• Title/Summary/Keyword: Standard body measurement

Search Result 266, Processing Time 0.028 seconds

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

Studies on the Physical Growth and Development, Standard Body Weight and Normal Adapted Body Weight in Korea (한국인의 표준체중치와 정상적응체중치에 관한 연구)

  • 김대봉;윤태영;최중명;박순영
    • Korean Journal of Health Education and Promotion
    • /
    • v.13 no.1
    • /
    • pp.128-162
    • /
    • 1996
  • Using Random Sampling, the authors measured the body heights and weights of 31,151 persons - 17,102 in males and 14,049 in females from metropolitan, urban and rural areas between 6 to over 80 year old - for the purpose of investigating the type and the actual condition of the Korean's growth and development. At first, on the basis of the results, the authors measured the growth and development, various kinds of physiques, nutritional index of the 6 to 20s age group. Second, the authors presented the standard body weight of males and females by their body height, who were in the end of their growth (20-29 age group). Third, the authors calculated and presented the normal adapted body weight of the age group who were over 30 age after the growth had been completed. Forth, the author presented the obesity rate of the adults over 20 years old by body mass index. Finally, the authors compared chronological change of the Koreans' body heights and body weights with the results of other researchers. 1. Body Measurement Rapid growth, in terms of body height, which is described by a straight line on a growth curve has been observed among males in the ages 6-13 and among females 6-14. That growth curve turned out to be slower among the people of higher ages by both sexes. The cross-over occurred in both sexes at 11-14. The highest growth rate for a year is at 13-16 for males and 11-13 for females. This indicates that females enter a rapidly growing stage 2 years earlier than males. 2. Various Physiques and Nutritional Index Rapid growth, in terms of Relative Body Weight Index, which is described by a straight line, has been observed among males in the ages 6-16 and females in the ages 6-14. The cross-over occurred in both sexes 12.5-14.5 age in the adolescencent period. Whereupon females outgrow males. The Roher Index displayed more good value in case of females than male and in the adolescent period, the level of fullness is lower than after the completion of development. The Kaup Indices of both sexes increase with age. The index is less than 2.0 for males in 6-14 age group and for females in 6-13 age group and with this, it appeared that development of horizontal axis to long axis is poor. The index is more than 2.0 after 15 age group in males and 14 age group in females and developmental state4 age group and for females in 6-13 age group and with this, it appeared that development of horizontal axis to long axis is poor. The index is more than 2.0 after 15 age group in males and 14 age group in females and developmental state Body Mass Index is less than 20 for males 6-14 age group and for females in 6-13 age group. In the case of the higher age group, that index maintains a normal state.

  • PDF

The Development of Men's Dress Form for Pattern Making (패턴메이킹을 위한 남성(男性) 인대개발(開發)에 관(關)한 연구(硏究))

  • Yoo, Hyun;Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.10 no.5
    • /
    • pp.159-179
    • /
    • 2006
  • This research checked about the necessity for the development of men's dress forms in the first investigation for the educational circle and the men's wear industry. Somatotype characteristics were analyzed in the second investigation of body measurement with the subjects of 200 male adults in their twenties residing in Busan. The following are the results of the present research to develop male dress forms for patternmaking: 1. In the group analysis for the characterization of front body types, three somatotypes were found and named H, Semi X, and Y. In the cluster analysis of side body types, four types were identified: D, I, d, and q. In the combination of front and lateral body types, four kinds were chosen: semi X-I, semi X-q, semi Y-I, and Y-q. 2. Through the comparison of plane figures by the plaster method as well as horizontal and vertical cross sections by the sliding gauge method, semi X-I was finally chosen as the standard somatotype for male dress form development. 3. Compared with the sliding gauge method of the present dress forms, the research dress form reflected better the shapes of the parts of the back and hips and the position of the waist, especially for males in their 20's. In addition, the dress form in the current research had superior points in all the items of clothing evaluation. Based on the above results, the sizes and models of the men's dress forms for patternmaking were developed.

A Study on the Basic Bodice Pattern for the Fatty Body -The subject of middle-aged women- (비만체형을 위한 기본 Bodice 원형연구 -중년기 부인을 중심으로-)

  • 한애미
    • Journal of the Korean Home Economics Association
    • /
    • v.25 no.3
    • /
    • pp.15-26
    • /
    • 1987
  • The purpose of this study was to develop the pattern drafting method which would be suitable to their physical characteristics for the fatty body of 40∼55 aged Korean women who are more than 1.5 Rohrer's Index and 90㎝ bust girth. The study was composed as follows; 1. Body measurement and statistical analysis: One hundred and thirty women were measured on 29 items. Thirty-four items including 29 measured items and 5 calcutated items were analyzed statistically. 1) Mean, standard deviation, variance, maximum, minimum, range were computed. 2) Correlation coefficients between each items were computed. 2. Development of new bodice pattern drafting method: Measurement items necessary to draft new bodice pattern were bust girth, center back waist length, shoulder width, back width, chest and neck base girth. The new pattern was examined through three wearing tests for completion. 3. Evaluation of the new pattern drafting method: The new pattern was objectively evaluated by the sensory test. The sensory evaluation was applied to evaluate the new pattern for the fatty body women by comparint it with the conventional patterns. The results of sensory tests of the new pattern are as follows: 1) The composite reliability coefficient is 0.7698, and the reliability of sensory test shows high. 2) According to a statistical analysis of the result of the 23 items on the questionaire, all the items showed significant differences(α 0.01) between the two, with the new pattern having higher scores. The new pattern is better conventional pattern as the average mark of the former is 3.901 but that of latter is 2.926. The new pattern drafting method proved to be superior to the conventional one especially in the fitness at the center front neck point, shoulder point, side line, armscye depth, position of bust point, chest width line, under arm dart and the shoulder line.

