• Title/Summary/Keyword: Standard fire test

Search Result 295, Processing Time 0.024 seconds

A Study on the Effective Method to Producing Data for The ROKA Live Fire Training Range Safety (한국군 실 사격 훈련간 효율적인 안전지대 데이터 구축 방안 연구)

  • Lee, June-Sik;Choi, Bong-Wan;Oh, Hyun-Seung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.3
    • /
    • pp.64-77
    • /
    • 2015
  • An effective method for produce munitions effectiveness data is to calculate weapon effectiveness indices in the US military's Joint Munitions Effectiveness Manuals (JMEM) and take advantage of the damage evaluation model (GFSM) and weapon Effectiveness Evaluation Model (Matrix Evaluator). However, a study about the Range Safety that can be applied in the live firing exercises is very insufficient in the case of ROK military. The Range Safety program is an element of the US Army Safety Program, and is the program responsible for developing policies and guidance to ensure the safe operation of live-fire ranges. The methodology of Weapon Danger Zone (WDZ) program is based on a combination of weapon modeling/simulation data and actual impact data. Also, each WDZ incorporates a probability distribution function which provides the information necessary to perform a quantitative risk assessment to evaluate the relative risk of an identified profile. A study of method to establish for K-Range Safety data is to develop manuals (pamphlet) will be a standard to ensure the effective and safe fire training at the ROK military education and training and environmental conditions. For example, WDZs are generated with the WDZ tool as part of the RMTK (Range Managers Tool Kit) package. The WDZ tool is a Geographic Information System-based application that is available to operational planners and range safety manager of Army and Marine Corps in both desktop and web-based versions. K-Range Safety Program based on US data is reflected in the Korean terrain by operating environments and training doctrine etc, and the range safety data are made. Thus, verification process on modified variables data is required. K-Range Safety rather than being produced by a single program, is an package safety activities and measures through weapon danger zone tool, SRP (The Sustainable Range Program), manuals, doctrine, terrain, climate, military defence M&S, weapon system development/operational test evaluation and analysis to continuously improving range safety zone. Distribution of this K-range safety pamphlet is available to Army users in electronic media only and is intended for the standing army and army reserve. Also publication and distribution to authorized users for marine corps commands are indicated in the table of allowances for publications. Therefore, this study proposes an efficient K-Range Safety Manual producing to calculate the danger zones that can be applied to the ROK military's live fire training by introducing of US Army weapons danger zone program and Range Safety Manual

A Study on the Toxic Gases and Smoke Hazard of PASCON Trough (파스콘 트로프의 연기유독성에 관한 연구)

  • Lee, Chang-Woo;Hyun, Seong-Ho;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research is to estimate the effect of smoke and combustion gases on humane body indirectly through measuring the toxicity of those. For this purpose, the toxic index of smoke and combustion gases was investigated by smoke hazard test and analysis of smoke which were conducted by KS F 2271 and NES 713 method respectively. It i s proved by KS F 2271 method that PASCON trough is suitable to the testing standard of interior material and construction of building. In addition, it is identified by NES 713 method that combustion gases occurring in PASCON product were only carbon dioxide and carbon monoxide, and the smoke index of those was 0.944. This value means that the hazard effect of smoke gases on humane ! body can possibly happens when exposed to the smoke gases for more than 30 min. In aspect of the domestic situation that have not regulated the hazard estimation and the emissions of smoke when the flame retarding ability of the products have been requested, the toxic indexes of PASCON products are comparatively low.

An Experimental Study on the Ventilation Performance to Enhance Removal Efficiency of Indoor Hamful Gases (실내 유해가스 제거효율 향상을 위한 환기성능에 관한 실험적 연구)

  • Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.117-124
    • /
    • 2009
  • The objective of this research is to analyze the ventilation performance of mechanical ventilation systems to enhance removal efficiency of indoor hamful gases. The ventilation performance is evaluated using a step-down method based on ASTM Standard E741-83. The ventilation performance is evaluated as a function of the ventilation rate and supply/extract locations using a tracer gas ($CO_2$) technique. As a result, the $CO_2$ concentration as a function of time is decayed exponentially and the ventilation performance is found to increase with increased the ventilation rate. The ventilation performance of the second type ventilation system is better than that of the first type or the third type. The ventilation performance without human occupancy increases up to 55% and the ventilation performance with one person increases up to 25% at the supply air of 570Lpm comparing with a natural reduction after one hour in the test chamber. The ventilation performance is better than 15% comparing with natural decay at the supply of 570Lpm in an office room.

