• Title/Summary/Keyword: Standard normal Distribution

Search Result 322, Processing Time 0.021 seconds

Biosafety of Microbiological Laboratories in Korea (우리나라 미생물 실험실의 생물안전현황)

  • Eun, Sang-Jun;Park, Ki-Dong;Kim, Jong-Kyun;Im, Jeong-Soo;Hwang, Yoo-Sung;Kim, Yong-Ik;Lee, Jin-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.38 no.4
    • /
    • pp.449-456
    • /
    • 2005
  • Objectives : The biosafety level (BSL) practiced in microbiology laboratories in Korea according to the laboratory biosafety manual published by the World Health Organization (WHO) was evaluated using the data obtained by a survey. Methods : Under the advise of Clinical Laboratory Physicians, 144 types of microorganisms were screened based on the guidelines of biosafety in microbiological and biomedical laboratories published by the US Center for Disease Control and Prevention and classified into 1-4 risk groups. A questionnaire containing 21 questions in 5 areas was developed using the biosafety manual by published WHO. Of the 1,876 different organizations sent the survey, 563 responded to the survey (response rate: 30.0%). The species of microoganisms handled by as well as the biosafety level in microbiology laboratories were analyzed. Results : There were 123 species of microorganisms handled in microbiology labs in Korea. The BSL required in 512 microbiology labs was answered by the survey responders as the first grade in 33 labs (6.4%), 2nd in 437 (85.4%), 3rd in 42 (8.2%), and 4th in none. The average number of items satisfied was 12.2, showing only a 57.9% satisfactory rate and normal distribution. Conclusions : The state of overall observance of BSL in most microbiology labs of Korea was evaluated as lagging compared with the standard set up by WHO. Therefore, the Korean government need to produce and distribute a biosafety manual in microbiology laboratories and make efforts to prevent this threat through measures such as training in biosafety in microbiology labs.

Design and Fabrication of $8{\times}8$ Foveated CMOS Retina Chip for Edge Detection (물체의 윤곽검출을 위한 $8{\times}8$ 방사형 CMOS 시각칩의 설계 및 제조)

  • Kim, Hyun-Soo;Park, Dae-Sik;Ryu, Byung-Woo;Lee, Soo-Kyung;Lee, Min-Ho;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.91-100
    • /
    • 2001
  • A $8{\times}8$ foveated (log-polar) retina chip for edge detection has been designed and fabricated using CMOS technology. Retina chip performs photo-input sensing, edge extraction and motion detection and we focused edge extraction. The pixel distribution follows the log-polar transform having more resolution in the center than in the periphery and can reduce image information selectively. This kind of structure has been already employed in simple image sensors for normal cameras, but never in edge detection retina chip. A scaling mechanism is needed due to the different pixel size from circumference to circumference. A mechanism for current scaling in this research is channel width scaling of MOS transistor. The designed chip has been fabricated using standard $1.5{\mu}m$ single-poly double-metal CMOS technology.

  • PDF

Comparison analyzation of Calculation Equations for Shear strength of Steel Plate Coupling Beam (철골 플레이트 커플링보의 전단강도에 대한 기준식의 비교.분석)

  • Lee, Kyung-Hwun;Song, Han-Beom;Park, Jin-Young;Yi, Waon-Ho;Tae, Kyung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.129-132
    • /
    • 2008
  • Coupled shear wall system is the primary seismic load resisting system of buildings. The coupling beam of these buildings must exhibit excellent ductility and energy dissipation capacity. To achieve better ductility and energy dissipation, the steel coupling beam embedded in the reinforced concrete walls is proposed. Performance of the steel coupling beam is mainly effected by embedment length. ACI equation and BS equation were examined with 23 previous test results. The statistical study uses the values of mean value, standard deviation, correlation coefficient, normal distribution curve, and error analysis. Through the analytical program, the evaluation of the 2 equations was established.