  • PDF

Development and validation of prediction equations for the assessment of muscle or fat mass using anthropometric measurements, serum creatinine level, and lifestyle factors among Korean adults

  • Lee, Gyeongsil;Chang, Jooyoung;Hwang, Seung-sik;Son, Joung Sik;Park, Sang Min
    • Nutrition Research and Practice
    • /
    • v.15 no.1
    • /
    • pp.95-105
    • /
    • 2021
  • BACKGROUND/OBJECTIVES: The measurement of body composition, including muscle and fat mass, remains challenging in large epidemiological studies due to time constraint and cost when using accurate modalities. Therefore, this study aimed to develop and validate prediction equations according to sex to measure lean body mass (LBM), appendicular skeletal muscle mass (ASM), and body fat mass (BFM) using anthropometric measurement, serum creatinine level, and lifestyle factors as independent variables and dual-energy X-ray absorptiometry as the reference method. SUBJECTS/METHODS: A sample of the Korean general adult population (men: 7,599; women: 10,009) from the Korean National Health and Nutrition Examination Survey 2008-2011 was included in this study. The participants were divided into the derivation and validation groups via a random number generator (with a ratio of 70:30). The prediction equations were developed using a series of multivariable linear regressions and validated using the Bland-Altman plot and intraclass correlation coefficient (ICC). RESULTS: The initial and practical equations that included age, height, weight, and waist circumference had a different predictive ability for LBM (men: R2 = 0.85, standard error of estimate [SEE] = 2.7 kg; women: R2 = 0.78, SEE = 2.2 kg), ASM (men: R2 = 0.81, SEE = 1.6 kg; women: R2 = 0.71, SEE = 1.2 kg), and BFM (men: R2 = 0.74, SEE = 2.7 kg; women: R2 = 0.83, SEE = 2.2 kg) according to sex. Compared with the first prediction equation, the addition of other factors, including serum creatinine level, physical activity, smoking status, and alcohol use, resulted in an R2 that is higher by 0.01 and SEE that is lower by 0.1. CONCLUSIONS: All equations had low bias, moderate agreement based on the Bland-Altman plot, and high ICC, and this result showed that these equations can be further applied to other epidemiologic studies.

Comparison of Avatar Posture Formation According to 3D Virtual Garment Modeling Programs -Focusing on Cycling Movements of High-School Male Cyclist-

  • Park, Hyunjeong;Do, Wolhee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.6
    • /
    • pp.965-977
    • /
    • 2021
  • The study aimed to analyze the functional differences in 3D virtual garment programs and compare body scan data with the corresponding 3D virtual models. We selected 3D virtual garment programs, formed virtual models in a representative size for high-school male cyclists, and analyzed them using the Design-X program. The results were as follows. In the 3D virtual garment programs, the anthropometric items for virtual model forming differed significantly from the standard anthropometric items suggested by Size Korea. Comparing the lower body scan data and virtual models formed by the 3D virtual garment programs, the biggest difference was in the shapes of the waist and hips, i.e., the flatness values of the waist and hips were different for each program in the cross-section view. In the lower body, a data-input-based program was needed for changing the exact measurement position of the waist circumference and hips' shape in detail. If a 3D virtual garment program provides functions for the virtual model's joint angle input and free motion transformation, it is expected to be widely used in the sportswear industry.

A Study on The Sizes of Ready-made Clothes to Export to China - Corresponding Sizes of China Women's and Men's Ready-made Clothes Sizes Based on KS size specification- (중국수출(中國輸出) 기성복(旣成服)의 치수에 관한 연구(硏究)-KS규격(規格)을 중심(中心)으로 한 중국((中國) 여성복 (女性服)및 남성복(男性服)의 대응(對應)치수-)

  • Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.11 no.4
    • /
    • pp.152-172
    • /
    • 2007
  • This research suggest the correspondent sizes of women's and men's ready-made clothes to export to China on the basis of KS size specification. The results of this study, with the cooperation of Sejung and Searte Companies exporting clothes to Ningbo City, Zhejiang Province in China, are as follows: 1. Corresponding Dimensions of China Women's Clothes According to Morrison's relative deviation method, the body measurement characteristics of Chines and Korean women in their 30s and 40s were compared. As a result, Chinese women were bigger in height, arm length, abdomen girth, and upper arm girth but smaller in shoulder length and shoulder width. The cluster analysis for body type classification was as follows: Type 1, tall and well-developed, was 34.8%. Type 2 with weaker upper body, medium height, narrow shoulders and a slim waist was 45%. Type 3 with stronger upper body, shortest height and wide shoulders was 20.2%. 2. Corresponding Dimensions of China Men's Clothes Based on the drop standard of KS K 0050, the body types of Chinese men in their 20s were classified. A body types were 55.77%, Y body types were 32.16%, B body types were 11.55% and BB body types were 1.51%. According to the criteria of ready-made dimensions of normal body type suggested in Korea Standards, and in consideration of the basic distribution reality of body dimensions, representative 5 sizes were selected. 3. The corresponding size specification of China women's and men's clothes based on those of KS size specification were presented here, showing product sizes and physical items in detail.