Comparison of Video Laryngoscope and Direct Laryngoscope on Rapidity and Accuracy in Tracheal Intubation by Paramedic (1급 응급구조사의 비디오후두경 기관삽관과 직접후두경 기관삽관의 신속성 및 정확도 비교)

  • Sim, Gyu-Sik
    • The Korean Journal of Emergency Medical Services
    • /
    • v.14 no.1
    • /
    • pp.5-18
    • /
    • 2010
  • Objective : This study compares Video laryngoscope and Direct laryngoscope in tracheal Intubation on rapidity and accuracy by paramedic and aims to improve efficiency of airway management and survival rate in pre-hospital treatment for the patients with severe trauma, cardiac arrest or dyspnea caused by acute diseases. Methods : 60 paramedics were recruited from 13 fire stations located in C province. With the consent of the paramedics, likelihood ratio test was carried out and they were divided into two different groups; DL group (30) and GVL group (30). Regarding intubation conditions, difficult airway grade I, grade II and grade III as well as sniffing position and neutral position were examined. This study also compared between ambulance in motion and in stand still. Frequency, average and standard deviation were analyzed with statistics program, SPSS WIN 17.0 and repeated measure design was introduced to examine inter-relations between position, grade and groups. Results : Intubation was performed more rapidly in neutral position and GVL than in sniffing position and DL(F = 15.260, p = .000). Rapidity value was better with grade I and grade II than grade III and better with GVL than DL(F = 32.629, p = .000). Accuracy value was higher with neutral position and GVL than sniffing position and DL(F = 5.008, p = .011). grade III was less accurate than grade I, grade II and GVL was more accurate than DL(F = 10.966, p = .000). Ambulance motion status did not show any statistically significant differences in accuracy and rapidity. Conclusion : Given this study results, neutral position is better for the patient with severe trauma. For a better survival, GVL intubation can be considered since GVL can enhance accuracy as well as rapidity regarding difficult airway. Since there is no significant differences in ambulance motion factors, intubation can be recommended even in moving ambulance for shortening traveling time to a hospital.

  • PDF

Mechanical Properties of High Stiffness Shear Connector (고강성 스터드볼트의 역학적 특성에 관한 연구)

  • Eom, Chul-Hwan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.491-496
    • /
    • 2015
  • The headed studs used extensively for steel-composite construction are specified as SS400 in the current Korean Standard specification considering the welding condition. And the corresponding equation for the shear force calculation is limited for the use of compression strength of concrete below $300kgf/cm^2$. However, it is expected that the high strengthening and precasting of both steel and concrete due to the necessity of shear connector or other connecting material for the combination of steel and concrete. Therefore, the experimental results obtained during the development process of high strength stud for the connection of high strength concrete and the steel member are reported in this paper. Also the effectiveness of newly developed shear connector using pipe(pipe stud) to increase the stiffness of a stud is verified by comparing both the stiffness and the strength with common stud bolt through the welding ability, mechanical characteristics and experimental investigation.

A Study on High Strength Concrete of Concrete Filled Steel Tube Column (CFT 기둥용 초고강도 충전콘크리트에 관한 연구)

  • Jung, Keun-Ho;Lim, Nam-Gi;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.127-132
    • /
    • 2004
  • CFT(Concrete Filled Steel Tube) is a structure of circular or squared of steel column filled with concrete. The steel tube holds the concrete inside and that makes this structure to perform superior features on stiffness, proof stress, transformation, fire resistance and construction itself. In this study, by over the 800kgf/$\textrm{cm}^2$ of high strength concrete for CFT column, research has been done on the basic property of matter such as fluidity, resistance on segregation, compressive strength, setting icons of the concrete filled in the steel tube under conditions of standard weather. Physical properties of concrete for CFT that Concrete with silica fume, fly ash of air entraining and high-range water reducing agent, that used to CFT column research purpose to find the most ideal composition, which is achieved by the investigation in the concrete's property of matter like ability of Slump, Slump Flow, Air content, Bleeding, and Settlement. For this study, experiments which are bused on obtained the result through physical test are practiced, with all of the experiment, specimens only for control are produced in each method of curing and analyzed to relations with core strength in mock-up test. In mock-up test, the research is studied compactability of concrete filled in tube and degree of hydration hysteresis, as a basic reference for applying to field of CFT column which is used over 800kgf/$\textrm{cm}^2$ high strength concrete.

