• Title/Summary/Keyword: Standard curve

Search Result 1,265, Processing Time 0.029 seconds

A Study on the Evaluation of the Pipe Fracture Characteristic (실배관 파괴특성 평가에 관한 연구)

  • Park Jae-Sil;Kim Young-Jin;Seok Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.1 s.232
    • /
    • pp.107-114
    • /
    • 2005
  • In order to analyze the elastic-plastic fracture behavior of a structure, the fracture resistance curve of the material should be known first. The standard CT specimen was used to obtain the fracture resistance curves of a piping system. However, it is known that the fracture resistance curve by the standard CT specimen is very conservative to evaluate the integrity of a structure. Also the fracture resistance curve is effected by the specimen geometry and the dimensions because of the constraint effect. The objective of this paper is to be certain the conservativeness of the fracture resistance curve by the standard CT specimen and to provide an additional safety margin. For these, the fracture tests using a real pipe specimen and the standard CT specimen test were performed. A 4-point bending jig was manufactured for the pipe test and the direct current potential drop method was used to measure the crack extension and the length for the pipe test. Also finite element analyses were performed with a CT specimen and a pipe in order to prove the additional safety margin. From the result of tests and analyses of the pipe and the standard CT specimen, it was observed that the fracture analysis with the standard CT specimen is conservative and the additional safety margin was proved.

A Study on The Tooth Creating Algorithms of The Cycloid Curve Gear and The Third Polynomial Curve Gear (사이클로이드 곡선 및 3차 다항식 곡선기어의 치형 설계에 관한 연구)

  • 최종근;윤경태
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.3
    • /
    • pp.80-85
    • /
    • 2002
  • The free curve gear is a non-circular gear without any relating center, which can perform free curve motion for complicated mechanisms, and minimize the work area. In this study, an algorithms for tooth profile generation of free curve involute gear is developed. The algorithm uses the involute gear creating principle in which a gear can be generated by rolling with another standard involute one. Cycloid me and third polynomial curve gears were designed and verified by computer graphics. These gears are manufactured in the wire-cut EDM and examined in engagement with a standard spur gear. The results showed that the proposed algorithm is successful to design and to manufacture the free curve gear with concave and convex profiles.

Standard Curve Validation using Trendlines in Excel (Excel의 추세선을 이용한 표준곡선 검증)

  • Lee, Kyung-Hwa;Park, Hyung-Ki;Shin, Young-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.69-74
    • /
    • 2016
  • Purpose Using a regression formula of the trendline near the coefficient of determination (R2) "1" by substituting the dependent variable of the standard curve to calculate the values of the independent variable. To determine the suitability of a regression equation by comparing the difference between the independent variables of the standard curve and the predicted independent variables. Materials and Methods Perkin Elmer Gamma-Counter machine was used for Standard curve of regression methods. TSH. TG-Ag (Thyroglobulin Antigen), Insulin that used materials and method test to compare the result from the Excel trendline of the regression formula. Results Each of the value of coefficient of determination ($R^2$) and Trendline $R^2=1$, Polynomial Trendline for TSH, $R^2=1$, Polynomial Trendline for TG-Ag, $R^2=0.9994$, Polynomial Trendline for Insulin. Conclusion We confirmed that IRMA immune method is found to the nearest trends elected a standard curve using polynomial trendline. The independent variables to predict the trend by using a polynomial trendline formula containing the error was a limitation.

  • PDF

Estimation of the Fracture Resistance Curve for the Nuclear Piping Using the Standard Compact Tension Specimen (표준 CT시험편을 이용한 실배관 파괴저항 곡선 예측)

  • Park, Hong-Sun;Heo, Yong;Koo, Jae-Mean;Seok, Chang-Sung;Park, Jae-Sil;Cho, Sung-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.9
    • /
    • pp.930-937
    • /
    • 2009
  • The estimation method of the fracture resistance curve for the pipe specimen was proposed using the load ratio method for the standard specimen. For this, the calculation method of the load - CMOD curve for the pipe specimen with the common format equation(CFE) was proposed by using data of the CT specimen. The proposed method agreed well with experimental data. The J-integral value and the crack extension were calculated from the estimated load - CMOD data. The fracture resistance curve was estimated from the calculated J-integral and the crack extension. From these results, it have been seen that the proposed method is reliable to estimate the J-R curve of the pipe specimen.

Evaluation of Fatigue Life Characteristic of a Real Waterwork Pipe Using the Probability Density Function (확률밀도함수를 이용한 상수도 실 배관의 피로수명 특성 평가)

  • Choi, Jung-Hun;Koo, Jae-Mean;Seok, Chang-Sung;Song, Weon-Keyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.707-712
    • /
    • 2008
  • The fatigue characteristics of a material or a structure are generally derived from fatigue tests of standard specimens. However, test results of standard specimens are different from those of real structures or components. Therefore, to calculate more accurate fatigue life, the geometrical effect and surface condition must be considered by comparing test results of standard specimens with those of real structures or components. Thus the object of this paper is to evaluate the fatigue characteristics of a real waterwork pipe. Also, to evaluate fatigue characteristic based on life distribution, the statistical fatigue characteristics were analyzed by the normal distribution and related data of P-S-N curve.

