  • The objective of this study was to make comparison of the physical work capacities with different types and methods of tasks. To produce standard work loads, a bicycle ergometer and a treadmill were used for the purpose of two different types of tasks. Maximal oxygen uptake measurement tests are usually performen (1) continuously - with no rest between work load increments, or (2) discontinuously - with the subjects resting several minutes between work periods. Continuous test protocol with two different methods of work load increments, (1) ramp test- with 3 to 5 minutes of work period for each work load, and (2) incremental test - where exercise intensity was increased progressively in 2 minutes interval, were used. Predicted physicala work capacities (PWCs) were compared with the one by Kim(1990), and Lee(1995), and the NIOSH physiological criteria. For ergometer test, the PWC based on the ramp test was 89.65% of the one based on the incremental test. The PWC values were 2553.88 ml/min for the ramp test and 2848.82 ml/min for the incremental test. For treadmill test, the PWC based on the ramp test was 97.54% of the one based on the incremental test. The PWC values were 2786.89 ml/min for the ramp test and 2857.24 ml/min for the incremental test. The PWC obtained with a bicycle ergometer was 91.64% of the one obtained with a treadmill for the ramp test, and 99.71% for the incremental test.

  • PDF

Studies on quality control of domestic Morus alba Linne (국내산 상지(桑枝)의 품질관리 연구)

  • Park, Yu Mi;Beak, Mi Eun;Lee, Young Jong;Won, Jae Hee
    • The Korea Journal of Herbology
    • /
    • v.31 no.3
    • /
    • pp.71-75
    • /
    • 2016
  • Objectives : Mori Ramulus is a young branch of Morus alba Linne, which has been used as traditional medicines for antidiarrhea, antibacteria, and antihypertension in Korea. With the basis on these medicinal activities, it is registered at the Korean Herbal Pharmacopoeia. The standard for quality control in use, however, is not yet validated.Methods : We experiment on heavy metals test, TLC, loss on drying, ash, acid-insoluble ash, contents of ethanolsoluble extracts and contents of oxyresveratrol by using the 15 samples of Mori Ramulus which are collected domestically. We tested items according to the General Test, processes and apparatus, Crude Drugs Test of KP(2011).Results : Purity test(Heavy metals) showed contents for Pb, As, Hg, and Cd range of 0.1~1.1 ppm, 0.0~0.2 ppm, 0.00~0.01 ppm, and 0.00~0.02 ppm. Identification test(Thin layer chromatography) was on comparing with morucine standard solution in Rf value, all samples showed morucine spot (dark blue, Rf : 0.3) as same as Rf value of morucine-standard solution. Loss on drying was ranged from 5.1 to 8.9 %, ash and acid-insoluble ash were between the range 3.0~6.3% and 0.3~0.8%. Contents of ethanol-soluble extracts was ranged from 6.2 to 12.0%. Content of oxyresveratrol was ranged from 0.01 to 0.16 % based on the oxyresveratrol standard curve.Conclusions : We sincerely hope that this study will be contributed to the standardization and quality control of Korean herbal medicines.

Verification of the Appropriateness of the Standard for Tunnel Luminance in the Threshold Zone Through a Full-scale Tunnel Driving Test (실 규모 터널 주행실험을 통한 터널 경계부 휘도 기준의 적정성 검증)

  • Park, Won Il;Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.105-115
    • /
    • 2015
  • PURPOSES : This study aimed to evaluate the appropriateness of safety with the standard for threshold zone luminance as specified in the Recommendation for Lighting of Traffic Tunnel, which has been widely adopted worldwide. METHODS : A driving test of the subject in a full-scale road tunnel was conducted. The adaptation luminance and threshold zone luminance, which should be known for the driver to perceive an object within stopping sight distance, were obtained. These values were compared with the adaptation luminance and threshold zone luminance obtained by the existing reduced model test and tunnel lighting standard that has served as a guideline for the current threshold zone luminance standard. RESULTS : According to this study, threshold zone luminance should be increased to at least 1.8 times the value proposed in the existing studies and to twice the domestic tunnel lighting standard (KS C 3703: 2014). CONCLUSIONS : The threshold zone luminance proposed in this study differs largely from that obtained from indoor tests and from the current tunnel lighting standard used worldwide; this difference may be attributed to the fact that the indoor tests did not incorporate driving workload, non-uniformity of luminance distribution in terms of sight, and factors that reduce the visibility of the driver, such as the light reflected into the driver's eyes. Hence, it is necessary to further review the factors that reduce the visibility of drivers approaching tunnels in order to determine the rational tunnel threshold zone luminance.