Method of Saliva Collection for Salivary Cortisol Measurement (타액 코티졸 측정을 위한 타액 수집 방법 조사)

  • Choi, Sanho;Lee, Ilsuk;Song, Inja;Kwon, O Jong;Park, Keeeon;Hong, Haejin;Sung, Kang-Keyng;Lee, Sangkwan
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.2
    • /
    • pp.223-232
    • /
    • 2014
  • Most of salivary cortisol are an unbound free form reflecting physiological function later. Thus, it is used frequently to evaluate the HPA-Axis and physiological function. Although the needs of salivary cortisol measurement in Korean Medicine is higher and higher, there are not many studies, because the reliability of salivary cortisol measurement is not high. To make the reliability high and encourage to use it in Korean Medicine, the goal of this study is to suggest the standard method of saliva collecting for cortisol measurement through the review of previous studies using salivary cortisol and to encourage to use it in clinical fields in Korean Medicine. The results are as followed; First, salivary cortisol has many benefits, i. e. easy collecting, non-invasive collecting, and reflecting the physiological function. Second, the collecting time and method are kept sternly, because the methods of saliva collecting vary depending on the goal of study. Third, the specific tools for saliva collecting are recommended to prevent contamination. In conclusion, if the standard methods of saliva collecting is kept to measure salivary cortisol, it would be very useful in many fields of Korean Medicine.

Comparison on Nano-particle Number Measurement Characteristics for Different Particle Generators between Spray type and Soot Type (Spray type과 Soot type 입자발생기별 나노입자 개수농도분포 측정특성 비교)

  • Kim, M.S.;Kwon, J.W.;Chung, M.C.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.17 no.4
    • /
    • pp.185-191
    • /
    • 2012
  • Particulate matters (PM) that is generated by most diesel engine is regulated by the mass concentration measured by the conventional method it had been. Recently, Europe PMP (Particle Measurement Program) decided to start the regulation of vehicle's nano-sized particle number (PN) from the year of 2011 because of nano-particle's higher degree of harm to the human body. So firstly, the standard level of PN emission is introduced in the Euro 5/6 emissions regulation with a limit of $6{\times}10^{11}$ per km for light duty vehicle. Also KPMP(Korea Particle Measurement Program) was organized to copy quickly international technical trend. In this paper, it was investigated the nano-sized PN measurement characteristics for different particle generators between spray type and soot type. And the difference ratio between particle generators, the characteristic of PN concentration, counting efficiency and linearity was analyzed. Then, we make conclusions as followed. When particle diameter is increased, counting efficiency of two generators is decreased. Also Secondary calibration method is more higher 3% than Primary calibration method. Finally, SOF which is included in soot particles is not totally removed so it have great influence on test result of counting efficiency and linearity.

Reliability of Scapular Winging Measurement Using a Scapulometer (익상견갑의 평가를 위한 "Scapulometer"의 신뢰도 연구)

  • Weon, Jong-Hyuek;Choi, Houng-Sik;Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.17 no.2
    • /
    • pp.10-16
    • /
    • 2010
  • This study was undertaken to develop the scapulometer, a measuring tool for scapular winging, and to determine the reliability of scapulometer. Thirty subjects with scapular winging greater than 2 cm participated in this study. Two examiners measured scapular winging using the scapulometer. Standardized measurement position of each subject was as follows: neutral position of shoulder and wrist, $90^{\circ}$ flexion of elbow, and cuff weight of 5% and 10% of body weight (BW) to neutral wrist. The interrater and intrarater reliability were calculated with an intraclass correlation coefficient (ICC) with 95% confidence interval (CI) and standard error of measurement (SEM) at 5% BW and 10% BW. The level of scapular winging was tested between 5% BW and 10% BW with a paired t-test. The interrater reliability was shown to be high at 5% BW (ICC(2,k)=.955, 95% CI=.900~.979, SEM=.07) and at 10% BW (ICC(2,k)=.968, 95% CI=.930~.985, SEM=.06). The intrarater reliability was shown to be high at 5% BW (ICC(2,k)=.921, 95% CI=.842~.961, SEM=.09) and at 10% BW (ICC(2,k)=.906, 95% CI=.813~.954, SEM=.10). The level of scapular winging was significantly different between 5% BW and 10% BW. Conclusively, it is demonstrated that the scapulometer is an objective and qualitative measurement tool for scapular winging.