Study of Standard Design Fire Curve of Various Railcar (철도차량별 표준 설계화재곡선 연구)

  • Lee, Duck-Hee;Park, Won-Hee;Jung, Woo-Sung;Kim, Chi-Hun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1426-1431
    • /
    • 2011
  • A study on the standardization of design fire HRR(heat release rate) curve was conducted for various railcar from the fire simulation or the fire tests. These standard curves are listed on the tunnel fire safety manual which will be used for the QRA(quantitative risk analysis) process of the long railway tunnels. The design fire curve is based with four simple factor representing the key of fire curve characteristics. Flashover time, maximum HRR and burn out time are the key factors of the design fire curve. Specially total heat release is decided by the burnable material amount in the car.

  • PDF

Development and Application of Coliform Load Duration Curve for the Geum River (금강에 대한 대장균 부하 지속곡선의 개발 및 적용)

  • Kim, Geonha;Yoon, Jaeyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.516-519
    • /
    • 2005
  • An useful protocol coiled load duration curve methodology to estimate contaminant loading to a river on an exceedance probability scale was developed in this research. The technique was further applied to estimate total coliform loading to the Geum River, using the daily mean flow rate and total coliform concentration data during January, 1996 and July, 2004 for the Gongju where an automated monitoring station is located. Drought flow of the Gongju (=50.3 cms) was equivalent to 40% on an exceedance probability scale. Load duration curve for total coliform loading at the Gongju was constructed. Standard duration curve was constructed with the water quality criteria for the class 2 (total coliform concentration = 1000 MPN/100 mL). By plotting load duration curve with standard duration curve, it could be revealed that water quality do not meet the desired water quality for 47% on an exceedance probability scale. If linearity between flow rate and coliform concentration is assumed, it can be interpretated that water quality exceeds desired criteria when average mean flow rate is over 51 cms.

Evaluation of Fatigue Life Characteristic of a Real Waterwork Pipe Using the Probability Density Function (확률밀도함수를 이용한 상수도 실 배관의 피로수명 특성 평가)

  • Choi J.H.;Park J.S.;Seok C.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1691-1694
    • /
    • 2005
  • The fatigue characteristic of a material or a structure is derived from fatigue tests of standard specimens. However test results of standard specimens are very different from those of real structures or components. Therefore, to calculate more accurate fatigue life, the geometrical effect and surface condition must be considered by comparing test results of standard specimens with those of real structures or components. Thus the object of this paper is to evaluate the fatigue characteristic of a real waterwork pipe by conducting fatigue tests with standard specimens and non-standard(plate-shaped) specimens of base metal and weld metal. Also, to evaluate fatigue characteristic based on life distribution, statistical fatigue characteristic was analyzed by the normal distribution and related data of P-S-N curve.

  • PDF

Simplified Evaluation Method for Residual Bond Strength of Reinforced Concrete Using Standard Fire Curve (표준화재곡선을 이용한 잔존부착강도 평가 간략방법 제안)

  • Moon, Do-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.41-47
    • /
    • 2010
  • For the enhancement of structural safety of thermally damaged reinforced concrete structure, rapid evaluation of damage in the structure is very important. This study addresses a simplified method which is equivalent to the standard fire curve (ISO 834) for the residual bond strength evaluation. In the proposed method, a exposure duration as well as the maximum temperature can be considered. For the comparisons with conventional methods, concrete properties obtained from the report of Daegu subway fire accident were referred and the results support the applicability of the proposed method in this study.

Evaluation of Impaired Waterbody and Multivariate Analysis Using Time Series Load Curve -in Jiseok Stream Watershed- (시계열 부하 곡선을 이용한 수체손상 평가 및 다변량 분석 -지석천 유역을 대상으로-)

  • Park, Jinhwan;Kang, Taewoo;Han, Sungwook;Baek, Seunggwon;Kang, Taegu;Yoo, Jechul;Kim, Youngsuk
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.650-660
    • /
    • 2017
  • In this study, pollutant emission characteristics by water damage period analyzed 11 items (water temperature, pH, DO, EC, BOD, COD, TOC, SS, T-N, T-P and flow) with load duration curve, time series load curve and factor analysis for three years (2014-2016). Load duration curve is applied to judge the level of impaired waterbody and estimate impaired level by pollutants such as BOD and T-P in this study depending on variation of stream flow. Water quality standard exceeded the flow of mid-range and low-range by flow condition evaluation using load duration curve. This watershed was influenced by point source more than non-point source. Cumulative excess rate of BOD and T-P kept water quality standard for all seasons (spring, summer, autumn and winter) except BOD 59% in spring. Water quality changes were influenced by pollutants of basic environmental treatment facilities and agricultural areas during spring and summer. Results of factor analysis were classified commonly first factor (BOD, COD, and TOC) and second factor (flow, water temperature and SS). Therefore, effects of artificial pollutants and maintenance water must be controlled seasonally and reduced relative to water damage caused by point pollution sources with effluent standard strengthened in the target watershed.