  • PDF

A Study on the HEC(Hybrid ESE-Conductor) Method for Lightning Protection of Buildings (건축물의 낙뢰보호를 위한 HEC(Hybrid ESE-Conductor) 방식에 관한 연구)

  • Kim, Dong-Jin;Kim, Young-Sun;Lee, Ki-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.146-152
    • /
    • 2008
  • The frequency of lightning is increased due to improbable weather condition and global wanning. This phenomenon increases economical damage as well as human damage. Advanced countries like europe and north america have applied the facility standard of lightning by accumulating a store of quantitative data about lightning research. Lightning facility is composed of the lightning accepting part for induction lightning, ground connected electrode which conducts lightning current. The lightning accepting part is composed of normal rod, horizontal conductor, ESE lightning rod. Moreover, lightning accepting part is taken to use by the method of protection. This paper suggests HEC(Hybrid ESE-Conductor) method which mixes horizontal conductor and ESE lightning rod. This is also discovered by experiment that the starting point of corona discharge current is low, so it is efficient for lightning protection comparing with other methods. Moreover, distribution of electric field is analyzed qualitatively by finite element method. It also results in the relation of the starting point of corona discharge current. Corona discharge current makes minute current about some ${\mu}A$ between the electrodes by the strength of electric field. Also it occurs insulation destruction of gas, and it is developed to the shape of streamer by increase of the strength of electric field. We can find that the initial occurrence of streamer and contact probability of lightning can have advantage after researching the starting point of corona discharge current and discharge current of lightning striking point. This research demonstrates that the suggested HEC method is economically competitive as a lightning protection facility, and it takes a capably perfect role.

Reliability-based Design Optimization using Multiplicative Decomposition Method (곱분해기법을 이용한 신뢰성 기반 최적설계)

  • Kim, Tae-Kyun;Lee, Tae-Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.4
    • /
    • pp.299-306
    • /
    • 2009
  • Design optimization is a method to find optimum point which minimizes the objective function while satisfying design constraints. The conventional optimization does not consider the uncertainty originated from modeling or manufacturing process, so optimum point often locates on the boundaries of constraints. Reliability based design optimization includes optimization technique and reliability analysis that calculates the reliability of the system. Reliability analysis can be classified into simulation method, fast probability integration method, and moment-based reliability method. In most generally used MPP based reliability analysis, which is one of fast probability integration method, if many MPP points exist, cost and numerical error can increase in the process of transforming constraints into standard normal distribution space. In this paper, multiplicative decomposition method is used as a reliability analysis for RBDO, and sensitivity analysis is performed to apply gradient based optimization algorithm. To illustrate whole process of RBDO mathematical and engineering examples are illustrated.

Effect of Random Dopant Fluctuation Depending on the Ion Implantation for the Metal-Oxide-Semiconductor Field Effect Transistor (금속-산화막-반도체 전계효과 트랜지스터의 불순물 분포 변동 효과에 미치는 이온주입 공정의 영향)

  • Park, Jae Hyun;Chang, Tae-sig;Kim, Minsuk;Woo, Sola;Kim, Sangsig
    • Journal of IKEEE
    • /
    • v.21 no.1
    • /
    • pp.96-99
    • /
    • 2017
  • In this study the influence of the random dopant fluctuation (RDF) depending on the halo and LDD implantations for the metal-oxide-semiconductor field effect transistor is investigated through the 3D atomistic device simulation. For accuracy in calculation, the kinetic monte carlo method that models individual impurity atoms and defects in the device was applied to the atomistic simulation. It is found that halo implantation has the greater influence on RDF effects than LDD implantation; three-standard deviation of $V_{TH}$ and $I_{ON}$ induced by halo implantation is about 6.45 times and 2.46 times those of LDD implantation. The distributions of $V_{TH}$ and $I_{ON}$ are also displayed in the histograms with normal distribution curves.

Estimation of Extreme Tide for Risk Analysis of Marine Salvage in the Namhae (southern sea of Korea) (한국 남해의 구난환경 위험성 분석을 위한 극치 조석 산정)

  • Lee Moon-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.1 s.24
    • /
    • pp.33-38
    • /
    • 2006
  • In marine salvage, extreme tide heights and tidal currents are necessary to anchor an accidental ship. In order to meet this requirement, a simple scheme was developed which yields the spatial informations on the extreme tide from the distribution of approximate highest astronomical tide heights using a relationship between extreme and highest astronomical tides at the standard port. This method is the inference method based on horizontally homogeneity of tide. This scheme was applied to estimate extreme tide heights and tidal currents in the Namhae (southern sea of Korea). The highest astronomical tide heights are computed by amplitude of four major constituents (M2, S2, K1, O1 tide). The estimated extreme tide heights are ranged from 70 to 260 cm for return period 50 years and from 80 to 270cm for return period 100 years, respectively. For return period 100 years, extreme tidal currents show value of 1.55 times as strong as those of normal state.