Heat Dissipation Design for KW Class Power Control Unit Mounted on Aircraft Store (항공기 장착물에 탑재되는 KW급 전력변환장치의 방열설계)

  • Choi, Seok-min;Kim, Hyung-jae;Jung, Jae-won;Lee, Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.4
    • /
    • pp.261-266
    • /
    • 2020
  • When a KW-class power control unit is installed in an aircraft installation, a heat dissipation design for a large amount of heat generated during power conversion should be considered. Failure to provide adequate heat dissipation can lead to equipment malfunction and fire, which can be a fatal factor in aviation operations. This paper describes the heat dissipation design of a KW-class power control unit installed in aircraft installation. The design and manufacturing test were conducted through computerized analysis, and the analysis model was corrected by confirming the rapid heat generation phenomenon of the heating element due to high power control. After the model revision, the design was improved, and the high-temperature operation test of the US military standard MIL-STD-810G was performed to confirm the feasibility of the improved design.

Quality comparison of musk products using a chromatographic pattern analysis (사향의 크로마토그램 패턴 분석을 통한 품질비교 연구)

  • Cho, Chong Woon;Gao, Dan;Kang, Jong Seong;Jung, Hyo won;Park, Yong-Ki
    • The Korea Journal of Herbology
    • /
    • v.36 no.4
    • /
    • pp.41-50
    • /
    • 2021
  • Objectives : This study is to check the quality of Moschus products in Korean markets using a chromatographic analysis. Methods : We collected musk products, two genuine products from Russia (A, B), two authentic products from Hong Kong (C) and Korea (D), the Ministry of Food and Drug Safety (MFDS) standard (E), and two fire ants products (E, F). Results : For identification, TLC analysis of 60% ethanol extracts of each product showed that A, B, C, and E have the suitable patterns before color development at 365 nm UV light for the MFDS regulation in Korea. A clear red spot was observed from the E at Rf 0.6 with 365 nm UV light after color development, but this spot was not found in A and B. For the purity test, a distinct violet spot with Rf 0.87 was observed from the A and B in TLC analysis of methanol extracts of each product at white light, however, this spot was not matched with the impurities of E and F. In HPLC-UV pattern analysis, a similar peak pattern was shown in A, B and E, and similar peaks were observed C, although the similarity was weaker than that of A, B, and E. The F and G showed different peak patterns compared with the peak patterns of other samples. Conclusions : Hence, it is considered that the test methods need flexibility in application for identification and purity test depending on the type of sample.

Airborne Sound Insulation Performance of Window and Indoor Noise Level in the Balcony Expanded Apartments

  • Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.61-67
    • /
    • 2015
  • Purpose: The balcony in the apartment is important space not only as a fire escape but also as a buffer for heat and sound insulation. However, with the legalization of balcony expansion for residential apartments in Korea in 2006, many households have eliminated the balcony space altogether to increase the inner space, often without sufficient consideration for the effects on the indoor environment. This study examined the sound insulation performance of exterior-facing windows in enclosed balconies and the changes in the indoor acoustic environment due to expansion to provide a basis for appropriate balcony expansion. The apartments for the field test were chosen where two balcony types can be compared, and the sound insulation performance for the eighteen balcony windows was measured. The windows installed were typical double window with thickness 16 mm or 22 mm. Measurements of the weighted standard sound pressure level difference showed a decrease of about 3 dB in sound insulation performance due to expansion. For common exterior noise levels of 70-85 dB(A), the indoor noise level can exceed 45 dB(A), the limit level regulated in Korea. However, it was found that the sound insulation performance of the window and the quality of the construction have more influence on indoor noise levels than balcony expansion itself.

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • Yoon, Hun-Ju;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC 600[V] wire. Messurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflaming pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of $2.5{\pm}0.04[w/cm^{2}]$ for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomplete combustion of FR-PVC which has high content of carbon in compound.

  • PDF