Gaussian noise estimation using adaptive filtering (적응적 필터링을 이용한 가우시안 잡음 예측)

  • Joh, Beom Seok;Kim, Young Ro
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.4
    • /
    • pp.13-18
    • /
    • 2012
  • In this paper, we propose a noise estimation method for noise reduction. It is based on block and pixel-based noise estimation. We assume that an input image is contaminated by the additive white Gaussian noise. Thus, we use an adaptive Gaussian filter and estimate the amount of noise. It computes the standard deviation of each block and estimation is performed on pixel-based operation. The proposed algorithm divides an input image into blocks. This method calculates the standard deviation of each block and finds the minimum standard deviation block. The block in flat region shows well noise and filtering effects. Blocks which have similar standard deviation are selected as test blocks. These pixels are filtered by adaptive Gaussian filtering. Then, the amount of noise is calculated by the standard deviation of the differences between noisy and filtered blocks. Experimental results show that our proposed estimation method has better results than those by existing estimation methods.

A Review on Motion Estimation and Compensation for Versatile Video Coding Technology (VVC)

  • Choi, Young-Ju;Kim, Byung-Gyu
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.7
    • /
    • pp.770-779
    • /
    • 2019
  • Video coding technologies are progressively becoming more efficient and complex. The Versatile Video Coding (VVC) is a new state-of-the art video compression standard that is going to be a standard, as the next generation of High Efficiency Video Coding (HEVC) standard. To explore the future video coding technologies beyond the HEVC, numerous efficient methods have been adopted by the Joint Video Exploration Team (JVET). Since then, the next generation video coding standard named as VVC and its software model called VVC Test Model (VTM) have emerged. In this paper, several important coding features for motion estimation and motion compensation in the VVC standard is introduced and analyzed in terms of the performance. Improved coding tools introduced for ME and MC in VVC, can achieve much better and good balance between coding efficiency and coding complexity compared with the HEVC.

PIXE Analysis of Aerosol Particles - Preparation of Standard Samples and Calibration Test - (PIXE 분석에 의한 대기에어로졸의 원소분석 -표준시료의 작성 및 정량화-)

  • 崔琴簒
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.114-118
    • /
    • 1991
  • Particle Induce X-Ray Emission (PIXE) analysis is one of the most useful methods which can determine the elemental concentration of aerosol particles in nano-gram range. The main purpose of this paper is to establish the measurement system and the procedure of PIXE analysis. The standard samples were prepared to calibrate the PIXE analysis by three different techniques. The linear relationships between the peak counts from PIXE spectra and the mass density from RBS spectra were obtained for each standardized element under the applied measurment geometry and conditions. The sensitivity curves for PIXE analysis were determined from these relationships.

  • PDF

Reliability of Three Methods for Measuring Length of Iliotibial Tract (엉덩정강근막띠의 길이 평가를 위한 세 가지 측정방법들의 신뢰도 비교)

  • Kim, Moon-Hwan;Yun, Sung-Joon;Weon, Jong-Hyuck
    • Physical Therapy Korea
    • /
    • v.21 no.3
    • /
    • pp.20-27
    • /
    • 2014
  • The purpose of this study was to compare the intra-rater and inter-rater reliability of three methods for measuring iliotibial tract length in 40 knees of 20 subjects. The measurements were performed by two examiners and one assistant. The length of the iliotibial tract was measured using three methods: the first used a modified Ober test with an inclinometer, the second used a modified Ober test with a marker, and the third used active adduction test with a marker in the supine position. Each examiner used the three methods in two sessions. For the first method, the inclinometer value was recorded manually. For the second and third methods, Image J analysis software was used to analyze the photographs taken. The intra-rater and inter-rater reliability of the measured value was assessed by means of intra-class correlation coefficients [ICC (3,1)] and the standard error of measurement. The intra-rater reliabilities of the three methods were excellent (ICC=.97, .95, and .94, respectively), and the inter-rater reliabilities of the first and second methods were fair to good (ICC=.64 and .65, respectively). The inter-rater reliability of the third method was excellent (ICC=.88). Our results suggest that the active adduction test is an objective and qualitative measurement method for measuring iliotibial tract length. We recommend that the active adduction test be used for measuring iliotibial tract length in the clinical setting.

Sign IV Cointegration Tests

  • Oh, Yu-Jin
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.4
    • /
    • pp.707-711
    • /
    • 2009
  • We propose new cointegration tests using signs of the regressors as instrumental variable. Our tests have the asymptotic standard normal distribution and are free from the dimension of regressors under the null hypothesis of no cointegration. A Monte-Carlo simulation shows that the proposed tests have a stable size and an improved power. Particulary, the tests have better power for small numbers of observations.