• Title/Summary/Keyword: Standard School Building

Search Result 287, Processing Time 0.022 seconds

Development of Standard Agreement for a School Complex Project (학교시설 복합화를 위한 표준협약서 개발)

  • Park, Sung-Chul;Park, Hee-Won;Jung, Tae-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.13 no.2
    • /
    • pp.1-12
    • /
    • 2014
  • A school building complex means building both the learning spaces of students and convenience space of community within school lands. The projects have has a positive effect on saving the national budget as well as expanding the learning spaces. The absence of standard agreement contracted through discussion of participants, however, has made many problems in the operated projects. Through analysis on the previous researches and conference, the paper finds main problems discussed in the operating step. And, the feasibility study is carried out in order to analyze the appropriateness of on the existing agreements on the problems. Finally, the paper presents the standard agreement for the school building complex projects. The practitioners can prevent the existing problems from new projects through using the proposed agreement. Furthermore, it is expected that the school building complex projects will be activated.

Seismic Retrofit of an Existing School Building using CIP-Infilled Shear Walls and Steel Braces (현장타설 끼움 전단벽 및 철골가새를 활용한 기존 학교 건물의 내진보강)

  • Youn, Gil-Ho;Kim, Sung-Ho;Kim, Yong-Cheol;Yun, Hyun-Do
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.4
    • /
    • pp.21-28
    • /
    • 2012
  • This study proposes a procedure for evaluating the seismic performance and retrofit of a typical reinforced building (R/C) school buildings contructed in the 1980s. The procedure is derived from the Japanese Standard for Evaluation of Seismic Capacity of Existing Reinforced Concrete Buildings and Nonlinear Static Procedure (NSP) specified in Federal Emergency Management Agency (FEMA 356). In this study, the Japanese Standard was applied for evaluating the additionally required seismic performance in the existing school building. Cast-in-place (CIP) reinforced concrete infill walls and steel braces were used to seismically retrofit the existing school building located in the region of Hongsung in Chungnam. In the pushover analysis, i.e NSP, the hinge properties of columns, beams, infill walls and steel braces were carefully calibrated based on the existing experiment results in the available literatures. The predicted seismic performance for the retrofitted building was compared to that for the virgin building. Based on the seismic evaluation with the Japanese Standard and the FEMA 356 criteria, the addition of CIP reinforced concrete infill walls and steel braces have superior constructablility and can improve effectively the seismic performance of the existing school buildings constructed in 1980s.

A Study on Comparing and Analyzing Domestic and Foreign Green Building Certification Criteria for School Facility -Focused on the G-SEED and LEED, BREEAM- (국내외 학교시설 녹색 건축 인증제도의 비교분석에 관한 기초연구 -G-SEED와 LEED, BREEAM을 중심으로-)

  • Lee, Jong-Kuk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.13 no.3
    • /
    • pp.15-22
    • /
    • 2014
  • Proceeded with a research with basic data about the qualification standard improvement scheme about the environment school architecture in which a comparison analyze the specialized field of BREEAM system of LEED of the hit environment building qualification standard G-SEED of the domestic and U.S Green Building Counci evaluated with the certification system of the world top class and Building Research Establish, essential item, and mark distribution and weight in this study at this and which I hit with a domestic afterward. The school facility with a hub among the equipment receiving the hit environmental qualification standard, and the range of this research does LEED of the domestic green building certification system February is revised in 2013 G-SEED and which US and BREEAM in UK with a range. The way of the research checked the environment school building certification system and situation hit home and abroad, and a comparison analyze the division of the specialized field of each country qualification standard, essential item, and mark distribution and weight.

Energy Performance Evaluation of A Primary School Building for Zero Energy School (제로에너지 스쿨을 위한 초등 교육시설의 에너지 성능평가)

  • Yoon, Jong-Ho;Shin, U-Cheul;Cho, Jin-Il;Park, Jae-Wan;Kim, Hyo-Jung;Lee, Chul-Sung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.121-126
    • /
    • 2009
  • This study analyzed the standard school's energy usage and patterns as the zero-energy goal of primary school building, and proposed the energy reduction process of school building using energy analysis computing simulation tool. As a analysis simulation tool, Visual DOE 4.0 is used. For analysis of actual energy usage, selected primary school that is standard in the nation's energy consumption. Standard of the school's energy consumption analysis were devided into electric and gas energy. Input parameters of the simulation program based on the literature material and field survey material. after, but it was calibrated to comparison with the standard school's energy consumption. Finally, its energy usage analyzed by component and made the priority order of energy saving. Applied energy saving technologies are envelopment insulation, high efficiency lighting, high performance HAVC system and used active equipment system of solar collector and photovoltaic generation for additional savings.

  • PDF

A Study on Realization Method of Low Carbon School Building (저 탄소 학교건축물 구현 방안에 관한 연구)

  • Tae, Sung-Ho;Cho, Young-Sang;Shin, Sung-Woo;Lee, Seung-Min;Meang, Joon-Ho
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.9 no.2
    • /
    • pp.30-37
    • /
    • 2010
  • This study purposed realization and a phase reduction of school building $CO_2$ emissions. Accordingly selected standard school buildings and evaluated life cycle environmental load($CO_2$). This study proposed Green building technology which separated design sector, energy sector, afforestation sector for carbon-neutral city school buildings realization of M-city. As a result, elementary, middle and high schools of M-city built in the year 2013 were required that design sector was Energy Performance Index(EPI) 75 point and energy sector was solar installations more than 25% of the power usage, Solar systems installed more than 10% of total gas consumption and the area of afforesting more than 35% of the ecological area to achieve 30% $CO_2$ reduction compared to the Respectively standard school buildings.