  • PDF

Measuring the Relative Risk Aversion Coefficients of Apple Farmers (사과 농가의 상대위험회피계수 추정)

  • Lin, Qing-Long;Yeo, Jun-Ho;Kim, Tae-Kyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1036-1044
    • /
    • 2015
  • This paper estimates the relative risk aversion coefficients of apple farmers. Two hypothetical situations are designed and two-stage questionnaires are conducted for each situation. A utility function that has constant relative risk aversion was used, and it was assumed that the relative risk aversion coefficients follow a log-normal distribution. To reduce the hypothetical bias, the data was collected from repetitive questions. As a result, the mean and standard deviation of the relative risk aversion coefficients of apple farmers was 10.915 and 7.516, respectively. The relative risk aversion coefficients conditional on a survey response in each category were also measured. These findings can be used as parameters to analyze the effects of risk management tools.

Effect of Acupuncture at the Field of the Auricular Branch of the Vagus Nerve on Autonomic Nervous System Change (미주신경 감각분지 분포영역의 자침이 자율신경 변화에 미치는 영향)

  • An, Sunjoo;Keum, Dongho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.31 no.2
    • /
    • pp.81-97
    • /
    • 2021
  • Objectives This study was designed to identify the changes of autonomic nervous system (ANS) which was induced by acupuncture at the field of the auricular branch of the vagus nerve. Methods 30 healthy adults were selected and classified into two groups; experimental group, control group. After providing mental stress, acupuncture was applied at external ear in experimental group and no treatment executed in control group. The evaluation of ANS function was measured by heart rate variability (HRV). We statically analyzed the difference of HRV parameters which include mean heart rate (MHRT), standard deviation of all N-N intervals (SDNN), square root of the mean of the sum of the squares of differences between adjacent N-N intervals (RMSSD), total power (TP), low frequency power (LF), high frequency power (HF), LF/HF ratio. Results All subjects showed significant increase in SDNN, LF after stress stimulation (p<0.05). Immediately after intervention, MHRT was significantly decreased (p<0.001) and RMSSD, HF were significantly increased in experimental group (p<0.05). After the end of intervention, SDNN, HF, RMSSD, TP, LF were significantly increased in experimental group (p<0.01, p<0.05). And when comparing baseline HRV, SDNN, LF were significantly increased in control group (p<0.01) and SDNN, RMSSD, TP, LF were significantly increased in experimental group (p<0.05). In the subgroup analysis, normal balance of ANS group showed significant increase in TP, LF, SDNN, HF (p<0.01, p<0.05). Conclusions We suggested that acupuncture at external ear, region of the vagus nerve distribution could increase parasympathetic activity and cause changes and reregulation of the ANS.

Study of surgical anatomy of portal vein of liver segments by cast method and its clinical implications

  • Shrikantaiah, Vidya C.;Basappa, Manjaunatha;Hazrika, Sangita;Ravindranath, Roopa
    • Anatomy and Cell Biology
    • /
    • v.51 no.4
    • /
    • pp.232-235
    • /
    • 2018
  • Portal vein provides about three-fourths of liver's blood supply. Portal vein is formed behind the neck of pancreas, at the level of the second lumbar vertebra and formed from the convergence of superior mesenteric and splenic veins. The purpose of this study is to review the normal distribution and variation, morphometry of portal vein and its branches for their implication in liver surgery and preoperative portal vein embolization. It is also helpful for radiologists while performing radiological procedures. A total of fresh 40 livers with intact splenic and superior mesenteric vein were collected from the mortuary of Forensic Department, JSS Medical College and Mysuru Medical College. The silicone gel was injected into the portal vein and different segments were identified and portal vein variants were noted. The morphometry of portal vein was measured by using digital sliding calipers. The different types of portal vein segmental variants were observed. The present study showed predominant type I in 90% cases, type II 7.5% cases, and type III 2.5% cases. Mean and standard deviation (SD) of length of right portal vein among males and females were $2.096{\pm}0.602cm$ and $1.706{\pm}0.297cm$, respectively. Mean and SD of length of left portal vein among males and females were $3.450{\pm}0.661cm$ and $3.075{\pm}0.632cm$, respectively. The difference in the Mean among the males and females with respect to length of right portal vein and left portal vein was found to be statistically significant (P=0.010). Prior knowledge of variations regarding the formation, termination and tributaries of portal vein are very helpful and important for surgeons to perform liver surgeries like liver transplantation, segmentectomy and for Interventional Radiologists.