Wind Effects on Tall Buildings with a Porous Double-Skin Façade

  • Shengyu Tian;Cassandra Brigden;Caroline Kingsford;Gang Hu;Robert Ong;K.C.S. Kwok
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.265-276
    • /
    • 2022
  • Double-Skin Facades (DSF) on tall buildings are becoming increasingly common in urban environments due to their ability to provide architectural merit, passive design, acoustic control and even improved structural efficiency. This study aims to understand the effects of porous DSF on the aerodynamic characteristics of tall buildings using wind tunnel tests. High Frequency Force Balance and pressure tests were performed on the CAARC standard tall building model with a variable porous DSF on the windward face. The introduction of a porous DSF did not adversely affect the overall mean forces and moments experienced by the building, with few differences compared to the standard tall building model. There was also minimal variation between the results for the three porosities tested: 50%, 65% and 80%. The presence of a full-height porous DSF was shown to effectively reduce the mean and fluctuating wind pressure on the side face of the building by about 10%, and a porous DSF over the lower half height of the building was almost as effective. This indicates that the porous DSF could be used to reduce the design load on cladding and fixtures on the side faces of tall buildings, where most damage to facades typically occurs.

Forecasted Weather based Weather Data File Generation Techniques for Real-time Building Simulation (실시간 빌딩 시뮬레이션을 위한 예측 기상 기반의 기상 데이터 파일 작성 기법)

  • Kwak, Young-Hoon;Jeong, Yong-Woo;Han, Hey-Sim;Jang, Cheol-Yong;Huh, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.8-18
    • /
    • 2014
  • Building simulation is used in a variety of sectors. In its early years, building simulation was mainly used in the design phase of a building for basic functions. Recently, however, it has become increasingly important during the operating phase, for commissioning and facility management. Most building simulation tools are used to estimate the thermal environment and energy consumption performance, and hence, they require the inputting of hourly weather data. A building simulation used for prediction should take into account the use of standard weather data. Weather data, which is used as input for a building simulation, plays a crucial role in the prediction performance, and hence, the selection of appropriate weather data is considered highly important. The present study proposed a technique for generating real-time weather data files, as opposed to the standard weather data files, which are required for running the building simulation. The forecasted weather elements provided by the Korea Meteorological Administration (KMA), the elements produced by the calculations, those utilizing the built-in functions of Energy Plus, and those that use standard values are combined for hourly input. The real-time weather data files generated using the technique proposed in the present study have been validated to compare with measured data and simulated data via EnergyPlus. The results of the present study are expected to increase the prediction accuracy of building control simulation results in the future.

An Analysis of Thermal Loads Depending on Korea Building Insulation Standard and the Optimum Insulation Standard (국내 건물 단열기준에 따른 냉.난방 부하 분석 및 최적 단열기준에 관한 고찰)

  • Seo, Sung-Mo;Park, Jin-Chul;Rhee, Eun-Ku
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.146-155
    • /
    • 2011
  • Sustainable building is getting more and more important topic in 21C. Following this trend, building energy saving standard has been reinforced in Korea. Especially, insulation standards are revised continuously after1979. This study aims to evaluate the correlation between the revised insulation standards and heating and cooling loads of a residential building. This study shows that the standard of insulation is more related with heating load than cooling load, and cooling load is more related with other sources such as glass types and solar incidence through windows. In case of highly-insulated building such Passive Houses or Zero Energy Houses, the cooling load should also be considered as important as heating load when revising the building energy saving regulations in the future.

A Comparative Study on the Assessment Items of Korea's Apartment Building Certification Systems (국내 공동주택 관련 인증제도의 세부 항목에 대한 비교 분석에 관한 연구)

  • Jung, Ji-Na;Tae, Choon-Seob;Yang, Jeong-Hoon;Park, Sang-Dong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.116-123
    • /
    • 2010
  • A various building certification systems are being enforced in Korea. However, the enforcement of many building certification systems has brought on the concerned people's confusion and the operation of various building certification systems which have similar assesment items causes much time and economical losses. Therefore, in this paper, the features of the GBCS(Green Building Certification System), Housing Performance Indication System, Building Energy Rating System, and Green Home Standard and Performance Evaluation System are compared and the correlations among each building certification system are analysed. As a result, it is presented that a considerable number of assessment items were so similar and identical that integration of building certification systems is needed for effective operation of these systems.

Basic research on the Building Energy Load Depending on The Climate Change in Korea (대한민국 표준기상데이터의 변화추이와 건물부하량에 관한 기초연구)

  • Yoo, Ho-Chun;Lee, Kwan-Ho;Kang, Hyun-Gu
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.66-72
    • /
    • 2009
  • As 'Low Carbon Green Building' is highly required, programs to evaluate building performance are actively and commonly used. For most of these programs, dynamic responses of buildings against external weather changes are very important. In order to simulate the programs, weather data of each region must be properly entered to estimate accurate amount of building energy consumption. To this end, the existing weather data and weather data of KSES were compared and analyzed to find out how weather changes. Energy load of Korea's standard houses was also analyzed based on this data. As a result, data corresponding to June ${\sim}$ September when cooling is supplied shows 23% of average increase with 30% of peak increase(June). On the other hand, data corresponding to November ${\sim}$ February when heating is supplied shows 29% of average decrease with 34% of peak decrease(November). Increase in cooling load and decrease in heating load in the above data comparison/analysis show that KSES 2009 data reflects increase in average temperature caused by global warming unlike the existing data. Increase in dry-bulb temperature depending on weather change of standard houses increases cooling load by 17% and decreases heating load by 36%